Search NASA⌕ Search

SEARCH · Search NASA

Results for “Level Set Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Method to Automate the Segmentation of the GTV and ITV for Lung Tumors

Four-dimensional computed tomography (4D-CT) is a useful tool in the treatment of tumors that undergo significant motion. To fully utilize 4D-CT motion information in the treatment of mobile tumors such as lung cancer, autosegmentation methods will need to be developed. Using autosegmentation tools in the Pinnacle{sup 3} v8.1t treatment planning system, 6 anonymized 4D-CT data sets were contoured. Two test indices were developed that can be used to evaluate which autosegmentation tools to apply to a given gross tumor volume (GTV) region of interest (ROI). The 4D-CT data sets had various phase binning error levels ranging from 3% to 29%. The appropriate autosegmentation method (rigid translational image registration and deformable surface mesh) was determined to properly delineate the GTV in all of the 4D-CT phases for the 4D-CT data sets with binning errors of up to 15%. The ITV was defined by 2 methods: a mask of the GTV in all 4D-CT phases and the maximum intensity projection. The differences in centroid position and volume were compared with manual segmentation studies in literature. The indices developed in this study, along with the autosegmentation tools in the treatment planning system, were able to automatically segment the GTV in the four 4D-CTs with phase binning errors of up to 15%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automatic microseismic event picking via unsupervised machine learning

SUMMARY Effective and efficient arrival picking plays an important role in microseismic and earthquake data processing and imaging. Widely used short-term-average long-term-average ratio (STA/LTA) based arrival picking algorithms suffer from the sensitivity to moderate-to-strong random ambient noise. To make the state-of-the-art arrival picking approaches effective, microseismic data need to be first pre-processed, for example, removing sufficient amount of noise, and second analysed by arrival pickers. To conquer the noise issue in arrival picking for weak microseismic or earthquake event, I leverage the machine learning techniques to help recognizing seismic waveforms in microseismic or earthquake data. Because of the dependency of supervised machine learning algorithm on large volume of well-designed training data, I utilize an unsupervised machine learning algorithm to help cluster the time samples into two groups, that is, waveform points and non-waveform points. The fuzzy clustering algorithm has been demonstrated to be effective for such purpose. A group of synthetic, real microseismic and earthquake data sets with different levels of complexity show that the proposed method is much more robust than the state-of-the-art STA/LTA method in picking microseismic events, even in the case of moderately strong background noise.

Chen, Yangkang↗

The clustering of theSDSS-IV extended Baryon Oscillation Spectroscopic Survey DR14 quasar sample: measuring the anisotropic baryon acoustic oscillations with redshift weights

We present an anisotropic analysis of baryon acoustic oscillation (BAO) signal from the Sloan Digital Sky Survey IV extended Baryon Oscillation Spectroscopic Survey Data Release 14 quasar sample. The sample consists of 147 000 quasars distributed over a redshift range of 0.8 < z < 2.2. We apply the redshift weights technique to the clustering of quasars in this sample and achieve a 4.6 per cent measurement of the angular distance measurement DM at z = 2.2 and Hubble parameter H at z = 0.8. We parametrize the distance-redshift relation, relative to a fiducial model, as a Taylor series. The coefficients of this expansion are used to reconstruct the distance-redshift relation and obtain distance and Hubble parameter measurements at all redshifts within the redshift range of the sample. Reporting the result at two characteristic redshifts, we determine DM(z = 1) = 3405 ± 305 (rd/rd, fid) Mpc, H(z=1) = 120.7± 7.3 (r_d,fid / r_d) km s^{-1} Mpc^{-1} and DM(z = 2) = 5325 ± 249 (rd/rd, fid) Mpc, H(z=2) = 189.9± 32.9 (r_d,fid / r_d) km s^{-1} Mpc^{-1}. These measurements are highly correlated. We assess the outlook of BAO analysis from the final quasar sample by testing the method on a set of mocks that mimic the noise level in the final sample. We demonstrate on these mocks that redshift weighting shrinks the measurement error by over 25 per cent on average. We conclude redshift weighting can bring us closer to the cosmological goal of the final quasar sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Population of the giant pairing vibration

