Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Effect of resonant magnetic perturbations on microturbulence in DIII-D pedestal

Vacuum resonant magnetic perturbations (RMP) applied to otherwise axisymmetric tokamak plasmas produce in general a combination of non-resonant effects that preserve closed flux surfaces (kink response) and resonant effects that introduce magnetic islands and/or stochasticity (tearing response). The effect of the plasma kink response on the linear stability and nonlinear transport of edge turbulence is studied using the gyrokinetic toroidal code GTC for a DIII-D plasma with applied n = 2 vacuum RMP. GTC simulations use the 3D equilibrium of DIII-D discharge 158103 (Nazikian et al 2015 Phys. Rev. Lett. 114 105002), which is provided by nonlinear ideal MHD VMEC equilibrium solver in order to include the effect of the plasma kink response to the external field but to exclude island formation at rational surfaces. Analysis using the GTC simulation results reveal no increase of growth rates for the electrostatic drift wave instability and for the electromagnetic kinetic-ballooning mode in the presence of the plasma kink response to the RMP. Moreover, nonlinear electrostatic simulations show that the effect of the 3D equilibrium on zonal flow damping is very weak and found to be insufficient to modify turbulent transport in the electrostatic turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low field magnetic resonance imaging

A method and system of magnetic resonance imaging does not need a large homogenous field to truncate a gradient field. Spatial information is encoded into the spin magnetization by allowing the magnetization to evolve in a non-truncated gradient field and inducing a set of 180 degree rotations prior to signal acquisition.

Pines, Alexander↗

Coaxial probe for nuclear magnetic resonance diffusion and relaxation correlation experiments

A coaxial nuclear magnetic resonance (NMR) probe is built to measure diffusion and relaxation properties of liquid samples. In particular, we demonstrate the acquisition of two-dimensional (2D) distribution functions (T{sub 1}-T{sub 2} and diffusion–T{sub 2}), essential for fluids characterization. The compact design holds promise for miniaturization, thus enabling the measurement of molecular diffusion that is inaccessible to conventional micro-NMR setups. Potential applications range from crude oil characterization to biomolecular screening and detections.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ nuclear magnetic resonance microimaging of live biofilms in a microchannel

Nuclear magnetic resonance (NMR) microimaging and spectroscopy was used to interrogate fluids of biological importance (e.g., water, buffer, medium solution) and live biofilms in a microchannel compatible for analyses at ambient pressure and under vacuum. Studies using buffer, growth medium, and actively growing Shewanella oneidensis biofilms were used to demonstrate in situ NMR microimaging measurement capabilities including velocity mapping, diffusion coefficient mapping, relaxometry, localized spectroscopy, and 2D and 3D imaging within a microchannel suitable for different analytical platforms. This technique is promising for diverse applications of correlative imaging using a portable microfluidic platform.

biofilm↗

On the Possibility of Express Recording of Nuclear Magnetic Resonance Spectra of Liquid Media in Weak Fields

The necessity of recording nuclear magnetic resonance (NMR) spectra in weak magnetic fields during the express control of liquid media has been substantiated, and the conditions in which such recording is possible have been determined. A new scheme of a compact NMR spectrometer intended for such measurements has been proposed. The results of experimental investigation of some substances based on the developed technologies are reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pathologic Validation of a Model Based on Diffusion-Weighted Imaging and Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Tumor Delineation in the Prostate Peripheral Zone

