Search NASA⌕ Search

SEARCH · Search NASA

Results for “MC&A Program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

X-34 Project: Overview and Status

This document is a viewgraph presentation which reviews the progress in the X-34 Project. The X-34 program demonstrates the technologies and operations required to develop the next generation of reusable launch vehicles. The presentation includes descriptions and design views of the vehicle. It reviews features of the MC-1 (i.e. Fastrac Engine), and the propulsion system. It also includes information about the thermal protection system.

Springer, Anthony M.↗

Candidate-Landing Sites and Backups for the Mars Surveyor Program in the Schiaparelli. Crater Region

Our Survey area comprises the Sinus Sabeus NW quadrangle that includes most of the Schiaparelli crater and part of the Arabia SW region (3 N to 15 S Lat.) and (0 to 337.5 W long.) and covers all regions that show a potential hydrogeological link with the Schiaparelli impact structure. This area is hereafter defined as the Schiaparelli Crater Region. The Schiaparelli crater region is one of the most documented MOC targets. Up to now, MGS MOC camera took two dozen images at an average of 5m/pxl resolution that not only provide an exceptional insight on the local geology and morphology, but give also key-elements to assess landing safety criteria. In addition, the MOLA topographic profile No. 23 passes through part of the crater basin allowing the adjustment of the elevation as previously known from the Viking mission (USGS I-2125, 1991). Beyond the Mars Polar Lander mission that will land next December, the future missions (2001 APEX, 2003, and 2005) are led by a series of science objectives and engineering constraints that must be considered in order to select landing sites that will fulfill the Surveyor Program's objectives. The search for a sound and safe candidate-site (without ending up with the usual "safe but boring" or "fascinating but too risky" site) is usually limited by the data available to the investigator, by the data accuracy (e.g. poor image resolution, poor altimetry), and the lack of crucial information for science and safety that can be derived from them. The Schiaparelli region provides an exception to this recurrent pattern. We listed the preliminary constraints for landing site selection identified for the Surveyor '01 mission, in terms of safety requirements and data needed and compared them against the existing information and/or data already available for the Schiaparelli region. The engineering constraints of '03 and '05 are not designated yet but, since they are also related to atmospheric density and Lander designs, we will assume that these points will be comparable to '01. The main difference will reside in the rover design, the Rocky-7 class rover being bigger than Marie Curie ('01) will be able to overcome bigger obstacles. We listed then the main objectives of the Surveyor Program and compared them with the potential offered by the Schiaparelli Crater Region to document them. Within the survey area, the Schiaparelli impact crater is 2.5 S/343.3 W (USGS 1-1376, MC-20 NW, 1981) and occupies a significant surface area. The crater has been proposed as a potential candidate-site in the past years. The purpose of this study is to show that, not only the Schiaparelli Crater would be a high-priority target, but that the region where it is located offer several very-high potential back-up sites, all within science and engineering constraints, that make this region probably the most promising candidate area so far.

Cabrol, Nathalie A.↗

URANIUM HOLDUP MONITORING WITH COMPTON IMAGING AS FUNCTION OF DEPTH AND MASS

Mass quantification using standoff gamma detection is a logical progression for MC&A applications in uranium processing facilities. While obtaining a ground truth from physical collection and weighing of masses is ideal and routine, it poses a logistical problem from both a standpoint of ALARA programs as well as interruptions to operations. The standard approach is the Generalized Geometry in Holdup (GGH) method that can apply for many cases where geometries of the holdup match simulated models; however, there are many cases where a model may not exist or a feature of the holdup geometry is such that it does not match a model particularly well.1 Gamma imaging at standoff distances and outside process equipment has potential to address these shortcomings and improve mass estimations while reducing personnel exposure; however, algorithms still require a significant degree of benchmarking to build sufficient confidence in algorithms before displacing GGH in some procedures. This paper presents the creation of a set of laboratory standards of depleted U3O8 in fixed size containers covering a range of masses and effective thicknesses up to the infinite thickness for the 185-keV line. These blocks are identically sized aluminum boxes loaded such that a thin, flat face is placed towards the imager, while the back side contains closed cell foam to apply pressure to keep the powder in a fixed position at the front face as the sources are manipulated for measurements. Included is an analysis of the mass estimation using a commercially available Compton imaging instrument where multiple geometries are created showing limitations in current methodologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kilovoltage cone-beam CT: Comparative dose and image quality evaluations in partial and full-angle scan protocols

