A new tubular ironless linear induction motor using non-interrupted winding method

The ironless linear induction motor device can be used for any application which requires a large motion span or rotation restrictedly by the ironless feature due to the strong magnetic field environment. One of the possible applications is ITER diagnostics shutters. The tokamak reactor systems have a severe radiation issue during the operation. The traditional Kapton-insulated wires have significantly lower radiation resistance than an expected large radiation dose at ITER Motion Stark Effect (MSE) shutter location. Furthermore, the traditional single-sided linear induction motor winds the wire to make the N-turn pitch coils independently and then connect them in series to make a one-phase winding. Therefore, it is a big challenge to make so many radiation-protection connectors in such a limited space as inside the vacuum vessel of fusion reactors. The approved mineral-insulated kinds of cables need a large bend radius for the end turns, so the traditional single-sided linear motor with two-layer three-phase windings need to be upgraded to the tubular linear motors. The new proposed tubular ironless linear induction motor can not only overcome the large bend radius issue with the mineral-insulated cables but also allow the motor coils wound continuously around the tubular-shaped stator, forward and backward N times to make a N-turn winding for each phase, in order to resolve the radiation protection issue with the winding connection. The 3D transient Maxwell electromagnetic model with a tubular three-phase linear induction motor has been analyzed. Furthermore, this paper will present the detailed design and winding method of ironless linear induction motor actuators, and results of the 3D transient numerical simulation of the actuator performance.

Ironless↗

Automated Fluidics Device for Extraction and Quantification of miRNA Biomarkers From Blood

Radiation Assessment DuRing Exposure And long-Duration Spaceflight (RADREADS) demonstrates space-compatible point-of-care technology for quantitative biological monitoring of blood miRNA biomarkers in response to long-term low dose radiation exposure. This individualized monitoring approach will inform targeted treatment strategies to maximize medical resource utilization by accounting for individual susceptibility to radiation-related illnesses. As human spaceflight progresses beyond Earth’s magnetic shielding, radiation exposure poses a significant risk to astronaut health and safety. Extended operation in this environment comes with an increased risk of radiation exposure, leading to higher risks of radiation sickness, cancer, central nervous system effects, and degenerative diseases. While conventional physical dosimetry techniques capture radiation dose, individualistic susceptibility to radiation damage is varied. Multiple characteristics, including age, body weight, sex, genetics, and immune status, have been found to influence radiosensitivity (Liu et al. 2011, and Bouffler 2016). This differential response necessitates individualized monitoring and targeted treatment strategies to maximize medical resource utilization; however, a practical diagnostic platform for quantifying long-term, low dose radiation-induced tissue damage does not currently exist. MicroRNAs (miRNAs) are a class of small, non-coding RNAs that regulate gene expression by mediating the degradation of messenger RNA. The levels of particular miRNAs are influenced by biological processes such as inflammation and serve as biomarkers for a variety of conditions including cancer (Singh et al. 2017). MicroRNAs are found in various bodily fluids and are amenable to collection via liquid biopsies, providing a minimally invasive and easily quantifiable readout for a variety of radiosensitive reporters. A preliminary signature of 15 spaceflight sensitive miRNA has been identified in rodent and human studies, including miR-21-5p, miR-24-3p, miR-92a-3p, miR-17-5p, miR-16a-3p, miR-34a-3p, and miR-223-3p. These targets generally increased expression with radiation dose and linear energy transfer, though variation between individuals is not yet described. Current gaps in the field include a lack of understanding of longitudinal biological responses to long-term, low dose radiation exposure and the absence of space-compatible point-of-care technology for quantitative biological monitoring. In this body of work, we aim to develop an automated bleed-to-read system to process whole blood for the detection of miRNA biomarkers in order to monitor individualistic responses to radiation exposure. This will be achieved via separating serum (or plasma) from whole blood, followed by extraction, amplification, and quantification of the miRNA using a RT-qPCR reaction. Previously, the WetLab-2 hardware enabled execution of a RT-qPCR reaction aboard ISS; however, it is a manual system that requires crew manipulation and bulky components (Parra et al. 2017). To address these issues, automated fluid handling hardware was developed for each stage of sample preparation. Extraction of total RNA is achieved by sequentially pumping reagents through an off-the-shelf nucleic acid binding column (miRNeasy Serum/Plasma Advanced Kit, Qiagen). This approach eliminates several manual pipetting and centrifuging steps and limits the use of toxic chemicals commonly found in other sample processing techniques. The resulting elution will then be automatically dispensed for RT-qPCR analysis using a compact rotary qPCR (Mic qPCR Cycler, Bio Molecular Systems) that will improve spaceflight compatibility by removing bubbles from the detection region, another challenge highlighted by WetLab-2 (Parra et al. 2017). Efforts are also being made to simplify the RT-qPCR reaction to a 1-step air-dryable mix to improve long-term reagent stability at room temperature and reduce system complexity. By automating the RT-qPCR processes via microfluidic manipulation, RADREADS will reduce crewmember hands-on time and enable the personalized detection of radiation-induced tissue damage during long duration missions. Minimally invasive, longitudinal monitoring of individual’s response to radiation exposure will inform how the physiological system responds to long-term low dose space radiation and enables development of targeted countermeasures by the medical team. Ultimately, this portable technology will require minimal technical expertise and can also be used to monitor miRNA biomarkers associated with other diseases.

