Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Pantechnik new superconducting ion source: PantechniK Indian Superconducting Ion Source

The new ECR ion source PantechniK Indian Superconducting Ion Source (PKISIS) was recently commissioned at Pantechnik. Three superconducting coils generate the axial magnetic field configuration, while the radial magnetic field is done with the multi-layer permanent magnets. Special care was devoted to the design of the hexapolar structure, allowing a maximum magnetic field of 1.32 T at the wall of the 82 mm diameter plasma chamber. The three superconducting coils using low temperature superconducting wires are cooled by a single double stage cryo-cooler (4.2 K). Cryogen-free technology is used, providing reliability and easy maintenance at low cost. The maximum installed RF power (18.0 GHz) is of 2 kW. Metallic beams can be produced with an oven (T{sub max}= 1400 deg. C) installed with an angle of 5 deg. with respect to the source axis or a sputtering system, mounted on the axis of the source. The beam extraction system is constituted of three electrodes in accel-decel configuration. The new source of Pantechnik is conceived for reaching optimum performances at 18 GHz RF frequencies. PKISIS magnetic fields are 2.1 T axial B{sub inj} and 1.32 T radial field in the wall, variable B{sub min} with an independent coil and a large and opened extraction region. Moreover, PKISIS integrates modern design concepts, like RF direct injection (2 kW availability), dc-bias moving disk, out-of-axis oven and axial sputtering facility for metal beams. Finally, PKISIS is also conceived in order to operate in a high-voltage platform with minor power consumption.

43 PARTICLE ACCELERATORS↗

Development of a Process to Build Polyimide Insulated Magnets For Operation at 350C

An extensive R&D program has been conducted that has confirmed the feasibility of designing and fabricating copper alloy magnets that can successfully operate at temperatures as high as 350C. The process, originally developed for the possibility of manufacturing in-vessel resonant magnetic field perturbation (RMP) coils for JET, has been optimized for insulated magnet (and, potentially, other high temperature component) applications. One of the benefits of high temperature operation is that active cooling may no longer be required, greatly simplifying magnet/component design. These elevated temperatures are beyond the safe operating limits of conventional OFHC copper and the epoxies that bond and insulate the turns of typical magnets. This would necessitate the use an alternative copper alloy conductor such as C18150 (CuCrZr). Coil manufacture with polyimide is very similar to conventional epoxy bonded coils. Conductors would be dry wound then impregnated with polyimide of low enough viscosity to permit saturation, then cured; similar to the vacuum pressure impregnation process used for conventional epoxy bonded coils. Representative polyimide insulated coils were mechanically tested at both room temperature and 350C. Mechanical tests included turn-to-turn shear bond strength and overall polyimide adhesion strength, as well as the flexural strength of a 48-turn polyimide-bonded coil bundle. This paper will detail the results of the testing program on coil samples. These results demonstrate mechanical properties as good, or better than epoxy bonded magnets, even at 350C.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reduced electron temperature in a magnetized inductively-coupled plasma with internal coil

The effect of magnetic filtering on the electron energy distribution function is studied in an inductive discharge with internal coil coupling. The coil is placed inside the plasma and driven by a low-frequency power supply (5.8 MHz) which leads to a very high power transfer efficiency. A permanent dipole magnet may be placed inside the internal coil to produce a static magnetic field around 100 Gauss. The coil and the matching system are designed to minimize the capacitive coupling to the plasma. Capacitive coupling is quantified by measuring the radiofrequency (rf) plasma potential with a capacitive probe. Without the permanent magnet, the rf plasma potential is significantly smaller than the electron temperature. When the magnet is present, the rf plasma potential increases. The electron energy distribution function is measured as a function of space with and without the permanent magnet. When the magnet is present, electrons are cooled down to low temperature in the downstream region. This region of low electron temperature may be useful for plasma processing applications, as well as for efficient negative ion production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design, construction, and testing of no-insulation small subscale solenoids for compact tokamaks

