At least 217 records · Page 12

Acoustic gas volume fraction measurement in a multiphase flowing liquid

Apparatus and methods for the measurement of gas volume fraction of produced oil are described. A first method measures the response of a pipe containing the produced oil excited by a source of vibration in the form of an acoustic frequency chirp containing a linearly varying range of frequencies in the tens of kilohertz range encompassing at least one resonant mode of the pipe. As the gas volume fraction increases, the location of the peak maximum of the measured frequency spectrum responsive to the excitation increases in frequency, and the height of the peak maximum increases, thereby permitting a linear calibration curve to be obtained. A second method measures the response of a pipe containing the produced oil to excitation by a continuous source of vibration having a chosen frequency above those which excite flexural vibrations in the pipe and simultaneously excite acoustic waves in the fluid contained in the pipe, known as the coincidence frequency. Gas present in the fluid will interrupt sound propagation or reverberation, thereby generating fluctuations in the amplitude of the measured vibrations of the pipe. The amplitude fluctuation level provides a measure of the gas volume present inside the pipe. A third method measures the response of a pipe containing the produced oil to excitation by a high-bandwidth, short pulse having a chosen center frequency above the coincidence frequency. Gas present in the fluid will interrupt pulse propagation, thereby generating fluctuations in the amplitude of the measured vibrations of the pipe.

Sinha, Dipen N.↗

Comparison of experimental and computational methods for discharge measurements from tidal wetlands

This short communication describes the use and comparison of three methods used to calculate the flow discharge from a tidal wetland stream. The techniques presented are a) bottom-mounted ADCP deployments, b) vessel-mounted ADCP transects, and c) a volume inundation spatial model that relies on a high-resolution LiDAR dataset and time-series of water surface elevation data. The relative agreement between these three methods is used to build confidence in the application of these techniques to the challenge of deducing flow discharge from tidal wetlands.

54 ENVIRONMENTAL SCIENCES↗

Thermophysical Property Measurements: Improved Density, Viscosity and Thermal Diffusivity Methods

The technical bases and methods developed at Argonne to measure thermophysical properties of molten salt mixtures are summarized and representative results provided to show the accuracy and precision achieved. Three key measurements addressed in this report are density, viscosity and thermal diffusivity. The densities of two eutectic FLiNaK mixtures were measured at temperatures to approximately 750 °C and the results are compared with literature values. The results are used to show how the effect of salt surface tension is taken into account in the density calculation and how the surface tension for other salt mixtures is being measured. Viscosity measurements of eutectic FLiNaK are shown to illustrate improvements to the measurement method being made to address and minimize the sources of error and uncertainties in the reported values. Thermal diffusivity measurements of FLiNaK are shown to illustrate the measurement method developed at Argonne and the achieved precision. The thermal diffusivity of the graphite used to make the cells that contain the salts during analyses was measured to assess the relative contribution to the response. The improved procedures developed in this work are being applied in property measurements of other salts of interest.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental comparison of pyranometer, reflectometer, and spectrophotometer methods for the measurement of roofing product albedo

Albedo (solar reflectance) can be measured outdoors with a pyranometer or indoors with a hemispherical reflectometer or a spectrophotometer. The current study evaluates these methods and their applicability to roofing materials by measuring and comparing the ASTM E1918 (pyranometer), non-ASTM E1918A (alternative pyranometer), ASTM C1549 (reflectometer), and E903 (spectrophotometer) albedos of 10 roofing products, including three single-ply membranes, one asphalt shingle, three roofing aggregates, and three high-profile tiles. It uses full-size (4 m × 4 m) assemblies in the E1918 and E1918A trials; corrects the E1918 albedos to remove shadow and background errors; and evaluates C1549 and E903 albedos with two different irradiance spectra, one global horizontal and the other beam normal. E1918A albedos matched E1918 corrected (E1918_cor) albedos to within 0.036. Furthermore, agreement between C1549 air mass 1 global horizontal (C1549_G1) albedo and E1918_cor albedo was within 0.015 for membrane and shingle coupons, and within 0.031 for aggregates, though the uncertainty in the latter agreement was up to 0.043. After minor corrections, C1549_G1 albedos of flat or slightly convex tile chips were 0.032–0.052 higher than the E1918_cor albedos of their corresponding high-profile tile assemblies because high-profile surfaces have concavities. Switching to the beam-normal albedo C1549_1.5E increased the C1549 albedos of the 10 tested products by 0.004–0.054, with the largest increases (C1549_1.5E – C1549_G1) accruing to spectrally selective cool colors. Using C1549_1.5E albedo to characterize a chip of a cool-colored tile compounded the error induced by representing a high-profile surface by a flat or slightly convex specimen.