Purpose: To assess imaging dose of partial and full-angle kilovoltage CBCT scan protocols and to evaluate image quality for each protocol. Methods: The authors obtained the CT dose index (CTDI) of the kilovoltage CBCT protocols in an on-board imager by ion chamber (IC) measurements and Monte Carlo (MC) simulations. A total of six new CBCT scan protocols were evaluated: Standard-dose head (100 kVp, 151 mA s, partial-angle), low-dose head (100 kVp, 75 mA s, partial-angle), high-quality head (100 kVp, 754 mA s, partial-angle), pelvis (125 kVp, 706 mA s, full-angle), pelvis spotlight (125 kVp, 752 mA s, partial-angle), and low-dose thorax (110 kVp, 271 mA s, full-angle). Using the point dose method, various CTDI values were calculated by (1) the conventional weighted CTDI (CTDI{sub w}) calculation and (2) Bakalyar's method (CTDI{sub wb}). The MC simulations were performed to obtain the CTDI{sub w} and CTDI{sub wb}, as well as from (3) central slice averaging (CTDI{sub 2D}) and (4) volume averaging (CTDI{sub 3D}) techniques. The CTDI values of the new protocols were compared to those of the old protocols (full-angle CBCT protocols). Image quality of the new protocols was evaluated following the CBCT image quality assurance (QA) protocol [S. Yoo et al., ''A quality assurance program for the on-board imager registered ,'' Med. Phys. 33(11), 4431-4447 (2006)] testing Hounsfield unit (HU) linearity, spatial linearity/resolution, contrast resolution, and HU uniformity. Results: The CTDI{sub w} were found as 6.0, 3.2, 29.0, 25.4, 23.8, and 7.7 mGy for the new protocols, respectively. The CTDI{sub w} and CTDI{sub wb} differed within +3% between IC measurements and MC simulations. Method (2) results were within {+-}12% of method (1). In MC simulations, the CTDI{sub w} and CTDI{sub wb} were comparable to the CTDI{sub 2D} and CTDI{sub 3D} with the differences ranging from -4.3% to 20.6%. The CTDI{sub 3D} were smallest among all the CTDI values. CTDI{sub w} of the new protocols were found as {approx}14 times lower for standard head scan and 1.8 times lower for standard body scan than the old protocols, respectively. In the image quality QA tests, all the protocols except low-dose head and low-dose thorax protocols were within the tolerance in the HU verification test. The HU value for the two protocols was always higher than the nominal value. All the protocols passed the spatial linearity/resolution and HU uniformity tests. In the contrast resolution test, only high-quality head and pelvis scan protocols were within the tolerance. In addition, crescent effect was found in the partial-angle scan protocols. Conclusions: The authors found that CTDI{sub w} of the new CBCT protocols has been significantly reduced compared to the old protocols with acceptable image quality. The CTDI{sub w} values in the point dose method were close to the volume averaging method within 9%-21% for all the CBCT scan protocols. The Bakalyar's method produced more accurate dose estimation within 14%. The HU inaccuracy from low-dose head and low-dose thorax protocols can render incorrect dose results in the treatment planning system. When high soft-tissue contrast data are desired, high-quality head or pelvis scan protocol is recommended depending on the imaging area. The point dose method can be applicable to estimate CBCT dose with reasonable accuracy in the clinical environment.

60 APPLIED LIFE SCIENCES↗

MAGNTY - Program for calculating velocities in magnified region of turbomachines

Computer program, MAGNFY, calculates the velocity distribution through the passage between and over blade surfaces of blade rows for turbines and compressors. Using the input of other programs, MAGNFY obtains velocities on smaller than normal finite difference mesh in any part of the blade-to-blade passage.

