Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

The development and use of metal-based probes for X-ray fluorescence microscopy

Abstract X-ray fluorescence microscopy (XFM) has become a widely used technique for imaging the concentration and distribution of metal ions in cells and tissues. Recent advances in synchrotron sources, optics, and detectors have improved the spatial resolution of the technique to <10 nm with attogram detection sensitivity. However, to make XFM most beneficial for bioimaging—especially at the nanoscale—the metal ion distribution must be visualized within the subcellular context of the cell. Over the years, a number of approaches have been taken to develop X-ray-sensitive tags that permit the visualization of specific organelles or proteins using XFM. In this review, we examine the types of X-ray fluorophore used, including nanomaterials and metal ions, and the approaches used to incorporate the metal into their target binding site via antibodies, genetically encoded metal-binding peptides, affinity labeling, or cell-specific peptides. We evaluate their advantages and disadvantages, review the scientific findings, and discuss the needs for future development.

36 MATERIALS SCIENCE↗

Toward ultrafast, ultra-stable imaging arrays: Superlattice doping to enhance the performance of backside-illuminated 3D-hybridized silicon photodetectors

In this paper, the authors report the latest results on their development of superlattice-doped, thinned, backside-illuminated (BSI), 3D-integrated photodiode detectors—a step toward their ultimate goal of demonstrating ultrafast, ultrastable CMOS imaging arrays. As with most silicon-based photodetectors, backside-illumination and backside surface passivation are keys to achieve the highest performance capability. The two-dimensional (2D) doping technique developed at the Jet Propulsion Laboratory (JPL) has proved to result in a highly efficient, highly stable detector response when combined with a variety of detectors. Here, JPL's 2D-doping has been combined with Sandia's BSI photodetectors hybridized with custom fanout wafer via copper Direct Bond Interconnect (DBI®), a technology that is rapidly becoming industry standard for BSI CMOS imaging arrays. The prototype detectors were packaged and evaluated with respect to their response to low energy electrons. The authors find that the responsivity of 2D-doped BSI detectors is higher than devices prepared using other surface passivation techniques (i.e., ion implantation). The success of the work described herein verifies that the 2D-doping processes previously developed for Sandia's frontside-illuminated photodetectors are generally applicable to BSI detectors and demonstrates for the first time that JPL's 2D-doping process is compatible with the Cu-DBI® technology.

Jewell, April D.↗

Physics-based stabilized finite element approximations of the Poisson–Nernst–Planck equations

We present and analyze two stabilized finite element methods for solving numerically the Poisson–Nernst–Planck equations. The stabilization we consider is carried out by using a shock detector and a discrete graph Laplacian operator for the ion equations, whereas the discrete equation for the electric potential need not be stabilized. Discrete solutions stemmed from the first algorithm preserve both maximum and minimum discrete principles. For the second algorithm, its discrete solutions are conceived so that they hold discrete principles and obey an entropy law provided that an acuteness condition is imposed for meshes. Remarkably the latter is found to be unconditionally stable. We validate our methodology through transient numerical experiments that show convergence toward steady-state solutions.

97 MATHEMATICS AND COMPUTING↗

Exclusive J/$\psi$ detection and physics with ECCE

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been recommended as a reference design for the proposed Electron-Ion Collider (EIC) program. Here, this paper presents simulation studies of exclusive J/$\psi$ detection and selected physics impact results in EIC using the projected ECCE detector concept. Exclusive quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. Preliminary results estimate the excellent statistics benefited from the large cross section of J/$\psi$ photoproduction and superior performance of ECCE detector concept. The precise measurement of exclusive J/$\psi$ photoproduction at EIC will help us to more deeply understand nuclear gluon distributions, near threshold production mechanism and nucleon mass structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hadron blind Cherenkov counters

A Hadron Blind Detector, or HBD, is a novel form of Cherenkov counter that is designed to provide high efficiency for detecting highly relativistic electrons while being essentially blind to most hadrons. Herein, we present some of the most prominent realizations of the HBD concept in real experiments. We describe the first implementation of an HBD that was made in the CERES experiment at CERN using a spectrometer based on a doublet of hadron blind RICH detectors for the measurement of low-mass electron pairs in pA and AA collisions at the SPS. We next present a detailed account of a more extensive realization of the HBD that was made in the PHENIX experiment for the measurement of low-mass electron pairs in central heavy-ion collisions at RHIC, followed by a description of a very similar detector that is currently under construction at J-PARC for the measurement of vector mesons through their e + e – decay in pA collisions. We conclude with a brief discussion of possible evolutions of the HBD concept as well as possible developments and uses of HBDs in experiments at the future Electron Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of dynamics and decay in the St. Benedict Paul trap

