Search NASA⌕ Search

SEARCH · Search NASA

Results for “Irradiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Monochromatic Measurements of the JPSS-1 VIIRS Polarization Sensitivity

Polarization sensitivity is a critical property that must be characterized for spaceborne remote sensing instruments designed to measure reflected solar radiation. Broadband testing of the first Joint Polar-orbiting Satellite System (JPSS-1) Visible Infrared Imaging Radiometer Suite (VIIRS) showed unexpectedly large polarization sensitivities for the bluest bands on VIIRS (centered between 400 and 600 nm). Subsequent ray trace modeling indicated that large diattenuation on the edges of the bandpass for these spectral bands was the driver behind these large sensitivities. Additional testing using the National Institute of Standards and Technologies Traveling Spectral Irradiance and Radiance Responsivity Calibrations Using Uniform Sources was added to the test program to verify and enhance the model. The testing was limited in scope to two spectral bands at two scan angles; nonetheless, this additional testing provided valuable insight into the polarization sensitivity. Analysis has shown that the derived diattenuation agreed with the broadband measurements to within an absolute difference of about0.4 and that the ray trace model reproduced the general features of the measured data. Additionally, by deriving the spectral responsivity, the linear diattenuation is shown to be explicitly dependent on the changes in bandwidth with polarization state.

Monochromatic↗

The NASA Space Radiation Laboratory

The Space Radiation Element (SRE) of the Human Research Program (HRP) aims to establish a robust biospecimen and tissue sharing collection (BTSC) to improve sample collection, tracking, access, distribution, and usability to maximize scientific return with intention. Future missions to the Moon, Mars, and beyond will require the appropriate characterization and mitigation of the many of the health risks associated with cosmic radiation exposure. An ongoing partnership between the National Aeronautics and Space Agency (NASA) and the Office of Science for the U.S. Department of Energy (DOE) has established the NASA Space Radiation Laboratory (NSRL) at the DOE Brookhaven National Laboratory (BNL) to create a space radiation ground-analog. NSRL provides the capability to use simulated space radiation with high energy ion beams for assessment of biological outcomes relevant space radiation risks as well as electronics testing for avionics safety. Current NSRL irradiation capabilities include a variety of exposure variables available for experimental needs: - Up to approximately 10 Gy/min dose-rates with a 20 × 20 cm 2 beam area. - Down to several hundred particles within a 60 × 60 cm 2 beam area. - Dose fractionation across multiple days is also possible. - For most radiobiology experiments the exposure structure, referred to as “spills”, has a 4 second repetition time where ions are extracted uniformly during a 0.3-0.4 second spill, followed by a ~3.6 second recovery time when the beam is off. - Both single or mixed-beam field irradiations are possible including a full 33-beam GCRSim and 6-beam SimGCRSim. Biological experiment capabilities: Two labs for Cell/tissue culture procedures can be conducted in two lab spaces with a separate lab available for sample processing that contains two chemical fume hoods. Sixteen fully equipped cell culture laboratories are available in the NSRL’s Long Term Support area in the Medical Building. The current vivarium configuration can support approximately 8,000 rodents/year for animal-based experiments. The NSRL area animal husbandry system includes five caging racks with 48 spaces in each coupled to a ventilation/filtration system in largest room, and two smaller rooms with conventional caging systems. Schedule: The NSRL is nominally open for experiment scheduling during three runs per year; Spring (March – May), Summer (May - June), and Fall (Sept – Nov). NASA funding is not required for biological and electronic testing experiments at the NSRL.

Jason M Weeks↗

A guideline for heavy ion radiation testing for Single Event Upset (SEU)

A guideline for heavy ion radiation testing for single event upset was prepared to assist new experimenters in preparing and directing tests. How to estimate parts vulnerability and select an irradiation facility is described. A broad brush description of JPL equipment is given, certain necessary pre-test procedures are outlined and the roles and testing guidelines for on-site test personnel are indicated. Detailed descriptions of equipment needed to interface with JPL test crew and equipment are not provided, nor does it meet the more generalized and broader requirements of a MIL-STD document. A detailed equipment description is available upon request, and a MIL-STD document is in the early stages of preparation.

