Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIQUID DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Highly-Cyclable Room-Temperature Phosphorene Polymer Electrolyte Composites for Li Metal Batteries

Despite significant interest toward solid-state electrolytes owing to their superior safety in comparison to liquid-based electrolytes, sluggish ion diffusion and high interfacial resistance limit their application in durable and high-power density batteries. Here, a novel quasi-solid Li + ion conductive nanocomposite polymer electrolyte containing black phosphorous (BP) nanosheets is reported. The developed electrolyte is successfully cycled against Li metal (over 550 h cycling) at 1 mA cm -2 at room temperature. The cycling overpotential is dropped by 75% in comparison to BP-free polymer composite electrolyte indicating lower interfacial resistance at the electrode/electrolyte interfaces. Molecular dynamics simulations reveal that the coordination number of Li + ions around (trifluoromethanesulfonyl)imide (TFSI - ) pairs and ethylene-oxide chains decreases at the Li metal/electrolyte interface, which facilitates the Li + transport through the polymer host. Here, density functional theory calculations confirm that the adsorption of the LiTFSI molecules at the BP surface leads to the weakening of N and Li atomic bonding and enhances the dissociation of Li + ions. This work offers a new potential mechanism to tune the bulk and interfacial ionic conductivity of solid-state electrolytes that may lead to a new generation of lithium polymer batteries with high ionic conduction kinetics and stable long-life cycling.

2D materials↗

Oklo Sponsored Testing using PELICAN: System, Subchannel, and High-Fidelity Software Validation (Final CRADA Report)

Argonne National Laboratory (the Contractor), located in Lemont IL, and Oklo, Inc., (the Participant), headquartered in Santa Clara, CA, propose to enter into a Cooperative Research and Development Agreement (CRADA) to perform a gap analysis of thermal hydraulic data, perform prototypical fuel assembly pressure drop and cavitation model validation, generate the experimental data as well as the corresponding uncertainties for this matrix and, finally, develop the validation models with the Argonne system level code SAS4A/SASSYS-1, the Argonne subchannel analysis code DASSH, the Argonne high fidelity code Nek5000, and/or the Idaho National Laboratory code Pronghorn Subchannel. The work outlined below will significantly improve the experimental and validation database currently available for liquid metal fast reactors, thus making it a viable part of a comprehensive reactor design and licensing suite to be used by the participant.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Turbulent Liquid Spray Atomization Model for Diesel Engine Simulations (Final Technical Report)

This project addresses the systematic lack of predictive capabilities by spray models within engine CFD codes. We develop a new modeling approach to predict the breakup of diesel sprays based on recent literature showing that liquid turbulence plays a fundamental role in spray atomization. A new body of quantitative validation data is also developed as a critical element of the project, leveraging the joint capabilities of Georgia Tech’s high-pressure continuous-flow spray chamber and Argonne National Lab’s near-nozzle x-ray diagnostics at the Advanced Photon Source. This project contributes spatially-resolved measurements of drop size distribution within well-characterized diesel injectors, Spray A and D, from the Engine Combustion Network (ECN) to the engine combustion community for the first time. Utilizing this new body of measurements, we validate and demonstrate a new spray model for diesel sprays, termed the KH-Faeth model, that predicts global and local spray characteristic more accurately than the widely adopted and employed KH model. Predicted drop size distributions are seen to predict measured drops sizes both quantitatively and predictively, with accurate response in droplet size distributions over a wide range of ambient density, injection pressure, and injector nozzle size (Spray A and D) without model tuning. The KH-Faeth model can reduce error in the predicted centerline droplet size profile by up to 80% for ECN Spray D simulations when compared to use of the widely employed KH model.

33 ADVANCED PROPULSION SYSTEMS↗

pars2 (b1)

A laser disdrometer (LDIS) measures the drop size spectra and fall velocity of hydrometeors during precipitation events. The passage of hydrometeors through a horizontal area positioned between an eye-safe laser and an array detector results in blockage of the laser beam in proportion to the size of the drop or particle. In addition to drop/particle size and fall speed, precipitation type is classified. ARM also deploys video disdrometers (VDIS).

