Search NASA⌕ Search

SEARCH · Search NASA

Results for “Limit of detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Emission Spectra of Uranium Particulates at High Temperature

The emission spectrum of micron-scale uranium particulates at high temperatures in the ultraviolet, visible, and near-infrared spectral regions is investigated using a heterogeneous shock tube. Temperatures from 3000 to 9000 K are characterized in an inert argon environment and with incremental amounts of added oxygen. Atomic line spectra do not emerge above the continuum emission spectrum until between 4500 and 5000 K in pure argon, and 6100 and 6600 K in 1% oxygen. For 5% oxygen, however, the threshold for atomic emission drops below 3800 K. Uranium monoxide molecular emission in the strongest visible band at 595.4 nm is not observed at any condition. Uncertainties in particle temperature determination in high-temperature shock tube environments are discussed, and limitations to such measurements are presented, such as those from experimental factors such as the powder loading method and expected detection limits of uranium species in relevant conditions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A New Field Instrument for Leaf Volatiles Reveals an Unexpected Vertical Profile of Isoprenoid Emission Capacities in a Tropical Forest

Both plant physiology and atmospheric chemistry are substantially altered by the emission of volatile isoprenoids (VI), such as isoprene and monoterpenes, from plant leaves. Yet, since gaining scientific attention in the 1950’s, empirical research on leaf VI has been largely confined to laboratory experiments and atmospheric observations. Here, we introduce a new field instrument designed to bridge the scales from leaf to atmosphere, by enabling precision VI detection in real time from plants in their natural ecological setting. With a field campaign in the Brazilian Amazon, we reveal an unexpected distribution of leaf emission capacities (EC) across the vertical axis of the forest canopy, with EC peaking in the mid-canopy instead of the sun-exposed canopy surface, and moderately high emissions occurring in understory specialist species. Compared to the simple interpretation that VI protect leaves from heat stress at the hot canopy surface, our results encourage a more nuanced view of the adaptive role of VI in plants. We infer that forest emissions to the atmosphere depend on the dynamic microenvironments imposed by canopy structure, and not simply on canopy surface conditions. We provide a new emissions inventory from 52 tropical tree species, revealing moderate consistency in EC within taxonomic groups. We highlight priorities in leaf volatiles research that require field-portable detection systems. Our self-contained, portable instrument provides real-time detection and live measurement feedback with precision and detection limits better than 0.5 nmol VI m -2 leaf s -1 . We call the instrument ‘PORCO’ based on the gas detection method: photoionization of organic compounds. We provide a thorough validation of PORCO and demonstrate its capacity to detect ecologically driven variation in leaf emission rates and thus accelerate a nascent field of science: the ecology and ecophysiology of plant volatiles.

54 ENVIRONMENTAL SCIENCES↗

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Saturn's ionosphere: Inferred electron densities

During the two Voyager encounters with Saturn, radio bursts were detected which appear to have originated from atmospheric lightning storms. Although these bursts generally extended over frequencies from as low as 100 kHz to the upper detection limit of the instrument, 40 MHz, they often exhibited a sharp but variable low frequency cutoff below which bursts were not detected. We interpret the variable low-frequency extent of these bursts to be due to the reflection of the radio waves as they propagate through an ionosphere which varies with local time. We obtain estimates of electron densities at a variety of latitude and local time locations. These compare well with the dawn and dusk densitis measured by the Pioneer 11 Voyager Radio Science investigations, and with model predictions for dayside densities. However, we infer a two-order-of-magnitude diurnal variation of electron density, which had not been anticipated by theoretical models of Saturn's ionosphere, and an equally dramatic extinction of ionospheric electron density by Saturn's rings.