Katsanis, T.↗

Fundamental Research and Development for Improved Crystalline Silicon Solar Cells: Final Subcontract Report, March 2002 - July 2006

This report summarizes the progress made by Georgia Tech in the 2002-2006 period toward high-efficiency, low-cost crystalline silicon solar cells. This program emphasize fundamental and applied research on commercial substrates and manufacturable technologies. A combination of material characterization, device modeling, technology development, and complete cell fabrication were used to accomplish the goals of this program. This report is divided into five sections that summarize our work on i) PECVD SiN-induced defect passivation (Sections 1 and 2); ii) the effect of material inhomogeneity on the performance of mc-Si solar cells (Section 3); iii) a comparison of light-induced degradation in commercially grown Ga- and B-doped Czochralski Si ingots (Section 4); and iv) the understanding of the formation of high-quality thick-film Ag contacts on high sheet-resistance emitters (Section 5).

14 SOLAR ENERGY↗

Manpower forecast program

Program reports distribution of actual manpower levels in each section versus accounts, projects versus sections, sections versus manpower classes, and project offices versus sections.

Mc Cornock, M. D.↗

Structural Reliability Using Probability Density Estimation Methods Within NESSUS

A reliability analysis studies a mathematical model of a physical system taking into account uncertainties of design variables and common results are estimations of a response density, which also implies estimations of its parameters. Some common density parameters include the mean value, the standard deviation, and specific percentile(s) of the response, which are measures of central tendency, variation, and probability regions, respectively. Reliability analyses are important since the results can lead to different designs by calculating the probability of observing safe responses in each of the proposed designs. All of this is done at the expense of added computational time as compared to a single deterministic analysis which will result in one value of the response out of many that make up the density of the response. Sampling methods, such as monte carlo (MC) and latin hypercube sampling (LHS), can be used to perform reliability analyses and can compute nonlinear response density parameters even if the response is dependent on many random variables. Hence, both methods are very robust; however, they are computationally expensive to use in the estimation of the response density parameters. Both methods are 2 of 13 stochastic methods that are contained within the Numerical Evaluation of Stochastic Structures Under Stress (NESSUS) program. NESSUS is a probabilistic finite element analysis (FEA) program that was developed through funding from NASA Glenn Research Center (GRC). It has the additional capability of being linked to other analysis programs; therefore, probabilistic fluid dynamics, fracture mechanics, and heat transfer are only a few of what is possible with this software. The LHS method is the newest addition to the stochastic methods within NESSUS. Part of this work was to enhance NESSUS with the LHS method. The new LHS module is complete, has been successfully integrated with NESSUS, and been used to study four different test cases that have been proposed by the Society of Automotive Engineers (SAE). The test cases compare different probabilistic methods within NESSUS because it is important that a user can have confidence that estimates of stochastic parameters of a response will be within an acceptable error limit. For each response, the mean, standard deviation, and 0.99 percentile, are repeatedly estimated which allows confidence statements to be made for each parameter estimated, and for each method. Thus, the ability of several stochastic methods to efficiently and accurately estimate density parameters is compared using four valid test cases. While all of the reliability methods used performed quite well, for the new LHS module within NESSUS it was found that it had a lower estimation error than MC when they were used to estimate the mean, standard deviation, and 0.99 percentile of the four different stochastic responses. Also, LHS required a smaller amount of calculations to obtain low error answers with a high amount of confidence than MC. It can therefore be stated that NESSUS is an important reliability tool that has a variety of sound probabilistic methods a user can employ and the newest LHS module is a valuable new enhancement of the program.