Background: We present that the giant pairing vibration (GPV), a correlated two-nucleon mode in the second shell above the Fermi surface, has long been predicted and expected to be strongly populated in two-nucleon transfer cross sections similar to those of the normal pairing vibration. Recent experiments have provided evidence for this mode in 14,15 C but, despite sensitive studies, it has not been definitively identified in either Sn or Pb nuclei where pairing correlations are known to play a crucial role. Purpose: Our aim is to test whether features inherent to the mixing of bound and unbound levels might account for this and to study the effect in a simple and intuitively clear approach. Method: We study the mixing of unbound levels in a set of toy models that capture the essential physics of the GPV, along with a more realistic calculation including distorted-wave Born approximation transfer amplitudes. Results: The calculated (relative) cross section to populate a simulated GPV state is effectively low, compared to the case of bound levels with no widths Conclusions: The mixing turns out to be only a minor contributor to the weak population. Rather, the main reason is the melting of the GPV peak due to the width it acquires from the low orbital angular momentum single-particle states playing a dominant role in two-nucleon transfer amplitudes. Lastly, this effect, in addition to a severe Q-value mismatch, may account for the elusive nature of this mode in (t,p) and (p,t) reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstructing magnetic deflections from sets of proton images using differential evolution

Proton imaging is a powerful technique for imaging electromagnetic fields within an experimental volume, in which spatial variations in proton fluence are a result of deflections to proton trajectories due to interaction with the fields. When deflections are large, proton trajectories can overlap, and this nonlinearity creates regions of greatly increased proton fluence on the image, known as caustics. The formation of caustics has been a persistent barrier to reconstructing the underlying fields from proton images. We have developed a new method for reconstructing the path-integrated magnetic fields, which begins to address the problem posed by caustics. Our method uses multiple proton images of the same object, each image at a different energy, to fill in the information gaps and provide some uniqueness when reconstructing caustic features. We use a differential evolution algorithm to iteratively estimate the underlying deflection function, which accurately reproduces the observed proton fluence at multiple proton energies simultaneously. We test this reconstruction method using synthetic proton images generated for three different, cylindrically symmetric field geometries at various field amplitudes and levels of proton statistics and present reconstruction results from a set of experimental images. Here, the method we propose requires no assumption of deflection linearity and can reliably solve for fields underlying linear, nonlinear, and caustic proton image features for the selected geometries and is shown to be fairly robust to noise in the input proton intensity.

47 OTHER INSTRUMENTATION↗

Design of layered transformation-optics devices of arbitrary shape

Transformation-optics devices of arbitrary shapes usually result in material parameters inside the device that feature level sets of different shapes. Consequently, these devices cannot easily be implemented using a layered architecture and thus are, generally, more difficult to realize in practice. We present a method of designing two-dimensional transformation-optics devices of arbitrary shapes characterized by material parameters of same-level sets, thus suitable to be implemented through concentric layers, each layer being made of a single type of material or metamaterial. Remarkably, we show that transformations leading to such designs are obtained from solutions to the well-known eikonal equation. This approach allows fabrication techniques developed for cylindrical designs of circular cross section to be directly applied to devices of other shapes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated noninvasive classification of renal cancer on multiphase CT

Purpose: To explore the added value of the shape of renal lesions for classifying renal neoplasms. To investigate the potential of computer-aided analysis of contrast-enhanced computed-tomography (CT) to quantify and classify renal lesions. Methods: A computer-aided clinical tool based on adaptive level sets was employed to analyze 125 renal lesions from contrast-enhanced abdominal CT studies of 43 patients. There were 47 cysts and 78 neoplasms: 22 Von Hippel-Lindau (VHL), 16 Birt-Hogg-Dube (BHD), 19 hereditary papillary renal carcinomas (HPRC), and 21 hereditary leiomyomatosis and renal cell cancers (HLRCC). The technique quantified the three-dimensional size and enhancement of lesions. Intrapatient and interphase registration facilitated the study of lesion serial enhancement. The histograms of curvature-related features were used to classify the lesion types. The areas under the curve (AUC) were calculated for receiver operating characteristic curves. Results: Tumors were robustly segmented with 0.80 overlap (0.98 correlation) between manual and semi-automated quantifications. The method further identified morphological discrepancies between the types of lesions. The classification based on lesion appearance, enhancement and morphology between cysts and cancers showed AUC = 0.98; for BHD + VHL (solid cancers) vs. HPRC + HLRCC AUC = 0.99; for VHL vs. BHD AUC = 0.82; and for HPRC vs. HLRCC AUC = 0.84. All semi-automated classifications were statistically significant (p < 0.05) and superior to the analyses based solely on serial enhancement. Conclusions: The computer-aided clinical tool allowed the accurate quantification of cystic, solid, and mixed renal tumors. Cancer types were classified into four categories using their shape and enhancement. Comprehensive imaging biomarkers of renal neoplasms on abdominal CT may facilitate their noninvasive classification, guide clinical management, and monitor responses to drugs or interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximum likelihood method to correct for missed levels based on the {Delta}{sub 3}(L) statistic

