Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADS - PLATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

High-Fidelity Large-Signal Order Reduction Approach for Composite Load Model

With the increasing penetration of electronic loads and distributed energy resources, conventional load models cannot capture their dynamics. Therefore, a new comprehensive composite load model is developed by Western Electricity Coordinating Council (WECC). However, this model is a complex high-order non-linear system with multi-time-scale property, which poses challenges on power system studies with heavy computational burden. In order to reduce the model complexity, the authors firstly develop a large-signal order reduction (LSOR) method using singular perturbation theory. In this method, the fast dynamics are integrated into the slow ones to preserve transient characteristics of the former. Then, accuracy assessment conditions are proposed and embedded into the LSOR to improve and guarantee the accuracy of reduced-order model. Finally, the reduced-order WECC composite load model is derived by using the proposed algorithm. Overall, simulation results show that the reduced-order large-signal model significantly alleviates the computational burden while maintaining similar dynamic responses as the original composite load model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A proposed criteria to identify wind turbine drivetrain bearing loads that induce roller slip based white-etching cracks

In this article, the type of roller slip behavior that may result in the formation of white-etching cracks (WECs) in wind turbine gearbox bearings is identified. A new hypothesis based on the inner raceway normal contact load magnitude at the time of roller slip is proposed as the probable cause of WECs. For this purpose, the maximum normal contact loads are identified when roller slip occurs in high-speed shaft bearings at different mean wind speeds. Subsequently, the annual probability of occurrence of the maximum normal loads are obtained. The probability of maximum load under slip exceeding a limit probability is hypothesized as a probable cause for WEC. In order to apply the proposed hypothesis, two different wind turbines high-speed shaft bearings are used: the cylindrical roller bearing of the General Electric 1.5 SLE turbine and the tapered roller bearing of Vestas V52 turbine. Both the chosen bearings are on the generator side of the high-speed shaft. For both turbines, measurement data together with analytical models are used for identifying the slip and the maximum normal contact loads. We propose forecasting the probability of exceedance of a threshold maximum normal contact load level during slip to identify the possibility for inducing WECs.

17 WIND ENERGY↗

Multi-stage load partitioning in additively manufactured Al6061+TiC nanocomposite characterized by in-situ neutron diffraction

Metal matrix composites (MMCs), combining metal matrix and ceramic particles, exhibit high mechanical strength and stiffness compared to conventional metallic materials. During fusion-based additive manufacturing (AM), MMCs undergo a rapid heating and cooling thermal history, which affects the interfacial bonding, thermal misfit stress and mechanical load transfer behavior between the metal matrix and particles, thus impacting the bulk mechanical performance. Here, we investigate the deformation dynamics and phase-specific load transfer in fusion-based AMed Al6061 +TiC MMCs through in-situ neutron diffraction. By calculating the phase-specific lattice strains, a multi-stage load transfer and deformation behavior during uniaxial compression is revealed: (1) elastic deformation in Stage I for both phases; (2) sudden stress rebalance between two phases in Stage II, evidenced by a sudden decrease in Al lattice strain and increase in TiC; (3) active load carrying by both phases in Stage III, with both phases experiencing an increase in lattice strains. Further, the deformation mechanism of each stage is deducted by correlating the evolutions of the interphase stresses and peaks’ broadening and intensity of the Al matrix. The local plastic deformation of the Al matrix near the phase interface is triggered and leads to stress rebalancing in Stage II. The global plastic deformation subsequently propagates throughout the Al matrix in Stage III, and the composite is further hardened through both dislocation multiplication and load transfer. The findings offer valuable insights into deformation and load-sharing behavior in AMed MMCs.

36 MATERIALS SCIENCE↗

Building thermal load prediction through shallow machine learning and deep learning

Building thermal load prediction informs the optimization of cooling plant and thermal energy storage. Physics-based prediction models of building thermal load are constrained by the model and input complexity. In this study, we developed 12 data-driven models (7 shallow learning, 2 deep learning, and 3 heuristic methods) to predict building thermal load and compared shallow machine learning and deep learning. The 12 prediction models were compared with the measured cooling demand. It was found XGBoost (Extreme Gradient Boost) and LSTM (Long Short Term Memory) provided the most accurate load prediction in the shallow and deep learning category, and both outperformed the best baseline model, which uses the previous day's data for prediction. Then, we discussed how the prediction horizon and input uncertainty would influence the load prediction accuracy. Major conclusions are twofold: first, LSTM performs well in short-term prediction (1 h ahead) but not in long term prediction (24 h ahead), because the sequential information becomes less relevant and accordingly not so useful when the prediction horizon is long. Second, the presence of weather forecast uncertainty deteriorates XGBoost's accuracy and favors LSTM, because the sequential information makes the model more robust to input uncertainty. Training the model with the uncertain rather than accurate weather data could enhance the model's robustness. Finally, our findings have two implications for practice. First, LSTM is recommended for short-term load prediction given that weather forecast uncertainty is unavoidable. Second, XGBoost is recommended for long term prediction, and the model should be trained with the presence of input uncertainty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric and sensitivity analysis of a PCM-integrated wall for optimal thermal load modulation in lightweight buildings

