Hyperfine spectroscopy using transverse modulated optical pumping

Population inversion is observed between the field-independent ground hyperfine states of Rb-87 when using an optical pumping technique which is applicable to a large number of species of atoms and ions. Inversion occurs upon a coherent transfer of angular momentum to the Rb-87 spin system from circularly polarized light propagating in a transverse direction to a magnetic field. Coherence is established by modulating, at certain frequencies, the light intensity or magnetic-field strength.

Hughes, W. M.↗

Bessel Tube to Capture Lunar Volatiles

Current arts to create linear motion or acceleration of fine particles and molecules into devices such as mass spectrometers and vacuum pumps rely on the pressure difference created by a pinhole or mechanical processes. However, in an environment of vacuum, these approaches do not create such a pressure differential to drive and move fine particles and molecules. In some cases, electrostatic or magnetic processes may work to create the desired motion. A cylindrical harmonic of electric field, which is widely used in electron accelerators, offers a unique capability to capture and induce a linear motion of molecules and particles when electrically charged. Generally, lunar volatiles are electrostatically charged. The idea to capture and collect the lunar volatiles by creating a drift axis of motion using a cylindrical harmonic field has led to the development of a device concept, called a Bessel Tube. The Bessel Tube concept ingests fine particles, gaseous atoms, and gaseous molecules and guides them along an extraction tube for collection, separation, and analysis. The Bessel Tube concept for lunar volatile collection is discussed.

Bessel Tube↗

Complete the development and construction of a spaceborne hydrogen maser clock

The objective, to complete the development of an engineering model of a spaceborne hydrogen maser, was successfully achieved. A layout of the maser and detail drawings of the physics package was completed during the first 7 months of the contract. A computer model was made for the maser's thermal design. Using numerical computations, heater resistances were established for 7 temperature controlled zones. The physics package includes: a vacuum manifold that houses four sorption pumps capable of scavenging hydrogen for 4 years, a titanium vacuum tank housing the cavity, metallic seals for all vacuum joints, an RF dissociator within the vacuum envelope, a two-layer printed circuit solenoid and four layers of moly-permalloy magnetic shields. Problems were encountered and overcome in the procurements of the PC solenoid and the magnetic shields. After completion of the fabrication of the maser's components, the maser was assembled using these parts and other components made available by SAO, NRL, and NASA from earlier development work. In March, 1990, the vacuum system was assembled, and by May the maser assembly was completed. The magnetic shielding was poor and the shields were removed, reannealed by a local vendor, and the maser was reassembled. The maser began tests in early June and has been oscillating since that time. The test results of the maser are very good and a life test of the maser is being conducted. It is anticipated that the development and construction of a maser to be tested in space under a new contract from NASA's Marshall Space Flight Center will continue.

Vessot, Robert F. C.↗

Thermal Design, Analysis, and Testing of a Conductively-Cooled, High Temperature Superconducting Rotor for a 1.4 MW Electric Machine for Aeronautics Applications

This presentation covers the second ever demonstration of a superconducting rotor cooled only via conductive connection to a cryocooler, i.e., without pumped or solid cryogens. The full-scale rotor was operated statically in its intended environment – about 1e-3 torr vacuum with only conductive cooling through mechanical connections to a cryocooler contained on the rotor. Stable operation of the rotor in a representative magnetic environment was demonstrated up to its rated direct current (57.2 A) and the designed temperature limit for the superconductor (62 K). In all but one case, the observed temperature gradient between the cold tip and superconducting coils satisfies the design but with little margin. Thermal modeling and correlation with test data is presented identifying the areas of largest discrepancy. Opportunities to reduce the temperature gradient are identified.

electrified aircraft propulsion↗

Actively Pumped Optical Filters at 532 nm

The operation of two narrow-band optical filters at 532.33 nm is presented. Both of these filters operate on the 4P(sub 1/2) to 8S(sub 1/2) excited-state transition in potassium vapor. One of the filters is based on excited-state Faraday effect, and requires the application of an external axial magnetic field. The peak transmission of this filter is approximately 3.5% with a linewidth of less than 10 GHz. The second filter does not require a magnetic field for its operation, but readily attains peak transmissions of 25-30%. The 4P(sub 1/2) state is excited by a 769.9 nm light pulse which is linearly polarized for the first scheme and circularly polarized for the second.