The {Delta}{sub 3}(L) statistic of random matrix theory is defined as the average of a set of random numbers {l_brace}{delta}{r_brace}, derived from a spectrum. The distribution p({delta}) of these random numbers is used as the basis of a maximum likelihood method to gauge the fraction x of levels missed in an experimental spectrum. The method is tested on an ensemble of depleted spectra from the Gaussian orthogonal ensemble (GOE) and accurately returned the correct fraction of missed levels. Neutron resonance data and acoustic spectra of an aluminum block were analyzed. All results were compared with an analysis based on an established expression for {Delta}{sub 3}(L) for a depleted GOE spectrum. The effects of intruder levels are examined and seen to be very similar to those of missed levels. Shell model spectra were seen to give the same p({delta}) as the GOE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Eulerian adaptive finite-difference method for high-velocity impact and penetration problems

Owing to the complex processes involved, faithful prediction of high-velocity impact events demands a simulation method delivering efficient calculations based on comprehensively formulated constitutive models. Such an approach is presented herein, employing a weighted essentially non-oscillatory (WENO) method within an adaptive mesh refinement (AMR) framework for the numerical solution of hyperbolic partial differential equations. Applied widely in computational fluid dynamics, these methods are well suited to the involved locally non-smooth finite deformations, circumventing any requirement for artificial viscosity functions for shock capturing. Application of the methods is facilitated through using a model of solid dynamics based upon hyper-elastic theory comprising kinematic evolution equations for the elastic distortion tensor. The model for finite inelastic deformations is phenomenologically equivalent to Maxwell s model of tangential stress relaxation. Closure relations tailored to the expected high-pressure states are proposed and calibrated for the materials of interest. Sharp interface resolution is achieved by employing level-set functions to track boundary motion, along with a ghost material method to capture the necessary internal boundary conditions for material interactions and stress-free surfaces. The approach is demonstrated for the simulation of high velocity impacts of steel projectiles on aluminium target plates in two and three dimensions.

Barton, Philip T.↗

A conformal decomposition finite element method for modeling stationary fluid interface problems.

A method is developed for modeling fluid transport in domains that do not conform to the finite element mesh. One or more level set functions are used to describe the fluid domain. A background, non-conformal mesh is decomposed into elements that conform to the level set interfaces. Enrichment takes place by adding nodes that lie on the interfaces. Unlike other enriched finite element methods, the proposed technique requires no changes to the underlying element assembly, element interpolation, or element quadrature. The complexity is entirely contained within the element decomposition routines. It is argued that the accuracy of the method is no less than that for eXtended Finite Element Methods (XFEM) with Heaviside enrichment. The accuracy is demonstrated using multiple numerical tests. In all cases, optimal rates of convergence are obtained for both volume and surface quantities. Jacobi preconditioning is shown to remove the ill-conditioning that may result from the nearly degenerate conformal elements.

97 MATHEMATICS AND COMPUTING↗

A critical comparison of CH∙∙∙π versus π∙∙∙π interactions in the benzene dimer: obtaining benchmarks at the CCSD(T) level and assessing the accuracy of lower scaling methods