Purpose: For focal boost strategies in the prostate, the robustness of magnetic resonance imaging-based tumor delineations needs to be improved. To this end we developed a statistical model that predicts tumor presence on a voxel level (2.5 Multiplication-Sign 2.5 Multiplication-Sign 2.5 mm3) inside the peripheral zone. Furthermore, we show how this model can be used to derive a valuable input for radiotherapy treatment planning. Methods and Materials: The model was created on 87 radiotherapy patients. For the validation of the voxelwise performance of the model, an independent group of 12 prostatectomy patients was used. After model validation, the model was stratified to create three different risk levels for tumor presence: gross tumor volume (GTV), high-risk clinical target volume (CTV), and low-risk CTV. Results: The model gave an area under the receiver operating characteristic curve of 0.70 for the prediction of tumor presence in the prostatectomy group. When the registration error between magnetic resonance images and pathologic delineation was taken into account, the area under the curve further improved to 0.89. We propose that model outcome values with a high positive predictive value can be used to define the GTV. Model outcome values with a high negative predictive value can be used to define low-risk CTV regions. The intermediate outcome values can be used to define a high-risk CTV. Conclusions: We developed a logistic regression with a high diagnostic performance for voxelwise prediction of tumor presence. The model output can be used to define different risk levels for tumor presence, which in turn could serve as an input for dose planning. In this way the robustness of tumor delineations for focal boost therapy can be greatly improved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydration kinetics of cements by Time-Domain Nuclear Magnetic Resonance: Application to Portland-cement-derived endodontic pastes

Time-Domain Nuclear Magnetic Resonance (TD-NMR) of {sup 1}H nuclei is used to monitor the maturation up to 30 days of three different endodontic cement pastes. The 'Solid-liquid' separation of the NMR signals and quasi-continuous distributions of relaxation times allow one to follow the formation of chemical compounds and the build-up of the nano- and subnano-structured C-S-H gel. {sup 1}H populations, distinguished by their different mobilities, can be identified and assigned to water confined within the pores of the C-S-H gel, to crystallization water and Portlandite, and to hydroxyl groups. Changes of the TD-NMR parameters during hydration are in agreement with the expected effects of the different additives, which, as it is known, can substantially modify the rate of reactions and the properties of cementitious pastes. Endodontic cements are suitable systems to check the ability of this non-destructive technique to give insight into the complex hydration process of real cement pastes.

36 MATERIALS SCIENCE↗

Accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas

Purpose: To establish accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas. Methods: Protocol patients with advanced extremity sarcomas were treated with external beam radiation therapy and hyperthermia. Invasive temperature measures were compared to noninvasive magnetic resonance thermal imaging (MRTI) at 1.5 T performed during hyperthermia. Volumetric temperature rise images were obtained using the proton resonance frequency shift (PRFS) technique during heating in a 140 MHz miniannular phased array applicator. MRTI temperature changes were compared to invasive measurements of temperature with a multisensor fiber optic probe inside a no. 15 g catheter in the tumor. Since the PRFS technique is sensitive to drifts in the primary imaging magnetic field, temperature change distributions were corrected automatically during treatment using temperature-stable reference materials to characterize field changes in 3D. The authors analyzed MRT images and compared, in evaluable treatments, MR-derived temperatures to invasive temperatures measured in extremity sarcomas. Small regions of interest (ROIs) were specified near each invasive sensor identified on MR images. Temperature changes in the interstitial sensors were compared to the corresponding ROI PRFS-based temperature changes over the entire treatment and over the steady-state period. Nonevaluable treatments (motion/imaging artifacts, noncorrectable drifts) were not included in the analysis. Results: The mean difference between MRTI and interstitial probe measurements was 0.91 deg. C for the entire heating time and 0.85 deg. C for the time at steady state. These values were obtained from both tumor and normal tissue ROIs. When the analysis is done on just the tumor ROIs, the mean difference for the whole power on time was 0.74 deg. C and during the period of steady state was 0.62 deg. C. Conclusions: The data show that for evaluable treatments, excellent correlation ({Delta}T<1 deg. C) of MRTI-ROI and invasive measurements can be achieved, but that motion and other artifacts are still serious challenges that must be overcome in future work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of magnetic susceptibility and magnetic field strength on porosity estimates determined from low-field nuclear magnetic resonance