54 ENVIRONMENTAL SCIENCES↗

A remarkable CHF of 345W/cm 2 is achieved in a wicked-microchannel using HFE-7100

Boiling heat transfer of dielectric fluids is a promising cooling technique for thermal management of microelectronic systems. However, the critical heat flux achievable is generally low, because of the poor thermophysical properties of these fluids. Here, to address this dilemma, we propose a new cooling concept to substantially enhance global liquid supply during phase-change process using enhanced capillary-driven force. Additionally, dedicated vapor pathways are designed among a bank of micro-pillars to facilitate vapor removal. In this work, new wicks comprised of silicon micro-pinfin arrays are explored to significantly enhance the flow boiling heat transfer performance. To examine the functionalities of this wick, experiments on HFE-7100 were carried out with mass velocities varying from 247 to 3,465 kg/m 2 s. To explore the enhancement mechanisms and to analyze the capillary-assisted flow boiling process, visualization studies were conducted. The results indicate that sustainable evaporation induced by wick microstructures and efficient liquid supply are the enhancement mechanisms compared to parallel microchannels with solid walls. It is found that the overall heat transfer coefficient is substantially increased up to 75%. Remarkably, a high critical heat flux (CHF) of approximately 345 W/cm 2 is recorded at G = 3,465 kg/m 2 s at coolant inlet temperature of ~20 °C. Equally importantly, this noticeable enhancement of CHF value is associated with drastically decreased pressure drops compared to microchannels decorated with μ-pinfin fences.

36 MATERIALS SCIENCE↗

What Are the Similarities and Differences in Marine Boundary Layer Cloud and Drizzle Microphysical Properties During the ACE–ENA and MARCUS Field Campaigns?

This study compares macrophysical and microphysical properties of single-layered, liquid-dominant MBL clouds from the Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) (above 60°S) and the ARM East North Atlantic (ENA) site during the Aerosol and Cloud Experiments in Eastern North Atlantic (ACE-ENA) field campaign. A total of 1,136 (16.5% of clouds) and 6,034 5-min cloud samples are selected from MARCUS and ARM ENA in this study. MARCUS clouds have higher cloud-top heights, thicker cloud layers, larger liquid water path, and colder cloud temperatures than ENA. Thinner, warmer MBL clouds at ENA can contain higher layer-mean liquid water content due to higher cloud and ocean surface temperatures along with greater precipitable water vapor (PWV). MARCUS has a higher drizzle frequency rate (71.8%) than ENA (45.1%). Retrieved cloud and drizzle microphysical properties from each field campaign show key differences. MARCUS clouds feature smaller cloud droplets, whereas ENA clouds have larger cloud droplets, especially at the upper region of the cloud. From cloud top to cloud base, drizzle drop sizes increase while number concentrations decrease. Drizzle drop radius and number concentration decrease from cloud base to drizzle base due to net evaporation, and MARCUS' lower specific humidity leads to a higher drizzle base than ENA. In conclusion, the broader surface pressure and lower tropospheric stability (LTS) distributions during MARCUS have demonstrated that there are different synoptic patterns for selected cases during MARCUS with less PWV, while ENA is dominated by high pressure systems with nearly doubled PWV.

54 ENVIRONMENTAL SCIENCES↗

Studies on the Encapsulation of Brine Generated from a Process Using Selective Electrodialysis Reversal