Tristen Head↗

Linear simulation of magnetohydrodynamic plasma response to three-dimensional magnetic perturbations in high-β P plasmas

In this work, we report the numerical analyses of linear magnetohydrodynamics (MHD) plasma response to applied three-dimensional magnetic perturbations (MPs) in a joint DIII-D/EAST collaboration on high-β P (poloidal beta) plasmas, utilizing the extended-MHD code M3D-C1, with the purpose of realizing a better understanding of the existing experiment in which the n=3 MPs were applied to such high-β P plasmas attempting to control large amplitude type-I ELMs. Such high-β P plasmas obtained at the DIII-D tokamak feature an upper-biased double null configuration, a high edge safety factor q 95 ~6.4, and a stable internal transport barrier (ITB) leading to relatively high core pressures. Single-fluid simulations show that the plasma response to n=3 MPs, including both non-resonant/kinking and resonant components, is significantly weaker than that to n=1 or 2 MPs. To survey the impact of q 95 on plasma response to applied MPs, the SEGWAY (Self-consistent Equilibrium Generating Workflow for AnalYsis) module, developed in the OMFIT integrated modelling framework, is employed to generate a series of equilibria with a wide range of q 95 while other key parameters including the normalized beta, electron density at pedestal top, and plasma shape are kept fixed. Compared to the vacuum response, single-fluid M3D-C1 simulations predict a much more significant decrease of resonant plasma response to the applied n=3 MPs at the maximum penetration radii as q 95 increases. In contrast to single-fluid simulation results showing resonant penetration occurs only near the pedestal top where the E×B toroidal rotation frequency is zero, two-fluid simulations show two comparable resonant penetrations locating near the pedestal top and the ITB foot, where the perpendicular electron rotation frequency is zero. Such resonant field penetration near the ITB foot may be responsible for the observed formation of a staircase structure in both electron density and temperature profiles and thereby a considerable deterioration of global plasma performance when MPs are applied in high-β P plasmas. Motivated by this numerical work, we provide some ideas for the future research, with the purpose of realizing effective ELM control in such high-β P plasmas on the DIII-D and EAST devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Edge-localized-mode simulation in CFETR steady-state scenario

We report the EPED1 model and self-consistent core-pedestal coupling in integrated modeling are used to design the pedestal structure of the China Fusion Engineering Testing Reactor (CFETR) steady-state scenario. The key parameters, such as β p and q 95 , are based on the grassy edge-localized-mode (ELM) experimental database. In this work, we use the BOUT++ six-field two-fluid code to simulate the onset of the ELM in the CFETR steady-state scenario. The ELM size is around 0.2% in nonlinear simulations, which is in the experimental range of the grassy ELM discharges, 0.1%–1% observed in multiple tokamak devices. Linear and nonlinear simulations show that the dominant high-n ballooning modes peak around n = 40. Compared to type-I ELM crashing dynamics, grassy ELM crashing has a smaller initial crash and is then followed by three phases of turbulence spreading, which are dominated by multi-modes, a high-n mode of n = 45 and low-n mode of n = 5, respectively. In contras to type-I ELM, the perturbation of the high-n mode has a narrow width around ψ = 0.95, and magnetic island formation and reconnection occur only beyond ψ = 0.95, leading to a small initial crash. Mode–mode interaction in the multi-mode coexistence stage stops the growth of individual modes and reduces the transport of particles and heat, and these are the two reasons why the ELM size is small. In–out asymmetry of transient heat flux with a ratio of E out /E in = 3.5 is found during grassy ELM crash. The rise and delay times of the heat flux match the calculation from the free-streaming model. To evaluate the erosion of the divertor target, the energy fluence at the outer divertor target is calculated, which is 0.029 MJ m -2 , 5.5 times smaller than the tungsten melting limit 0.16 MJ m -2 . The calculated energy fluency still follows the experimental scaling law from type-I ELM experiments. The fluctuation eddies in the toroidal direction show a filament structure at the outer mid-plane. Parallel heat flux patterns with a toroidal mode number n = 10 are found at the outer divertor with an amplitude of 680 MW m -2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