Kaiser, M. L.↗

Saturn's ionosphere - Inferred electron densities

During the two Voyager encounters with Saturn, radio bursts were detected which appear to have originated from atmospheric lightning storms. Although these bursts generally extended over frequencies from as low as 100 kHz to the upper detection limit of the instrument, 40 MHz, they often exhibited a sharp but variable low frequency cutoff below which bursts were not detected. We interpret the variable low-frequency extent of these bursts to be due to the reflection of the radio waves as they propagate through an ionosphere which varies with local time. We obtain estimates of electron densities at a variety of latitude and local time locations. These compare well with the dawn and dusk densities measured by the Pioneer 11 Voyager Radio Science investigations, and with model predictions for dayside densities. However, we infer a two-order-of-magnitude diurnal variation of electron density, which had not been anticipated by theoretical models of Saturn's ionosphere, and an equally dramatic extinction of ionospheric electron density by Saturn's rings. Previously announced in STAR as N84-17102

Kaiser, M. L.↗

The enigmatic jets of NGC 1097

We use deep optical images, spectroscopy, and radio observations of the optical jets in NGC 1097 to constrain models for their origin. Our detection limit on 20-cm radio emission from the region of the optical jets is ten times fainter than previous results. We detect no steep-spectrum emission at 90-cm associated with fossil radio lobes. If star formation in the optical jets was triggered by ejection of relativistic matter from an active nucleus, the time of activity was at least 10 million years ago.

Wehrle, Ann E.↗

Searching for Faint Companions to Nearby Stars with the Hubble Space Telescope

A search for faint companions (FC's) to selected stars within 5 pc of the Sun using the Hubble Space Telescope's Planetary Camera (PC) has been initiated. To assess the PC's ability to detect FCs, we have constructed both model and laboratory-simulated images and compared them to actual PC images. We find that the PC's point-spread function (PSF) is 3-4 times brighter over the angular range 2-5 sec than the PSF expected for a perfect optical system. Azimuthal variations of the PC's PSF are 10-20 times larger than expected for a perfect PSF. These variations suggest that light is scattered nonuniformly from the surface of the detector. Because the anomalies in the PC's PSF cannot be precisely simulated, subtracting a reference PSF from the PC image is problematic. We have developed a computer algorithm that identifies local brightness anomalies within the PSF as potential FCs. We find that this search algorithm will successfully locate FCs anywhere within the circumstellar field provided that the average pixel signal from the FC is at least 10 sigma above the local background. This detection limit suggests that a comprehensive search for extrasolar Jovian planets with the PC is impractical. However, the PC is useful for detecting other types of substellar objects. With a stellar signal of 10(exp 9) e(-), for example, we may detect brown dwarfs as faint as M(sub I) = 16.7 separated by 1 sec from alpha Cen A.

Schroeder, Daniel J.↗

Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

Waller, Jess M.↗

The Infrared-Optical Telescope (IRT) of the Exist Observatory

The IRT is a 1.1m visible and infrared passively cooled telescope, which can locate, identify and obtain spectra of GRB afterglows at redshifts up to z 20. It will also acquire optical-IR, imaging and spectroscopy of AGN and transients discovered by the EXIST (The Energetic X-ray Imaging Survey Telescope). The IRT imaging and spectroscopic capabilities cover a broad spectral range from 0.32.2m in four bands. The identical fields of view in the four instrument bands are each split in three subfields: imaging, objective prism slitless for the field and objective prism single object slit low resolution spectroscopy, and high resolution long slit on single object. This allows the instrument, to do simultaneous broadband photometry or spectroscopy of the same object over the full spectral range, thus greatly improving the efficiency of the observatory and its detection limits. A prompt follow up (within three minutes) of the transient discovered by the EXIST makes IRT a unique tool for detection and study of these events, which is particularly valuable at wavelengths unavailable to the ground based observatories.