This topical report summarizes the laboratory testing, geochemical modeling, and mineralogical testing conducted to examine the efficacy of wastewater encapsulation for the brine generated from the Saltworks Flex electrodialysis reversal technology. Within the laboratory testing, the short- and long-term physical properties of seven separate mix designs were examined along with the leaching of each mix design. Additionally, geochemical thermodynamic modeling was used along with mineralogical analyses to help gain a fundamental understanding of the chemistry involved in the encapsulation process. Encapsulation is a process that results in the immobilization of constituents of interest by creating an engineered material that contains the waste within its matrix, both physically and chemically, in such a manner that the receiving environment is protected from adverse effects. Within the context of this study, encapsulation mix designs involved mixing the Saltworks brine with fly ash and various additives, principally lime (calcium oxide) and cement, to form a paste that eventually sets and hardens into a monolith upon placement in a landfill. Moisture conditioning fly ash with wastewater sources for on-site landfill disposal is a process that is in use at some sites and has been presented as a viable option to dispose of liquid wastes. However, because chemical reactions that can lead to sequestration of constituents of interest are not optimized, leaching can occur. Therefore, in this study, mixes were created to mimic moisture conditioning, as well as engineered pastes of varying mix designs. The study found that engineered encapsulation mixes provide significant resistance to leaching compared to moisture conditioning alone. The best performing encapsulation mix used lime as the additive, which proved superior to the use of cement. After 90 days of curing, this encapsulated mix was 5.5 times stronger than the moisture conditioned mix. Additionally, this mix exhibited an approximate 2.5 order of magnitude drop in hydraulic conductivity compared to the moisture conditioned mix. When comparing leaching, nearly all the chloride was found to evolve from the moisture conditioned mix, whereas only 6.7% of the chlorine contained in the best performing encapsulated mix leached out. Mineralogical analysis via X-ray diffraction (XRD) showed a significant concentration of the chloride sequestering mineral, Friedel’s salt, in the best performing encapsulation mix, whereas none was observed in the moisture conditioned mix, pointing to it being the primary chemical mechanism for chloride retention, along with the physical impermeability of the material. With respect to the modeling study, the model was successful in predicting the presence of most mineral phases observed in the XRD analysis.

01 COAL, LIGNITE, AND PEAT↗

Interaction of magnetic fields with spinons in a fractionalized state

The 4d-electron trimer lattice Ba₄Nb₁₋ₓRu₃₊ₓO₁₂ exhibits either a quantum spin liquid (QSL) or a heavy-fermion strange metal (HFSM) phase, depending on Nb content. In the QSL state, itinerant spinons act as effective heat carriers, enhancing thermal conductivity. Strikingly, applying a magnetic field up to 14 T causes an abrupt, up-to-5000% increase in heat capacity below 150 mK, disrupting the linear temperature dependence typical of both phases. Meanwhile, AC susceptibility and electrical resistivity remain nearly unchanged, while thermal conductivity drops by up to 40% below 4 K. These results suggest spinons, despite being charge-neutral, are highly sensitive to magnetic fields at low temperatures. We propose that the magnetic field could induce Anderson localization of spinons, creating emergent non-magnetic two-level systems responsible for the Schottky-like anomaly in heat capacity. These findings point to a previously unexplored regime of spinon dynamics, potentially governed by field-induced localization and distinct from conventional magnetic or transport signatures.

Condensed-matter physics↗

Ion specific, thin film confinement effects on conductivity in polymerized ionic liquids.

Acrylate-based polymerized ionic liquids (PILs) with ammonium (Am) or imidazolium (Im) cations and tetrafluoroborate (BF4) or bis(trifluoromethanesulfonyl)imide (TFSI) anions were synthesized and spin coated onto gold interdigitated electrodes on silica to investigate nanoconfinement effects on ion transport. The film thickness ranged from 23 to 313 nm. A significant reduction of the in-plane conductivity was observed in some PIL thin films with thickness below 100 nm. Specifically, Am BF4 PIL showed the largest conductivity drop (ca. 50% difference between a 22 nm and a 261 nm film) while Im TFSI PIL showed almost no change under confinement. The difference in conductivity drop is discussed in terms of (i) differences in interfacial layer thickness by fitting a two-layer conductivity model and (ii) potential changes in glass transition temperature (T-g) under confinement, which were estimated using the Vogel-Fulcher-Tammann fits of bulk conductivities. Decreasing film thickness also caused the dielectric loss peaks to shift to lower frequency, indicating that the ion diffusion process slowed under confinement.