Chamis, Chrisos C.↗

XXVIIth International Conference on Supersymmetry and Unification of Fundamental Interactions (SUSY 2019) (Final Report)

Supersymmetry (SUSY) is one of most elegant extensions of the Standard Model (SM) and explains the puzzles of the SM by providing a candidate to explain the dark matter content of the universe, allowing scientists to understand the origin of the electroweak scale requiring the top mass to be around 170 GeV and leading to the unification of forces at a grand unified scale. Further the minimal supersymmetric standard model (MSSM) predicts the Higgs boson mass to be less than 135 GeV. The discovery of the Higgs Boson with mass around 125 GeV at the LHC has provided a major support to SUSY ideas. Searches for SUSY are ongoing at the Large Hadron Collider (LHC). Direct and indirect dark matter experiments are searching for a particle dark matter candidate which arises most naturally in SUSY models. Proton decay predicted by SUSY grand unified theories is being searched for at deep underground experiments. In addition, recent advances in neutrino and dark matter physics, observational astrophysics, precision cosmology and the promising new window into the cosmos opened by the direct detection of gravitational waves, have brought new ideas on the potential connections between new fundamental particles and our understanding of their impact on the early universe and its evolution. At present, the major questions include: Is SUSY still the best candidate for models beyond the SM? Do we have any well motivated alternative to SUSY? Have we exhausted all possibilities to search for new physics at high and low energy scales? XXVIIth International Conference on Supersymmetry and Unification of Fundamental Interactions (SUSY 2019), hosted by Texas A&M University – Corpus Christi during May 20-24, 2019, provided a unique venue to discus and understand the status of SUSY, connection between particle physics and cosmology, supersymmetry and its alternative, Higgs sector, neutrino sector, flavor sector, dark matter, electroweak phase transition, astroparticle physics, gravitational waves and string theory. Discussion of results from the LHC, recent neutrino experiments and observations, direct and indirect dark matter detection experiments, detection of gravitational waves, data from particle colliders, as well as measurements of the CMB and Large Scale Structure were an integral part of SUSY 2019. To ensure the younger participants will benefit from the conference the most, the conference was preceded by the 4 day long pre-SUSY summer school for graduate students and postdocs. The invited speakers were leading scientists in the fields of SUSY interest. The school took place on Texas A&M University – Corpus Christi campus during the week prior the SUSY 2019 conference (May 15 – 18, 2019). Since its inception in 1993, SUSY has become one of the most important and widely attended international meetings in high energy physics, devoted to new ideas in fundamental particle physics. SUSY 2019 brought together approximately 250 scientists, theorists, phenomenologists, experimentalists and cosmologists, (including over 60 graduate students and 70 postdocs) representing 22 nations: Australia, Belgium, Canada, Chile, China, Colombia, France, Germany, India, Italy, Japan, Mexico, Peru, Portugal, Romania, South Korea, Spain, Sweden, Switzerland, Taiwan, United Kingdom and United States. SUSY 2019 provided a stimulating venue for the exchange of scientific ideas among experts in dark matter, neutrino physics, particle physics, astrophysics and cosmology. The following scientific topics were delivered during SUSY 2019 in form of 44 plenary talks and over 200 parallel talks: Unification of Forces; Electroweak, Top and Higgs Physics; Precision Calculations and MC tools; BSM in Flavor Physics; Neutrino Masses: Models and Phenomenology; Cosmology and Gravitational Waves; Dark Matter, Astroparticle Physics; Formal Field Theory and Strings; Alternatives to Supersymmetry; Quantum Information: Machine Learning/Big Data. 28 talks were given during the pre-SUSY program related to the following topics: Neutrino Physics; Big Data; Collider Physics & SUSY; String Phenomenology; Cosmology; Dark Matter; SUSY Models and Phenomenology

