Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Bridging the gap between experiments and simulations using machine learning

The physics of inertial confinement fusion is rich and complex. Simulation codes that are used to design experiments are computationally expensive and lack the predictive capability required for extensive parameter exploration in search of a high-performing design for laser direct drive. In this work we use deep learning to build a fast emulator of experiments. To facilitate the development of the deep-learning model, an autoencoder is used to reduce the dimensionality of the input space. Two deep learning models are developed. One model is trained on a vast array of simulation data and is subsequently calibrated to expensive and limited experimental data using a technique known as “transfer learning.” The other model is trained on a statistical model and is subsequently calibrated using experimental data. A comparative study of the two predictive models is carried out. The models potentially reproduce key experimental observables with high accuracy and unprecedented inference times relative to those achieved with simulation codes. These models facilitate rapid exploration of a high dimensional input parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

Facile Measurement of the Rotation of a Single Optically Trapped Nanoparticle Using the Diagonal Ratio of a Quadrant Photodiode

Optical tweezers are a powerful tool for exploring physical properties of particles in various environments through analysis of their dynamics in a trapping potential. Analysis of the trapped particle's position is often done using interferometric back-focal-plane detection microscopy in which interference between the trapping laser and the light interacting with the trapped particle is projected on a quadrant photo-diode (QPD). The QPD measurements are almost universally the voltage ratios between the transverse components of the detector (left/right; up/down) that are calibrated to ascertain particle positions and orientations (i.e., rotation). In this paper, we demonstrate how measuring the diagonal ratio of the QPD allows tracking the spinning and orbital motion of optically trapped objects with enhanced sensitivity compared to the conventional transverse ratio and reveals additional information about particle dynamics. The diagonal ratio "balances" the signal from opposite sides of the QPD, allowing common mode noise reduction and increased measurement sensitivity of the rotating nanospheres at frequencies from below 200 Hz to above 15 kHz. We show that the variability in particle rotation rates is due to slight differences in the aspect ratio of the nanoparticles. We also measure in situ a gradual acceleration in the spinning frequency of trapped nanoparticles due to photothermal shedding of surface ligands and the resulting decrease of rotational friction in solution. The accelerating particles spin at rates exceeding 30 kHz and are eventually "optically printed" onto the glass coverslip on top of the liquid cell enclosure. The diagonal ratio is a simple, readily available, and powerful enabler for measuring rotational dynamics with a 5-fold sensitivity increase over conventional QPD measurements. This affords opportunities for controlling the orientational dynamics of trapped nanoparticles, which is crucial for various applications, including nanoscale mechanical motors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-of-flight methodologies with large-area diamond detectors for the effectively characterization of tens MeV protons

A novel detector based on a polycrystalline diamond sensor is here employed in an advanced time-of-flight scheme for the characterization of energetic ions accelerated during laser-matter interactions. The optimization of the detector and of the advanced TOF methodology allow to obtain signals characterized by high signal-to-noise ratio and high dynamic range even in the most challenging experimental environments, where the interaction of high-intensity laser pulses with matter leads to effective ion acceleration, but also to the generation of strong Electromagnetic Pulses (EMPs) with intensities up to the MV/m order. These are known to be a serious threat for the fielded diagnostic systems. Here we report on the measurement performed with the PW-class laser system Vega 3 at CLPU (~30 J energy, ~10 21 W/cm 2 intensity, ~30 fs pulses) irradiating solid targets, where both tens of MeV ions and intense EMP fields were generated. The data were analyzed to retrieve a calibrated proton spectrum and in particular we focus on the analysis of the most energetic portion (E > 5.8 MeV) of the spectrum showing a procedure to deal with the intrinsic lower sensitivity of the detector in the mentioned spectral-range.