Billmers, Richard I.↗

Composition and structure of the Venus atmosphere - Results from Pioneer Venus

The composition of the Venusian atmosphere was studied using a mass spectrometer on the Pioneer Venus sounder probe. The single-focusing magnetic-sector spectrometer scanned the mass range from hydrogen through mercury with a dynamic range of six decades. Data taken by the mass spectrometer were compared with those of a gas chromatograph, resulting in slight discrepancies due to the use of a sputter ion pump acting as a sink for entry of rare gases through the inlet leak. A surprisingly large concentration of primordial Ar-36 and Ar-38 was discovered in a ratio of 5 to 1. It was concluded that the large excess of primordial argon was a valid result and that the mixing of HCl in the lower Venusian atmosphere was less than a few parts per million. Arguments against the sun as the source for excess primordial gases on Venus were presented. Concentrations of other elements such as Ne, Kr, He, S, and O were discussed. Although the mass peaks in the spectrum were real, it was not clear whether all of the chemical reactions (i.e., COS production) actually occurred in the atmosphere. Until further analysis can be made, it will be uncertain how the inlet system, which is at atmospheric temperature, affected the results.

Hoffman, J. H.↗

Pioneer Venus large probe neutral mass spectrometer

The Pioneer Venus large probe neutral mass spectrometer (LNMS) uses a single focusing magnetic sector field mass analyzer with mass range of 1-208 amu, resolution sufficient to separate the mercury isotopes, and sensitivity sufficient to detect minor constituents in the 1 ppm range relative to the CO2 in the Venus atmosphere. A combination of ion and chemical pumping is used to maintain a vacuum in the mass analyzer and to remove the atmosphere gases which enter the ion source chamber through a special leak. A microprocessor controls the operation of the instrument through a highly efficient peak stepping and data compression program, permitting acquisition of a complete mass spectrum roughly once each minute.

Hoffman, J. H.↗

NASA Lewis Research Center combustion MHD experiment

The MHD power generation experiments were conducted in a high field strength cryomagnet which was adapted from an existing facility. In its original construction, it consisted of 12 high purity aluminum coils pool cooled in a bath of liquid neon. In this configuration, a peak field of 15 tesla was produced. For the present experiments, the center four coils were removed and a 23 cm diameter transverse warm bore tube was inserted to allow the placement of the MHD experiment between the remaining eight coils. In this configuration, a peak field of 6 tesla should be obtainable. The time duration of the experiment is limited by the neon supply which allows on the order of 1 minute of total operating time followed by an 18-hour reliquefaction period. As a result, the experiments are run in a pulsed mode. The run duration for the data presented here was 5 sec. The magnetic field profile along the MHD duct is shown. Since the working fluid is in essence superheated steam, it is easily water quenched at the exit of the diffuser and the components are designed vacuum tight so that the exhaust pipe and demister an be pumped down to simulate the vacuum of outer space.

Smith, J. M.↗

Gas-liquid Phase Distribution and Void Fraction Measurements Using the MRI

We used a permanent-magnet MRI system to estimate the integral and spatially- and/or temporally-resolved void-fraction distributions and flow patterns in gas-liquid two-phase flows. Air was introduced at the bottom of the stagnant liquid column using an accurate and programmable syringe pump. Air flow rates were varied between 1 and 200 ml/min. The cylindrical non-conducting test tube in which two-phase flow was measured was placed in a 2.67 kGauss MRI with MRT spectrometer/imager. Roughly linear relationship has been obtained for the integral void-fraction, obtained by volume-averaging of the spatially-resolved signals, and the air flow rate in upward direction. The time-averaged spatially-resolved void fraction has also been obtained for the quasi-steady flow of air in a stagnant liquid column. No great accuracy is claimed as this was an exploratory proof-of-concept type of experiment. Preliminary results show that MRI a non-invasive and non-intrusive experimental technique can indeed provide a wealth of different qualitative and quantitative data and is especially well suited for averaged transport processes in adiabatic and diabatic multi-phase and/or multi-component flows.