Kutyrev, Alexander↗

2014 ISS Potable Water Characterization and Continuation of the Dimethylsilanediol Chronicle

During 2014 the crews from Expeditions 38-41 were in residence on the International Space Station (ISS). In addition to the U.S. potable water reclaimed from humidity condensate and urine, the other water supplies available for their use were Russian potable water reclaimed from condensate and Russian ground-supplied potable water. Beginning in June of 2014 and for the fourth time since 2010, the product water from the U.S. water processor assembly (WPA) experienced a rise in the total organic carbon (TOC) level due to organic contaminants breaking through the water treatment process. Results from ground analyses of ISS archival water samples returned on Soyuz 38 confirmed that dimethylsilanediol was once again the contaminant responsible for the rise. With this confirmation in hand and based upon the low toxicity of dimethylsilanediol, a waiver was approved to allow the crew to continue to consume the water after the TOC level exceeded the U.S. Segment limit of 3 mg/L. Several weeks after the WPA multifiltration beds were replaced, the TOC levels returned to below the method detection limit of the onboard TOC analyzer (TOCA) as anticipated based upon experience from previous rises. This paper presents and discusses the chemical analysis results for the ISS archival potable-water samples returned in 2014 and analyzed by the Johnson Space Center's Toxicology and Environmental Chemistry laboratory. These results showed compliance with ISS potable water quality standards and indicated that the potable-water supplies were acceptable for crew consumption. Although dimethylsilanediol levels were at times elevated, they remained well below the 35 mg/L health limit so the continued consumption of the U.S. potable water was considered a low risk to crew health and safety. Excellent agreement between in-flight and archival sample TOC data confirmed that the TOCA performed optimally and continued to serve as a vital tool for monitoring organic breakthrough and planning remediation action.

Straub, John E., II↗

The Atacama Cosmology Telescope: A Search for Planet 9

We use Atacama Cosmology Telescope (ACT) observations at 98 GHz (2015–2019), 150 GHz (2013–2019), and 229 GHz (2017–2019) to perform a blind shift-and-stack search for Planet 9. The search explores distances from 300 au to 2000 au and velocities up to 6farcm3 per year, depending on the distance (r). For a 5 Earth-mass Planet 9 the detection limit varies from 325 au to 625 au, depending on the sky location. For a 10 Earth-mass planet the corresponding range is 425 au to 775 au. The predicted aphelion and most likely location of the planet corresponds to the shallower end of these ranges. The search covers the whole 18,000 square degrees of the ACT survey. No significant detections are found, which is used to place limits on the millimeter-wave flux density of Planet 9 over much of its orbit. Overall we eliminate roughly 17% and 9% of the parameter space for a 5 and 10 Earth-mass Planet 9, respectively. These bounds approach those of a recent INPOP19a ephemeris-based analysis, but do not exceed it. We also provide a list of the 10 strongest candidates from the search for possible follow-up. More generally, we exclude (at 95% confidence) the presence of an unknown solar system object within our survey area brighter than 4–12 mJy (depending on position) at 150 GHz with current distance 300 au < r < 600 au and heliocentric angular velocityy <?CDATA $1\buildrel{\,\prime}\over{.} 5\,{\mathrm{yr}}^{-1}\lt v\cdot \tfrac{500\,\mathrm{au}}{r}\lt 2\buildrel{\prime\prime}\over{.} 3\,{\mathrm{yr}}^{-1}$?> 1 .' 5 yr – 1 < v · 500 au r < 2 ." 3 yr – 1 , corresponding to low-to-moderate eccentricities. These limits worsen gradually beyond 600 au, reaching 5–15 mJy by 1500 au.