14 SOLAR ENERGY↗

Python Measurement-Informed Modelling Method (PythonMIMM) v1.02

This Python program implements the calculations for electrical energy efficiency and electrical losses in the paper "Energy and power quality measurement for electrical distribution in AC and DC microgrid buildings" (https://www.sciencedirect.com/science/article/abs/pii/S0306261921015658). The inputs are metered voltage, current, or power data of meters located throughout the DC system. In the absence of metered data, the user must input some other information about the building such as the types of power converters or wire lengths. The program will build a loss model of the DC system based on metered data and electrical information. It will also generate an equivalent AC system and determine the losses and efficiency.

Gerber, Daniel [Lawrence Berkeley National Laborat↗

Innovative Method for Reliable Measurement of PEM Water Electrolyzer Component Resistances

Understanding the sheet resistance of porous electrodes is essential for improving the performance of polymer electrolyte membrane (PEM) water electrolyzers and related technologies. Despite its importance, existing methods often fail to provide reliable and comprehensive data, especially for porous materials with complex morphologies and non‐uniform thicknesses. This study introduces a robust and straightforward method for determining the sheet resistance of porous electrodes using a novel probe concept based on industrial printed circuit board (PCB) technology. This probe measures resistance across ten distances, ranging from 250 µm to 2500 µm, enabling local mapping of resistance. The study focuses on the sheet resistance of key components in PEM water electrolyzers, including the gas diffusion layer (GDL), porous transport layer (PTL), and catalyst layers deposited on a membrane. Additionally, an image‐processing‐based method is presented to obtain the thickness distribution of the studied catalyst layers, facilitating a detailed analysis of the electrical in‐plane resistivity with thickness variations. Overall, this methodology has the potential to expedite material integration and bridge the gap between electrode engineering and single‐cell testing, thereby advancing the development of PEM water electrolyzers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-reversed nonlinear acoustic downhole pore pressure measurements

Apparatus (10) and methods for measurement of pore pressure in rock formations through a metal borehole casing (32) after a well is cased and cemented, are described. Such measurements may be accomplished by using the Dynamic Acoustic Elasticity (DAE) method for characterizing nonlinear parameters by perturbing a selected rock formation region with a High Amplitude, Low Frequency (HALF) acoustic strain wave, and probing this region using a Low Amplitude, High Frequency (LAHF) acoustic wave (18), (22). Time reversal techniques (36) may be employed for focusing acoustic energy into the formation in the vicinity of the pipe or open hole. The change in wave speed of the probe pulses as the HALF induced strain wave oscillation propagates through the formation, as a function of the induced strain, may be used to determine the nonlinear elastic parameters α, β, δ, and A of the pore pressure, from which the pore pressure may be determined in the region of the HALF wave.

Goodman, Harvey E.↗

Comparison of methods for the NMR measurement of motionally averaged dipolar couplings

Motionally averaged dipolar couplings are an important tool for understanding the complex dynamics of catalysts, polymers, and biomolecules. While there is a plethora of solid-state NMR pulse sequences available for their measurement, in can be difficult to gauge the methods’ strengths and weaknesses. In particular, there has not been a comprehensive comparison of their performance in natural abundance samples, where 1H homonuclear dipolar couplings are important and the use of large MAS rotors may be required for sensitivity reasons. In this work, we directly compared some of the more common methods for measuring C–H dipolar couplings in natural abundance samples using L-alanine (L-Ala) and the N-formyl-L-methionyl-L-leucyl-L-phenylalanine (fMLF) tripeptide as model systems. Here, we evaluated their performance in terms of accuracy, resolution, sensitivity, and ease of implementation. We found that, despite the presence of 1H homonuclear dipolar interactions, all methods, with the exception of REDOR, were able to yield the reasonable dipolar coupling strengths for both mobile and static moieties. Of these methods, PDLF provides the most convenient workflow and precision at the expense of low sensitivity. In low-sensitivity cases, MAS-PISEMA and DIPSHIFT appear to be the better options.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental methods for laboratory measurements of helium spectral line broadening in white dwarf photospheres