47 OTHER INSTRUMENTATION↗

Oak Ridge National Laboratory Official TM Cover: Development and Qualification of Tungsten Reference Materials for LA-ICP-MS

Reference materials have been developed to provide areal density measurements of tungsten that is deposited on graphite when using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Several reference materials of varying areal densities have been produced using a magnetron sputtering, thin film deposition technique. With multiple reference materials that have varying areal densities, a calibration curve has been developed for translating the detector response of an ICP-MS into a quantitative measurement. These results provide the opportunity to make calibrated comparisons across graphite samples that were exposed to tungsten transport experiments for nuclear fusion research. In addition, these methods may be applied to provide individual areal density measurements for the five unique isotopes of tungsten. It is found that areal density measurements via LA-ICP-MS agree with characterization for the same samples when using the more traditional Rutherford backscattering ion beam technique. Qualification of these reference materials was completed using ion beam laboratories at the University of Tennessee, Knoxville and Massachusetts Institute of Technology, and Sandia National Laboratory.

36 MATERIALS SCIENCE↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of the thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery efficiency, and the acid dew point is a key parameter for this optimization. In this work, we analyze and discuss the theory of the sulfuric acid condensation process and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface, and the surface temperature of the window is slowly decreased until condensation is first observed, yielding an accurate measurement of the dew point. The basis of the instrument is that a collimated beam from a diode laser generates scattered light when encountering surface condensate, and a sophisticated array detector is used to sensitively monitor the light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, we propose a calibration system based on a liquid bubbler, which can generate a stable gas flow with known sulfuric acid dew point, to test the dew point meter. Test results show that the dew point meter can accurately measure the acid dew point over a wide range.

Cheng, Mao↗

Machine Learning–Augmented Laser-Induced Breakdown Spectroscopy for Spectral Discrimination of Iron Oxalates

Enhanced characterization and phase identification of post-PUREX Pu Oxalates (PuOXA) are pivotal for nonproliferation and pre-detonation nuclear forensics. Despite significant advances in the characterization of PuO 2 samples, little is known about the impact of both the chemical structure and oxidation states of PuOXA (i.e., Pu(III) and Pu(IV)) have on optical emission signatures. Here, we demonstrate the analytical capabilities of laser-induced breakdown spectroscopy (LIBS) applied to Fe(II) and Fe(III) oxalate samples as surrogates for PuOXA, highlighting the discriminating features in the LIBS emission spectra arising from differences in the oxidation states within mixed FeOXA samples. We report the enhancement of spectral feature selection using Principal Component Analysis (PCA), which enables the analytical superiority of machine learning algorithms such as Linear Discriminant Analysis (LDA), Quadratic Discriminant Analysis (QDA), Partial Least Squares Regression (PLSR), Support Vector Regression (SVR), and Random Forest Regression (RFR) over conventional univariate techniques for phase discrimination and chemometric analysis. Cluster analysis revealed how both matrix effects and laser ablation influence cluster separability by introducing spectral artifacts that misdirect the maximization of variance. PCA-selected emission lines were used in the regression models, demonstrating that both univariate and multivariate linear regression models (i.e., PLSR and SVR) can achieve acceptable performance, with machine learning models outperforming conventional calibration regressions. Furthermore, the application of non-linearly activated PCA-selected emission lines illustrates how simplifying the data while retaining captured variance enables the use of less complex and more computationally efficient models. Furthermore, this is particularly evident in the underperformance of RFR, which suffers from increased computational costs and overfitting owing to its high complexity.

Oxalates↗

Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.

47 OTHER INSTRUMENTATION↗

Deep spectral CNN for laser induced breakdown spectroscopy

This work proposes a spectral convolutional neural network (CNN) operating on laser induced breakdown spectroscopy (LIBS) signals to learn to (1) disentangle spectral signals from the sources of sensor uncertainty (i.e., pre-process) and (2) get qualitative and quantitative measures of chemical content of a sample given a spectral signal (i.e., calibrate). Once the spectral CNN is trained, it can accomplish either task through a single feed-forward pass, with real-time benefits and without any additional side information requirements including dark current, system response, temperature and detector-to-target range. Our experiments demonstrate that the proposed method outperforms the existing approaches used by the Mars Science Lab for pre-processing and calibration for remote sensing observations from the Mars rover, ‘Curiosity’.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution x-ray spectrometer for x-ray absorption fine structure spectroscopy