79 ASTRONOMY AND ASTROPHYSICS↗

The Atacama Cosmology Telescope: A search for Planet 9

We use Atacama Cosmology Telescope (ACT) observations at 98 GHz (2015–2019), 150 GHz (2013–2019), and 229 GHz (2017–2019) to perform a blind shift-and-stack search for Planet 9. The search explores distances from 300 au to 2000 au and velocities up to 6\farcm3 per year, depending on the distance (r). For a 5 Earth-mass Planet 9 the detection limit varies from 325 au to 625 au, depending on the sky location. For a 10 Earth-mass planet the corresponding range is 425 au to 775 au. The predicted aphelion and most likely location of the planet corresponds to the shallower end of these ranges. The search covers the whole 18,000 square degrees of the ACT survey. No significant detections are found, which is used to place limits on the millimeter-wave flux density of Planet 9 over much of its orbit. Overall we eliminate roughly 17% and 9% of the parameter space for a 5 and 10 Earth-mass Planet 9, respectively. These bounds approach those of a recent INPOP19a ephemeris-based analysis, but do not exceed it. We also provide a list of the 10 strongest candidates from the search for possible follow-up. More generally, we exclude (at 95% confidence) the presence of an unknown solar system object within our survey area brighter than 4–12 mJy (depending on position) at 150 GHz with current distance 300 au < r < 600 au and heliocentric angular velocity 1\farcm5 per yr < v x (500au/r) < 2\farcs3 per yr, corresponding to low-to-moderate eccentricities. These limits worsen gradually beyond 600 au, reaching 5–15 mJy by 1500 au.

Sigurd Naess↗

Chandra Observations of Unresolved X-Ray Sources Around Two Clusters of Galaxies

We have searched for unresolved X-ray sources in the vicinity of two rich clusters of galaxies: Abell 1995 (A1995) and MS 0451.6-0305 (MS0451), using the Chandra X-ray observatory. We detected significantly more unresolved sources around A1995 than expected based on the number of X-ray sources to the same flux limit detected in deep Chandra observations of blank fields. Previous studies have also found excess X-ray sources in the vicinity of several nearby clusters of galaxies using ROSAT (Roentgen Satellite), and recently in more distant (z is approximately 0.5) clusters (RXJ0030 and 3C295) using Chandra. In contrast, we detect only 14 unresolved X-ray sources near MS0451, which is consistent with the number expected from a cluster-free background. We determine the luminosity functions of the extra sources under the assumption that they are at the distance of their respective clusters. The characteristic luminosity of the extra sources around A1995 must be an order of magnitude fainter than that of the extra sources around RXJ0030 and 3C295. The apparent lack of extra sources around MS0451 is consistent with its greater distance and the same characteristic luminosity as the A1995 sources. Hardness ratios suggest that, on average, the extra sources in A1995 may have harder spectra than those of RXJ0030 and 3C295. These results indicate that different classes of objects may dominate in different clusters, perhaps depending on the formation history and/or dynamical state of the accompanying cluster.

Molnar, Sandor M.↗

Direct and Sensitive Electrochemical Evaluation of Pramipexole Using Graphitic Carbon Nitride (gCN) Sensor

Pramipexole (PMXL) belongs to the benzothiazole class of aromatic compounds and is used in treating Parkinson’s disease; however, overdosage leads to some abnormal effects that could trigger severe side effects. Therefore, it demands a sensitive analytical tool for trace level detection. In this work, we successfully developed an electrochemical sensor for the trace level detection of PMXL, using the voltammetric method. For the analysis, graphitic carbon nitride (gCN) was opted and synthesized by using a high-temperature thermal condensation method. The synthesized nanoparticles were employed for surface characterization, using transmission electron microscopy (TEM), X-ray diffraction (XRD), and atomic force microscopy (AFM) techniques. The electrochemical characterization of the material was evaluated by using the electrochemical impedance spectroscopy (EIS) technique to evaluate the solution–electrode interface property. The cyclic voltammetry (CV) behavior of PMXL displayed an anodic peak in the forward scan, indicating that PMXL underwent electrooxidation, and an enhanced detection peak with lower detection potential was achieved for gCN-modified carbon paste electrode (gCN·CPE). The influence of different parameters on the electrochemical behavior was analyzed, revealing the diffusion governing the electrode process with an equal number of hydronium ions and electron involvement. For the fabricated gCN·CPE, good linearity range was noticed from 0.05 to 500 µM, and a lower detection limit (L D ) of 0.012 µM was achieved for the selected concentration range (0.5 to 30 µM). Selectivity of the electrode in PMXL detection was investigated by conducting an interference study, while the tablet sample analysis demonstrates the sensitive and real-time application of the electrode. The good recovery values for the analysis illustrate the efficiency of the electrode for PMXL analysis.