In this study, we have established CCSD(T)/CBS (Complete Basis Set) limits for 3 stationary points on the benzene dimer potential energy surface, corresponding to the π∙∙∙π (parallel displaced or PD(C 2h ), minimum) and CH∙∙∙π (T-shaped or T(C 2v ), transition state) and tilted T-shaped (or TT(Cs), minimum) bonding scenarios considering both the structure and binding energy. The CCSD(T)/CBS binding energies are -2.65 ± 0.02 (PD), -2.74 ± 0.03 (T), and -2.83 ± 0.01 kcal mol -1 (TT). To this end, the CH∙∙∙π is ~0.2 kcal mol -1 stronger than the π∙∙∙π interaction, whereas the tilting of the CH donating benzene molecule with respect to the other benzene is worth 0.1 kcal mol -1 . As previously discussed in the literature, the MP2 level of theory does not provide a close match for either the energy or structure, yet the SCS-MP2 yields structures in excellent agreement with respect to the CCSD(T) result. It is found that the SCS-MI-MP2 also gives optimized structures very close to SCS-MP2 (within ~0.01 Å of the benchmark). Despite the closer match in structure, the spin-biased MP2 methods (SCS-, SCS-MI-, and SOS-MP2) incorrectly predict the relative stabilities of the isomers. That said, none of the spin biased MP2 methods offers a good compromise between energy and structure for the systems examined. Finally, the CCSD(T)/CBS benchmarks were used to assess the performance of 13 DFT functionals selected from different rungs of Jacob's ladder. Several functionals such as TPSS-D3, B3LYP-D3, B97-D, B97-D3, and B2PLYP-D3 provided a good description of the binding energies for both CH∙∙∙π and π∙∙∙π interactions, yielding values within 6% of the CCSD(T)/CBS benchmark values. Unlike the MP2 methods, these functionals correctly predict the relative stability of the PD(C 2h ) and T(C 2v ) dimers. Further, we find that there is no systematic improvement as Jacob's ladder is ascended (increased complexity of functional). The best functionals that result in a good compromise between structure and energy accuracy are B97-D3 and B2PLYP-D3 for both the CH∙∙∙π and π∙∙∙π interaction. Despite the impressive performance of these functionals, a challenge that remains is ensuring the transferability of these density functionals in accurately describing the interaction between dimers of larger aromatic molecules, the latter requiring high-level benchmarks for these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The inter- and intrafraction reproducibilities of three common IMRT delivery techniques

Purpose: Intensity modulated radiation therapy (IMRT) treatment delivery requires higher precision than conventional 3D treatment delivery because of the sensitivity of the resulting dose to small geometric misalignment of the modulated beamlets. The chosen treatment delivery technique will affect the treatment precision in different ways, based on the characteristics of the delivery method. Delivery using a multileaf collimator (MLC) can reduce treatment time and therapist workload, but typically requires a greater number of monitor units and the fields are prone to both systematic and random leaf positioning errors. An alternative to MLC-based fields, patient specific brass compensators, do not suffer from these leaf positioning errors. In our study, we set out to investigate which delivery method will provide the highest levels of dosimetric reproducibility and the minimum amount of interfraction variability. Methods: In our study, a seven field IMRT plan for a head and neck treatment was created using the Pinnacle{sup 3} treatment planning system and the intensity maps for each field were obtained. The intensity maps of the fields were delivered with a Varian 2100C/D linear accelerator, using solid compensators and sliding window (SW) and step-and-shoot (SS) MLC segments. Three fields were selected from the seven-beam IMRT plan for comparison. Analysis was carried out using the MatriXX ion chamber array, radiochromic film, and Varian dynalog files. Results: Our results show that the error in MLC leaf positioning has no gantry angle dependence. The compensator and SW deliveries showed excellent agreement, even when stricter than usual gamma criteria were applied. However, we noted that under these strict conditions, the SS fields had at least ten times more pixels out of range than did the compensators. When using step-and-shoot MLC fields, it was observed that the increase in dose rate or the increase of MU/segment degrades the quality of the plan. Analysis of the dynalog files showed that while each individual field had its own propensity for error, all fields showed the same trend: a greater percentage of time the leaves are out of position as dose rate increases, MUs decrease, or both. Conclusions: The compensator-based field and both types of MLC-based fields have MatriXX results that are within the clinically acceptable tolerance of 3% dose difference and 2 mm DTA. However, when the criteria are tightened, it becomes evident that the compensators have a definite advantage over their comparable MLC-based competitors in terms of interfraction reproducibility. Fewer monitor units are required to deliver each portal, potentially improving patient outcomes and reducing unwanted side effects to both patients and therapists. In centers without MLC, compensators represent a simple and cost effective way to offer patients state of the art treatment. Based on the results of this study, compensator-based IMRT is a reliable, viable option for use in clinics both with and without MLC-equipped linacs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Delineating Facies Spatial Distribution by Integrating Ensemble Data Assimilation and Indicator Geostatistics with Level Set Transformation.

