Search NASA⌕ Search

SEARCH · Search NASA

Results for “LANGMUIR PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Fairfield Plume Measurement and Analysis on the NASA-300M and NASA-300MS

NASA is developing a 10- to 15-kW Hall thruster system to support future NASA missions. This activity is funded under the Space Technology Mission Directorate Solar Electric Propulsion Technology Demonstration Mission project. As a part of the development process, the NASA-300M, a 20-kW Hall thruster, was modified to incorporate the magnetic shielding concept and named the NASA-300MS. This activity was undertaken to assess the viability of using the magnetic shielding concept on a high-power Hall thruster to greatly reduce discharge channel erosion. This paper reports on the study to characterize the far-field plumes of the NASA-300M and NASA-300MS. Diagnostics deployed included a polarlyswept Faraday probe, a Wien filter (ExB probe), a retarding potential analyzer, and a Langmuir probe. During the study, a new, more accurate, integration method for analyzing Wien filter probe data was implemented and effect of secondary electron emission on the Faraday probe data was treated. Comparison of the diagnostic results from the two thrusters showed that the magnetically shielded version performed with ~2 percent higher voltage utilization efficiency, ~2 percent lower plume divergence efficiency, and ~2 percent lower mass utilization efficiency compared to the baseline version. The net change in efficiency is within the aggregate measurement uncertainty so the overall performance is roughly equal for the two versions of the thruster. Anode efficiency calculated from thrust stand measurement corroborates this finding.

Hall thruster↗

Design, Development, Implementation, and On-Orbit Performance of the Dynamic Ionosphere CubeSat Experiment Mission

Funded by the NSF CubeSat and NASA ELaNa programs, the Dynamic Ionosphere CubeSat Experiment (DICE) mission consists of two 1.5U (1.5 Unit) CubeSats which were launched into an eccentric low Earth orbit on October 28, 2011. Each identical spacecraft carries two Langmuir probes to measure ionospheric in-situ plasma densities, electric field probes to measure in-situ DC and AC electric fields, and a science grade magnetometer to measure in-situ DC and AC magnetic fields. Given the tight integration of these multiple sensors with the CubeSat platforms, each of the DICE spacecraft is effectively a sensor-sat capable of comprehensive ionospheric diagnostics. The use of two identical sensor-sats at slightly different orbiting velocities in nearly identical orbits permits the deconvolution of spatial and temporal ambiguities in the observations of the ionosphere from a moving platform. In addition to demonstrating nanosat-based constellation science, the DICE mission is advancing a number of groundbreaking CubeSat technologies including miniaturized mechanisms and high-speed downlink communications.

DICE↗

Farfield Plume Measurement and Analysis on the NASA-300M

NASA is developing a 15-kW Hall thruster to support future NASA missions. This activity is funded under the Space Technology Mission Directorate Solar Electric Propulsion Technology Demonstration project. As a part of the development process, the far-field plume characteristics of the NASA-300M, a 20-kW Hall thruster, were studied. The results will be used to study how various aspects of the operation of this thruster affect the overall performance. This data will be used to guide future design work and serve as a baseline for comparison to a magnetically shielded version of the NASA-300M that will be tested in the future. For this study, a far-field Faraday probe was swept in a polar fashion to map the ion current density. An ExB probe (Wien filter), two retarding potential analyzers, and a Langmuir probe were mounted at a fixed location on the thruster axis in the far-field plume. The data reduction method followed recommendations in recent studies by Brown, Reid, and Shastry with modifications that are tailored to the plasma plume environment of high-power Hall thrusters. Results from this and prior testing show that the plume is richer in doubly-charged ions, larger in spatial extent, and capable of greater probe heating than lower power thrusters. These characteristics require special treatment in experimental setup and data analysis, which will be the main focus of this paper. In particular, covered topics will include a new, more accurate, method of integration for analysis of the ExB probe data and effect of secondary electron emission on the Faraday probe data.