36 MATERIALS SCIENCE↗

Ion mobility spectrometry of hydrazine, monomethylhydrazine, and ammonia in air with 5-nonanone reagent gas

Hydrazine (HZ) and monomethylhydrazine (MMH) in air were monitored continuously using a hand-held ion mobility spectrometer equipped with membrane inlet, 63Ni ion source, acetone reagent gas, and ambient temperature drift tube. Response characteristics included detection limit, 6 ppb; linear range, 10-600 ppb; saturated response, >2 ppm; and stable response after 15-30 min. Ammonia interfered in hydrazines detection through a product ion with the same drift time as that for MMH and HZ. Acetone reagent gas was replaced with 5-nonanone to alter drift times of product ions and separate ammonia from MMH and HZ. Patterns in mobility spectra, ion identifications from mass spectra, and fragmentation cross-sections from collisional-induced dissociations suggest that drift times are governed by ion-cluster equilibria in the drift region of the mobility spectrometer. Practical aspects including calibration, stability, and reproducibility are reported from the use of a hand-held mobility spectrometer on the space shuttle Atlantis during mission STS-37.

Flight Experiment↗

Label-free nanoscopy of cell metabolism by ultrasensitive reweighted visible stimulated Raman scattering

Nanoscopic imaging of cell metabolism is hindered by the incompatibility of small metabolites with fluorescent dyes and the limited resolution of imaging mass spectrometry. We present ultrasensitive reweighted visible stimulated Raman scattering (URV-SRS), a label-free vibrational nanoscopy technique that enables multiplexed detection of metabolic nanostructures within cells. We developed an extensively chirped spectral focusing visible SRS microscope that achieves a detection limit of 4,000 molecules and introduced a self-supervised learning-based denoiser to robustly suppress non-independent SRS noise by over 7.2 dB. The instrumentation-based signal enhancement and computation-based noise suppression synergistically improved the detection sensitivity by 50 times over near-infrared SRS. Leveraging this enhanced sensitivity, we further pushed the resolution to nanoscopic levels by introducing Fourier reweighting to amplify sub-100 nm spatial frequencies previously overwhelmed by noise. Validated by Fourier ring correlation, URV-SRS achieves a lateral resolution of 86 nm in cellular imaging. Here, we applied URV-SRS to elucidate the reprogramming of metabolic nanostructures associated with virus replication in Vero E6 host cells and to compositionally delineate subcellular fatty acid synthesis in engineered Escherichia coli, demonstrating its capability towards nanoscopic spatial metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Counting Particles Emitted by Stratospheric Aircraft and Measuring Size of Particles Emitted by Stratospheric Aircraft

There were two principal objectives of the cooperative agreement between NASA and the University of Denver. The first goal was to modify the design of the ER-2 condensation nuclei counter (CNC) so that the effective lower detection limit would be improved at high altitudes. This improvement was sought because, in the instrument used prior to 1993, diffusion losses prevented the smallest detectable particles from reaching the detection volume of the instrument during operation at low pressure. Therefore, in spite of the sensor's ability to detect particles as small as 0.008 microns in diameter, many of these particles were lost in transport to the sensing region and were not counted. Most of the particles emitted by aircraft are smaller than 0.1 micron in diameter. At the start date of this work, May 1990, continuous sizing techniques available on the ER-2 were only capable of detecting particles larger than 0.17 micron. Thus, the second objective of this work was to evaluate candidate sizing techniques in an effort to gain additional information concerning the size of particles emitted by aircraft.

Wilson, James Charles↗