A new approach is developed to delineate the spatial distribution of discrete facies (geological units that have unique distributions of hydraulic, physical, and/or chemical properties) conditioned not only on direct data (measurements directly related to facies properties, e.g., grain size distribution obtained from borehole samples) but also on indirect data (observations indirectly related to facies distribution, e.g., hydraulic head and tracer concentration). Our method integrates for the first time ensemble data assimilation with traditional transition probability-based geostatistics. The concept of level set is introduced to build shape parameterization that allows transformation between discrete facies indicators and continuous random variables. The spatial structure of different facies is simulated by indicator models using conditioning points selected adaptively during the iterative process of data assimilation. To evaluate the new method, a two-dimensional semi-synthetic example is designed to estimate the spatial distribution and permeability of two distinct facies from transient head data induced by pumping tests. The example demonstrates that our new method adequately captures the spatial pattern of facies distribution by imposing spatial continuity through conditioning points. The new method also reproduces the overall response in hydraulic head field with better accuracy compared to data assimilation with no constraints on spatial continuity on facies.

97 MATHEMATICS AND COMPUTING↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measuring the Error in Approximating the Sub-Level Set Topology of Sampled Scalar Data

This paper studies here the influence of the definition of neighborhoods and methods used for creating point connectivity on topological analysis of scalar functions. It is assumed that a scalar function is known only at a finite set of points with associated function values. In order to utilize topological approaches to analyze the scalar-valued point set, it is necessary to choose point neighborhoods and, usually, point connectivity to meaningfully determine critical-point behavior for the point set. Two distances are used to measure the difference in topology when different point neighborhoods and means to define connectivity are used: (i) the bottleneck distance for persistence diagrams and (ii) the distance between merge trees. Usually, these distances define how different scalar functions are with respect to their topology. These measures, when properly adapted to point sets coupled with a definition of neighborhood and connectivity, make it possible to understand how topological characteristics depend on connectivity. Noise is another aspect considered. Five types of neighborhoods and connectivity are discussed: (i) the Delaunay triangulation; (ii) the relative neighborhood graph; (iii) the Gabriel graph; (iv) the k-nearest-neighbor (KNN) neighborhood; and (v) the Vietoris–Rips complex. It is discussed in detail how topological characterizations depend on the chosen connectivity.

97 MATHEMATICS AND COMPUTING↗

A standardized approach to PV system performance model validation.

PV performance models are used to predict how much energy a PV system will produce at a given location and subject to prescribed weather conditions. These models are commonly used by project developers to choose between module technologies and array designs (e.g., fixed tilt vs. tracking) for a given site or to choose between different geographic locations, and are used by the financial community to establish project viability. Available models can differ significantly in their underlying mathematical formulations and assumptions and in the options available to the analyst for setting up a simulation. Some models lack complete documentation and transparency, which can result in confusion on how to properly set up, run, and document a simulation. Furthermore, the quality and associated uncertainty of the available data upon which these models rely (e.g., irradiance, module parameters, etc.) is often quite variable and frequently undefined. For these reasons, many project developers and other industry users of these simulation tools have expressed concerns related to the confidence they place in PV performance model results. To address this problem, we propose a standardized method for the validation of PV system-level performance models and a set of guidelines for setting up these models and reporting results. This paper describes the basic elements for a standardized model validation process adapted especially for PV performance models, suggests a framework to implement the process, and presents an example of its application to a number of available PV performance models.

14 SOLAR ENERGY↗

Delineating Facies Spatial Distribution by Integrating Ensemble Data Assimilation and Indicator Geostatistics with Level-Set Transformation

The facies-based approach has been widely adopted to delineate an aquifer into distinct geological units with unique distributions of hydraulic, physical, and/or chemical properties. The recent development in ensemble-based data assimilation methods allows both the direct and indirect data to be used to improve facies delineation. A major difficulty in those applications is to honor the spatial continuity and avoid overfitting after data assimilation. We introduce a new facies delineation framework to integrate ensemble data assimilation with traditional transition probability-based geostatistics. A level-set concept is used to parametrize discrete facies indicators and for updating facies shape. During the iterative data assimilation process, we impose spatial continuity by conditioning facies field generation on points selected adaptively based on their sensitivity to observation data. This reconditioning step is a key step to maintain spatial continuity and overcome over-fitting problems in inversion. We selected two examples to evaluate the performance of the new framework in estimating facies-based permeability field. The first example is a two-dimensional synthetic system with transient head data induced by pumping tests used for delineating two facies. The second example is a three-dimensional case with three facies, conceptualized from a field tracer experiment within the Columbia River corridor in Washington State, USA. Both examples demonstrate that the new method can adequately capture the spatial pattern of hydrofacies with reconditioning, which leads to the improved prediction of system behaviors.

Song, Xuehang↗