Huang, Wensheng↗

Results of rocket measurements of D-region ionization over Thumba in MAP

Under MAP, two rockets were launched from Thumba (8.5 N, 76.8 E) around 1030 hrs Lt with identical payloads on 7 and 10 March 1986 for D region studies. Positive ion densities were measured by spherical probe and Gerdien condenser and electron densities were measured by Langmuir probe and propagation experiments. In both flights a valley in ionization height profile was noticed around 83 km. The density of ionization at this altitude was about 4 x 10(2) cu cm. A detailed positive ion-chemical scheme was used to reproduce the measured ionization height profiles. The density of NO needed to reproduce the valley in ionization at 83 km came around 5 x 10(5) cu cm. A photochemical treatment without diffusion process was found inadequate to explain this value of NO. Calculations showed that the value of vertical eddy diffusion needed to reproduce the value of NO was around 10(6)sq cm/s. Interestingly, the same value of eddy diffusion coefficient was obtained when derived in the manner described by Thrane and his coworkers using only the positive ion current data of spherical probes.

Chakrabarty, D. K.↗

Ionospheric Results with Sounding Rockets and the Explorer VIII Satellite (1960 )

A review is made of ionospheric data reported since the IGY from rocket and satellite-borne ionospheric experiments. These include rocket results on electron density (RF impedance probe), D-region conductivity (Gerdien condenser), and electron temperature (Langmuir probe). Also included are data in the 1000 kilometer region on ion concentration (ion current monitor) and electron temperature from the Explorer VIII Satellite (1960 xi). The review includes suggestions for second generation experiments and combinations thereof particularly suited for small sounding rockets.

Bourdeau, R. E.↗

Hollow Cathode and Keeper-region Plasma Measurements Using Ultra-fast Miniature Scanning Probes

In order to support the development of comprehensive performance and life models for future deep space missions that will utilize ion thrusters, we have undertaken a study of the plasma structure in hollow cathodes using an new pneumatic scanning probe diagnostic. This device is designed to insert a miniature probe directly into the hollow cathode orifice from either the upstream insert region in the interior of the hollow cathode, or from the downstream keeper-plasma region at the exit of the hollow cathode, to provide complete axial profiles of the discharge plasma parameters. Previous attempts to diagnose this region with probes was Limited by the melting of small probes in the intense discharge near the orifice, or caused significant perturbation of the plasma by probes large enough to survive. Our new probe is extremely compact, and when configured as a single Langmuir probe, the ceramic tube insulator is only 0.5mm in diameter and the current collecting conductor has a total area of 0.002 cm2. A series of current-voltage characteristics are obtained by applying a rapid sawtooth voltage waveform to the probe as it is scanned by the pneumatic actuator into and out of the plasma region, The bellow-sealed pneumatic drive scans the probe 4 cm in the cathode insert region and 10 cm in the anode/keeper plasmas region at average speeds of about 1 mm/msec, and the residence time at the end of the insertion stroke in the densest part of the plasma near the orifice is measured to be only 10 msec. Since the voltage sweep time is fast compared to the motion of the probe, axial profiles of the plasma density, temperature and potential with reasonable spatial resolution are obtained. Measurements of the internal cathode pressures and the axial plasma-parameter profiles for a hollow cathode operating at discharge currents of up to 35 A in xenon will be presented.

plasma generation↗

New insights on divertor parallel flows,E × B drifts, and fluctuations from in situ, two-dimensional probe measurement in the Tokamak à Configuration Variable