The St. Benedict experiment includes a linear Paul trap designed to measure the beta-neutrino angular correlation coefficient 𝑎 𝛽ν of mixed superallowed 𝛽-decay transitions between mirror nuclei via coincidence detection of 𝛽-particles and recoiling ions. The emitted 𝛽 particle and daughter ion are detected with plastic scintillators and micro-channel plate detectors, respectively, allowing for accurate measurements of their time-of-flights. From the shape of the coincidence time-of-flight distribution, a value of 𝑎 𝛽ν can be determined. This manuscript presents detailed simulations of the St. Benedict Paul trap, with a focus on ion cloud dynamics and recoiling daughter trajectories.

Linear Paul trap↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗

Electric accumulation of millicharged particles

A terrestrial population of millicharged particles that interact significantly with normal matter can arise if they make up a dark matter subcomponent or if they are light enough to be produced in cosmic-ray air showers. Such particles thermalize to terrestrial temperatures through repeated scatters with normal matter in Earth’s environment. We show that a simple electrified shell (for example, a Van de Graaff generator) functions as an efficient accumulator of such room-temperature millicharged particles, parametrically enhancing their local density by as much as 12 orders of magnitude. This can be used to boost the sensitivity of any detector housed in the shell’s interior, such as ion traps and tests of Coulomb’s law. In a companion paper, we apply this specifically to Cavendish tests of Coulomb’s law, and we show that a well-established setup can probe a large region of unexplored parameter space, with sensitivity to the irreducible density of millicharged particles generated from cosmic rays that outperforms future accelerator searches for sub-GeV masses.

Berlin, Asher [Fermilab] (ORCID:0000000211561482)↗

Tagging efficiency study of incoherent diffractive vector meson production at the second interaction region at the Electron-Ion Collider

The Electron-Ion Collider (EIC) is an upcoming accelerator facility aimed at exploring the properties of quarks and gluons in nucleons and nuclei, shedding light on their structure and dynamics. The inaugural experimental apparatus, ePIC (electron-Proton and Ion Collider), is designed as a general-purpose detector to address the National Academy of Sciences and the Nuclear Science Advisory Committee physics program at the EIC. The wider EIC community is strongly supporting a second interaction region and an associated second detector to enhance the full science program. In this study, we evaluate how this second interaction region and detector can be complementary to ePIC. The layout of an interaction region for the second detector offers a secondary focus that provides better forward detector acceptance at scattering angles near θ ~ 0 mrad, which can specifically enhance the exclusive, tagging, and diffractive physics program. Here, this article presents an analysis of a tagging program using the second interaction region layout with incoherent diffractive vector meson production. The current design of the second EIC interaction region is evaluated for its vetoing capabilities of incoherent events required for the study of coherent diffractive measurements. We find an increased vetoing performance compared to the ePIC interaction region, thus improving measurements which are important for the spatial imaging of nucleons and nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anisotropic Flow in Fixed-Target 208 Pb + 20 Ne Collisions as a Probe of Quark-Gluon Plasma

The System for Measuring Overlap with Gas (SMOG2) at the LHCb detector enables the study of fixed-target ion-ion collisions at relativistic energies ($\sqrt{𝑠_{NN}}$ ∼ 100 GeV in the center of mass). Here, with input from ab initio calculations of the structure of 16 O and 20 Ne , we compute 3+1⁢D hydrodynamic predictions for the anisotropic flow of Pb+Ne and Pb+O collisions to be tested with upcoming LHCb data. This will allow the detailed study of quark-gluon plasma formation as well as experimental tests of the predicted nuclear shapes. Elliptic flow (𝑣 2 ) in Pb + Ne collisions is greatly enhanced compared to the Pb + O baseline due to the shape of 20 Ne , which is deformed in a bowling-pin geometry. Owing to the large 208 Pb radius, this effect is seen in a broad centrality range, a unique feature of this collision configuration. Larger elliptic flow further enhances the quadrangular flow (𝑣 4 ) of Pb + Ne collisions via nonlinear coupling, and impacts the sign of the kurtosis of the elliptic flow vector distribution (𝑐 2 ⁡{4}). Exploiting the shape of 20 Ne proves thus an ideal method to investigate the formation of quark-gluon plasma in fixed-target experiments at LHCb, and demonstrates the power of System for Measuring Overlap with Gas as a tool to image nuclear ground states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Thin Gap GEM-µRWELL Hybrid Detectors at Jefferson Lab