The presence of materials with high magnetic susceptibility are known to have an impact on 1H nuclear magnetic resonance (NMR) measurements and in laboratory data this often results in poor estimates of porosity from NMR data. To quantify and understand the cause of the poor NMR porosity estimations, in this laboratory study, we examine the effect of magnetic susceptibility, NMR measurement parameters, and NMR instrument design on NMR measurements. Data were collected with two instruments, each with a different Larmor frequency (2 MHz and 485 kHz), on water-saturated unconsolidated sediments with magnetic susceptibility values ranging from 3.6 × 10 -6 to 7020 × 10 -6 SI. The results show that for materials with low magnetic susceptibility (<378 × 10 -6 SI), the gravimetric porosity is accurately predicted from the NMR measurements. For the samples with high magnetic susceptibility (>987 × 10 -6 SI) the gravimetric porosity is poorly predicted from the 2 MHz NMR measurements made at all echo times (from 0.2 to 3.0 ms). In contrast, the gravimetric porosity is more accurately predicted at an echo time of 0.2 ms for measurements made using the 485 kHz instrument, although at larger echo times (>1.0 ms), the porosity estimate becomes poor. The 485 kHz NMR instrument has non-zero internal magnetic field gradients, similar to those found in borehole instruments, in contrast to the 2 MHz NMR instrument, which has a homogeneous applied magnetic field. Finally, we conclude that differences is the magnetic field strength and higher magnetic field inhomogeneities in the 485 kHz NMR instrument contribute to a reduction of the impact of inhomogeneities in the magnetic field caused by materials with high magnetic susceptibility, allowing for improved porosity estimation. These results indicate that NMR measurements collected at short echo times in low, inhomogeneous static fields, e.g., borehole instruments, may provide accurate estimates of porosity in water saturated sediments, even in the presence of magnetic minerals.

58 GEOSCIENCES↗

Evaluation of the Prostate Bed for Local Recurrence After Radical Prostatectomy Using Endorectal Magnetic Resonance Imaging

Purpose: To summarize the results of a 4-year period in which endorectal magnetic resonance imaging (MRI) was considered for all men referred for salvage radiation therapy (RT) at a single academic center; to describe the incidence and location of locally recurrent disease in a contemporary cohort of men with biochemical failure after radical prostatectomy (RP), and to identify prognostic variables associated with MRI findings in order to define which patients may have the highest yield of the study. Methods and Materials: Between 2007 and 2011, 88 men without clinically palpable disease underwent eMRI for detectable prostate-specific antigen (PSA) after RP. The median interval between RP and eMRI was 32 months (interquartile range, 14-57 months), and the median PSA level was 0.30 ng/mL (interquartile range, 0.19-0.72 ng/mL). Magnetic resonance imaging scans consisting of T2-weighted, diffusion-weighted, and dynamic contrast-enhanced imaging were evaluated for features consistent with local recurrence. The prostate bed was scored from 0-4, whereby 0 was definitely normal, 1 probably normal, 2 indeterminate, 3 probably abnormal, and 4 definitely abnormal. Local recurrence was defined as having a score of 3-4. Results: Local recurrence was identified in 21 men (24%). Abnormalities were best appreciated on T2-weighted axial images (90%) as focal hypointense lesions. Recurrence locations were perianastomotic (67%) or retrovesical (33%). The only risk factor associated with local recurrence was PSA; recurrence was seen in 37% of men with PSA >0.3 ng/mL vs 13% if PSA {<=}0.3 ng/mL (P<.01). The median volume of recurrence was 0.26 cm{sup 3} and was directly associated with PSA (r=0.5, P=.02). The correlation between MRI-based tumor volume and PSA was even stronger in men with positive margins (r=0.8, P<.01). Conclusions: Endorectal MRI can define areas of local recurrence after RP in a minority of men without clinical evidence of disease, with yield related to PSA. Further study is necessary to determine whether eMRI can improve patient selection and success of salvage RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Localizing resonant magnetic perturbations for edge localized mode control in KSTAR

