Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Reduction and analysis of magnetometer data from Mariners 4 and 5

In studies of data from the Mariner 4 and Mariner 5 magnetometers evidence has been found that during the flights, negative (toward the sun) polarity dominated at latitudes above the solar equatorial plane and positive polarity dominated at latitudes below this plane. A subsequent check of data taken with other spacecraft during 1964 through 1967 provided additional evidence of this effect. It is suggested that the dominant polarity of the interplanetary magnetic field follows the hemisphere-dependent dipolar field of the sun. Thus, the photospheric dipolar field may be an important source of the interplanetary magnetic field, especially at quiet times. It has also been found that, for an interplanetary magnetic field of a given polarity, the north-south component has a nonzero mean value in regions above and below the solar equatorial plane.

Source record↗

Superconducting rock magnetometer system

A three axis magnetometer system intended for use in the magnetic measurement of lunar rock samples was designed, fabricated and delivered to NASA Manned Spacecraft Center. The system has a four inch diameter room temperature sample access region and is fitted with three orthogonal magnetic field sensors enclosing this region. Two superconducting magnetic shields are incorporated, which are designed to eliminate external magnetic noise from the sense coils. A superconducting solenoid is mounted coaxially with the sample region and this provides axial magnetic fields up to 1,000 gauss. The system was designed for measuring magnetic moments of geophysical samples, especially remanent moments of lunar samples. The sensitivity of the system in all three axes is about 2 x 10 to the -7th power EMU square root HZ peak to peak, measured in the 0 to 1 Hz bandwidth.

Source record↗

Lunar surface magnetometer design review

Design and fabrication parameters of a lunar surface magnetometer are discussed. Drawings and requirements for mechanical design, electronic packaging design, thermal design, quality assurance and systems testing are included.

Source record↗

Determination of sounding rocket position and attitude from radar and magnetometer data

The techniques are described that were used to determine the trajectories and orientations of three sounding rockets instrumented to study the aurora. The radar plot board data were fitted to a near earth expansion of the force of gravity to determine the trajectory. Only onboard magnetometer data were used to determine the attitude of the payload with respect to the earth's magnetic field. Computer programs in the FORTRAN language are available which generate the trajectory and attitude parameters.

Pongratz, M.↗

A pressure scanning Fabry-Perot magnetometer.

Description of an oscillating magnetic analyzer (KDP crystal plus Glan-Thompson prism) coupled to an echelle-interferometer spectrograph, and of single-slit magnetometer which by pressure variations can be made to scan the entire profiles of the circularly and linearly polarized Zeeman components. Freon gas is used as the scanner gas with wavelength displacements of 0.02 A per 0.1 in. Hg pressure change at the NaD lines. The available scan range is 15 A in the visual spectral region.

Fay, T. D.↗

A variable conductance heat pipe/radiator for the lunar surface magnetometer.

The device was developed to supplement the existing cooling system of the Apollo 16 Lunar Surface Magnetometer (LSM). Analysis and tests showed that two such devices, inserted by an astronaut into receptacles on opposite sides of the electronics package, would reduce the diurnal temperature variation by about 40% and thereby would considerably increase the reliability of 50,000 welded connections. The LSM design constraints, selection of a variable conductance technique, heat pipe/radiator design features, and thermal performance are discussed.

Kirkpatrick, J. P.↗

Sensor noise in low-level flux-gate magnetometers.

The noise mechanism in a well-designed magnetometer is shown to be due to small-scale magnetic moments which are probably small volumes of the core material that are not oriented by the drive field. Design developments include the sense coil radius and the development of a drive waveform which yields considerably improved performance over the commonly used sine wave drive.

Scouten, D. C.↗

A summary of the results from the UCLA OGO-5 fluxgate magnetometer

The OGO-5 fluxgate magnetometer experiment (E-14) was designed to measure the vector magnetic field over the full range of the OGO-5 orbit. Thus, it had a dynamic range of + or - 64,000 gamma yet it maintained a precision of + or - 1/16 gamma at all times. This enabled a broad spectrum of problems to be attached. Studies of the magnetospheric waves, currents, waves-particle interactions, pitch angle distributions and wave normal directions were made. The structure of the magnetopause, the magnetotail, and bow shock were probed, waves and discontinuities in the solar wind were examined and the various phases of substorms were examined in depth.

Coleman, P. J., Jr.↗

Magnetometer instrument team studies for the definition phase of the outer planets grand tour

The work performed by the magnetic fields investigation team during the mission definition phases of the Outer Planets Grand Tour (OPGT) and the Mariner Jupiter Saturn (MJS) Missions is reported. This work involved three tasks: (1) defining the objectives of the magnetic fields investigations, (2) defining the magnetometer systems required to meet these objectives, and (3) developing and testing hardware elements in certain mission-specific areas.

Coleman, P. J., Jr.↗

Lunar surface magnetometer experiment

The Apollo 16 lunar surface magnetometer (LSM) activation completed the network installation of magnetic observatories on the lunar surface and initiated simultaneous measurements of the global response of the moon to large-scale solar and terrestrial magnetic fields. Fossil remanent magnetic fields have been measured at nine locations on the lunar surface, including the Apollo 16 LSM site in the Descartes highlands area. This fossil record indicates the possible existence of an ancient lunar dynamo or a solar or terrestrial field much stronger than exists at present. The experimental technique and operation of the LSM are described and the results obtained are discussed.