Zhao, Qiujie↗

Design of Muon Campus Full Flow Purifier for Varying Operational Conditions and Horizontal Shipping

The Muon Campus g-2 experiment requires stable helium supply at 5 K to the superconducting magnet. After a short period of operations, the pressure drop across the magnet’s flow supply valve increases due to impurities, resulting in reduced excess capacity concurrently with drop in refrigerator expander efficiency. This requires periodic powering down of the magnet to allow for helium valve “flush” to remove accumulated contamination at the valve as well as warming up the refrigerator expander above 80 K to release contamination. A “mobile” purifier is used for this periodic process but only at 10% of total refrigerator flow such that the purification process is extended. After long duration of running, this purification procedure is required almost every two weeks to restore proper liquid helium supply to the magnet. This shows requirement for full flow purifier which can purify impurities from entire Muon Campus refrigerator system and mitigate existing impurities issue and associated experiment downtime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-term stability-degradation analysis of DUNE SiPMs in Liquid Nitrogen

We developed a cryogenic photon readout system to monitor arrays of DUNE SiPMs operating at various over-voltages in liquid nitrogen (LN2) for over three months. Photoelectron signals were read out simultaneously via weak capacitive coupling to the micro-FEMB, a 32-channel charge sensitive readout board designed for 77 K to 300 K operation in liquid argon time projection chambers (LAr-TPCs). A waveform snippet acquisition scheme was implemented to capture waveform signals whenever they exceeded a predetermined trigger level; consequently, empty waveforms were discarded. Selected SiPM parameters were monitored to detect any deviations beyond statistical fluctuations. While some parameters exhibited ~1σ variations over the 3-month test period, there was no evidence of drift being enhanced when operating at 4 V or 5 V compared to a 3 V over-voltage. However, a discernible PDE drop was observed across all channels, which warrants further investigation. In addition, we demonstrated that our system can simultaneously read out single photons from a selected group of SiPMs at room temperature.

Tsang, Thomas [Brookhaven]↗

Nitrogen precooling heat exchanger replacement and control system upgrade in superfluid cryoplant at CMTF

Liquid nitrogen precooling is used in most cryoplants to achieve cooldown to 80 K temperature range. In one such system at Fermilab’s CMTF superfluid cryoplant, where the helium supply directly exchanges heat with liquid nitrogen, freezing of nitrogen occurred inside the heat exchanger due to heat exchanger flow imbalance during a cryoplant trip. Trapped vapor pockets of nitrogen within the frozen heat exchanger channels were formed while warming up the heat exchanger, creating high localized pressure and subsequent damage/rupture of the heat exchanger. Replacement of the heat exchanger was done, and modifications were made in the system to rectify future occurrences. The control system was updated to bypass the heat exchanger entirely if the incoming helium stream temperature drops below 76 K. This was done by repurposing two control valves as heat exchanger bypass valves that were previously used for a redundant 80 K adsorber in the coldbox. Additional modifications were made to further prevent return of large amount of cold helium gas from cold end during abrupt cryoplant shutdown. This modification has ensured high reliability of heat exchanger with prevention of freezing of nitrogen which can damage the heat exchanger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors↗

Experimental Investigation of Vapor Formation in Liquid CO2 Flow Through a Converging-Diverging Nozzle

Carbon dioxide is an attractive working fluid for many cycles, including for pumped thermal energy storage (PTES). A challenge with some proposed sCO2 PTES cycles is the operation of sCO2 machinery outside the typical bounds of experience, with local phase change from the liquid state being particularly unknown. Presently, there is insufficient data in the literature regarding multiphase CO2 to adequately design a multiphase-tolerant turbine, so generation of foundational data is required. This experimental study investigates the flow characteristics of sub-sonic liquid CO2 undergoing expansion and phase change in a converging-diverging nozzle. The nozzle is instrumented to measure static pressure, unsteady pressure, temperature, and density. The static pressure transducers are located at 27 axial locations to accurately characterize the pressure profile in the nozzle. High-accuracy RTDs are located at the entrance and exit of the nozzle, and three dynamic pressure transducers are strategically located to capture any unsteady phenomena. During testing, values of mass flow and nozzle inlet pressure are swept to vary the pressure drop and fluid properties. The measured total pressure drop in the nozzle is compared to a homogenous model and the Lockhart-Martinelli correlation method, with the latter predicting loss quite closely. The resulting data set is valuable for validating multiphase numerical models in a simple geometry before implementation of these models in turbomachinery design.