Over the past few decades, Micro Pattern Gaseous Detector (MPGD) technologies have been increasingly adopted as tracking detector options in High Energy and Nuclear Physics experiments thanks to their good spatial resolution, high-rate capability, stability and more importantly their ability for large area coverage at a relatively low cost compared to the alternative. The thin gap GEM-µRWELL hybrid detector is the latest addition to the MPGD family, that was introduced to vastly improve the spatial resolution capability of gaseous trackers when deployed in the barrel region to cover large angular acceptance of the central tracker in a collider experiment. In this talk, I will re-introduce the concept and motivation for the development of thin gap GEM-µRWELL hybrid technology with an emphasis on the initial studies that establish the proof-of-concept of the technology. I will then discuss the more recent results from latest beam test campaign at Jefferson Lab in May 2025 to study detector efficiency performance with various gas mixtures. I will also briefly present the ongoing activities to develop large area thin gap GEM-µRWELL tracking detectors for the ePIC experiment of the future Electron Ion Collider as well as the exploration of the technology to provide large area tracking options to the muon system of experiments at a future Higgs Factory Collider such as the FCC-ee for example. Finally, I will conclude with some perspectives on new ideas under exploration to develop the next generation of thin gap MPGD technologies with enhanced timing and spatial resolution capabilities

Gnanvo, Kondo [Thomas Jefferson National Accelerat↗

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel Jana Howard1,3, Guang Yang3, Haiyan Zhao1*, Patrick Warren4, Tiankai Yao3, Steven Cavazos4 Elizabeth Sooby Wood4*, Ching-heng Shiau2 1 University of Idaho, Environmental Science, Idaho Falls, Idaho, USA 2 Boise State University, Microscopy and Characterization Suite, Idaho Falls, Idaho, USA 3 Idaho National Laboratory, Idaho Falls, Idaho, USA 4 University of Texas San Antonio, Department of Physics and Astronomy, San Antonio, Texas, USA *Corresponding author: haiyanz@uidaho.edu; elizabeth.soobywood@utsa.edu Tri-structural Isotropic (TRISO) particle fuel is the preferred choice for the newest and next-generation high-temperature nuclear reactors due to its robust construction [1]. The fuel design effectively contains fission products inside the particle at extremely high temperatures [2]. However, the effect of transition metal fission products on fuel performance and structural integrity remains largely unknown, creating uncertainties in predicting fuel performance and potential failure mechanisms [2]. For example, palladium (Pd) has a strong tendency to form intermetallic phases with uranium (U). These new phases tend to be hard and brittle which could lead to fracture of fuel kernel during irradiation [3,4]. Pd is not normally produced in high concentrations in normal fission reactions however, driving the production of Pd into the locality of a Uranium Oxycarbide (UCO) nuclear fuel provides an opportunity to closely observe the diffusion and chemical interactions. This study focuses on detailed transmission electron microscopy characterization of the intermetallic phases formed by the interaction between a UCO kernel and a Pd bar after annealing at 1100 °C for 100 hours. Figure 1 provides an overview of the UCO kernel in contact with the Pd bar. The UCO-Pd sample surface was examined using a Focused Ion Beam (FIB) Quanta 3D FEG FEI in VCD detector mode at 10kV, 83pA to reveal surface features. Several key surface features in the interaction region were observed including: (1) a small area with dendritic microstructure, (2) color contrast near the UCO kernel and Pd boundary, and (3) darker and lighter regions throughout the sample surface. To analyze diffusion behavior, FIB was used to prepare lamellae from five different areas of the UCO-Pd sample, as well as one for the as-received sample. These lamellae were examined using a Scanning Transmission Electron Microscope ThermoFisher Spectra 300 (STEM-Spectra). Energy Dispersive Spectroscopy results confirmed the diffusion between the UCO fuel and Pd bar. Figure 2 shows the identified phases of UC, UO2, and Pd dispersed throughout the interaction region. It was also found that the Pd concentration decreases as the radial distance from the UCO-Pd interface increases. The Pd concentration was 36.93% atomic fraction 11µm from the interaction region then decreased to 7.51% atomic fraction at 257 µm away from the interaction region. Figure 3 shows how concentrations of U and Pd vary across the interaction zone, highlighting the extent of diffusion. This study confirms that Pd interacts with surrounding material to form U-Pd phase and diffusion zones. These diffusion zones vary in composition depending on its radial distance from the point of contact with the Pd bar. These findings contribute to a deeper understanding of the fission product behavior in high temperature nuclear fuels, aiding in the prediction and mitigation of potential fuel degradation mechanisms. A B C Fig. 1. SEM micrographs of UCO fuel kernel in contact with solid Pd bar and the lift out locations. Figure 1A shows UCO fuel kernel in contact with solid Pd bar. Figure 1B shows a higher magnification image of the UCO fuel-Pd interaction zone. Figure 1C shows lift out sites for the lamellae. A B C Fig 2. EDS maps reveal the distribution of U, O, and Pd in location 3. Figure 2A shows the distribution of uranium. Figure 2B shows the distribution of oxygen. Figure 2C shows the distribution of palladium. A B C Fig 3. Palladium and uranium concentration across interaction zone in location 2. Figure 3A shows EDS map of lift out number 2. Figure 3B shows a zoomed in EDS map taken from the interaction zone. Figure 3C shows a line graph of uranium and palladium concentrations across the interaction zone. References: 1. B.E. Wells, N.R. Phillips, K.J. Geelhood. Pacific West Laboratory. (2021). TRISO Fuel: Properties and Failure Modes. https://www.nrc.gov/docs/ML2117/ML21175A152.pdf (Accessed January 16, 2025). 2. American Nuclear Society. TRISO Fuel Development Progresses in INL, ORNL. https://www.gen-4.org/gif/upload/docs/application/pdf/2014-03/nov13nn_fuel_reprint.pdf (Accessed January 16, 2025) 3. Clark R.A., M.A. Con