Daidzic, N. E.↗

Filamentation instability of large-amplitude Alfven waves

An instability that leads to the filamentation of large-amplitude Alfven waves and gives rise to purely growing density and magnetic field fluctuations is studied. The dispersion relation of the instability is derived, from which the threshold conditions and the growth rates of the instability are analyzed quantitatively for applications to the solar wind plasma. Their dependence on the filamentation spectrum, the plasma beta, and the pump frequency and intensity was examined for both right-hand and left-hand circularly polarized Alfven waves. The excitation of filamentation instability for certain cases of interest is discussed and compared with that of the parametric decay and modulation instability. The relevance of the proposed instability to some observations is discussed.

Kuo, S. P.↗

Performance of the new Efratom optically pumped rubidium frequency standards and their possible application in space relativity experiments

The characteristics of Efratom optically pumped rubidium frequency standards are discussed. The Efratom units were compared with cesium beam and hydrogen maser standards and showed a stability of approximately 5 times 10 to the minus 12th power over two one-week periods. Dependency of frequency upon the environmental parameters of pressure, magnetic field, temperature, supply voltage, and acceleration was measured. A package of three units with automatic phase comparison and recording was designed and constructed to allow a measurement of relativistic effects on time with high accuracy during space missions.

Alley, C. O.↗

Parametric study of ion heating in a burnout device (HIP-1)

Results of further studies on the Lewis Research Center hot-ion plasma source (HIP-1) are reported. Changes have been made in both the electrode geometry and materials to produce higher ion temperatures. Ion temperature increased significantly with increased vacuum pumping speed. The best ion temperatures achieved, so far, for H(+), D(+), and He(+) plasmas are estimated to be equal to, or greater than 0.6, equal to, or greater than 0.9, and equal to, greater than 2.0 keV, respectively. Electrode pairs produced high ion temperatures whether on the magnetic axis or off it by 5.5 cm. Multiple sources, one on-axis and one off-axis, were run simultaneously from a single power supply by using independent gas feed rates. A momentum analyzer has been added to the charge-exchange neutral particle analyzer to identify particles according to mass, as well as energy. Under any given plasma condition, the higher mass ions have higher average energies but not by as much as the ratio of their respective masses.

Sigman, D. R.↗

An integrated development facility for the calibration of low-energy charged particle flight instrumentation

A system was developed for the calibration and development of thermal ion instrumentation. The system provides an extended beam with usable current rates, approx. 1 pA/sq cm, at beam energies as low as 1 eV, with much higher values available with increasing energy. A tandem electrostatic and variable geometry magnetic mirror configuration within the ion source optimizes the use of the ionizing electrons. The system is integrated under microcomputer control to allow automatic control and monitoring of the beam energy and composition and the mass and angle-dependent response of the instrument under test. The system is pumped by a combination of carbon vane and cryogenic sorption roughing pumps and ion and liquid helium operating pumps.

Biddle, A. P.↗

Development of a high power microwave thruster, with a magnetic nozzle, for space applications

This paper describes the current development of a high-power microwave electrothermal thruster (MET) concept at the NASA Lewis Research Center. Such a thruster would be employed in space for applications such as orbit raining, orbit maneuvering, station change, and possibly trans-lunar or trans-planetary propulsion of spacecraft. The MET concept employs low frequency continuous wave (CW) microwave power to create and continuously pump energy into a flowing propellant gas at relative high pressure via a plasma discharge. The propellant is heated to very high bulk temperatures while passing through the plasma discharge region and then is expanded through a throat-nozzle assembly to produce thrust, as in a conventional rocket engine. Apparatus, which is described, is being assembled at NASA Lewis to test the MET concept to CW power levels of 30 kW at a frequency of 915 MHz. The microwave energy is applied in a resonant cavity applicator and is absorbed by a plasma discharge in the flowing propellant. The ignited plasma acts as a lossy load, and with optimal tuning, energy absorption efficiencies over 95 percent (based on the applied microwave power) are expected. Nitrogen, helium, and hydrogen will be tested as propellants in the MET, at discharge chamber pressures to 10 atm.

