Variability in Mt. Sharp Group Bedrock as Seen By ChemCam Passive and Active Spectra

The Curiosity rover landed in Gale crater in August 2012 and has since been travelling up the central sedimentary mound known as Mt. Sharp. The ChemCam instrument on Curiosity was designed primarily for the use of Laser Induced Breakdown Spectroscopy (LIBS), where a laser ablates a small amount of material from the target and the spectrum of the resulting plasma yields elemental abundance data. ChemCam’s three spectrometers range from 240-905 nm and can also take passive spectra (without the use of the laser). The spectral range ChemCam passive spectra observe is sensitive to charge-transfer and crystal field absorptions related to iron-bearing minerals. In the first 2934 sols of Curiosity’s mission, 9,400 passive spectra were taken of bedrock targets in Mt. Sharp’s Murray and Carolyn Shoemaker formations. We examine these spectra using spectral slope/ratio and band depth calculations as well as Principal Component Analysis (PCA). For the first time, paired passive spectra and LIBS elemental abundances are compared on a large scale. Finally, CheMin data are compared to ChemCam passive observations to understand sources of spectral variability.

H T Manelski↗

Video-Camera-Based Position-Measuring System

A prototype optoelectronic system measures the three-dimensional relative coordinates of objects of interest or of targets affixed to objects of interest in a workspace. The system includes a charge-coupled-device video camera mounted in a known position and orientation in the workspace, a frame grabber, and a personal computer running image-data-processing software. Relative to conventional optical surveying equipment, this system can be built and operated at much lower cost; however, it is less accurate. It is also much easier to operate than are conventional instrumentation systems. In addition, there is no need to establish a coordinate system through cooperative action by a team of surveyors. The system operates in real time at around 30 frames per second (limited mostly by the frame rate of the camera). It continuously tracks targets as long as they remain in the field of the camera. In this respect, it emulates more expensive, elaborate laser tracking equipment that costs of the order of 100 times as much. Unlike laser tracking equipment, this system does not pose a hazard of laser exposure. Images acquired by the camera are digitized and processed to extract all valid targets in the field of view. The three-dimensional coordinates (x, y, and z) of each target are computed from the pixel coordinates of the targets in the images to accuracy of the order of millimeters over distances of the orders of meters. The system was originally intended specifically for real-time position measurement of payload transfers from payload canisters into the payload bay of the Space Shuttle Orbiters (see Figure 1). The system may be easily adapted to other applications that involve similar coordinate-measuring requirements. Examples of such applications include manufacturing, construction, preliminary approximate land surveying, and aerial surveying. For some applications with rectangular symmetry, it is feasible and desirable to attach a target composed of black and white squares to an object of interest (see Figure 2). For other situations, where circular symmetry is more desirable, circular targets also can be created. Such a target can readily be generated and modified by use of commercially available software and printed by use of a standard office printer. All three relative coordinates (x, y, and z) of each target can be determined by processing the video image of the target. Because of the unique design of corresponding image-processing filters and targets, the vision-based position- measurement system is extremely robust and tolerant of widely varying fields of view, lighting conditions, and varying background imagery.

Lane, John↗

The construction of a highly transportable laser ranging station

The technology of the transportable Laser Ranging Station (TLRS) used in crustal dynamics studies was examined. The TLRS used a single photoelectron beam of limited energy density returned from the Laser Geodynamic Satellite (LAGEOS). Calibration was accomplished by the diversion of a small portion of the outgoing beam attenuated to the same level as the satellite return. Timing for the system was based on a self calibrating Ortec TD811, 100 picosec time interval device. The system was contained in a modified, single chassis recreational vehicle that allowed rapid deployment. The TLRS system was only airmobile on the largest transport aircraft. A 30 cm simple plano/concave transfer lens telescope aided in beam direction. The TLRS system fulfills the need for an accurate method of obtaining range measurements to the LAGEOS satellite incorporated in a mobile, air transportable, and economical configuration.

Source record↗

Communications, Signal Processing, and Telemetering Research Program Review

A Communications, Signal Processing, and Telemetering Research Program Review was held on February 23, 1999. Research conducted under the grant was presented and reviewed, for progress, and for possible technology transfers. The research reviewed was in the following areas: (1) Bandwidth-efficient Modulation and nonlinear equalization; (2) Investigation of an architecture for parallel signal processing applicable to communications problems; (3)Coded partial response over satellites; (4) synchronization at Low SNR; (5) Serial concatenated convolutional codes and some implementation issues on high rate turbo codes; (6) Flight experiments; (7) Real time doppler tracking; (8) Space protocol testing; (9) Lightweight optical communications without carrying a laser in space. The presentations are given by the graduate students who performed the research.