25 ENERGY STORAGE↗

Analysis and design of fast flow liquid Li divertor for fusion nuclear science facility (FNSF) using coupled plasma boundary and LM MHD/heat transfer codes *

The SOLPS-ITER code is utilized to analyze the boundary plasma associated with a fast-flow lithium (Li) divertor configuration in the fusion nuclear science facility (FNSF) tokamak and identify operational regimes with acceptable divertor and core conditions. Plasma transport from the SOLPS-ITER code has been coupled with a liquid metal (LM) MHD/heat transfer code to model a Li open-surface divertor design and assess its impact on the scrape-off-layer (SOL) and core plasma performance. Simulations with only Neon (Ne) impurity seeding have been conducted to evaluate its impact on meeting FNSF design demands for the divertor and upstream plasma parameters. Simulation results indicate that Ne seeding significantly mitigates divertor heat flux but potentially reduces both upstream electron and main ion density due to fuel dilution. The combined application of Ne seeding and deuterium (D 2 ) puffing is required to satisfy the FNSF design requirements on upstream density ($n^{OMP}_{e,sep}$~1× 10 20 m -3 ) and divertor energy flux ($q^{Odiv}_{\bot,max}$<10 MW m -2 ). D 2 puffing plays a role in counteracting upstream density drops and augmenting energy and momentum losses through atomic and molecular processes. The inlet Li flow velocity is systematically varied across a wide range to identify acceptable flows and corresponding LM surface temperatures. This comprehensive analysis identifies the acceptable Li flow parameters, LM surface temperature, and emitted Li fluxes necessary to meet the major design constraints. The emitted Li fluxes exhibit minimal impact on the main plasma at surface temperatures up to approximately ~525 °C, corresponding emitted Li fluxes of up to φ Li ~2X10 23 atoms s -1 . Uncertainties in the Li emission processes from the surface are also investigated, primarily influencing Li loss in the lower surface temperature range (<525 °C), with simulation results indicating a minor impact on the divertor and upstream plasma. Conversely, evaporation predominantly drives the Li loss processes at higher surface temperature ranges (>525 °C), contaminating both the divertor and upstream plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NH 4 OH Looping with Membrane CO 2 Absorber and Distributed Stripper for Enhanced Algae Growth

