Off-line ion source terminal for ISAC at TRIUMF

The off-line ion source (OLIS) terminal consists of a microwave cusp ion source, either a surface ion source or a hybrid surface-arc discharge ion source and an electrostatic switch that allows selecting any one of the sources without mechanical intervention. These sources provide variety of beams to ISAC experiments, for commissioning the accelerators, for setting up the radioactive experiments, and for tuning the beam lines. The microwave ion source has been operational since 1995 and provides singly and doubly charged beams from various stable isotopes for many ISAC experiments at high and low energy areas. Originally its prime goal was to provide beams from gaseous elements, but later two ovens and a sputtering system were added in order to provide beams from liquids and from solids. The surface ion source installed in 2002 can provide low energy spread beams from alkali and semialkali elements. It also has three separate ovens and an ionizer. Therefore, it can provide three different temperature regions simultaneously to provide different beams to ISAC. It is mainly used for laser spectroscopy experiments and other experiments, which require a finite beam quality. A hybrid surface-arc discharge ion source was also developed and installed in order to meet specific demands from experiments. This source terminal is now automated for start up and for mass selection. It is capable of providing stable beams for months without maintenance and it is also capable of providing negative ion beams if required. To date, over 40 different isotopes including many rear isotopes were delivered to various experiments from the OLIS source terminal. Performances of the ion sources and some of the results are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion Source Development for Ultratrace Detection of Uranium and Thorium

A hot-cavity surface ionization source and a hot-cavity laser ion source are evaluated in terms of ionization efficiencies for generating ion beams of U and Th. The work is motivated by the need for more efficient ion sources for detecting ultratrace U and Th impurities in a copper matrix by mass spectrometry techniques such as accelerator mass spectrometry (AMS). The performances of the ion sources are characterized using uranyl nitrate and thorium nitrate sample materials and sample sizes of 20 - 40 g of U or Th. For the surface source, the dominant ion beams observed are UO+ or ThO+ and ionization efficiencies of 2-4% have been obtained with W and Re cavities. Three-step resonant photoionization of U atoms is studied and an ionization efficiency of 8.7% has been obtained with the laser ion source. The positive ion sources promise more than an order of magnitude more efficient than conventional Cs-sputter negative ion sources used for AMS. In addition, the laser ion source is highly selective and effective in suppressing interfering and ions. Work is in progress to improve the efficiencies of both positive ion sources.

Liu, Yuan↗

Digital twin framework for PIP-II linac: AI-driven multi-scale modeling from ion source to 800 MeV

The PIP-II superconducting linac at Fermilab is designed to deliver multi-megawatt proton beams for neutrino physics and other high-intensity applications. To expedite commissioning and enhance operational reliability, we have developed an EPICS-based data flow framework that seamlessly integrates digital twins (DT) with physical twins (PT). These digital twins comprise high-fidelity beam dynamics models or data-driven surrogate models connected to their physical counterparts through real-time diagnostics and advanced machine-learning algorithms.Central to this framework is Linac_Gen, an accelerated simulation tool that incorporates convolutional neural networks, random forests, and genetic algorithms to provide up to a tenfold speedup in optimizing the accelerator geometry model. An EPICS translator layer ensures interoperability by efficiently mapping lattice parameters across diverse simulation platforms.Our EPICS-based framework supports multiple operational modes—monitoring, passive learning, closed-loop control, and online learning—covering the entire machine lifecycle. By leveraging HPC resources and multi-objective optimization techniques, the digital twin enables adaptive trajectory correction, real-time fault detection, and predictive modeling of beam stability. This comprehensive approach paves the way for robust, high-intensity operation and data-driven accelerator R&D at Fermilab.