Load modulation in buildings is becoming increasingly important due to growing disparity in energy demand during peak and off-peak hours. Integrating phase change material (PCM) in building envelopes and using a controlled precooling strategy can provide substantial thermal load modulation; however, it may greatly increase the total energy use. Previous studies have employed PCM in building envelopes primarily for energy savings and, to some extent, peak load shedding and shifting. However, the load modulation capacity of a PCM-integrated envelope has not been well explored in the literature. In this study, we perform an extensive parametric and sensitivity analysis on PCM-integrated lightweight building walls and examine the combinatory effects of various PCM parameters on thermal load modulation and wall-related heat gains in buildings. Using numerical simulations, we investigate eight PCM parameters: PCM location in the wall, transition temperature, thickness, latent heat, transition range, density, specific heat, and thermal conductivity. Here, we evaluate their impact and relative importance to achieve maximum load modulation in buildings without compromising occupants’ thermal comfort or total energy use. The results show that the optimized PCM proposed in this study can completely invert the transient heat gain profile of the wall, providing up to 70% reduction of wall-related heat gain during peak hours without a major increase in the cumulative heat gain.

42 ENGINEERING↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Wind and structural loads data measured on parabolic trough solar collectors at an operational power plant

Abstract Wind loading is a primary contributor to structural design costs of concentrating solar-thermal power collectors, such as heliostats and parabolic troughs. These structures must resist the mechanical forces generated by turbulent wind, while the reflector surfaces must maintain optimal optical performance. Studying wind-driven loads at a full-scale, operational concentrating solar-thermal power plant provides insights into the wind impact on the solar collector field beyond the capabilities of wind tunnel tests or state-of-the-art simulations. We conducted comprehensive field measurements of the atmospheric turbulent wind conditions and the resulting structural wind loads on parabolic troughs at the Nevada Solar One plant over a two-year period. The measurement setup included meteorological masts and structural load sensors on four trough rows. Additionally, a lidar scanned the horizontal plane above the trough field. In this study, we describe the high-resolution dataset characterizing the complex flow field and resulting structural loads. This first-of-its-kind dataset will enhance the understanding of wind loading on collector structures and will help in designing the next-generation solar collectors and photovoltaic trackers.

14 SOLAR ENERGY↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

grid-following inverter↗

Small-Signal Stability Impacts of Load and Network Dynamics on Grid-Forming Inverters

This paper presents several stability analyses for grid-forming inverters and synchronous generators considering the dynamics of transmission lines and different load models. Load models are usually of secondary importance compared to generation source models, but as the results show, they play a crucial role in stability studies with the introduction of inverter-based resources. Given inverter control time scales, the implications of considering or neglecting electromagnetic transients of the network are very relevant in the stability assessments. In this paper, we perform eigenvalue analyses for inverter-based resources and synchronous machines connected to a load and explore the effects of multiples models under different network representations. We explore maximum loadability of inverter-based resources and synchronous machines, while analyzing the effects of load and network dynamic models on small-signal stability. The results show that the network representation plays a fundamental role in the stability of the system of different load models. The resulting stability regions are significantly different depending on the source and load model considered.

grid forming inverters↗

Power-to-Gas Systems for Active Load Management at EV Charging Sites with High DER Penetration

Intermittent renewable systems and increasing electric vehicle (EV) penetrations increase load intermittency—and will require expensive distribution system infrastructure upgrades. Power-to-gas (P2G) systems are highly controllable loads that can be modulated to regulate the net load behind the meter. In this work, we present an active load management approach using P2G systems to regulate the net load for an EV charging station with high penetrations of renewable generation. The system also validates the feasibility of the proposed approach using a 750-kW electrolyzer operated with the distribution system in a real-time power-hardware-in-the-loop test. Finally, we evaluate the impact of the size of the P2G system on its ability to regulate the net load.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Evaluation of Distributed Power Apportioning with Net Load Management Engine in Microgrids Using Power Hardware-in-the-Loop Simulation