36 - MATERIALS SCIENCE↗

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel Jana Howard1,3, Guang Yang3, Haiyan Zhao1*, Patrick Warren4, Tiankai Yao3, Steven Cavazos4 Elizabeth Sooby Wood4*, Ching-heng Shiau2 1 University of Idaho, Environmental Science, Idaho Falls, Idaho, USA 2 Boise State University, Microscopy and Characterization Suite, Idaho Falls, Idaho, USA 3 Idaho National Laboratory, Idaho Falls, Idaho, USA 4 University of Texas San Antonio, Department of Physics and Astronomy, San Antonio, Texas, USA *Corresponding author: haiyanz@uidaho.edu; elizabeth.soobywood@utsa.edu Tri-structural Isotropic (TRISO) particle fuel is the preferred choice for the newest and next-generation high-temperature nuclear reactors due to its robust construction [1]. The fuel design effectively contains fission products inside the particle at extremely high temperatures [2]. However, the effect of transition metal fission products on fuel performance and structural integrity remains largely unknown, creating uncertainties in predicting fuel performance and potential failure mechanisms [2]. For example, palladium (Pd) has a strong tendency to form intermetallic phases with uranium (U). These new phases tend to be hard and brittle which could lead to fracture of fuel kernel during irradiation [3,4]. Pd is not normally produced in high concentrations in normal fission reactions however, driving the production of Pd into the locality of a Uranium Oxycarbide (UCO) nuclear fuel provides an opportunity to closely observe the diffusion and chemical interactions. This study focuses on detailed transmission electron microscopy characterization of the intermetallic phases formed by the interaction between a UCO kernel and a Pd bar after annealing at 1100 °C for 100 hours. Figure 1 provides an overview of the UCO kernel in contact with the Pd bar. The UCO-Pd sample surface was examined using a Focused Ion Beam (FIB) Quanta 3D FEG FEI in VCD detector mode at 10kV, 83pA to reveal surface features. Several key surface features in the interaction region were observed including: (1) a small area with dendritic microstructure, (2) color contrast near the UCO kernel and Pd boundary, and (3) darker and lighter regions throughout the sample surface. To analyze diffusion behavior, FIB was used to prepare lamellae from five different areas of the UCO-Pd sample, as well as one for the as-received sample. These lamellae were examined using a Scanning Transmission Electron Microscope ThermoFisher Spectra 300 (STEM-Spectra). Energy Dispersive Spectroscopy results confirmed the diffusion between the UCO fuel and Pd bar. Figure 2 shows the identified phases of UC, UO2, and Pd dispersed throughout the interaction region. It was also found that the Pd concentration decreases as the radial distance from the UCO-Pd interface increases. The Pd concentration was 36.93% atomic fraction 11µm from the interaction region then decreased to 7.51% atomic fraction at 257 µm away from the interaction region. Figure 3 shows how concentrations of U and Pd vary across the interaction zone, highlighting the extent of diffusion. This study confirms that Pd interacts with surrounding material to form U-Pd phase and diffusion zones. These diffusion zones vary in composition depending on its radial distance from the point of contact with the Pd bar. These findings contribute to a deeper understanding of the fission product behavior in high temperature nuclear fuels, aiding in the prediction and mitigation of potential fuel degradation mechanisms. A B C Fig. 1. SEM micrographs of UCO fuel kernel in contact with solid Pd bar and the lift out locations. Figure 1A shows UCO fuel kernel in contact with solid Pd bar. Figure 1B shows a higher magnification image of the UCO fuel-Pd interaction zone. Figure 1C shows lift out sites for the lamellae. A B C Fig 2. EDS maps reveal the distribution of U, O, and Pd in location 3. Figure 2A shows the distribution of uranium. Figure 2B shows the distribution of oxygen. Figure 2C shows the distribution of palladium. A B C Fig 3. Palladium and uranium concentration across interaction zone in location 2. Figure 3A shows EDS map of lift out number 2. Figure 3B shows a zoomed in EDS map taken from the interaction zone. Figure 3C shows a line graph of uranium and palladium concentrations across the interaction zone. References: 1. B.E. Wells, N.R. Phillips, K.J. Geelhood. Pacific West Laboratory. (2021). TRISO Fuel: Properties and Failure Modes. https://www.nrc.gov/docs/ML2117/ML21175A152.pdf (Accessed January 16, 2025). 2. American Nuclear Society. TRISO Fuel Development Progresses in INL, ORNL. https://www.gen-4.org/gif/upload/docs/application/pdf/2014-03/nov13nn_fuel_reprint.pdf (Accessed January 16, 2025) 3. Clark R.A., M.A. Con