An external 3D magnetic perturbation typically drives a resonant response at the rational surfaces from the core to the edge of tokamak plasmas, due to strong mode coupling and amplification. In this paper, we present a method to isolate the edge from core resonant fields using the ideal perturbed equilibrium code and to design an edge-localized resonant magnetic perturbation (RMP) for effective edge localized mode (ELM) control. A robust feature of the edge-localized RMP is the curtailed response to the field at the low-field-side (LFS) midplane, as opposed to typical RMPs which strongly resonate with the LFS fields. This emphasizes the importance of off-midplane coils to improve ELM control without provoking a large core response that could lead to devastating instabilities. The conceptual design of new ELM control coils based on the edge-localized RMP in KSTAR shows how this new insight can be utilized to enhance the efficiency of our ELM suppression capabilities. Simple window-pane coils matching the edge-localized resonant mode structure substantially expand in the ELM suppression window beyond the existing coil. Further optimization using the flexible optimized coils using space-curves code leads to additional enhancement in the edge-localized control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of stationary filaments with resonant magnetic perturbations in NSTX

The application of resonant magnetic perturbations (RMPs) induces striated heat fluxes on the divertor plate in tokamaks. These striated heat fluxes were previously considered strike point splitting by the intersection between the divertor and predicted magnetic lobe structures. Recently, the existence of stationary 3D filaments has been observed for the first time in National Spherical Torus Experiment (NSTX) plasmas with toroidal mode number n = 3 RMPs. Magnetic field line tracing of these filaments from the midplane to the divertor is consistent with the quantity and the radial and toroidal location of striated heat fluxes observed on the divertor. This study suggests that divertor striated heat flux patterns are linked to these stationary filaments rather than to strike point splitting or magnetic lobe structures for NSTX. This finding will help guide future efforts to understand the heat flux striations in NSTX with RMPs in order to control and reduce the divertor peak heat flux.

RMPs↗

Potential Antiferromagnetic Fluctuations in Hole-Doped Iron-Pnictide Superconductor Ba1-xKxFe2As2 Studied by 75As Nuclear Magnetic Resonance Measurement0.1143/JPSJ.81.054704

We have performed 75As nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR) measurements on single-crystalline Ba1-xKxFe2As2 for x = 0.27–1. 75As nuclear quadruple resonance frequency (νQ) increases linearly with increasing x. The Knight shift K in the normal state shows Pauli paramagnetic behavior with a weak temperature T dependence. K increases gradually with increasing x. By contrast, the nuclear spin–lattice relaxation rate 1/T1 in the normal state has a strong T dependence, which indicates the existence of large antiferomagnetic (AF) spin fluctuations for all x&#x27;s. The T dependence of 1/T1 shows a gaplike behavior below approximately 100 K for 0.6 < x < 0.9. This behaviors is well explained by the change in the band structure with the expansion of hole Fermi surfaces and the shrinkage and disappearance of electron Fermi surfaces at the Brillouin zone (BZ) with increasing x. The anisotropy of 1/T1, represented by the ratio of 1/T1ab to 1/T1c, is always larger than 1 for all x&#x27;s, which indicates that stripe-type AF fluctuations are dominant in this system. The K in the superconducting (SC) state decreases, which corresponds to the appearance of spin-singlet superconductivity. The T dependence of 1/T1 in the SC state indicates a multiple-SC-gap feature. A simple two-gap model analysis shows that the larger superconducting gap gradually decreases with increasing x from 0.27 to 1 and a smaller gap decreases rapidly and nearly vanishes for x > 0.6 where electron pockets in BZ disappear.

