Search NASA⌕ Search

SEARCH · Search NASA

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

RADIATION DOSE SIMULATIONS FOR JEFFERSON LAB’S PERMANENT MAGNET RESILIENCY LDRD STUDY

In late 2023, Thomas Jefferson National Accelerator Facil- ity (Jefferson Lab) funded a Laboratory Directed Research and Development (LDRD) grant dedicated to investigating the impact of radiation on permanent magnet materials. This research initiative is specifically geared towards assessing materials slated for use in the CEBAF energy upgrade. The experimental approach involves strategically placing perma- nent magnet samples throughout the accelerator, exposing them to varying radiation doses. The simulation code BD- SIM is used to first validate the data and then to simulate the effects on future higher energy passes to study the degra- dation effects on the permanent magnets. In this paper we present the progress of that work.

Deitrick, K.↗

SRF Cavity Fault Classification and Prediction at Jefferson Lab

Over the last few years several machine learning projects at Jefferson Lab have had a common focus to optimize operation of superconducting RF (SRF) cavities in the Continuous Electron Beam Accelerator Facility (CEBAF). In this talk we highlight work to identify and classify types of faults from C100-type cavities and then to extend those capabilities to provide real-time fault prediction. Early prediction may enable mitigation strategies to prevent some types of faults. In our approach we apply a two-step fault prediction pipeline. In the first step, a model distinguishes between faulty and normal signals. In the second step, signals flagged as faulty by the first model are classified into one of seven fault types based on learned signatures in the data. Initial results show that our model can successfully predict most fault types 200 ms before onset. In additional to model performance, we also highlight challenges in working with real-world data and challenges for deploying models.

Tennant, C.↗

The Generalized Parton Distribution Program at Jefferson Lab

Recent results on the Generalized Parton Distribution (GPD) program at Jefferson Lab (JLab) will be presented. The emphasis will be in the Hall A program aiming at measuring Q^2-dependences of different terms of the Deeply Virtual Compton Scattering (DVCS) cross section. This is a fundamental step before one can extract GPD information from JLab DVCS data. The upcoming program in Hall A, using both a 6 GeV beam (2010) and a 11 GeV beam (~2015) will also be described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a non-invasive, continuous polarimeter for Hall C at Jefferson Lab

The stringent requirements of the parity violating experimental program at Jefferson Lab necessitate an accurate knowledge of electron beam polarization. In particular, the tight error budget for the Qweak experiment currently in production in Hall C allows an error of only ±1% for the measurement of electron beam polarization. In order to achieve this, a Compton polarimeter has been recently built in Hall C and is being utilized as part of the polarimetry program. Compton polarimetry derives its analyzing power from the spin dependence of the γ-e interaction and requires a highly polarized coherent beam of photons with well known properties. I discuss the development and performance of a resonant optical cavity at a wavelength of 532~nm for use as a photon target and some of the difficulties encountered in the process, as well as the means of determining intra-cavity beam properties.

Jones, Donald↗

The Generalized Parton Distribution program in Hall A at Jefferson Lab

Recent results on the Generalized Parton Distribution (GPD) program at Jefferson Lab (JLab) will be presented. The emphasis will be in the Hall A program aiming at measuring Q2â dependences of different terms of the Deeply Virtual Compton Scattering (DVCS) cross section. This is a fundamental step before one can extract GPD information from JLab DVCS data. Neutral pion production will also be discussed and results from the CLAS collaboration will be shown. Finally, the upcoming program in Hall A, using both a 6 GeV beam ([approximate]2010) and a 11 GeV beam ([approximate]2015) will be described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetic calorimeter for the Heavy Photon Search Experiment at Jefferson Lab

The Heavy Photon Search Experiment (HPS) seeks to detect a hypothesised hidden sector boson, the A', predicted to be produced in dark matter decay or annihilation. Theories suggest that the A' couples weakly to electric charge through kinetic mixing, allowing it, as a result, to decay to Standard Matter (SM) lepton pair, which may explain the electron and positron excess recently observed in cosmic rays. Measuring the lepton pair decay of the A' could lead to indirect detection of dark matter. The HPS experiment is a fixed target experiment that will utilize the electron beam produced at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The detector set-up includes a silicon vertex tracker (SVT) and an Electromagnetic Calorimeter (ECal). The ECal will provide the trigger and detect e+e- pairs and its construction and testing forms the focus of this thesis. The ECal consists of 442 PbWO 4 - tapered crystals with a length 16cm and a 1.6x1.6cm 2 cross-section, stacked into a rectangular array and are coupled to Large Area APDs and corresponding pre-amplifiers. Supplementary to the ECal is a Light Monitoring System (LMS) consisting of bi-coloured LEDs that will monitor changes in APD gain and crystal transparency due to radiation damage. Before construction of the ECal each of the components were required to be individually tested to determine a number of different characteristics. Irradiation tests were performed on PbWO 4 ECal crystals and, as a comparison, one grown by a different manufacturer to determine their radiation hardness. A technique for annealing the radiation damage by optical bleaching, which involves injecting light of various wavelengths into the crystal, was tested using the blue LED from the LMS as a potential candidate. The light yield dependence on temperature was also measured for one of the PbWO 4 crystal types. Each APD was individually tested to determine if they functioned correctly and within the requirements of the experiment, then arranged into groups of similar gain at chosen applied voltages, for connection to High Voltage (HV) supplies. Each bi-coloured LED was also tested to determine if they functioned within the specifications of the experiment; including their signal quality at high frequency and their radiation hardness. The HPS crystals were recycled from a previous Jefferson Lab detector, the Inner Calorimeter from CLAS, which needed to be dismantled and reconditioned using various removal and cleaning techniques. The HPS ECal was then constructed in a new formation using a combination of different gluing and construction techniques, and initial functionality tests were performed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab

The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped Gd 2 SiO 5 crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pair spectrometer hodoscope for Hall D at Jefferson Lab

We present the design of the pair spectrometer hodoscope fabricated at Jefferson Lab and installed in the experimental Hall D. The hodoscope consists of thin scintillator tiles; the light from each tile is collected using wave-length shifting fibers and detected using a Hamamatsu silicon photomultiplier. Light collection was measured using relativistic electrons produced in the tagger area of the experimental Hall B.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MOeLLER experiment at Jefferson Lab: search for physics beyond the Standard Model

The MOeLLER experiment at Jefferson Lab will measure the parity-violating analyzing power A{sub z} in the scattering of 11 GeV longitudinally polarized electrons from the atomic electrons in a liquid hydrogen target (Moeller scattering). In the Standard Model a non-zero A{sub z} is due to the interference of the electromagnetic amplitude and the weak neutral current amplitude, the latter mediated by the Z{sup 0} boson. A{sub z} is predicted to be 35.6 parts per billion (ppb) at the kinematics of the experiment. It is the objective of the experiment to measure A{sub z} to a precision of 0.73 ppb. This result would yield a measurement of the weak charge of the electron Q{sub W}{sup e} to a fractional error of 2.3% at an average value Q{sup 2} of 0.0056 (GeV/c){sup 2}. This in turn will yield a determination of the weak mixing angle sin{sup 2{theta}}w with an uncertainty of {+-}0.00026(stat) {+-}0.00013(syst), comparable to the accuracy of the two best determinations at high energy colliders (at the Z{sup 0} pole). Consequently, the result could potentially influence the central value of this fundamental electroweak parameter, which is of critical importance in deciphering any signal of new physics that might be observed at the Large Hadron Collider (LHC). The measurement is sensitive to the interference of the electromagnetic amplitude with new neutral current amplitudes as weak as 10{sup -3} GF from as yet unknown high energy dynamics, a level of sensitivity unlikely to be matched in any experiment measuring a flavor and CP conserving process in the next decade. This provides indirect access to new physics at multi-TeV scales in a manner complementary to direct searches at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deep exclusive reactions at Jefferson Lab Hall A

Recent results on the Generalized Parton Distribution (GPD) program at Jefferson Lab (JLab) will be presented. The emphasis will be in the Hall A program aiming at measuring Q2-dependences of different terms of the Deeply Virtual Compton Scattering (DVCS) cross section. This is a fundamental step before one can extract GPD information from JLab DVCS data. The upcoming program in Hall A, using both a 6 GeV beam (2010) and a 11 GeV beam (≈ 2015) will also be described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress of ILC High Gradient SRF Cavity R&D at Jefferson Lab

Latest progress of ILC high gradient SRF cavity R&D at Jefferson Lab will be presented. 9 out of 10 real 9-cell cavities reached an accelerating gradient of more than 38 MV/m at a unloaded quality factor of more than 8 {center_dot} 109. New understandings of quench limitation in 9-cell cavities are obtained through instrumented studies of cavities at cryogenic temperatures. Our data have shown that present limit reached in 9-cell cavities is predominantly due to localized defects, suggesting that the fundamental material limit of niobium is not yet reached in 9-cell cavities and further gradient improvement is still possible. Some examples of quench-causing defects will be given. Possible solutions to pushing toward the fundamental limit will be described.

43 PARTICLE ACCELERATORS↗

Design of the Proposed Low Energy Ion Collider Ring at Jefferson Lab

The polarized Medium energy Electron-Ion Collider (MEIC) envisioned at Jefferson Lab will cover a range of center-of-mass energies up to 65 GeV. The present MEIC design could also allow the accommodation of low energy electron-ion collisions (LEIC) for additional science reach. This paper presents the first design of the low energy ion collider ring which is converted from the large ion booster of MEIC. It can reach up to 25 GeV energy for protons and equivalent ion energies of the same magnetic rigidity. An interaction region and an electron cooler designed for MEIC are integrated into the low energy collider ring, in addition to other required new elements including crab cavities and ion spin rotators, for later reuse in MEIC itself. A pair of vertical chicanes which brings the low energy ion beams to the plane of the electron ring and back to the low energy ion ring are also part of the design.