Fusion energy systems studies (FESS) for next-step devices based on the most promising magnetic configurations indicate that high magnetic fields and high current density for magnet coil systems may reduce device size and lower the cost. High current density and radiation resistant fusion magnets are particularly beneficial for low cost, low aspect ratio compact reactor designs such as Fusion Nuclear Science Facility (FNSF), Fusion Pilot Plant (FPP) of low-aspect ratio spherical tokamak (ST) or compact stellarators. Unlike typical high field magnets for nuclear magnetic resonance (NMR), magnetic resonance imaging (MRI), or high energy physics research applications, neutron irradiation damage to organic insulations in the coil winding pack is a critical issue for next generation fusion reactors where orders of magnitude higher neutron fluence than those in present experimental reactors such as ITER are expected. Moreover, a high coil winding pack current density is needed for high field magnets in low cost, compact radial build next step fusion reactors. The slow current charging time, however, is an issue in fully non-insulated coils. In this work, we present the design, construction and testing of subscale Nb3Sn solenoids, up to half the diameter of the central solenoid (CS) for National Spherical Torus Experiment (NSTX), with and without inter-layer insulation for enhancing radiation resistance while improving the winding pack current density and coil performance. The major radius for the NSTX/NSTX-Upgrade (reference for compact ST) is 0.854/0.934 meter, and 4.8 meters for FNSF. The magnetic field for NSTX/NSTX-U at the plasma center is 0.6/1 Tesla and 9 Tesla for FNSF. The inner diameter of the central solenoid coil is 0.2/0.4 meter for NSTX/NSTX-U and 1.2 meters for FNSF. The current charging and discharging behavior of the prototype solenoids was investigated to quantify performance advantages of a simplified coil fabrication without error-prone vacuum pressure impregnation (VPI) for the removal of epoxy organic insulation. Scalability of the no insulation concept for fusion can be addressed via engineered coating for novel insulation on contact resistance or intra-layer no insulations. Radiation resistance and coil winding efficiency were significantly improved in the no insulation coils for next step compact fusion reactors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SQUIDs vs. Faraday coils for ultlra-low field nuclear magnetic resonance: experimental and simulation comparison

Nuclear magnetic resonance (NMR) methods are widely used in medicine, chemistry and industry. One application area is magnetic resonance imaging or MRI. Recently it has become possible to perform NMR and MRI in ultra-low field (ULF) regime that requires measurement field strengths only of the order of 1 Gauss. These techniques exploit the advantages offered by superconducting quantum interference devices or SQUIDs. Our group at LANL has built SQUID based MRI systems for brain imaging and for liquid explosives detection at airports security checkpoints. The requirement for liquid helium cooling limits potential applications of ULF MRI for liquid identification and security purposes. Our experimental comparative investigation shows that room temperature inductive magnetometers provide enough sensitivity in the 3-10 kHz range and can be used for fast liquid explosives detection based on ULF NMR/MRI technique. We describe an experimental and computer simulation comparison of the world's first multichannel SQUID based and Faraday coils based instruments that are capable of performing ULF MRI for liquids identification.

42 ENGINEERING↗

Makeup and uses of a basic magnet laboratory for characterizing high-temperature permanent magnets

A set of instrumentation for making basic magnetic measurements was assembled in order to characterize high intrinsic coercivity, rare earth permanent magnets with respect to short term demagnetization resistance and long term aging at temperatures up to 300 C. The major specialized components of this set consist of a 13 T peak field, capacitor discharge pulse magnetizer; a 10 in. pole size, variable gap electromagnet; a temperature controlled oven equipped with iron cobalt pole piece extensions and a removable paddle that carries the magnetization and field sensing coils; associated electronic integrators; and sensor standards for field intensity H and magnetic moment M calibration. A 1 cm cubic magnet sample, carried by the paddle, fits snugly between the pole piece extensions within the electrically heated aluminum oven, where fields up to 3.2 T can be applied by the electromagnet at temperatures up to 300 C. A sample set of demagnetization data for the high energy Sm2Co17 type of magnet is given for temperatures up to 300 C. These data are reduced to the temperature dependence of the M-H knee field and of the field for a given magnetic induction swing, and they are interpreted to show the limits of safe operation.