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX’s) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3–11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 μm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics’ OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

47 OTHER INSTRUMENTATION↗

A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

Rationale Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time elemental analysis of liquids for process monitoring using laser-induced breakdown spectroscopy with a liquid wheel sampling approach

This article presents an engineered sampling system that used a rotating wheel to form a thin liquid layer, permitting the use of laser-induced breakdown spectroscopy (LIBS) for in situ, real-time elemental impurity quantification during liquid processing. The sampling approach was demonstrated on eight elements from across the periodic table (Na, Al, K, Ca, Ti, Sr, Mo, and Yb). Univariate and multivariate calibrations were presented for each element. The average value for percent root mean square errors of cross-validation for the multivariate models was 3.64%, highlighting the method's strong prediction accuracy. Additionally, the limits of detection for each analyte were estimated from their univariate models: Na = 0.0532, Al = 18.5, K = 0.105, Ca = 0.273, Ti = 67.7, Sr = 0.640, Mo = 22.4, and Yb = 22.9 μg mL –1 . Finally, a test in which multivariate models were used to monitor a liquid system for 80 min was performed to investigate the real-time monitoring capabilities of this liquid LIBS sampling approach. Rigorous measurements were performed to effectively predict the absence and concentrations of multiple analytes as they were spiked and diluted. This demonstration showed the feasibility of using LIBS for real-time liquid quantification models with estimated precision ≤ 8.1%. Finally, the limitations of this approach and potential future improvements are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast External Quantum Efficiency Measurements of Photovoltaic Modules

The external quantum efficiency (EQE) or associated spectral response is widely used to evaluate the performance of photovoltaics, light emitting diodes, photodetectors, photodiodes, semiconductor lasers, laser-induced refrigeration of solids etc. For photovoltaic (PV) devices, The EQE is used to determine the spectral mismatch correction that is used to convert a performance measurement from a non-ideal simulator spectrum to a standard spectrum in PV device calibrations. Moreover, EQE can provide important insight into the physics of a PV device. For instance, the EQE shape can be used to infer mechanisms limiting the performance of the device. However, EQE measurements of full-size PV modules remain a challenge in the PV community due to rare availability of reliable module QE measurement tools worldwide and the size and complexity of module architecture that comprises several cells connected in strings (series or/and parallel). Here, we use a customized nondestructive tool made of high-power light emitting diodes to perform high-throughput EQE measurements on PV modules. Circuit simulations show that the measurement system can safely be used to measure both crystalline silicon and thin film-based PV modules with series connected cells without the risk of damage through reverse bias. In addition, EQE mapping combined with electroluminescence show a strong correlation and provide a way to determine both spatial non-uniformity of the spectral response and defects/degradation effects across the module.

PV module↗

Toward inverse backscatter absorption gas imaging: imaging a dry gas plume with ambient H 2 O absorption

This paper introduces inverse backscatter absorption gas imaging (iBAGI), a transparent gas imaging technique based on absorption spectroscopy of gases naturally present in ambient air being displaced by transparent gases. We demonstrate reconstruction of a 2-D image of a dry gas plume by measuring light of a raster-scanned diode laser tuned to an absorption line of atmospheric H 2 O. We quantify the performance depending on the distance to the backdrop and show that the key transmission metric is independent of absorption path length. We conclude with an outlook toward calibration-free, single-ended iBAGI using scattering from low-reflectivity backdrops.