Nichols, D. K.↗

Correlation of irradiation data using activation fluences and irradiation temperature.

A new method of correlating radiation damage data is tested using actual measured data taken from the open literature. This method, the activation fluence method, was found to be as accurate as other contemporary models with which it was compared. The new method also has several advantages over the other methods. The method employs a new entity, the activation fluence (time-integrated specific activation rate), as the independent variables in a regression model. Temperature at which the irradiation takes place is also a variable. Although the method was tested for a specific type of damage (change in nil-ductility transition temperature for A302-B steel) it has no inherent restrictions and is limited only by the imagination of the user.

Lynch, J. H.↗

Single Event Effect Testing of the SSDI SFF6661 N-Channel Power MOSFET

This irradiation campaign was performed to evaluate the destructive single event effect (SEE) susceptibility of a n-channel power MOSFET from SSDI for space-based instrumentation. Testing was performed at Michigan State University’s (MSU) Facility for Rate Isotope Beams (FRIB) using an LET of 50.5 MeV·cm 2 /mg

Landen D. Ryder↗

Coatings degradation, section VIII

Vacuum chambers for particle irradiation of thermal control coatings, and testing of paint samples of alkali silicates and methyl silicones

SILICONE↗

Heterogeneous phase reactions of Martian volatiles with putative regolith minerals

The chemical reactivity of several minerals thought to be present in Martian fines is tested with respect to gases known in the Martian atmosphere. In these experiments, liquid water is excluded from the system, environmental temperatures are maintained below 0 C, and the solar illumination spectrum is stimulated in the visible and UV using a xenon arc lamp. Reactions are detected by mass spectrometric analysis of the gas phase over solid samples. No reactions were detected for Mars nominal gas over sulfates, nitrates, chloride, nontronite clay, or magnetite. Oxidation was not observed for basaltic glass, nontronite, and magnetite. However, experiments incorporating SO2 gas an expected product of volcanism and intrusive volatile release - gave positive results. Displacement of CO2 by SO2 occurred in all four carbonates tested. These reactions are catalyzed by irradiation with the solar simulator. A calcium nitrate hydrate released NO2 in the presence of SO2. These results have implications for the cycling of atmospheric CO2, H2O, and N2 through the regolith.

Clark, B. C.↗

Large aperture interferometer with phase-conjugate self-reference beam

A large aperture self-referencing interferometer consisting of a Twyman-Green interferometer using a self-pumped phase conjugator in series with test section optics is described and experimentally demonstrated. This interferometer provides twice the fringe shift of a Mach-Zehnder (M-Z) interferometer for a given optical phase change induced within the test section. It also provides greater irradiance in the reference beam than does a similar series setup utilizing a M-Z interferometer incorporating a local reference beam. Whereas the ordinary interferometer records instantaneous conditions, the new one records overage conditions if a BaTiO3 crystal is used as the phase conjugator.

Howes, W. L.↗

Trends In Susceptibility To Single-Event Upset

Report provides nearly comprehensive body of data on single-event upsets due to irradiation by heavy ions. Combines new test data and previously published data from governmental and industrial laboratories. Clear trends emerge from data useful in predicting future performances of devices.