Source record↗

Advancements of On-Line Monitoring and Real-Time Characterization of Actual Low-Level Hanford Tank-Waste Samples

Waste and process stream characterization is essential to the safe, efficient, and cost-effective processing of Hanford Site materials. The demand for materials characterization including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward Hanford waste treatment and immobilization. Our past work has applied Raman on-line monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105 and has demonstrated the quantitative measurement of nine analytes within this waste. To demonstrate broader applicability, this method has now been expanded to waste from two additional Hanford tanks, AW-102 and AP-107, and the offgas condensate from lab-scale melter runs of actual-tank waste feeds. To enhance the performance of the Raman method, instruments with various excitation wavelengths were compared, since it is known that the Raman response is enhanced by shorter wavelength excitation. The laser excitations for the three systems tested were 404 nm, 532 nm, and 671 nm. In addition to laser wavelength selection, the laser power, measurement integration times, and signal averaging techniques were also investigated to determine their effect on detection limits for oxy-anion analytes within tank wastes. These advancements in Raman capability are compared with past standards and will be presented.

Bryan, Samuel A.↗

Direct observation of charge separation in an organic light harvesting system by femtosecond time-resolved XPS

The ultrafast dynamics of photon-to-charge conversion in an organic light-harvesting system is studied by femtosecond time-resolved X-ray photoemission spectroscopy (TR-XPS) at the free-electron laser FLASH. This novel experimental technique provides site-specific information about charge separation and enables the monitoring of free charge carrier generation dynamics on their natural timescale, here applied to the model donor-acceptor system CuPc:C 60 . A previously unobserved channel for exciton dissociation into mobile charge carriers is identified, providing the first direct, real-time characterization of the timescale and efficiency of charge generation from low-energy charge-transfer states in an organic heterojunction. The findings give strong support to the emerging realization that charge separation even from energetically disfavored excitonic states is contributing significantly, indicating new options for light harvesting in organic heterojunctions.

14 SOLAR ENERGY↗

A high speed buffer for LV data acquisition

The laser velocimeter (autocovariance) buffer interface is a data acquisition subsystem designed specifically for the acquisition of data from a laser velocimeter. The subsystem acquires data from up to six laser velocimeter components in parallel, measures the times between successive data points for each of the components, establishes and maintains a coincident condition between any two or three components, and acquires data from other instrumentation systems simultaneously with the laser velocimeter data points. The subsystem is designed to control the entire data acquisition process based on initial setup parameters obtained from a host computer and to be independent of the computer during the acquisition. On completion of the acquisition cycle, the interface transfers the contents of its memory to the host under direction of the host via a single 16-bit parallel DMA channel.

Cavone, Angelo A.↗

Petabyte mass memory system using the Newell Opticel(TM)

A random access system is proposed for digital storage and retrieval of up to a Petabyte of user data. The system is comprised of stacked memory modules using laser heads writing to an optical medium, in a new shirt-pocket-sized optical storage device called the Opticel. The Opticel described is a completely sealed 'black box' in which an optical medium is accelerated and driven at very high rates to accommodate the desired transfer rates, yet in such a manner that wear is virtually eliminated. It essentially emulates a disk, but with storage area up to several orders of magnitude higher. Access time to the first bit can range from a few milliseconds to a fraction of a second, with time to the last bit within a fraction of a second to a few seconds. The actual times are dependent on the capacity of each Opticel, which ranges from 72 Gigabytes to 1.25 Terabytes. Data transfer rate is limited strictly by the head and electronics, and is 15 Megabits per second in the first version. Independent parallel write/read access to each Opticel is provided using dedicated drives and heads. A Petabyte based on the present Opticel and drive design would occupy 120 cubic feet on a footprint of 45 square feet; with further development, it could occupy as little as 9 cubic feet.