36 - MATERIALS SCIENCE↗

Evaluation of radiation hardness of semiconductor materials against alpha particles for an API detector

An Associated Particle Imaging (API) system consists of a high vacuum chamber where deuterium ions are accelerated on a tritium-loaded target, resulting in alpha particles and neutrons emitted back-to-back, the latter escaping the chamber and used, for example, for tomography of a high-Z sample. An accurate determination of the alpha position is crucial to determine the trajectory of the neutron. Existing API systems have several limitations which a semiconductor-based API detector placed inside the vacuum chamber should not present. The semiconductor material can be either silicon or diamond. In particular, large and fast signals are generated by the alpha interactions in these materials. A pixelated API detector will measure the time and hit position of the alphas produced in the reaction. However, during the lifetime of the generator, the semiconductor detector will be exposed to an intense flux of alpha particles that will degrade its performance over time. To assess the radiation hardness of silicon and diamond against the alpha particles, we exposed single diodes made of either of the two materials to a 5 MeV alpha flux generated by an 241Am radioactive source. During irradiation, the diodes were biased and mounted on current-sensitive preamplifier boards. We have therefore been able to measure insitu the evolution of the waveforms as the damage was accumulating in their substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Feschenko BSM and Fast Faraday Cup with Low Energy Ion Beams

A comparison between Fast Faraday Cup and Feschenko longitudinal bunch shape detectors was recently performed at HELIAC Advanced Demonstrator beamline at GSI. Feschenko bunch shape monitor (BSM) uses the time to space conversion by means of secondary electrons emitted from a wire correlated to a rf deflector, while the fast Faraday cup (FFC) measures the deposited charge in a cup geometry matched to 50 Ohm. The FFC design aims to minimize the bunch shape dilution due to field polarization and secondary electrons produced on irradiation. An He¹⁺ with 100 µA average current and 1.4 MeV/u kinetic energy is utilized for this comparison. A buncher upstream of the detectors was operated to focus the beam longitudinally. The results are discussed in this contribution.

43 PARTICLE ACCELERATORS↗

Methylammonium Lead Tribromide Single Crystal Detectors towards Robust Gamma-Ray Photon Sensing

In recent years, hybrid perovskite single crystalline solid-state detectors have shown promise in γ-ray spectroscopy. Here, the γ-ray photon induced electrical pulses are investigated, which are produced by perovskite solid-state detectors made with the commonly used methylammonium lead tribromide crystals with chlorine incorporation. Under low electric field detector operation, slow pulses generated by γ-rays with average rise times of 65 µs are observed, which decreases to 20 µs when a higher electrical field of 500 V cm -1 is applied. However, the baseline becomes noisy quickly, which prevents collection of clean pulses for spectra construction. Further, by systematically measuring the temperature dependence and current–voltage characteristics, such instability is attributed to the local ion migration under electrical field creating a fluctuating dark noise, which presents a major challenge in perovskite γ-ray detector technologies. It is demonstrated that cycling the bias between positive and negative polarity can stabilize the detector, allowing for longer periods of pulse accumulation for generating energy resolved spectra with resolutions of ≈35% at 59.6 keV and ≈25% at 662 keV at room temperature. The study indicates that the main limiting factors of perovskite-based γ-ray detectors are slow rise times and bias instability. Finally, these challenges must be properly addressed to achieve reproducible, high-resolution γ-ray detection.

47 OTHER INSTRUMENTATION↗