Niedra, Janis M.↗

REBCO Insert Coils toward High-Field, Large-Bore Magnet for Quantum Physics Research

High-temperature superconducting (HTS) magnets offer a promising solution for generating high magnetic fields efficiently and economically, serving as a vital component in nextgeneration scientific instruments and carbon-neutral power systems, notably in cost-effective compact fusion reactors. These high magnetic fields play a pivotal role in advancing research on quantum materials, particularly in elucidating the intricate electronic states near magnetic phase transitions. Here, this paper delves into the research conducted at the Princeton Plasma Physics Laboratory, which is divided into three phases aimed at overcoming technical hurdles in creating large-bore, high-field HTS magnets for cutting-edge quantum physics research. In Phase 1, we designed, constructed, and tested a compact REBCO solenoidal magnet comprising six double-pancake coils featuring a 41.3-mm inner diameter and a 70.0-mm outer diameter. It adopts a no-insulation approach to ensure electrical and thermal stability. Successful testing in a saturated liquid nitrogen bath confirmed its capability to generate a 0.8-T field at 77 K and 2 T at 65 K, with ongoing integration into liquid helium testing. Building on this experience, Phase 2 involves the design of an HTS insert coil, intended to nest within a 12-T low-temperature superconducting (LTS) outsert to achieve a minimum of 20 T at 4.2 K. The focus of Phase 2 centers on addressing challenges posed by screening-current (SC) effects, particularly the associated stress/strain issues. Employing a numerical model that fully couples the SC and mechanical analysis, we discuss strategies for managing stress to mitigate the effects of SCinduced stress concentrations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bucking Coil Implementation on PMT for Active Cancelling of Magnetic Field

Aerogel and water Cerenkov detectors were employed to tag kaons for a lambda hypernuclear spectroscopic experiment which used the (e,e'K{sup +}) reaction in experimental Hall C at Jefferson Lab (JLab E05-115). Fringe fields from the kaon spectrometer magnet yielded ~5 Gauss at the photomultiplier tubes (PMT) for these detectors which could not be easily shielded. As this field results in a lowered kaon detection efficiency, we implemented a bucking coil on each photomultiplier tubes to actively cancel this magnetic field, thus maximizing kaon detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An improved theory of the response of DIII-D H-mode discharges to static resonant magnetic perturbations and its implications for the suppression of edge localized modes

The plasma response to an externally generated, static, n = 2, resonant magnetic perturbation (RMP) in the pedestal region of DIII-D H-mode discharge #158115 is investigated using a toroidal generalization of the asymptotic matching model presented by Fitzpatrick [Phys. Plasmas 27, 042506 (2020)]. Just as in a recent paper [Q. M. Hu et al., Phys. Plasmas 26, 120702 (2019)], it is hypothesized that the density pump-out phenomenon is due to locked magnetic island chains induced at the bottom of the pedestal, whereas the suppression of edge localized modes is associated with a locked magnetic island chain induced at the top of the pedestal. Neutral penetration inside the last closed magnetic flux-surface is found to have a significant influence on locked magnetic island chain formation at the bottom of the pedestal. It is found that locked island formation at the top of the pedestal is only possible when q95 lies in certain narrow windows. Finally, it is inferred that, in order to successfully induce a locked island chain at the top of the pedestal, an external RMP field-coil system must generate a magnetic field that is simultaneously strongly amplified by the plasma (via the ideal kink response) and has a large resonant component at a rational surface that lies close to the top of the pedestal.

Fitzpatrick, R. (ORCID:0000000162379309)↗

Hall B superconducting magnets for the CLAS12 detector at JLAB

Hadron physics has been an essential part of the physics program with the CLAS detector in experimental hall B at Thomas Jefferson National Accelerator Facility (Jefferson Lab). With the 12 GeV upgrade of the CEBAF machine, hadron physics in Hall B will be extended to a new domain of higher mass resonances and the range of higher transferred momentum using up to 11 GeV electron beams and the upgraded CLAS12 detector. In this paper, status of the hall B superconducting magnets for the 12 GeV upgrade is presented.