Newell, Chester W.↗

Enhanced Boiling on Micro-Configured Composite Surfaces Under Microgravity Conditions

Two experimental setups: High Heat Flux Pool Boiling Setup and Optical system of Measuring Contact Angle and Spreading Parameters were established and a series of experiments was conducted. The experimental work on the nucleate boiling performance of both Freon-113 and water on the composite surfaces has been finished and the results show that the composite surface with 25% volume fraction of graphite fibers in the copper matrix has the best enhancing performance. Stronger enhancement was obtained for water compared to Freon-113. The wall superheat initiating boiling was reduced 40% and 35% and the heat flux of the nucleate boiling was augmented up to ten times and 6.7 times, respectively. A bubble departure model has been presented to explain the enhancement mechanism of the boiling heat transfer on the composite surfaces. A powerful optical method to measure contact angle and spreading parameters of liquids on solid surfaces, including both transparent and non-transparent substrates, has been developed and successfully used in the measurements for various liquid-solid systems. The experimental work on identification of profiles near three-phase line by laser shadowgraphy method has been finished and the characteristics of the three-phase line for different liquid-solid systems were unveiled, which is very important to understand the mechanism of boiling under microgravity conditions. The four basic patterns of sessile profile were discovered through caustics and caustic-diffraction analysis by applying wave theory in shadowgraphy technology, which contributes to clearly explain the different characteristics of wetting and spreading of various liquids on a solid surface, and therefore to further understand the bubble departure mechanisms. A new working pattern of heat pipes using working fluids with positive surface-tension gradient against temperature was discovered and analyzed, and then the new heat pipe systems using this kind of working fluids have been presented. Two patent devices, i.e. Shadowgraphic Method to Measure Properties of Sessile Drops and Heat Pipe Systems Using New Working Fluids, have been developed; the former has been approved by The United States Patent & Trademark Office and the latter is being examined.

Source record↗

Imaging Wavepackets in Real-Space & Disentangling Ultrafast Solvation Dynamics with High-Energy Ultrafast X-ray Scattering

The microscopic information of solute and solute-solvent motions can be measured using ultrafast diffuse x-ray scattering, and compared to molecular dynamics simulations, as demonstrated in studies of solvated molecular systems done in X-ray free-electron lasers. However, for the typical photon energies used in these experiments, the photon momentum transfer range was limited to lower Q values where the signals arising from different parts of the studied system overlap significantly. Recently, this limitation was greatly alleviated by extending the photon energy at the Linac Coherent Light-Source (LCLS), significantly increasing the accessible momentum transfer range. This improvement is transformative for ultrafast diffuse x-ray scattering measurements, enabling for the first time to disentangle the solute scattering difference signal, that persists to higher Q values, from the bulk solvent and solute-solvent cross-terms difference signals. In addition, it enhances the prediction ability of modeling and simulation methods such as the hybrid QM/MM approach. The extended Q range also opens the way to resolve in real-space details regarding coherent wavepackets motions beyond their center-of-mass positions. Here, we present the first results on high-energy (18keV) diffuse x-ray scattering in solution, demonstrating high fidelity time-resolved scattering and analysis of the photoexcited model photocatalysts PtPOP ([Pt2(POP)4]4-), and IrDimen ([Ir2(dimen)4]2+) in several solvents. These complexes provide ideal systems for demonstrating the ability of high-Q ultrafast scattering and QM/MM simulations to decompose ultrafast solvation dynamics into specific changes in the solute-solvent pair distribution function with a particular focus on how electronically excited states change the interaction between the solvent and photo-catalytically active metal sites. We introduce an approach to further utilize the high-energy capability and demonstrate a single-shot ultra-wide-angle X-ray Scattering modality using two perpendicular detectors, spanning a scattering angle range of more than 100 degrees, allowing to extend the accessible momentum transfer range up to Q~14 Å-1. We develop a model-free method to invert the x-ray scattering signals and enable the recovery of multiple pair-density motions that happen simultaneously, allowing us to directly measure in real-space nuclear wavepacket motions. . [1] Natan, Adi. "Real-Space Inversion and Super-Resolution of Ultrafast X-ray Scattering using Natural Scattering Kernels." arXiv preprint arXiv:2107.05576 (2021)

Natan, Adi↗

Design Overview of a High-Pressure Helium Flow Visualization Apparatus for Blanket Cooling Studies