Pathak, Abhishek [Fermilab]↗

Recent progress on the superconducting ion source VENUS

The 28 GHz Ion Source VENUS (versatile ECR for nuclear science) is back in operation after the superconducting sextupole leads were repaired and a fourth cryocooler was added. VENUS serves as an R and D device to explore the limits of electron cyclotron resonance source performance at 28 GHz with its 10 kW gryotron and optimum magnetic fields and as an ion source to increase the capabilities of the 88-Inch Cyclotron both for nuclear physics research and applications. The development and testing of ovens and sputtering techniques cover a wide range of applications. Recent experiments on bismuth demonstrated stable operation at 300 e{mu}A of Bi{sup 31+}, which is in the intensity range of interest for high performance heavy-ion drivers such as FRIB (Facility for Rare Isotope Beams). In addition, the space radiation effects testing program at the cyclotron relies on the production of a cocktail beam with many species produced simultaneously in the ion source and this can be done with a combination of gases, sputter probes, and an oven. These capabilities are being developed with VENUS by adding a low temperature oven, sputter probes, as well as studying the RF coupling into the source.

43 PARTICLE ACCELERATORS↗

Generation of multi-charged high current ion beams using the SMIS 37 gas-dynamic electron cyclotron resonance (ECR) ion source

A gas-dynamic ECR ion source (GaDIS) is distinguished by its ability to produce high current and high brightness beams of moderately charged ions. Contrary to a classical ECR ion source where the plasma confinement is determined by the slow electron scattering into an empty loss-cone, the higher density and lower electron temperature in a GaDIS plasma lead to an isotropic electron distribution with the confinement time determined by the prompt gas-dynamic flow losses. As a result, much higher ion fluxes are available, however a decrease in the confinement time of the GaDIS plasma lowers the ion charge state. The gas-dynamic ECR ion source concept has been successfully realized in the SMIS 37 experimental facility operated at the Institute of Applied Physics, Russia. The use of high-power (~100 kW) microwave (37.5 GHz) radiation provides a dense plasma (~10 13 cm -3 ) with a relatively low electron temperature (~50- 100 eV) and allows for the generation of high current (~1 A/cm 2 ) beams of multi-charged ions. In this work we report on the present status of the SMIS 37 ion source and discuss the advanced numerical modeling of ion beam extraction using the particle-in-cell code WARP

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics and modeling of an end-Hall (gridless) ion source

In an end-Hall source, an ion beam is extracted from a magnetized plasma and accelerated by the plasma electric field without grids. The principle of end-Hall sources is similar to that of Hall effect thrusters (or closed-drift thrusters), but their design is optimized for processing applications (ion beam assisted deposition or substrate cleaning) rather than propulsion. The beam divergence is larger in end-Hall ion sources, and these sources can operate at low ion energies. Although end-Hall sources are commonly used in the surface processing industry, no detailed modeling of these sources is available, and their operation is quite empirical. In this paper, a self-consistent, two-dimensional, quasineutral model of an end-Hall ion source is developed and used in order to improve the understanding of the basic physics of these plasma sources and to quantify the parameters controlling the properties of the extracted ion beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Operation and development status of the J-PARC ion source

A cesium-free H{sup −} ion source driven with a LaB{sub 6} filament is being operated at the Japan Proton Accelerator Research Complex (J-PARC) without any serious trouble since the restoration from the March 2011 earthquake. The H{sup −} ion current from the ion source is routinely restricted approximately 19 mA for the lifetime of the filament. In order to increase the beam power at the linac beam operation (January to February 2013), the beam current from the ion source was increased to 22 mA. At this operation, the lifetime of the filament was estimated by the reduction in the filament current. According to the steep reduction in the filament current, the break of the filament was predicted. Although the filament has broken after approximately 10 h from the steep current reduction, the beam operation was restarted approximately 8 h later by the preparation for the exchange of new filament. At the study time for the 3 GeV rapid cycling synchrotron (April 2013), the ion source was operated at approximately 30 mA for 8 days. As a part of the beam current upgrade plan for the J-PARC, the front end test stand consisting of the ion source and the radio frequency quadrupole is under preparation. The RF-driven H{sup −} ion source developed for the J-PARC 2nd stage requirements will be tested at this test stand.