43 PARTICLE ACCELERATORS↗

Broadband Active Antenna

Effective area of search coil increased. Input impedance presented by operational amplifier and associated components nearly balances out impedance of search coil. Fluctuations in ambient magnetic field induce large currents in search coil.

Sutton, John F.↗

Study of laser-driven magnetic fields with a continuous wave Faraday rotation diagnostic

Magnetic fields driven by a laser in coil targets were studied for laser energies of ~25 J and two pulse durations of 2.8 ns and 70 ps. Axial magnetic fields in the coils were measured by continuous wave Faraday rotation diagnostics. The diagnostics indicated magnetic fields of 6–14 T in the coil and currents of 10–20 kA. Magnetic fields were compared for similar laser targets, focusing conditions, and laser energies. A 30-times increase in the intensity of the laser beam by reducing the pulse duration resulted in an increase in the magnetic field and current by a factor of 2. The relaxation time of the magnetic pulse was on the sub-microsecond scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of superconductivity in magnetic bearings for high-load applications

Slewing of large payloads will require control torque and angular momentum storage capacities that are large in comparison to the capabilities of available control moment gyros (CMG's). SatCon Technology Corporation is currently designing a CMG which may be employed as a slew actuator for large spacecraft or other payloads. The slew actuator employs a type of magnetic bearing which may be used in high load applications. The magnetic bearing is also used to fully gimbal the suspended rotor of the slew actuator. The use of magnetic bearings in angular momentum exchange actuators has the primary advantage that physical contact between the rotor and stator is eliminated. This leads to greatly extended life, increased reliability, and reduced vibrations. Several actuators operating on magnetic bearings have been demonstrated in previous research efforts. These were sized for use in small satellites. For conventional magnetic bearings, which employ magnetic cores, high torsional loading may require that the magnetic structure be excessively massive. An alternative magnetic bearing design which employs a superconducting coil and eliminates conventional magnetic structures is discussed. The baseline approach is to replace the field coil of a conventional magnetic bearing with the superconducting coil.

Downer, James↗

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan-II (PIP-II) is a vital upgrade to Fermilab's accelerator complex. The upgrade is designed to power the world s most intense high-energy neutrino beam in future experiments. The magnet pulse repetition rate of the PIP-II injection system is being upgraded from 15 Hz to 20 Hz and requires a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) magnets in the Booster. The magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled single turn coil is electrically isolated from the core using virgin PEEK insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted. The design of the coil which shapes the magnetic field by acting as the pole tips is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The ORBUMP magnet mechanical design is presented in this paper.

Karas, Dino [Fermilab] (ORCID:0000000304340670)↗

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan II (PIP-II) project is a vital upgrade to the Fermilab accelerator complex. The magnet pulse rate of the PIP-II Injection system requires an increase from the current rate of 15 Hz to 20 Hz as well as a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) pulsed dipole magnets in the Booster. Here, the ORBUMP magnet mechanical design is presented in this paper. The ORBUMP magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic magnesium phosphate coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled, single turn coil, which shapes the magnetic field by acting as the pole tips, is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The coil is electrically isolated from the core using virgin Polyether ether ketone (PEEK) insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted via partial discharge testing using a 1:1 scale sample.

Karas, D. [Fermi National Accelerator Laboratory (↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

Fourier Analysis Method for Wireless Power Transfer Coil Design

Wireless power transfer (WPT) systems for Electric Vehicles (EVs) are designed to meet specifications such as stray field, power transfer, efficiency, and ground clearance. Typical design approaches include iterative analysis of predetermined coil geometries to identify candidates that meet these constraints. This work instead directly generates WPT coil shapes and magnetic fields to meet specifications and constraints through the optimization of Fourier basis function coefficients. The proposed Fourier Analysis Method (FAM) applies to arbitrary planar coil geometries and does not rely on iterative finite-element analysis (FEA) simulations. This flexibility allows for rapid design evaluation across a larger range of coil geometries and design specifications. A prototype coil is built to compare FAM outputs to experimental measurements and FEA simulations. The FAM is then used to illustrate the tradeoff of coil current and stray field for a given power level showing that the method is capable of generating optimized coil shapes to meet arbitrary field constraints.

Foote, Andrew↗