Cooling of the fusion blanket first wall remains a significant challenge given the adverse conditions of heat and particle flux encountered near the plasma. Helium emerges as an attractive cooling candidate because of its chemical and neutronic inertness and separability from hydrogenic species (e.g. tritium). Because of the low thermal mass of helium, optimization of these coolant channels is warranted to provide high heat transfer performance at low pumping costs. Increasingly, computational fluid dynamics (CFD) simulations are employed to model and optimize these flow channels, and accompanying experimental data are needed to validate the predictions of these models. To provide the aforementioned experimental data, a high-pressure helium flow visualization upgrade has been designed for the Helium Flow Loop Experiment facility. This apparatus was built to American Society of Mechanical Engineers boiler and pressure vessel standards to withstand operating pressure of 4 MPa and mated to high-pressure glass windows. Seedless flow visualization is performed via high-speed background oriented schlieren (BOS), with image correlation used for time-resolved two-dimensional velocimetry at frequencies in excess of 60 kHz. Rectangular flow channel test articles are additively manufactured via laser powder bed fusion and installed into this visualization apparatus, with one-sided heating supplied by resistive heaters. In conclusion, the chosen test geometries were informed by prior CFD simulations, and the helium flow structures observed via BOS (detachment, recirculation, etc.) will be used for the validation of these accompanying models, in support of the design and optimization of blanket cooling channel configurations.

Helium flow↗

Time-resolved double-probe study in a He-Hg afterglow plasma

An experimental double-probe technique is described which allows the He(+) ion density to be measured directly as a function of time in the afterglow of a helium-metal-vapor discharge. As an application example, two CW laser transitions of the He-Hg(+) laser at 6150 and 7944 A are considered which both arise from excited 7p (2) P terms of Hg II. The time-resolved double-probe technique is used to measure the destruction rate of the He(+) ion density, which is then compared with the spontaneous-emission decay rate for 7p (2) P terms of Hg II. The results obtained show unambiguously and directly that the dominant excitation process for the two transitions considered is a charge-transfer collisional reaction of the form He(+) plus Hg yields He plus metastable Hg(+) plus the energy defect for this reaction. It is noted that the time-resolved double-probe technique may provide a simple method for measuring ion mobilities in a multi-ion plasma.

Shay, T.↗

Large Momentum Transfer Clock Atom Interferometry on the 689 nm Intercombination Line of Strontium

We report the first realization of large momentum transfer (LMT) clock atom interferometry. Using single-photon interactions on the strontium $^1S_{0^–}^3P_1$ transition, we demonstrate Mach-Zehnder interferometers with state-of-the-art momentum separation of up to 141 $\textit{ℏk}$ and gradiometers of up to 81 $\textit{ℏk}$. Furthermore, we circumvent excited state decay limitations and extend the gradiometer duration to 50 times the excited state lifetime. Because of the broad velocity acceptance of the interferometry pulses, all experiments are performed with laser-cooled atoms at a temperature of 3 μK. This work has applications in high-precision inertial sensing and paves the way for LMT-enhanced clock atom interferometry on even narrower transitions, a key ingredient in proposals for gravitational wave detection and dark matter searches.

74 ATOMIC AND MOLECULAR PHYSICS↗

Detailed investigation of a vaporising fuel spray. Part 1: Experimental investigation of time averaged spray

A laser tomographic light scattering technique provides rapid and accurate high resolution measurements of droplet sizes, concentrations, and vaporization. Measurements using a computer interfaced thermocouple are presented and it is found that the potential exists for separating gas and liquid temperature measurements and diagnosing local spray density by in situ analysis of the response characteristics of the thermocouple. The thermocouple technique provides a convenient means for measuring mean gas velocity in both hot and cold two phase flows. The experimental spray is axisymmetric and has carefully controlled initial and boundary conditions. The flow is designed to give relatively insignificant transfer of momentum and mass from spray to air flow. The effects of (1) size-dependent droplet dispersion by the turbulence, (2) the initial spatial segregation of droplet sizes during atomization, and (3) the interaction between droplets and coherent large eddies are diagnosed.