Abstract In situ , two-dimensional (2D) Langmuir probe measurements across a large part of the TCV outer divertor are reported in L-mode discharges with and without divertor baffles. This provides detailed insights into time averaged profiles, particle fluxes, and fluctuation behavior in different divertor regimes. The presence of the baffles is shown to substantially increase the divertor neutral pressure for a given upstream density and to facilitate the access to detachment, an effect that increases with plasma current. The detailed, 2D probe measurements allow for a divertor particle balance, including ion flux contributions from parallel flows and E × B drifts. The poloidal flux contribution from the latter is often comparable or even larger than the former, and the divertor parallel flow direction reverses in some conditions, pointing away from the target. In most conditions, the integrated particle flux at the outer target can be predominantly ascribed to ionization along the outer divertor leg, consistent with a closed-box approximation of the divertor. The exception is a strongly detached divertor, achieved here only with baffles, where the total poloidal ion flux even decreases towards the outer target, indicative of significant plasma recombination. The most striking observation from relative density fluctuation measurements along the outer divertor leg is the transition from poloidally uniform fluctuation levels in attached conditions to fluctuations strongly peaking near the X-point when approaching detachment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma contactor research, 1990

Emissive and Langmuir probes were used to measure plasma potential profiles, plasma densities, electron energy distributions, and plasma noise levels near a hollow cathode-based plasma contactor emitting electrons. The effects of electron emission current (100 to 1500 mA) and contactor flowrate (2 to 10 sccm (Xenon)) on these data are examined. Retarding potential analyzer (RPA) measurements showing that high energy ions generally stream from a contactor along with the electrons being emitted are also presented, and a mechanism by which this occurs is postulated. This mechanism, which involves a high rate of ionization induced between electrons and atoms flowing together from the hollow cathode orifice, results in a region of high positive space charge and high positive potential. Langmuir and RPA probe data suggests that both electrons and ions expand spherically from this potential hill region. In addition to experimental observations, a simple one-dimensional model which describes the electron emission process and predicts the phenomena just mentioned is presented and is shown to agree qualitatively with these observations. Experimental results of the first stage of bilateral cooperation with the Italian Institute of Interplanetary Space Physics (IFSI CNR) are presented. Sharp, well-defined double layers were observed downstream of a contactor collecting electrons from an ambient plasma created in the IFSI Facility. The voltage drop across these double layers was observed to increase with the current drawn from the ambient plasma. This observation, which was not as clear in previous IFSI tests conducted at higher neutral pressures, is in agreement with previous experimental observations made at both Colorado State University and NASA Lewis Research Center. Greater double layer voltage drops, multiple double layers, and higher noise levels in the region near the double layers were also observed when a magnetic field was imposed and oriented perpendicular to the line joining the contactor and simulator.

Williams, John D.↗

Interferometric phase velocity measurements in the auroral electrojet

A double-probe electric field detector and two spatially separated fixed-bias Langmuir probes were flown on a Taurus-Tomahawk sounding rocket launched from Poker Flat Research Range in March 1982. Interesting wave data have been obtained from about 10s of the downleg portion of the flight during which the rocket passed through the auroral electrojet. Here the electric field receiver and both density fluctuation (delta-n/n) receivers responded to a broad band of turbulence centered at 105 km-altitude and at frequencies generally below 4 kHz. Closer examination of the two delta-n/n turbulent waveforms reveals that they are correlated; from the phase difference between the two signals, the phase velocity of the waves in the rocket reference frame is inferred. The magnitude and direction of the observed phase velocity are consistent either with waves which travel at the ion sound speed or with waves which travel at the electron drift velocity. The observed phase velocity varies by about 50 percent over a 5 km altitude range, an effect which probably results from shear in the zonal neutral wind, although, unfortunately, no simultaneous neutral wind measurements exist to confirm this.

Labelle, J.↗

Performance of a quasi-steady, multi megawatt, coaxial plasma thruster

The Los Alamos National Laboratory Coaxial Thruster Experiment (CTX) has been upgraded to enable the quasisteady operation of magnetoplasmadynamic (MPD) type thrusters at power levels from 2 to 40 MW for 10 ms. Diagnostics include an eight position, three axis magnetic field probe to measure magnetic field fluctuations during the pulse; a triple Langmuir probe to measure ion density, electron temperature, and plasma potential; and a time-of-flight neutral particle spectrometer to measure specific impulse. Here we report on the experimental observations and associated analysis and interpretation of long-pulse, quasisteady, coaxial thruster performance in the CTX device.

Scheuer, Jay T.↗