Dyal, P.↗

Lunar portable magnetometer experiment

The purpose of the Apollo 16 lunar portable magnetometer (LPM) experiment is to measure the permanent magnetic field at different geological sites on the lunar surface. The LPM field measurements are a vector sum of the steady remanent field from the lunar crust and of the time-varying ambient fields. The remanent magnetic fields measured in the Descartes region are the largest extraterrestrial fields yet measured in situ. These measurements show for the first time that the Descartes highlands have a stronger remanent magnetization than do the mare regions of the previous Apollo landing sites. The experimental technique used in the LPM experiment is described and the preliminary results obtained are discussed.

Dyal, P.↗

Iron abundance in the moon from magnetometer measurements

Apollo 12 and 15 lunar surface magnetometer data with simultaneous lunar orbiting Explorer 35 data are used to plot hysteresis curves for the whole moon. From these curves a whole-moon permeability mu = 1.029 + 0.024 or - 0.019 is calculated. This result implies that the moon is not composed entirely of paramagnetic material, but that ferromagnetic material such as free iron exists in sufficient amounts to dominate the bulk lunar susceptibility. From the magnetic data the ferromagnetic free iron abundance is calculated. Then for assumed compositional models of the moon the additional paramagnetic iron is determined, yielding total lunar iron content. The calculated abundances are as follows: ferromagnetic free iron = 5 + or - 4 wt. percent, and total iron in the moon = 9 + or - 4 wt. percent.

Parkin, C. W.↗

The Pioneer 11 high-field fluxgate magnetometer

The High Field Fluxgate Magnetometer Experiment flow aboard the Pioneer 11 spacecraft to investigate Jupiter's magnetic field is described. The instrument extends the spacecraft's upper limit measurement capability by more than an order of magnitude to 17.3 gauss with minimum power and volume requirements.

Acuna, M. H.↗

Iron abundance in the moon from magnetometer measurements

Apollo 12 and 15 lunar surface magnetometer data with simultaneous lunar orbiting Explorer 35 data are used to plot hysteresis curves for the whole moon. From these curves a whole-moon permeability of 1.029 (+0.024 or -0.019) is calculated. This result implies that the moon is not composed entirely of paramagnetic material, but that ferromagnetic material such as free iron exists in sufficient amounts to dominate the bulk lunar susceptibility. From the magnetic data the ferromagnetic free iron abundance is calculated. Then for assumed compositional models of the moon the additional paramagnetic iron is determined, yielding total lunar iron content. The calculated abundances are as follows: ferromagnetic free iron, 5 plus or minus 4 wt %; total iron in the moon, 9 plus or minus 4 wt %.

Parkin, C. W.↗

Fluxgate magnetometers for outer planets exploration

The exploration of the interplanetary medium and the magnetospheres of the outer planets requires the implementation of magnetic field measuring instrumentation with wide dynamic range, high stability, and reliability. The fluxgate magnetometers developed for the Pioneer 11 and Mariner-Jupiter-Saturn missions are presented. These instruments cover the range of .01 nT to 2 million nT with optimum performance characteristics and low power consumption.

Acuna, M. H.↗

Summary of initial results from the GSFC fluxgate magnetometer on Pioneer 11

The main magnetic field of Jupiter was measured by the Fluxgate Magnetometer on Pioneer 11 and analysis reveals it to be relatively more complex than expected. In a centered spherical harmonic representation with a maximum order of n = 3 (designated GSFC model 04), the dipole term (with opposite polarity to the Earth's) has a moment of 4.28 Gauss x (Jupiter radius cubed), tilted by 9.6 deg towards a system 111 longitude of 232. The quadrupole and octupole moments are significant, 24% and 21% of the dipole moment respectively, and this leads to deviations of the planetary magnetic field from a simple offset tilted dipole for distances smaller than three Jupiter radii. The GSFC model shows a north polar field strength of 14 Gauss and a south polar field strength of 10.4 Gauss. Enhanced absorption effects in the radiation belts may be predicted as a result of field distortion.

Acuna, M. H.↗

A precision six-meter deployable boom for the Mariner-Venus-Mercury 1973 magnetometer experiment

A unique deployable boom developed for accurately positioning magnetometers 6 meters (19.7 feet) from a spacecraft is described. Weight, mounting system, magnetic cleanliness, thermal dimensional stability, and natural frequency were critical constraints that were met. The boom was flown on Mariner 10 and deployed flawlessly. The design, development, and testing of the boom and optical alignment of the sensors are described. Design trades and problem solutions are discussed.

Burdick, H. F.↗

Properties of the moon and its environment from lunar magnetometer measurements

Lunar analysis of data from a total of nine lunar magnetometers is described. Results obtained concerning electromagnetic, compositional, and structural properties of the lunar interior are discussed. Specific topics covered include: lunar magnetic permeability and iron abundance; limits on a highly conducting lunar core; lunar electrical conductivity; and internal structure inferred from conductivity and permeability results.

Parkin, C. W.↗