Yule, A. J.↗

Infrared spectroscopy of RG–Co + (H 2 O) complexes (RG = Ar, Ne, He): The role of rare gas “tag” atoms

RG n –Co + (H 2 O) cation complexes (RG = Ar, Ne, He) are generated in a supersonic expansion by pulsed laser vaporization. Here, complexes are mass-selected using a time-of-flight spectrometer and studied with infrared laser photodissociation spectroscopy, measuring the respective mass channels corresponding to the elimination of the rare gas “tag” atom. Spectral patterns and theory indicate that the structures of the ions with a single rare gas atom have this bound to the cobalt cation opposite the water moiety in a near-C 2v arrangement. The O–H stretch vibrations of the complex are shifted compared to those of water because of the metal cation charge-transfer interaction; these frequencies also vary systematically with the rare gas atom attached. The efficiencies of photodissociation also vary with the rare gas atoms because of their widely different binding energies to the cobalt cation. The spectrum of the argon complex could only be measured when at least three argon atoms were attached. In the case of the helium complex, the low binding energy allows the spectra to be measured for the low-frequency H–O–H scissors bending mode and for the O–D stretches of the deuterated analog. The partially resolved rotational structure for the antisymmetric O–H and O–D stretches reveals the temperature of these complexes (6 K) and establishes the electronic ground state. The helium complex has the same 3 B 1 ground state as the tag-free complex studied previously by Metz and co-workers (2013), but the A rotational constant is contaminated by vibrational averaging from the bending motion of the helium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of spectroscopic properties of Tm and Ho in YAG and YLF crystals

The paper compares the cross-relaxation, energy transfer and loss processes in Tm- and Ho-doped YAG and YLF as a function of temperature, Tm concentration, and excitation power. Significant differences in the behavior of Tm and Tm,Ho in YAG and YLF crystals were found. The cross-relaxation rates of Tm(6 pct) are faster in YLF (about 5 microsec) than YAG (about 10 microsec). The energy transfer rates between Tm and Ho are faster in YLF than YAG. The time it takes for the maximum intensity of 1.7-micron emission to drop 10 percent is 25 microsec for YLF:Tm(6 pct),Ho(0.6 pct) and 65 microsec YAG:Tm(6 pct),Ho(0.5 pct). The losses occurring with increasing pump power for 2.1-micron emission of the above samples are 30 percent less in YLF than YAG. These qualitative differences point to YLF as a valuable 2-micron laser host material.

Armagan, G.↗

Sensing the gas metal arc welding process

Control of gas metal arc welding (GMAW) requires real-time sensing of the process. Three sensing techniques for GMAW are being developed at the Idaho National Engineering Laboratory (INEL). These are (1) noncontacting ultrasonic sensing using a laser/EMAT (electromagnetic acoustic transducer) to detect defects in the solidified weld on a pass-by-pass basis, (2) integrated optical sensing using a CCD camera and a laser stripe to obtain cooling rate and weld bead geometry information, and (3) monitoring fluctuations in digitized welding voltage data to detect the mode of metal droplet transfer and assure that the desired mass input is achieved.

Carlson, N. M.↗

Capabilities Enhanced for Researching the Reduction of Emissions in Future Aircraft

Aircraft future aircraft jet engines will run at higher pressures to obtain greater fuel efficiency and performance. This will require new combustor designs to keep the nitrogen oxide and carbon monoxide emissions at environmentally acceptable levels. The actual pressures and temperatures found in gas turbine combustors must be duplicated in a laboratory to verify the emissions characteristics of gas turbine engines. Recognizing this, the U.S. aircraft gas turbine industry identified a need for a national facility that could duplicate the severe inlet conditions of future combustors. Because of our expertise in combustion emissions reduction research and in the design and operation of high-pressure test facilities, the NASA Lewis Research Center was seen as the natural location for such a facility. As a national laboratory, Lewis could provide these facilities to all U.S. gas turbine engine manufacturers while protecting their proprietary interests. Called the Advanced Subsonic Combustion Rig, the facility will provide up to 60-atm pressures at inlet temperatures up to 1300 F and air flow rates up to 38 lb/sec. Furthermore, it will offer state-of-the-art diagnostic methods for characterizing advanced combustor concepts. Aeronautical combustion research at Lewis provided several significant accomplishments recently in support of both the High Speed Research (HSR) and Advanced Subsonic Technology (AST) programs. For example, in the High Speed Research Program, NO_x reductions of up to 90 percent were achieved in prototype combustor hardware. Advanced computational analysis, gas sampling, and laser diagnostic techniques were critical to this success. Working closely with the gas turbine industry, we have successfully transferred this low-emissions combustor technology into engine prototype hardware. This hardware is now being tested at the engine manufacturers facilities. Complementary tests in Lewis currently available 30-atm test facilities are also underway, taking advantage of Lewis unique diagnostic capabilities. By utilizing test facilities belonging to both NASA and its industry partners, we have tested multiple combustor concepts in a shorter period of time.

Source record↗