Nichols, Donald K.↗

Metal Standards for Waveguide Characterization of Materials

Rectangular-waveguide inserts that are made of non-ferromagnetic metals and are sized and shaped to function as notch filters have been conceived as reference standards for use in the rectangular- waveguide method of characterizing materials with respect to such constitutive electromagnetic properties as permittivity and permeability. Such standards are needed for determining the accuracy of measurements used in the method, as described below. In this method, a specimen of a material to be characterized is cut to a prescribed size and shape and inserted in a rectangular- waveguide test fixture, wherein the specimen is irradiated with a known source signal and detectors are used to measure the signals reflected by, and transmitted through, the specimen. Scattering parameters [also known as "S" parameters (S11, S12, S21, and S22)] are computed from ratios between the transmitted and reflected signals and the source signal. Then the permeability and permittivity of the specimen material are derived from the scattering parameters. Theoretically, the technique for calculating the permeability and permittivity from the scattering parameters is exact, but the accuracy of the results depends on the accuracy of the measurements from which the scattering parameters are obtained. To determine whether the measurements are accurate, it is necessary to perform comparable measurements on reference standards, which are essentially specimens that have known scattering parameters. To be most useful, reference standards should provide the full range of scattering-parameter values that can be obtained from material specimens. Specifically, measurements of the backscattering parameter (S11) from no reflection to total reflection and of the forward-transmission parameter (S21) from no transmission to total transmission are needed. A reference standard that functions as a notch (band-stop) filter can satisfy this need because as the signal frequency is varied across the frequency range for which the filter is designed, the scattering parameters vary over the ranges of values between the extremes of total reflection and total transmission. A notch-filter reference standard in the form of a rectangular-waveguide insert that has a size and shape similar to that of a material specimen is advantageous because the measurement configuration used for the reference standard can be the same as that for a material specimen. Typically a specimen is a block of material that fills a waveguide cross-section but occupies only a small fraction of the length of the waveguide. A reference standard of the present type (see figure) is a metal block that fills part of a waveguide cross section and contains a slot, the long dimension of which can be chosen to tailor the notch frequency to a desired value. The scattering parameters and notch frequency can be estimated with high accuracy by use of commercially available electromagnetic-field-simulating software. The block can be fabricated to the requisite precision by wire electrical-discharge machining. In use, the accuracy of measurements is determined by comparison of (1) the scattering parameters calculated from the measurements with (2) the scattering parameters calculated by the aforementioned software.

Lambert, Kevin M.↗

RBE of Energetic Iron Ions for the Induction of Early and Late Chromosome Aberrations in Different Cell Types

Numerous published studies have reported the RBE values for chromosome chromosomes induced by charged particles of different LET. The RBE for chromosome aberrations in human lymphocytes exposed ex vivo showed a similar relationship as the quality factor for cancer induction. Consequently, increased chromosome aberrations in the astronauts' white blood cells post long-duration missions are used to determine the biological doses from exposures to space radiation. The RBE value is known to be very different for different types of cancer. Previously, we reported that the RBE for initial chromosome damages was high in human lymphocytes exposed to Fe ions. After multiple cell divisions post irradiation, the RBE was significantly smaller. To test the hypothesis that the RBE values for chromosome aberrations are different between early and late damages and also different between different cell types, we exposed human lymphocytes ex vivo, and human fibroblast cells and human mammary epithelial cells in vitro to 600 MeV/u Fe ions. Post irradiation, the cells were collected at first mitosis, or cultured for multiple generations for collections of remaining or late arising chromosome aberrations. The chromosome aberrations were quantified using fluorescent in situ hybridization (FISH) with whole chromosome specific probes. This study attempts to offer an explanation for the varying RBE values for different cancer types.

Zhang, Ye↗

Radiation Tests of Single Photon Avalanche Diode for Space Applications

Single photon avalanche diodes (SPADs) have been recently studied as photodetectors for applications in space missions. In this presentation we report the results of radiation hardness test on large area SPAD (actual results refer to SPADs having 500 micron diameter). Dark counts rate as low as few kHz at −10 degC has been obtained for the 500 micron devices, before irradiation. We performed bulk damage and total dose radiation tests with protons and gamma-rays in order to evaluate their radiation hardness properties and their suitability for application in a Low Earth Orbit (LEO) space mission. With this aim SPAD devices have been irradiated using up to 20 krad total dose with gamma-rays and 5 krad with protons. The test performed show that large area SPADs are very sensitive to proton doses as low as 2×10(exp 8) (1 MeV eq) n/cm2 with a significant increase in dark counts rate (DCR) as well as in the manifestation of the "random telegraph signal" effect. Annealing studies at room temperature (RT) and at 80 degC have been carried out, showing a high decrease of DCR after 24-48 h at RT. Lower protons doses in the range 1-10×10(exp 7) (1 MeV eq) n/cm(exp 2) result in a lower increase of DCR suggesting that the large-area SPADs tested in this study are well suitable for application in low-inclination LEO, particularly useful for gamma-ray astrophysics.