43 PARTICLE ACCELERATORS↗

Dynamic Event Tree Analysis Through RAVEN

Conventional Event-Tree (ET) based methodologies are extensively used as tools to perform reliability and safety assessment of complex and critical engineering systems. One of the disadvantages of these methods is that timing/sequencing of events and system dynamics is not explicitly accounted for in the analysis. In order to overcome these limitations several techniques, also know as Dynamic Probabilistic Risk Assessment (D-PRA), have been developed. Monte-Carlo (MC) and Dynamic Event Tree (DET) are two of the most widely used D-PRA methodologies to perform safety assessment of Nuclear Power Plants (NPP). In the past two years, the Idaho National Laboratory (INL) has developed its own tool to perform Dynamic PRA: RAVEN (Reactor Analysis and Virtual control ENvironment). RAVEN has been designed in a high modular and pluggable way in order to enable easy integration of different programming languages (i.e., C++, Python) and coupling with other application including the ones based on the MOOSE framework, developed by INL as well. RAVEN performs two main tasks: 1) control logic driver for the new Thermo-Hydraulic code RELAP-7 and 2) post-processing tool. In the first task, RAVEN acts as a deterministic controller in which the set of control logic laws (user defined) monitors the RELAP-7 simulation and controls the activation of specific systems. Moreover, RAVEN also models stochastic events, such as components failures, and performs uncertainty quantification. Such stochastic modeling is employed by using both MC and DET algorithms. In the second task, RAVEN processes the large amount of data generated by RELAP-7 using data-mining based algorithms. This paper focuses on the first task and shows how it is possible to perform the analysis of dynamic stochastic systems using the newly developed RAVEN DET capability. As an example, the Dynamic PRA analysis, using Dynamic Event Tree, of a simplified pressurized water reactor for a Station Black-Out scenario is presented.

42 ENGINEERING↗

Computerized methods for trafficability analysis

Computer program produces trafficability maps displaying terrain characteristics in digital form for computer analysis. Maps serve as aid to vehicular operation and highway planning based on maneuverability parameters.

Lewandowski, G. M.↗

TU-AB-BRC-08: Egs-brachy, a Fast and Versatile Monte Carlo Code for Brachytherapy Applications

Purpose: To introduce egs-brachy, a new, fast, and versatile Monte Carlo code for brachytherapy applications. Methods: egs-brachy is an EGSnrc user-code based on the EGSnrc C++ class library (egs++). Complex phantom, applicator, and source model geometries are built using the egs++ geometry module. egs-brachy uses a tracklength estimator to score collision kerma in voxels. Interaction, spectrum, energy fluence, and phase space scoring are also implemented. Phase space sources and particle recycling may be used to improve simulation efficiency. HDR treatments (e.g. stepping source through dwell positions) can be simulated. Standard brachytherapy seeds, as well as electron and miniature x-ray tube sources are fully modelled. Variance reduction techniques for electron source simulations are implemented (Bremsstrahlung cross section enhancement, uniform Bremsstrahlung splitting, and Russian Roulette). TG-43 parameters of seeds are computed and compared to published values. Example simulations of various treatments are carried out on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core. Results: TG-43 parameters calculated with egs-brachy show excellent agreement with published values. Using a phase space source, 2% average statistical uncertainty in the PTV ((2mm){sup 3} voxels) can be achieved in 10 s for 100 {sup 125}I or {sup 103}Pd seeds in a 36.2 cm{sup 3} prostate PTV, 31 s for 64 {sup 103}Pd seeds in a 64 cm{sup 3} breast PTV, and 56 s for a miniature x-ray tube in a 27 cm{sup 3} breast PTV. Comparable uncertainty is reached in 12 s in a (1 mm){sup 3} water voxel 5 mm away from a COMS 16mm eye plaque with 13 {sup 103}Pd seeds. Conclusion: The accuracy of egs-brachy has been demonstrated through benchmarking calculations. Calculation times are sufficiently fast to allow full MC simulations for routine treatment planning for diverse brachytherapy treatments (LDR, HDR, miniature x-ray tube). egs-brachy will be available as free and open-source software to the medical physics research community. This work is partially funded by the Canada Research Chairs program, the Natural Sciences and Engineering Research Council of Canada, and the Ontario Ministry of Research and Innovation (Ontario Early Researcher Award).

60 APPLIED LIFE SCIENCES↗

Simulation of the Focusing DIRC Optics with Mathematica

The Focusing DIRC is considered for the Barrel PID at a possible Super-B factory. To reduce sensitivity to background, it would be desirable to reduce a size of the present BaBar photon detector. One way to do it is to replace it with a focusing optics and use smaller photon detector pixels. We have simulated the focusing optics with simulation software based on a 3D calculation performed with the Mathematica program. The software does not use Optica package, instead, it uses its own 3D algorithm. The advantage of the presented method is that it is transparent, fast and that it uses a full backing of the Mathematica graphics, and it does not require expertise to run Geat4 MC software.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