43 PARTICLE ACCELERATORS↗

Analysis of New High-Q0 SRF Cavity Tests by Nitrogen Gas Doping at Jefferson Lab

In order to refine systematic understanding and establish confident process control, Jefferson Lab has joined with partners to investigate and thoroughly characterize the dramatically higher Q0 of 1.3 GHz niobium cavities first reported by FNAL in 2013[1]. With partial support from the LCLS-II project, JLab has undertaken a parametric study of nitrogen doping in vacuum furnace at 800 °C followed by variable depth surface removal in the 5 - 20 μm range. Q0 above 3×1010 are typical at 2.0 K and 16 MV/m accelerating field. We report observations from the single cell study and current interpretations. In addition to the parametric single cell study, we also report on the ongoing serial testing of six nitrogen-doped 9-cell cavities as baseline prototypes for LCLS-II.

Palczewski, Ari D.↗

PC/104 Asyn Drivers at Jefferson Lab

Asyn Driver was applied for PC/104 IOC serial communication systems at Jefferson Lab. We chose the ines GPIB-PC/104-XL as the GPIB interface module and developed the low lever device driver that is compatible with the asynDriver. Instrument device support was created to provide access to the operating parameters of GPIB devices. Low level device driver for the serial communication board Model 104-COM-8SM was also developed to run under asynDriver. This serial interface board contains eight independent ports and provides effective RS-485, RS-422 and RS-232 multipoint communication. StreamDevice protocols were applied for the serial communications. The asynDriver in PC/104 IOC applications provides a standard interface between the high level device support and hardware level device drivers. This makes it easy to develop the GPIB and serial communication applications for PC/104 IOCs.

Yan, Jianxun↗

Study of Double Spin Asymmetries in Inclusive ep Scattering at Jefferson Lab

The spin structure of the proton has been investigated in the high Bjorken x and low momentum transfer Q 2 region. We used Jefferson Lab's polarized electron beam, a polarized target, and a spectrometer to get both the parallel and perpendicular spin asymmetries Apar and Aperp. These asymmetries produced the physics asymmetries A_1 and A_2 and spin structure functions g_1 and g_2. We found Q 2 dependences of the asymmetries at resonance region and higher-twist effects. Our result increases the available data on the proton spin structure, especially at resonance region with low Q 2 . Moreover, A_2 and g_2 data show clear Q 2 evolution, comparing with RSS and SANE-BETA. Negative resonance in A_2 data needs to be examined by theory. It can be an indication of very negative transverse-longitudinal interference contribution at W ~ 1.3 GeV. Higher twist effect appears at the low Q 2 of 1.9 GeV 2 , although it is less significant than lower Q 2 data of RSS. Twist03 matrix element d_2 was calculated using our asymmetry fits evaluation at Q 2 – 1.9 GeV 2 . D-bar_2 = -0.0087±0.0014 was obtained by integrating 0.47 ≤ x ≤ 0.87.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Examples of Mission-driven Data Science from Jefferson Lab and ACES

This presentation details mission-driven data science initiatives at Jefferson Lab and the Joint Institute for Advanced Computing on Environmental Studies (ACES). JLab, a U.S. Department of Energy Office of Science national laboratory, operates the Continuous Electron Beam Accelerator Facility (CEBAF), and is the lead institute for the new High Performance Data Facility (HPDF) Hub. The Joint Institute for ACES brings together interdisciplinary teams in health informatics, climate modeling, computer science, and physics to address environmental challenges, including flood modeling. The Hampton Roads region, particularly Norfolk and Virginia Beach, faces increasing flood risks, motivating the need for rapid, reliable, and risk-aware decision support. ACES’s flooding work has a focus on uncertainty quantification (UQ) and machine learning (ML) for coastal flood management. The work is motivated by the increasing vulnerability of communities such as Norfolk and Virginia Beach, Virginia, to frequent coastal flooding events, and the need for rapid, reliable decision support. The research develops computationally efficient ML surrogate models to forecast water levels and flooding risk. A central theme is the quantification and calibration of predictive uncertainty, especially for out-of-distribution (OOD) scenarios, using techniques such as Monte Carlo Dropout, Deep Ensembles, Gaussian Processes, and Deep Quantile Regression (DQR). The study demonstrates that distance-aware UQ is critical for reliable scientific AI, particularly in high-dimensional, safety-critical, and real-time applications.

McSpadden, Diana [Thomas Jefferson National Accele↗

The lead-glass electromagnetic calorimeters for the magnetic spectrometers in Hall C at Jefferson Lab

The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $\sigma/E \sim 6%/\sqrt E $, and pion/electron ($\pi/e$) separation of about 100:1 has been achieved in energy range 1 -- 5 GeV. Good agreement has been observed between the experimental and simulated energy resolutions, but simulations systematically exceed experimentally determined $\pi^-$ suppression factors by close to a factor of two. For the SHMS spectrometer presently under construction details on the design and accompanying GEANT4 simulation efforts are given. The anticipated performance of the new calorimeter is predicted over the full momentum range of the SHMS. Good electron/hadron separation is anticipated by combining the energy deposited in an initial (preshower) calorimeter layer with the total energy deposited in the calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