The University of Kentucky Center for Applied Energy (UK CAER) has devised a unique, integrated CO2 capture and utilization technology. CO2 from coal-fired power generation flue gas is first captured at half the operating cost of a typical aqueous CO2 capture system (CCS), distributed in an aqueous stream and then fixed by algae in bioreactors where the algae production is increased by 50% over that with a typical intermittent nutrient feeding system. Lower CCS operating cost is achieved by eliminating the flue gas pretreatment step for cooling and SO2 removal, eliminating steam extraction from the power generation steam cycle for solvent regeneration, and eliminating CO2 compression. Higher algae production is achieved by continuous, just-in-time nutrient feed to the bioreactors directly from a distributed solvent regenerator, which maintains the bioreactor pH for optimum growth. The process starts with a uniquely configured membrane absorber, where the flue gas is indirectly contacted with an ammonium hydroxide (NH4OH) solvent. Dissolved NH3 is attractive for both CO2 capture and as an algae nutrient. For CO2 capture it is inexpensive, has a low regeneration energy, is thermally- and oxidatively-stable and has a viscosity near that of water, which makes is easy to transport. Numerous studies have shown that the scrubbing capacity of NH3 is approximately 0.9-1.2 kg of CO2/kg of NH3, with a CO2 removal efficiency of ~99% and half the solvent regeneration energy than that of 30 wt% MEA[1, 2, 3]. NH3 is attractive as an algae nutrient due to its low cost. The rich NH4OH solvent is pumped to a set of distributed regenerators which are co-located with the algae bioreactors. Solvent pumping, transport and distribution reduces the balance of plant (BOP) cost compared to a typical aqueous CCS related to the flue gas duct and boost fan required to transport the flue gas. The energy required for the distributed solvent regeneration is supplied by solar-thermal panels eliminating the need for steam extraction from the power generation steam cycle. After solvent regeneration, the product stream contains both the CO2 captured from the flue gas and volatized NH3 from the solvent. This product stream is fed directly to the bioreactors, eliminating the need for compression of the CO2 stream. The relative amounts of CO2 and NH3 in the product stream are adjusted and controlled by a controlling the regeneration conditions (pressure and temperature). The continuous feed of the right ratio of nutrients overcomes the typical inhibition of algae growth resulting from frequent pH swings in the bioreactor due to unbalanced (intermittent) feeding systems for CO2 and N. Also, because the regenerators will operate at pressure and be located in close proximity to the bioreactors, there is no worry about pressure drop when sparging the gas into the algae. Sparging produces small bubbles which is beneficial for mass transfer efficiency. One known challenge when using an NH4OH solvent is high NH3 emission. Hydrophobic membranes are used for CO2 capture using an aqueous NH3 solution[4, 5] without the direct contact between flue gas and aqueous solution. Additionally, UK CAER CO2 capture and utilization process manages NH3 slip in three extra measures. First, NH3 slip is minimized by working with minimal species partial pressure, which is proportional to the concentration in the liquid. Hence, lowering the capture solvent concentration will lower the NH3 partial pressure. Second, UK CAER’s previous work has demonstrated that the addition of Zn2+ into NH3 solutions to chelate the NH3 can reduce NH3 volatility. Third, the configuration of the membrane CO2 absorber utilizes condensed water from the flue gas to continually wash the gas-side of the membrane to reduce fouling and recapture NH3 slip. Additional details about the UK CAER unique, integrated CO2 capture and utilization technology will be presented along with technology development plans. Diao, N., Q. Li, and Z. Fang. 2004. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences. 43: 1203-1211, He, Q., M. Chen, L. Meng, K. Liu, and W. Pan. 2004. Study on Carbon Dioxide Removal from Flue Gas by Absorption of Aqueous Ammonia. Western Kentucky University. Yeh, A.C., and H. Bai. 1999. Comparison of ammonia and monoethanolamine solvents to reduce CO2 greenhouse gas emissions. The Science of the Total Environment. 228: 121-133, Villeneuve, K., D. Roizard, J.C. Remigy, M. Iacono, and S. Rode. 2018. CO2 capture by aqueous ammonia with hollow fiber membrane contactors: Gas phase reactions and performance stability. Separation and Purification Technology, 199: 189-197, Toro Molina, C., and C. Bouallou. 2016. Carbon dioxide absorption by ammonia intensified with membrane contactors. Clean Techn Environ Policy 18, 2133–2146 (2016)

20 FOSSIL-FUELED POWER PLANTS↗

Next-Generation NGV Driver Information System

Measuring the amount of fuel contained in the tank of a Natural Gas Vehicle (NGV) is not as straightforward as it is for a liquid-fueled vehicle. The fuel in an NGV is a compressed gas at pressures up to 4200psig, and its pressure changes with temperature. The current state-of-the-art, which is used on most NGVs, is a simple pressure gauge as a rough guide for remaining fuel. This presents a high degree of error because pressure varies widely depending on temperature. Immediately following refueling, the temperature in the vehicle’s cylinders is often greater than 150°F. As the driver pulls out of the fueling station and begins consuming gas, the pressure drops at a very fast rate due to expansion cooling of the gas. This pressure drop appears to the driver to be a very rapid decrease in fuel level, reducing trust in the fuel level indication and leading to concern about the distance the vehicle can travel before refueling again, which is known as “range anxiety.”

03 NATURAL GAS↗

Transformation between elastic dipoles, quadrupoles, octupoles, and hexadecapoles driven by surfactant self-assembly in nematic emulsion

Emulsions comprising isotropic fluid drops within a nematic host are of interest for applications ranging from biodetection to smart windows, which rely on changes of molecular alignment structures around the drops in response to chemical, thermal, electric, and other stimuli. We show that absorption or desorption of trace amounts of common surfactants can drive continuous transformations of elastic multipoles induced by the droplets within the uniformly aligned nematic host. Out-of-equilibrium dynamics of director structures emerge from a controlled self-assembly or desorption of different surfactants at the drop-nematic interfaces, with ensuing forward and reverse transformations between elastic dipoles, quadrupoles, octupoles, and hexadecapoles. We characterize intertransformations of droplet-induced surface and bulk defects, probe elastic pair interactions, and discuss emergent prospects for fundamental science and applications of the reconfigurable nematic emulsions.

36 MATERIALS SCIENCE↗