This article presents the performance evaluation of ratio consensus-based distributed power apportioning engine along with centralized net load management (NLM) engine that ensures viable and stable operation of an islanded microgrid. Managing net load variability in a microgrid with high penetrations of uncertain renewable generation and ever-changing load demands is a crucial need in order to ensure viable and stable operation of the microgrid. Centralized “dispatch-rule”-based and/or multi-agent-based distributed control of distributed energy resources (DERs) in microgrid are well accepted for microgrid by adapting ANSI/ISA-95-based hierarchical control architecture. In the application where microgrid network has large geographical span with multiple DERs dispersed in the network, high penetration of uncertain renewable energy resources, and ever-changing load demands, a judicious selection of techniques/solutions for managing net-load resources for maintaining viability and stability is required. With this motivation, this article proposes a novel solution to mitigate the challenges by incorporating a mixed centralized NLM engine and distributed power apportioning control of DERs and loads. A power-hardware-in-the-loop (PHIL) -based experiment is conducted with the centralized NLM engine and the distributed power apportioning engine along with two commercial inverters. The experimental results validates the efficacy of the proposed method in ensuring viability and stability of a microgrid.

hardware-in-the-loop simulation↗

Deep Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-The-Meter Solar

The ever-growing integration of distributed energy resources (DERs), especially behind-the-meter (BTM) solar generations, poses imperative operational challenges to system operators such as regional transmission organizations (RTOs). It is important for RTOs to effectively and accurately extract actual load profiles at the transmission level for a single node with significant BTM solar injection. This paper first illustrates the necessity of disaggregating the daily actual load profile of a single node. Furthermore, by segmenting nodes with selected timeseries features, nodes with significant BTM solar generation are identified. Lastly, a bi-level framework is proposed, comprising reference node disaggregation and DeepFM nodal disaggregation, aimed at disaggregating the nodal load profiles from which system operators require more information. By adopting a hybrid Deep Factorization Machine (DeepFM) model, the model achieve accurate results by extracting both linear and nonlinear relations between nodes in the same region and the zonal load and nodal load profile. To overcome the lack of ground truth, this paper segments the load profile into daytime, nighttime, and zero-crossing points and utilizes the latter two for evaluation purposes. The proposed disaggregation procedure is validated using real world, minute-level, normalized, and anonymized nodal data in the PJM service territory.

42 ENGINEERING↗

Robust Deep Gaussian Process-Based Probabilistic Electrical Load Forecasting Against Anomalous Events

The abnormal events, such as the unprecedented COVID-19 pandemic, can significantly change the load behaviors, leading to huge challenges for traditional short-term forecasting methods. This article proposes a robust deep Gaussian processes (DGP)-based probabilistic load forecasting method using a limited number of data. Since the proposed method only requires a limited number of training samples for load forecasting, it allows us to deal with extreme scenarios that cause short-term load behavior changes. In particular, the load forecasting at the beginning of abnormal event is cast as a regression problem with limited training samples and solved by double stochastic variational inference DGP. The mobility data are also utilized to deal with the uncertainties and pattern changes and enhance the flexibility of the forecasting model. The proposed method can quantify the uncertainties of load forecasting outcomes, which would be essential under uncertain inputs. Extensive comparison results with other state-of-the-art point and probabilistic forecasting methods show that our proposed approach can achieve high forecasting accuracies with only a limited number of data while maintaining the excellent performance of capturing the forecasting uncertainties.

anomalous events↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wind Loading on CSP Collectors

The project significantly enhanced the community's understanding of the fundamental physics drivers underlying the wind-loading experienced by concentrating solar power (CSP) collector structures (i.e., parabolic troughs and heliostats) as well as their support structures. This project had two overarching objectives: (1) detailed measurements to characterize the prevailing wind conditions and resulting operational loads on collector structures, and (2) development and validation of a computationally efficient, high-fidelity modeling tool capable of predicting wind-loading in deep-array installations. Over three years, we conducted comprehensive at-scale field measurements of the atmospheric turbulent wind conditions, and the resulting wind loads on parabolic troughs and heliostats. Two at-scale measurement campaigns yielded first-of-its-kind, high-resolution, long-term datasets that are used to characterize the complex flow field and wind loading on parabolic-troughs and heliostats in operational power plants. The high-resolution measurements collected during these campaigns were used to validate the high-fidelity computational models developed at NREL. These open-source computationally efficient models were shown to be accurate in predicting wind-driven loads on collectors without the need for a large supercomputer.

14 SOLAR ENERGY↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding and lighting control for load shedding measures to reduce the HVAC and lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 3%-10% daily peak demand reduction performance for applicable buildings, and 0.97% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