Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laue diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Highly asymmetric Laue focusing monochromator

By using two highly asymmetric Laue crystals in a dispersive arrangement with a circular profile (Oe 8 mm) we have created a sagittaly focusing Laue system for the first time. The crystallographic planes (111) of the two Si crystals formed an angle of 7.95 deg. with the entrance surface. The crystals dimensions were 40 mmx20 mm and the diffracting surface was a 0.5 mm thick neck between the two circular profiles. The 15.35 keV diffracted beam formed an angle of 0.55 deg. with the exit surface. The calculated focusing distance of the Laue-Laue focusing system was 14 m.

43 PARTICLE ACCELERATORS↗

Three-energy focusing Laue monochromator for the diamond light source x-ray pair distribution function beamline I15-1

The I15-1 beamline, the new side station to I15 at the Diamond Light Source, will be dedicated to the collection of atomic pair distribution function data. A Laue monochromator will be used consisting of three silicon crystals diffracting X-rays at a common Bragg angle of 2.83°. The crystals use the (1 1 1), (2 2 0), and (3 1 1) planes to select 40, 65, and 76 keV X-rays, respectively, and will be bent meridionally to horizontally focus the selected X-rays onto the sample. All crystals will be cut to the same optimized asymmetry angle in order to eliminate image broadening from the crystal thickness. Finite element calculations show that the thermal distortion of the crystals will affect the image size and bandpass.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray third-order nonlinear dynamical diffraction in a crystal

The dynamic diffraction of an X-ray wave in a crystal with a third-order nonlinear response to external field strength has been theoretically investigated. General equations for the wave propagation in crystal and nonlinear Takagi equations for both ideal and deformed crystals are derived. Integrals of motion are determined for the nonlinear problem of dynamic diffraction. The results of the numerical calculations of reflectivity in the symmetric Laue geometry for an incident plane wave and the intensity distributions on the output crystal surface for a point source are reported as an example.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Theoretical Study of the Two-Dimensional Point Focusing by Two Multilayer Laue Lenses.

Hard x-ray point focusing by two crossed multilayer Laue lenses is studied using a full-wave modeling approach. This study shows that for a small numerical aperture, the two consecutive diffraction processes can be decoupled into two independent ones in respective directions. Using this theoretical tool, we investigated adverse effects of various misalignments on the 2D focus profile and discussed the tolerance to them. We also derived simple expressions that described the required alignment accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ X-ray and IR probes relevant to Earth science at the Advanced Light Source at Lawrence Berkeley Laboratory

Access to synchrotron X-ray facilities has become an important aspect for many disciplines in experimental Earth science. This is especially important for studies that rely on probing samples in situ under natural conditions different from the ones found at the surface of the Earth. The non-ambient condition Earth science program at the Advanced Light Source (ALS), Lawrence Berkeley National Laboratory, offers a variety of tools utilizing the infra-red and hard X-ray spectrum that allow Earth scientists to probe Earth and environmental materials at variable conditions of pressure, stress, temperature, atmospheric composition, and humidity. These facilities are important tools for the user community in that they offer not only considerable capacity (non-ambient condition diffraction) but also complementary (IR spectroscopy, microtomography), and in some cases unique (Laue microdiffraction) instruments. The availability of the ALS’ in situ probes to the Earth science community grows especially critical during the ongoing dark time of the Advanced Photon Source in Chicago, which massively reduces available in situ synchrotron user time in North America.

58 GEOSCIENCES↗

Cyclic-loading-induced Accumulation of Geometrically Necessary Dislocations Near Grain Boundaries in an Ni-based Superalloy

In this study, the fatigue-induced microstructure produced in a nickel-based polycrystalline superalloy that was subjected to cyclic loading was characterized by polychromatic x-ray microdiffraction (PXM) together with in-situ neutron diffraction and transmission-electron microscopy (TEM). In-situ neutron-diffraction measurements reveal two distinct stages of the fatigue damage: cyclic hardening followed by cyclic softening. Three-dimensional spatially resolved PXM micro-Laue measurements find an increase in the density of geometrically necessary dislocations near the grain boundaries, which is accompanied by lattice rotations and grain subdivisions. The PXM results are in agreement with the in-situ neutron-diffraction and TEM results.