43 PARTICLE ACCELERATORS↗

Development of Compact Electron Cyclotron Resonance Ion Source with Permanent Magnets for High-Energy Carbon-Ion Therapy

Heavy-ion cancer treatment is being carried out at the Heavy Ion Medical Accelerator in Chiba (HIMAC) with 140 to 400 MeV/n carbon ions at National Institute of Radiological Sciences (NIRS) since 1994. At NIRS, more than 4,000 patients have been treated, and the clinical efficiency of carbon ion radiotherapy has been demonstrated for many diseases. A more compact accelerator facility for cancer therapy is now being constricted at the Gunma University. In order to reduce the size of the injector (consists of ion source, low-energy beam transport and post-accelerator Linac include these power supply and cooling system), an ion source requires production of highly charged carbon ions, lower electric power for easy installation of the source on a high-voltage platform, long lifetime and easy operation. A compact Electron Cyclotron Resonance Ion Source (ECRIS) with all permanent magnets is one of the best types for this purpose. An ECRIS has advantage for production of highly charged ions. A permanent magnet is suitable for reduce the electric power and cooling system. For this, a 10 GHz compact ECRIS with all permanent magnets (Kei2-source) was developed. The maximum mirror magnetic fields on the beam axis are 0.59 T at the extraction side and 0.87 T at the gas-injection side, while the minimum B strength is 0.25 T. These parameters have been optimized for the production of C{sup 4+} based on experience at the 10 GHz NIRS-ECR ion source. The Kei2-source has a diameter of 320 mm and a length of 295 mm. The beam intensity of C{sup 4+} was obtained to be 618 e{mu}A under an extraction voltage of 30 kV. Outline of the heavy ion therapy and development of the compact ion source for new facility are described in this paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pure Material Vapor Source by Induction Heating Evaporator for an Electron Cyclotron Resonance Ion Source

Multiply charged iron ions are produced from solid pure material in an electron cyclotron resonance (ECR) ion source. We develop an evaporator by using induction heating with the induction coil which is made from bare molybdenum wire and surrounding the pure iron rod. We optimize the shape of induction heating coil and operation of rf power supply. We conduct experiment to investigate reproducibility and stability in the operation and heating efficiency. Induction heating evaporator produces pure material vapor, because materials directly heated by eddy currents have non-contact with insulated materials which are impurity gas sources. The power and the frequency of the induction currents range from 100 to 900 W and from 48 to 23 kHz, respectively. The working pressure is about 10{sup -4} to 10{sup -3} Pa. We measure temperature of iron rod and film deposition rate by depositing iron vapor to crystal oscillator. We confirm stability and reproducibility of evaporator enough to conduct experiment in ECR ion source. We can obtain required temperature of iron under maximum power of power supply. We are aiming the evaporator higher melting point material than iron.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental performance of a microwave cavity plasma disk ion source

The detailed description and performance characteristics of a microwave ion source are presented. This ion source utilizes an internally tuned, single-mode (or selective multimode) cylindrical cavity applicator to focus and match microwave energy into a disk-shaped discharge zone. The combination of mode focus control and variable, internal cavity matching allows the efficient operation and beam extraction over a wide range of pressures, powers and gaseous inputs. Experimental measurements of ion beam current versus accelerating voltage and input microwave power in xenon and oxygen gas are presented. Ion source specific energy and mass utilization versus experimental variables are also determined. The experimental performance demonstrates the ability of this ion source to extract an ion beam with a well matched, stable, and continuous operation over a wide range of input gases, low pressures, and over input gas flow rates in excess of 100 to a few sccm. Double Langmuir probe measurements in xenon gas indicate high degrees of ionization, and electron and ion concentrations in excess of 100 critical densities in the microwave discharge zone. This ion source has many potential uses such as spacecraft electric propulsion, material ion beam processing, and neutral beam ion sources.