Power, John L.↗

Variable-Force Eddy-Current Damper

Variable damping achieved without problems of containing viscous fluids. Eddy-current damping obtained by moving copper or aluminum conductors through magnetic fields. Position of magnet carrier determines amount of field engagement and, therefore, amount of damping. Three advantages of concept: Magnitudes of stiffness and damping continously varied from maximum to zero without bringing rotor or shaft to stop; used in rotating machines not having viscous fluids available such as lubricating oils; produces sizable damping forces in machines that pump liquid hydrogen at - 246 degrees C and liquid oxygen at - 183 degrees C and are compact in size.

Cunningham, R. E.↗

Nonlinear evolution of a large-amplitude circularly polarized Alfven wave: High beta

The nonlinear dynamics following saturation of the parametric instabilities of a monochromatic field-aligned large-amplitude circularly polarized Alfven wave is investigated via direct numerical simulation in the case of high plasma beta and no wave dispersion. The magnetohydrodynamic (MHD) code permits nonlinear couplings in the parallel direction to the ambient magnetic field and one perpendicular direction. Compressibility is included in the form of a polytropic equation of state. Turbulent cascades develop after saturation of two coupled oblique three-wave parametric instabilities; one of which is an oblique filamentationlike instability reported earlier. Remnants of the parametric processes, as well as of the original Alfven pump wave, persist during late nonlinear times. Nearly incompressible MHD features such as spectral anisotropies appear as well.

Ghosh, S.↗

An Overview on Aerospatiale Magnetic Bearing Products for Spacecraft Attitude Control and for Industry

Aerospatiale magnetic bearings are based on the use of permanent magnets and on the control of the rotor around a zero force equilibrium point. The present developments of magnetic bearing wheels for space applications focus on the versatility of a basic design which leads to a family of reaction and momentum wheels with tailored torque and kinetic momentum, leading to competitive mass and cost. The present industrial applications concern kinetic energy accumulators, medical x-ray rotating devices, avionics equipment, cryotechnic compressors and vacuum pumps.

Samuel, Alain↗

Cryogenic systems for the large deployable reflector

There are five technologies which may have application for Large Deployable Reflector (LDR), one passive and four active. In order of maturity, they are passive stored cryogen systems, and mechanical, sorption, magnetic, and pulse-tube refrigerators. In addition, deep space radiators will be required to reject the heat of the active systems, and may be useful as auxiliary coolers for the stored cryogen systems. Hybrid combinations of these technologies may well be more efficient than any one alone, and extensive system studies will be required to determine the best trade-offs. Stored cryogen systems were flown on a number of missions. The systems are capable of meeting the temperature requirements of LDR. The size and weight of stored cryogen systems are proportional to heat load and, as a result, are applicable only if the low-temperature heat load can be kept small. Systems using chemisorption and physical adsorption for compressors and pumps have received considerable attention in the past few years. Systems based on adiabatic demagnetization of paramagnetic salts were used for refrigeration for many years. Pulse-tube refrigerators were recently proposed which show relatively high efficiency for temperatures in the 60 to 80 K range. The instrument heat loads and operating temperatures are critical to the selection and design of the cryogenic system. Every effort should be made to minimize heat loads, raise operating temperatures, and to define these precisely. No one technology is now ready for application to LDR. Substantial development efforts are underway in all of the technologies and should be monitored and advocated. Magnetic and pulse-tube refrigerators have high potential.

Mason, Peter V.↗