36 MATERIALS SCIENCE↗

Andreyivanovite: A Second New Phosphide from the Kaidun Meteorite

Andreyivanovite (ideally FeCrP) is another new phosphide species from the Kaidun meteorite, which fell in South Yemen in 1980. Kaidun is a unique breccia containing an unprecedented variety of fragments of different chondritic as well as achondritic lithologies. Andreyivanovite was found as individual grains and linear arrays of grains with a maximum dimension of 8 m within two masses of Fe-rich serpentine. In one sample it is associated with Fe-Ni-Cr sulfides and florenskyite (FeTiP). Andreyivanovite is creamy white in reflected light, and its luster is metallic. The average of nine electron microprobe analyses yielded the formula Fe(Cr0.587 Fe0.150 V0.109 Ti0.081 Ni0.060 Co0.002)P. Examination of single grains of andreyivanovite using Laue patterns collected by in-situ synchrotron X-ray diffraction (XRD), and by electron backscattered diffraction revealed that it is isostructural with florenskyite; we were unable to find single crystals of sufficient quality to perform a complete structure analysis. Andreyivanovite crystallizes in the space group Pnma, and has the anti-PbCl2 structure. Previously-determined cell constants of synthetic material [a = 5.833(1), b = 3.569(1), c = 6.658(1) A] were consistent with our XRD work. We used the XPOW program to calculate a powder XRD pattern; the 5 most intense reflections are d = 2.247 (I = 100), 2.074 (81), 2.258 (46), 1.785 (43), and 1.885 A (34). Andreyivanovite is the second new phosphide to be described from the Kaidun meteorite. Andreyivanovite could have formed as a result of cooling and crystallization of a melted precursor consisting mainly of Fe-Ni metal enriched in P, Ti, and Cr. Serpentine associated with andreyivanovite would then have formed during aqueous alteration on the parent asteroid. It is also possible that the andreyivanovite could have formed during aqueous alteration, however, artificial FeTiP has been synthesized only during melting experiments, at low oxygen fugacity, and there is no evidence that a hydrothermal genesis is reasonable.

Zolensky, Michael↗

Design and performance of an X-ray scanning microscope at the Hard X-ray Nanoprobe beamline of NSLS-II

A hard X-ray scanning microscope installed at the Hard X-ray Nanoprobe beamline of the National Synchrotron Light Source II has been designed, constructed and commissioned. The microscope relies on a compact, high stiffness, low heat dissipation approach and utilizes two types of nanofocusing optics. It is capable of imaging with ~15 nm × 15 nm spatial resolution using multilayer Laue lenses and 25 nm × 26 nm resolution using zone plates. Fluorescence, diffraction, absorption, differential phase contrast, ptychography and tomography are available as experimental techniques. The microscope is also equipped with a temperature regulation system which allows the temperature of a sample to be varied in the range between 90 K and 1000 K. The constructed instrument is open for general users and offers its capabilities to the material science, battery research and bioscience communities.

36 MATERIALS SCIENCE↗

Metallic ferromagnetic films with magnetic damping under 1.4 × 10 -3

Low-damping magnetic materials have been widely used in microwave and spintronic applications because of their low energy loss and high sensitivity. While the Gilbert damping constant can reach 10 -4 to 10 -5 in some insulating ferromagnets, metallic ferromagnets generally have larger damping due to magnon scattering by conduction electrons. Meanwhile, low-damping metallic ferromagnets are desired for charge-based spintronic devices. In this article, we report the growth of Co 25 Fe 75 epitaxial films with excellent crystalline quality evident by the clear Laue oscillations and exceptionally narrow rocking curve in the X-ray diffraction scans as well as from scanning transmission electron microscopy. Remarkably, the Co 25 Fe 75 epitaxial films exhibit a damping constant <1.4 × 10 -3 , which is comparable to the values for some high-quality Y 3 Fe 5 O 12 films. This record low damping for metallic ferromagnets offers new opportunities for charge-based applications such as spin-transfer-torque-induced switching and magnetic oscillations.

30 DIRECT ENERGY CONVERSION↗

Axial vs equatorial: Capturing the intramolecular charge transfer state geometry in conformational polymorphic crystals of a donor–bridge–acceptor dyad in nanosecond-time-scale

Two conformational polymorphs of a donor–bridge–acceptor (D-B-A) dyad, p-(CH 3 ) 2 N-C 6 H 4 -(CH 2 ) 2 -(1-pyrenyl)/PyCHDMA, were studied, where the electron donor (D) moiety p-(CH 3 ) 2 N-C 6 H 4 /DMA is connected through a bridging group (B), –CH 2 –CH 2 –, to the electron acceptor (A) moiety pyrene. Though molecular dyads like PyCHDMA have the potential to change solar energy into electrical current through the process of photoinduced intramolecular charge transfer (ICT), the major challenge is the real-time investigation of the photoinduced ICT process in crystals, necessary to design solid-state optoelectronic materials. The time-correlated single photon counting (TCSPC) measurements with the single crystals showed that the ICT state lifetime of the thermodynamic form, PyCHDMA1 (pyrene and DMA: axial), is ~3 ns, whereas, for the kinetic form, PyCHDMA20 (pyrene and DMA: equatorial), it is ~7 ns, while photoexcited with 375 nm radiation. The polymorphic crystals were photo-excited and subsequently probed with a pink Laue x-ray beam in time-resolved x-ray diffraction (TRXRD) measurements. The TRXRD results suggest that in the ICT state, due to electron transfer from the tertiary N-atom in DMA moiety to the bridging group and pyrene moiety, a decreased repulsion between the lone-pair and the bond-pair at N-atom induces planarity in the C–N–(CH 3 ) 2 moiety, in both polymorphs. The Natural Bond Orbital calculations and partial atomic charge analysis by Hirshfeld partitioning also corroborated the same. Although the interfragment charge transfer (IFCT) analysis using the TDDFT results showed that for the charge transfer excitation in both conformers, the electrons were transferred from the DMA moiety to mostly the pyrene moiety, the bridging group has little role to play in that.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend) This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 mu m spot of ~;;5x109 photons/ s (0.1percent bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored bytwo pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 um are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution (~;;0.2 mu m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10-5 strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution (~;;150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