36 MATERIALS SCIENCE↗

Site-Selective Determination of Magnetic Helices in BaTiCoFe{sub 10}O{sub 19} by Resonant Magnetic Scattering

Synchrotron radiation intensity measurements were made for single crystals of ferrimagnetic BaTiCoFe{sub 10}O{sub 19} at the BL-6C(3A) beamline of the Photon Factory. The resonant x-ray magnetic scattering (RXMS) method at the Fe K edge makes it possible to determine the magnetic crystal structure, having the magnetic helices for Fe ions in tetrahedral 4f{sub 1}, bipyramidal 2b, and octahedral 2a, 4f{sub 2} and 12k sites. Based on the information on x-ray magnetic circular dichroism (XMCD) and a resonant magnetic scattering factor f''{sub m} ( = 0.23) estimated from BaFe{sub 12}O{sub 19} at E = 7128.2 eV, the magnetic structures have been determined from an asymmetrical ratio {Delta}R (Y{sup +}-Y{sup -})/(Y{sup +}+Y{sup -}), where Y{sup +} and Y{sup -} are scattering intensities for left- and right-circular polarizations, respectively. Spin orientations were estimated in the least-squares procedure to minimize a residual factor of {Sigma}({Delta}R{sub obs}-{Delta}R{sub calc}){sup 2}. The canting angles estimated in this study are 180 deg., 19 deg., 118 deg., 180 deg. and 65 deg. for the magnetic moments of Fe ions in 4f{sub 1}, 2b, 2a, 4f{sub 2} and 12k sites, respectively.

36 MATERIALS SCIENCE↗

Divertor detachment in the pre-fusion power operation phase in ITER during application of resonant magnetic perturbations

Detachment of the divertor plasma during application of resonant magnetic perturbation (RMP) fields is evaluated for hydrogen H-mode plasma during the first pre-fusion power operation (PFPO-1) phase in ITER by 3D plasma boundary modelling with EMC3–EIRENE. Plasma response effects from a linearized, resistive, single fluid MHD model are discussed, which includes partial screening of the externally applied field—but also field amplification near the separatrix. Furthermore, this field amplification is found to play a pivotal role for the magnetic footprint on the divertor targets, but is sensitive to model parameters. Extensions of the footprint beyond the straight portions of the ITER vertical divertor targets, optimized for high stationary heat flux handling, may be possible depending on the level of toroidal rotation in the plasma. Exhaust from the bulk plasma is guided by the helical corrugations (lobes) of the perturbed separatrix, and this results in an upstream heat flux that is distributed over these lobes with lower peak values than in the typical radial heat flux profiles seen in the absence of magnetic perturbations. As a consequence, an earlier onset (with respect to the upstream density) of detachment is found in the traditional strike zone when RMPs are applied, but secondary, non-axisymmetric strike locations appear—and those remain attached at temperatures above 10 eV. Neon seeding can mitigate these non-axisymmetric heat loads, but this becomes less efficient for large magnetic footprints.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic resonance force microscopy with matching frequencies of cantilever and spin

We have studied theoretically magnetic resonance force microscopy with a high-frequency nanomechanical cantilever when the cantilever frequency matches the resonant frequency of a single electron spin. Our analysis shows that in this situation, there is a small probability that the cantilever will oscillate with a large frequency shift. In conclusion, this can open new experimental opportunities for increasing the sensitivity in the detection of a single electron spin or even a single nuclear spin by using a high-frequency cantilever.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A reactor for high-throughput high-pressure nuclear magnetic resonance spectroscopy

The design of a reactor for operando nuclear magnetic resonance (NMR) monitoring of high-pressure gas-liquid reactions is described. The Wisconsin High Pressure NMR Reactor (WiHP-NMRR) design comprises four modules: a sapphire NMR tube with titanium tube holder rated for pressures as high as 1000 psig (68 atm) and temperatures ranging from −90 to 90 °C, a gas circulation system that maintains equilibrium concentrations of dissolved gases during gas-consuming or gas-releasing reactions, a liquid injection apparatus that is capable of adding measured amounts of solutions to the reactor under high pressure conditions, and a rapid wash system that enables the reactor to be cleaned without removal from the NMR instrument. The WiHP-NMRR is compatible with commercial 10 mm NMR probes. Reactions performed in the WiHP-NMRR yield high quality, information-rich, and multinuclear NMR data over the entire reaction time course with rapid experimental turnaround.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