Klug, Joseph C.↗

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

Absolute quantitation of propranolol from 200-μm regions of mouse brain and liver thin tissues using laser ablation-dropletProbe-mass spectrometry

Rationale: The ability to quantify drugs and metabolites in tissue with sub-mm resolution is a challenging but much needed capability in pharmaceutical research. To fill this void, a novel surface sampling approach combining laser ablation with the commercial dropletProbe automated liquid surface sampling system (LA-dropletProbe) was developed and presented here.Methods: Parylene C-coated 200 × 200 μm tissue regions of mouse brain and kidney thin tissue sections were analyzed for propranolol by laser ablation of tissue directly into a preformed liquid junction. Propranolol was detected by high performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry. Quantitation was achieved via application of a stable isotope-labeled internal standard and an external calibration curve.Results: Absolute concentration of propranolol determined from 200 × 200 µm tissue regions were compared to propranolol concentrations obtained from 2.3-mm-diameter tissue punches of adjacent, non-coated sections using standard bulk tissue extraction protocols followed by regular HPLC-MS/MS analysis. Average concentration of propranolol in both organs determined by the two employed methods agreed within ±12%. Furthermore, the relative abundance of phase II hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous results.Conclusions: This work illustrates that depositing a thin parylene C layer onto thin tissue prior to analysis, which seals the surface and prevents direct liquid extraction of the drug from the tissue, coupled to the novel LA-dropletProbe surface sampling system is a viable approach for sub-mm resolution quantitative drug distribution analysis.

59 BASIC BIOLOGICAL SCIENCES↗

DayCent data and results for "Robust paths to net greenhouse gas mitigation and negative emissions via advanced biofuels"

DayCent data and results for:J. L. Field, T. L. Richard, E. A. Smithwick, H. Cai, M. S. Laser, D. S. LeBauer, S. P. Long, K. Paustian, Z. Qin, J. J. Sheehan, P. Smith, M. Q. Wang, L. R. Lynd, Robust paths to net greenhouse gas mitigation and negative emissions via advanced biofuels. Proceedings of the National Academy of Sciences (2020). https://doi.org/10.1073/pnas.1920877117 This zip file contains a UNIX-format DayCent model executable, input files, automation code, and associated directory structure necessary to re-produce the DayCent analysis underlying the manuscript. The main script 'autodaycent.py' (written for Python 2.7) opens an interactive command line routine that facilitates:* Calibrating the DayCent pine growth model.* Initializing DayCent for a set of case studies sites.* Executing an ensemble of model runs representing case study site reforestation, grassland restoration, or conversion to switchgrass cultivation. * Results analysis & generation of manuscript Fig. 3. Note that the interactive analysis code requires that all input files to be contained in the directory structure as uploaded, without modification. Executable versions of the DayCent model (https://www.nrel.colostate.edu/projects/daycent/) compatible with other operating systems are available upon request.Please send questions/comments to John.L.Field@gmail.com

Agro-ecosystem function and prediction↗

Combining In-situ Diagnostics and Data Analytics for Discovery of Process-Structure-Property Relationships in AM parts – A Step Toward Digital Twins

In-situ additive manufacturing (AM) diagnostic tools (e.g., optical/infrared imaging, acoustic, etc.) already exist to correlate process anomalies to printed part defects. This current work aimed to augment existing capabilities by: 1) Incorporating in-situ imaging w/ machine learning (ML) image processing software (ORNL- developed "Peregrine") for AM process anomaly detection 2) Synchronizing multiple in-situ sensors for simultaneous analysis of AM build events 3) Correlating in-situ AM process data, generated part defects and part mechanical properties The key R&D question investigated was to determine if these new combined hardware/software tools could be used to successfully quantify defect distributions for parts build via SNL laser powder bed fusion (LPBF) machines, aiming to better understand data-driven process-structure-property- performance relationships. High resolution optical cameras and acoustic microphones were successfully integrated in two LPBF machines and linked to the Peregrine ML software. The software was successfully calibrated on both machines and used to image hundreds of layers of multiple builds to train the ML software in identifying printed part vs powder. The software's validation accuracy to identify this aspect increased from 56% to 98.8% over three builds. Lighting conditions inside the chamber were found to significantly impact ML algorithm predictions from in-situ sensors, so these were tailored to each machine's internal framework. Finally, 3D part reconstructions were successfully generated for a build from the compressed stack of layer-wise images. Resolution differences nearest and furthest from the optical camera were discussed. Future work aims to improve optical resolution, increase process anomalies identified, and integrate more sensor modalities.

36 MATERIALS SCIENCE↗