Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

A Short-lived Three-Belt Structure for sub-MeV Electrons in the Van Allen Belts: Time Scale and Energy Dependence

In this study we focus on the radiation belt dynamics driven by the geomagnetic storms during September 2017. Besides the long-lasting three-belt structures of ultrarelativistic electrons (>2 MeV, existing for tens of days), which has been studied intensively during the Van Allen Probe era, it is found that magnetospheric electrons of hundreds of keVs can also have three-belt structures at similar L extent during storm time. Measurements of 500–800 keV electrons from MagEIS instrument onboard Van Allen Probes show double-peaked (L = 3.5 and 4.5, respectively) flux-versus-L-shell profile in the outer belt, which lasted for 2–3 days. During the time interval of such transient three-belt structure, the energy-versus-L spectrogram shows novel distributions differing from both “S-shaped” and “V-shaped” spectrograms reported previously. Such peculiar distribution also illustrates the energy-dependent occurrence of the three-belt profile. Furthermore, the gradual formation of “reversed energy spectrum” at L ~ 3.5 also indicates that hiss scattering inside the plasmapause contributed to the fast decay of sub-MeV remnant belt.

79 ASTRONOMY AND ASTROPHYSICS↗

Differentiating multi-MeV, multi-ion spectra with CR-39 solid-state nuclear track detectors

The development of high intensity petawatt lasers has created new possibilities for ion acceleration and nuclear fusion using solid targets. In such laser-matter interaction, multiple ion species are accelerated with broad spectra up to hundreds of MeV. To measure ion yields and for species identification, CR-39 solid-state nuclear track detectors are frequently used. However, these detectors are limited in their applicability for multi-ion spectra differentiation as standard image recognition algorithms can lead to a misinterpretation of data, there is no unique relation between track diameter and particle energy, and there are overlapping pit diameter relationships for multiple particle species. In this report, we address these issues by first developing an algorithm to overcome user bias during image processing. Second, we use calibration of the detector response for protons, carbon and helium ions (alpha particles) from 0.1 to above 10 MeV and measurements of statistical energy loss fluctuations in a forward-fitting procedure utilizing multiple, differently filtered CR-39, altogether enabling high-sensitivity, multi-species particle spectroscopy. To validate this capability, we show that inferred CR-39 spectra match Thomson parabola ion spectrometer data from the same experiment. Filtered CR-39 spectrometers were used to detect, within a background of ~ 2 × 10 11 sr -1 J -1 protons and carbons, (1.3 ± 0.7) × 10 8 sr -1 J -1 alpha particles from laser-driven proton-boron fusion reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

A multi-MeV alpha particle source via proton-boron fusion driven by a 10-GW tabletop laser

Nuclear fusion between protons and boron-11 nuclei has undergone a revival of interest thanks to the rapid progress in pulsed laser technology. Potential applications of such reaction range from controlled nuclear fusion to radiobiology and cancer therapy. A laser-driven fusion approach consists in the interaction of high-power, high-intensity pulses with H- and B-rich targets. We report on an experiment exploiting proton-boron fusion in CN-BN targets to obtain high-energy alpha particle beams (up to 5 MeV) using a very compact approach and a tabletop laser system with a peak power of ~10 GW, which can operate at high-repetition rate (up to 1 kHz). The secondary resonance in the cross section of proton-boron fusion (~150 keV in the center-of-mass frame) is exploited using a laser-based approach. The generated alpha particles are characterized in terms of energy, flux, and angular distribution using solid-state nuclear-track detectors, demonstrating a flux of ~10 5 particles per second at 10 Hz, and ~10 6 per second at 1 kHz. Hydrodynamic and particle-in-cell numerical simulations support our experimental findings. Potential impact of our approach on future spread of ultra-compact, multi-MeV alpha particle sources driven by moderate intensity (10 16 -10 17 W/cm 2 ) laser pulses is anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-repetition-rate, multi-MeV deuteron acceleration from converging heavy water microjets at laser intensities of 10 21 W/cm 2

Herein we demonstrate high repetition-rate deuteron acceleration by irradiating a continuously flowing, ambient temperature liquid heavy water jet with the high-intensity ALEPH laser. The laser delivered up to 5.5 J (120 TW, 1.2 × 10 21 W/cm 2 ) laser energy on target at 0.5 Hz. A high repetition-rate Thomson parabola spectrometer measured the deuteron beam energy spectra on each shot for 60 sequential shots (two minutes). Peak fluxes of 5 x 10 10 deuterons/sr/pulse, corresponding to an average flux of 1.5 x 10 12 deuterons/sr/min, were demonstrated with deuteron energies reaching up to 4.4 MeV. High shot-to-shot stability is observed up to 40%–50% of the maximum deuteron energy. These deuteron beams are suited for fast neutron production through deuteron breakup in a converter yielding energies similar to deuteron–deuteron (D–D, 2.45 MeV) fusion reactions of importance for material damage studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