White Dwarf (WD) stars are the most common stellar remnant in the universe. WDs usually have a hydrogen or helium atmosphere, and helium WD (called DB) spectra can be used to solve outstanding problems in stellar and galactic evolution. DB origins, which are still a mystery, must be known to solve these problems. DB masses are crucial for discriminating between different proposed DB evolutionary hypotheses. Current DB mass determination methods deliver conflicting results. The spectroscopic mass determination method relies on line broadening models that have not been validated at DB atmosphere conditions. We performed helium benchmark experiments using the White Dwarf Photosphere Experiment (WDPE) platform at Sandia National Laboratories' Z-machine that aims to study He line broadening at DB conditions. Using hydrogen/helium mixture plasmas allows investigating the importance of He Stark and van der Waals broadening simultaneously. Accurate experimental data reduction methods are essential to test these line-broadening theories. In this paper, we present data calibration methods for these benchmark He line shape experiments. We give a detailed account of data processing, spectral power calibrations, and instrument broadening measurements. Uncertainties for each data calibration step are also derived. We demonstrate that our experiments meet all benchmark experiment accuracy requirements: WDPE wavelength uncertainties are <1 Å, spectral powers can be determined to within 15%, densities are accurate at the 20% level, and instrumental broadening can be measured with 20% accuracy. Fulfilling these stringent requirements enables WDPE experimental data to provide physically meaningful conclusions about line broadening at DB conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Impacts of engine lubrication oil-derived ash on soot oxidative reactivity on a catalytic gasoline particulate filter

Characterizing soot oxidation kinetics is crucial for understanding how gasoline particulate filters (GPFs) perform both in terms of filtration efficiency and pressure drop. The most common method for measuring soot oxidative reactivity is thermogravimetric analysis (TGA). Because TGA is an offline method, it may inaccurately predict how soot oxidizes on a GPF, especially if a catalytic washcoat is present that may enhance oxidation rates through surface interactions as the soot loads on the filter. In this work, a novel in-situ soot oxidative reactivity measurement method was developed. The method involved loading a catalytic GPF under high temperature conditions conducive to soot oxidation and measuring the filtration efficiency of 100 nm particles. A correlation was made between filtration efficiency and loaded soot mass on the filter to allow calculation of the soot oxidation rate. The method was evaluated in experiments using a 2.0 L gasoline direct injection (GDI) engine with three oils of varying additive packages, including an oil with a high zinc dialkyldithiophosphate (ZDDP) concentration, a non-additive, pure poly-alpha olefin (PAO) oil, and an oil with a high concentration of calcium sulfonate. Calculated specific soot oxidation rates ranged from ~0.06–0.6 min –1 and showed strong dependence on GPF inlet gas temperature and lubrication oil additive type. The results clearly demonstrated a catalytic effect of calcium-containing ash particles. Reactivity of soot produced by the engine running with the high calcium containing lubrication oil was increased. Similarly, the results indicated that the catalytic washcoat on the filter increased soot oxidation rates on-filter, especially at low soot loading. Conversely, the ZDDP oil additive exhibited a reactivity inhibiting effect, resulting in lower soot oxidation rates. Finally, this work represents the first known in-situ soot oxidative reactivity measurements on a GPF and elucidates the effect of lubrication oil additives and catalytic washcoat on oxidation rate.