47 OTHER INSTRUMENTATION↗

Point-group sensitive orientation mapping of non-centrosymmetric crystals

We demonstrate polarity-sensitive orientation mapping of non-centrosymmetric phases by Electron Backscatter Diffraction (EBSD). The method overcomes the restrictions of kinematic orientation determination by EBSD, which is limited to the centro-symmetric Laue-groups according to Friedel's rule. Using polycrystalline GaP as an example, we apply a quantitative pattern matching approach based on simulations using the dynamical theory of electron diffraction. This procedure results in a distinct assignment of the local orientation according to the non-centrosymmetric point group of the crystal structure under investigation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 {mu}m spot of {approx}5x10{sup 9} photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 {mu}m are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution ({approx}0.2 {mu}m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10{sup -5} strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution ({approx}150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculated efficiencies of three-material low stress coatings for diffractive x-ray transmission optics

Diffractive X-ray optical elements made by thin film coating techniques such as multilayer Laue lenses (MLL) and multilayer zone plates (MZP) are promising approaches to achieve resolutions in hard X-ray microscopy applications of less than 10 nm. The challenge is to make a lens with a large numerical aperture on the one hand and a decent working distance on the other hand. One of the limiting factors with the coated structures is the internal stress in the films, which can lead to significant bending of the substrate and various types of unwanted diffraction effects. Several approaches have been discussed to overcome this challenge. One of these is a three-material combination such as Mo/MoSi{sub 2}/Si, where four single layers per period are deposited. Mo and Si represent the absorber and spacer in this case while MoSi{sub 2} forms a diffusion barrier; in addition the thicknesses of absorber and spacer are chosen to minimize residual stress of the overall coating. Here the diffraction efficiency as well as the profile of the beam in the focal plane are discussed in order to find a tradeoff between lowest residual stress and best diffraction properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth of high quality single crystals of Bi{sub 2}Se{sub 3} topological insulator via solid state reaction method

Recently discovered, Topological Insulators (TIs) have garnered enormous amount of attention owing to its unique surface properties which has potential applications in the field of spintronics and other modern technologies. For all this, it should require a very good quality samples. There are a number of techniques suggested by people for the growth of good quality TIs. Here, we are reporting the growth of high quality single crystals of Bi{sub 2}Se{sub 3} (a TI) by slow cooling solid-state reaction method. X-ray diffraction measurements performed on a cleaved flake of single crystal Bi{sub 2}Se{sub 3} showed up with proper orientations of the crystal planes. High energy X-ray diffraction has been performed to confirm the stoichiometry of the compound and also recorded Laue patterns prove the single crystalline nature of Bi{sub 2}Se{sub 3}. Moreover, angle resolved photo-emission spectroscopy (ARPES) carried out on a flat crystal flake shows distinct Dirac dispersion of surface bands at the gamma point clarifying it as a 3D topological insulator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Selection of CVD Diamond Crystals for X-ray Monochromator Applications Using X-ray Diffraction Imaging

A set of 20 single crystal diamond plates synthesized using chemical vapor deposition (CVD) was studied using X-ray diffraction imaging to determine their applicability as side-bounce (single-reflection) Laue monochromators for synchrotron radiation. The crystal plates were of optical grade (as provided by the supplier) with (001) nominal surface orientation. High dislocation density was found for all samples. Distortions in the crystal lattice were quantified for low-index Laue reflections of interests using rocking curve topography. Maps of effective radius of curvature in the scattering plane were calculated using spline interpolation of the rocking curve peak position across the studied plates. For several selected plates, nearly flat regions with large effective radius of curvature were found (R 0 ≳ 30 - 70 m, some regions as large as 1 × 4 mm 2 ). The average width of the rocking curve for these regions was found to be about 150 μ rad (r.m.s.). These observations suggest that the selected CVD diamond plates could be used as intermediate-bandwidth monochromators refocusing the radiation source to a specific location downstream with close to 1:1 distance ratio.

36 MATERIALS SCIENCE↗

Polychromatic Microdiffraction Analysis of Defect Self-Organization in Shock Deformed Single Crystals

A spatially resolved X-ray diffraction method - with a submicron 3D resolution together with SEM and OIM analysis are applied to understand the arrangements of voids, geometrically necessary dislocations and strain gradient distributions in samples of Al (1 2 3) and Cu (0 0 1) single crystals shocked to incipient spallation fracture. We describe how geometrically necessary dislocations and the effective strain gradient alter white beam Laue patterns of the shocked materials. Several distinct structural zones are observed at different depths under the impact surface. The density of geometrically necessary dislocations (GNDs) is extremely high near the impact and back surface of the shock recovered crystals. The spall region is characterized by a large density of mesoscale voids and GNDs. The spall region is separated from the impact and back surfaces by compressed regions with high total dislocation density but lower GNDs density. Self-organization of shear bands is observed in the shock recovered Cu single crystal.

36 MATERIALS SCIENCE↗