Root, J.↗

Design of a compact electron cyclotron resonance ion source for medium charge state light ions

At the Australian Nuclear Science and Technology Organization we are developing a new isotope ratio mass spectrometer based on the measurement of multiple charge state ions. We have carried out a review of our existing ECR ion source and identified a number of design flaws. For the new instrument, we are producing a new ECR source and have refined the design, in particular by using 3D simulations to improve the magnetic confinement field and by a combination of simulations and experiments to improve the design of the microwave coupling.

43 PARTICLE ACCELERATORS↗

Experimental study of the spatial structure of high-energy ion sources in micropinch

Images of ion sources in the plasma of a micropinch discharge were recorded. The most intense ion source was found to be a Greater-Than-Or-Slanted-Equal-To 1-mm-diameter 3-mm-long anode region. The main contribution to the images is made by single-charged ions of the plasma-forming element with energies of 10-50 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser ion sources for radioactive beams (invited)

Resonant ionisation laser ion sources are nowadays extensively used, when available, at many leading on-line facilities. Moreover, new laser ion sources are now under development in most of the recent on-line facility projects under construction worldwide. This success is mainly due to the reliability, the ionization efficiency and the high purity that this type of source can achieve for the production of radioactive species and for a large range of chemical elements. Laser ion sources for radioactive beams gather many different systems such as dye laser or all-solid state titanium:sapphire laser systems, high or low repetition rates, hot cavities or gas cells, additional selectivity by using chemical techniques, or the LIST technique (laser ion source trap). In this paper, the physics of laser ion sources will be described with the current limitations and challenges for the future. An overview of the laser ion source facilities will be given, with an emphasis on the ongoing developments and perspectives on LIS.

43 PARTICLE ACCELERATORS↗

Comparison between single- and dual-electrode ion source systems for low-energy ion transport

Extraction of ions with energies below 100 eV has been demonstrated using a hot-cathode multi-cusp ion source equipped with extraction electrodes made of thin wires. Two electrode geometries, a single-electrode system, and a dual-electrode system were built and tested. The single-electrode configuration showed high ion beam current densities at shorter distances from the electrode but exhibited rapid attenuation as the distance from the electrode increased. Beam angular spread measurements showed similar beam divergence for both electrode configurations at low plasma densities. At high plasma densities and low extraction potentials, the single-electrode system showed the angular spread twice as large as that of the dual-electrode system. Energy distribution analyses showed a broader energy spread for ion beams extracted from a single-electrode set-up.

43 PARTICLE ACCELERATORS↗

Improvement of a plasma uniformity of the 2nd ion source of KSTAR neutral beam injector

The 2nd ion source of KSTAR (Korea Superconducting Tokamak Advanced Research) NBI (Neutral Beam Injector) had been developed and operated since last year. A calorimetric analysis revealed that the heat load of the back plate of the ion source is relatively higher than that of the 1st ion source of KSTAR NBI. The spatial plasma uniformity of the ion source is not good. Therefore, we intended to identify factors affecting the uniformity of a plasma density and improve it. We estimated the effects of a direction of filament current and a magnetic field configuration of the plasma generator on the plasma uniformity. We also verified that the operation conditions of an ion source could change a uniformity of the plasma density of an ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of Compact Penning Ion Source for Material Studies

Development of ion sources of various sizes has been carried out since a long back. Gaseous ions of different nature are being used in different field of research as well as industrial applications like surface modification, doping, surface etching, sputtering, production of nano size particles and focused ion beam etc. Out of various geometry and operation regime, due to compactness, ruggedness and long life, penning type ion sources are widely used in different field of research and applications. One such type of ion source was developed in our laboratory. Though this source was meant for neutron generation, using deuterium ions, the effectiveness for other purposes was investigated. The discharge characteristic was studied for different gases like, Deuterium, Helium, Nitrogen, Oxygen and Argon. The source being a self extracted type; the extracted ion current from the extraction aperture was measured using one faraday cup. In this paper we have discussed, the discharge characteristic and the extraction ion current for different type of gases.

07 ISOTOPE AND RADIATION SOURCES↗