42 ENGINEERING↗

Image processing methods for Rayleigh scattering measurements of diesel spray mixing at high repetition rate

This work describes the diagnostic implementation and image processing methods to quantitatively measure diesel spray mixing injected into a high-pressure, high-temperature environment. We used a high-repetition-rate pulse-burst laser developed in-house, a high-speed CMOS camera, and optimized the optical configuration to capture Rayleigh scattering images of the vaporized fuel jets inside a constant volume chamber. The experimental installation was modified to reduce reflections and flare levels to maximize the images’ signal-to-noise ratios by anti-reflection coatings on windows and surfaces, as well as series of optical baffles. Because of the specificities of the high-speed system, several image processing techniques had to be developed and implemented to provide quantitative fuel concentration measurements. We find that these methods involve various correction procedures such as camera linearity, laser intensity fluctuation, dynamic background flare, as well as beam-steering effects. Image inpainting was also applied to correct the Rayleigh scattering signal from large scatterers (e.g. particulates). The experiments demonstrate that applying planar laser Rayleigh scattering at high repetition rate to quantitatively resolve the mixing of fuel and ambient gases in diesel jets is challenging, but possible. The thorough analysis of the experimental uncertainty and comparisons to past data prove that such measurements can be accurate, whilst providing valuable information about the mixing processes of high-pressure diesel jets.

47 OTHER INSTRUMENTATION↗

Measurement of Beam Energy in the Fermilab&#x27;s Linac taken at the Transfer Line

Linac is the first machine in the accelerator chain at Fermilab where H$^{-}$ ions are accelerated from 35 keV to 401.5\,MeV and then injected into a synchronton known as Booster where they are stripped of their electrons to become protons. One of the tools used during tuning of the Linac extraction energy is two beam pickups known as Griffin Detectors. Our goal is to control the output energy using machine learning techniques to increase the reliability and quality of the beam delivered from Linac. The first step is to understand the data from the diagnostics to develop reliable and accurate energy measurement, and control methods before implementing machine learning techniques. Two methods of energy measurement were studied, and their results are compared. The first method was the time of flight measurement using Beam Position Monitors that provide beam phase measurement. The second method used the relation between beam transverse positions and dispersion values to calculate momentum variation. The results of these two measurement methods are found to be consistent.

43 PARTICLE ACCELERATORS↗

Estimation of the orientation of stress in the Earth’s crust without earthquake or borehole data

Abstract Mechanical stress acting in the Earth’s crust is a fundamental property that is important for a wide range of scientific and engineering applications. The orientation of maximum horizontal compressive stress can be estimated by inverting earthquake source mechanisms and measured directly from borehole-based measurements, but large regions of the continents have few or no observations. Here we present an approach to determine the orientation of maximum horizontal compressive stress by measuring stress-induced anisotropy of nonlinear susceptibility, which is the derivative of elastic modulus with respect to strain. Laboratory and Earth experiments show that nonlinear susceptibility is azimuthally dependent in an anisotropic stress field and is maximum in the orientation of maximum horizontal compressive stress. We observe this behavior in the Earth—in Oklahoma and New Mexico, U.S.A, where maximum nonlinear susceptibility coincides with the orientation of maximum horizontal compressive stress measured using traditional methods. Our measurements use empirical Green’s functions and solid-earth tides and can be applied at different temporal and spatial scales.

58 GEOSCIENCES↗

Near-zero-field magnetoresistance measurements: A simple method to track atomic-scale defects involved in metal-oxide-semiconductor device reliability

We demonstrate the ability of a relatively new analytical technique, near-zero-field magnetoresistance (NZFMR), to track atomic-scale phenomena involved in the high-field stressing damage of fully processed Si metal-oxide-semiconductor field-effect transistors. We show that the technique is sensitive to both the Pb0 and Pb1 dangling bond centers and that the presence of both centers can be inferred through NZFMR via hyperfine interactions with the central 29Si atoms of the dangling bonds. The NZFMR results also provide evidence for the redistribution of mobile hydrogen atoms at the Si/SiO2 interface and also a potential change in the average dipolar coupling constant between electrons in neighboring defects. This work shows that NZFMR offers significant analytical power for studying technologically relevant semiconductor device reliability problems and has advantages in experimental simplicity over comparable techniques.

Moxim, Stephen J. (ORCID:0000000309659904)↗