radiation hardness↗

Space qualification of UV and IR reflecting coverslides for GaAs solar cells

As part of the space qualification effort for blue-red reflecting coverslides designed for use with GaAs solar cells, the first long-term (3000 hours) UV testing of unirradiated and 1 MeV electron-irradiated GaAs solar cells, with 4 types of multilayer-coated coverslides to reduce operating temperature, has produced some unexpected results. Important conclusions from this study, which includes two parallel tests, are as follows: (1) All of the GaAs solar cells with multilayer-coated coverslides display UV degradation. The laboratory data, extrapolated to 10 years in orbit, point to a significant loss mechanism from a combination of absorption and a reduction in optical match in such coatings from this portion of the space environment; (2) The effects of contamination in a vacuum system, on the measured degradation in solar-cell short-circuit current during a UV test, depend upon the type of coverslide coatings present on the coverslide surfaces. This has implications for both coated coverslides and optical solar reflectors (OSR's) in space; and (3) Because of the observed trends in this test and uncertainties in the extrapolation of data for multilayer coated coverslides, the use of any multilayer-coated coverslides for extended missions (greater than 1 year) cannot be recommended without prior flight testing.

Meulenberg, Andrew↗

Calibration of solar cells by the reference cell method - The spectral mismatch problem

The calibration of solar cells by means of solar simulators and calibrated reference cells has always been faced with the problem of errors due to source spectral irradiance mismatch and cell spectral response mismatch. A general expression is derived in this paper to enable calculation of mismatch error. The information required to make this calculation is the relative spectra responses of the test and reference cells, and the relative spectral irradiance of the simulator (over the spectral range defined by cell response). The spectral irradiance of the solar standard is assumed given. Experimental results are presented.

Seaman, C. H.↗

Initial comparison of SSPM ground test results and flight data to NASCAP simulations

The satellite surface potential monitor (SSPM) has been developed for the P78-2 SCATHA (Spacecraft Charging At The High Altitudes) satellite to determine the response of selected spacecraft materials to charged-particle environmental fluxes. Since the monitor infers total surface voltages from a single point on the interior side of insulators, a ground simulation program was undertaken to develop analytical techniques to model the monitors and to obtain an experimental calibration of the relationship between the flight measurement techniques and actual measurements. The experimental testing was conducted using monoenergetic electron beams irradiating samples in the dark. An analytical computer model was developed in the NASCAP (NASA Charging Analyzer Program) code. The analytical model material properties for Kapton that controlled backscatter and secondary yield were adjusted to obtain a single set of values that produced reasonable fits for both voltages and currents. The analytical techniques developed in the ground technology investigation have been applied to space flight conditions. Predictions were compared with limited flight data. The agreement is very good indicating that the technique, and NASCAP, can be used to predict spacecraft material charging behavior. Details of the testing, the analytical modelling technique and flight data comparisons are presented.

Stevens, N. J.↗

Algorithms for Ocean Bottom Albedo Determination from In-Water Natural Light Measurements

A method for determining ocean bottom optical albedo, R-sub b, from in-water upward and downward irradiance measurements at a shallow site is presented, tested, and compared with a more familiar approach that requires additional measurements at a nearby deep-water site. Also presented are two new algorithms for the estimation of R-sub b from measurements of the downward irradiance and vertically upward radiance.

Leathers, Robert A.↗