Scalings of laser-driven MeV electron sources with relativistic multi-picosecond laser pulses

We investigate the generation of MeV electrons in relativistic multi-picosecond laser–solid interactions, using two-dimensional particle-in-cell simulations. Scanning a parameter space of intensities from 10 18 to 10 20 W/cm 2 and pulse durations between 100 fs and 10 ps, we discuss scalings of the effective hot electron temperature and MeV electron dose relevant to applications, as well as the direct laser acceleration mechanism that drives electrons to energies much higher than the ponderomotive potential of the laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and scaling of MeV x-ray radiography at NIF-ARC

We investigate the generation of MeV x-rays using the Advanced Radiography Capability laser system at the National Ignition Facility using 1, 10, and 38 ps pulse durations, with laser energies reaching up to 4 kJ and using compound parabolic concentrators. Hydrodynamic simulations using up-to-date measurements of the contrast of the ARC laser are conducted, allowing us to employ an electron scaling model that incorporates scale length and pulse duration, which aligns closely with the observed temperature distributions. Comparable x-ray sources, in terms of dose, are generated when using a 10 ps pulse duration with 2.4 kJ at ∼1.9 ± 0.4 × 10 18 W/cm 2 and when using a 38 ps pulse duration with 4 kJ at 9.9 ± 0.4 × 10 17 W/cm 2 , both achieving ∼16 rad in air at 1 m for x-ray energies > 0.5 MeV. Radiographs performed on the laser “line-of-sight” show significant improvements in image quality than radiographs performed at 65 degrees to the laser axis. We verify the radiography performance using Monte Carlo Simulations.

Physics - Plasma physics↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-space sensitivity (weight functions) of 3 MeV proton diagnostics

Abstract The weight function W ( X ) is a diagnostic sensitivity to phase-space variables X that relates the measured signal C to the distribution function F ( X ) through the equation C = ∫ W ( X ) F ( X ) d X . In the present work, an algorithm to calculate W for a diagnostic that measures 3 MeV protons produced in d(d,p)t fusion reactions between a fast ion and a thermal deuteron is developed. The emitted protons escape the tokamak on curved orbits and are detected. These curved orbits constitute effective diagnostic ‘sightlines’. The presented algorithm accounts for the complications associated with these curved sightlines. An initial calculation of time-reversed proton orbits computes effective solid angles and sightlines for the relevant range of incident proton velocity vectors. These precomputed orbits are then used within the framework of FIDASIM (2020 Plasma Phys. Cont. Fusion 62 105008) to calculate the reactivity averaged over the thermal distribution of the ‘target’ deuterons and the probability that a fast ion of specified energy and pitch has a gyroangle that is consistent with the kinematic equations along each of the sightlines. Comparisons with analytic formulas and with independent calculations for the Mega Amp Spherical Tokamak 3 MeV proton diagnostic verify the algorithm.

Physics↗

Exploring the MeV sky with a combined coded mask and Compton telescope: the Galactic Explorer with a Coded aperture mask Compton telescope (GECCO)

The sky at MeV energies is currently poorly explored. Here we present an innovative mission concept that builds upon the heritage of past and current missions improving the sensitivity and, very importantly, the angular resolution. This consists in combining a Compton telescope and a coded-mask telescope. We delineate the motivation for such a concept and we define the scientific goals for such a mission. The Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO) is a novel concept for a next-generation telescope covering hard X-ray and soft gamma-ray energies. The potential and importance of this approach that bridges the observational gap in the MeV energy range are presented. With the unprecedented angular resolution of the coded mask telescope combined with the sensitive Compton telescope, a mission such as GECCO can disentangle the discrete sources from the truly diffuse emission. Individual Galactic and extragalactic sources are detected. This also allows to understand the gamma-ray Galactic center excess and the Fermi Bubbles, and to trace the low-energy cosmic rays, and their propagation in the Galaxy. Nuclear and annihilation lines are spatially and spectrally resolved from the continuum emission and from sources, addressing the role of low-energy cosmic rays in star formation and galaxy evolution, the origin of the 511 keV positron line, fundamental physics, and the chemical enrichment in the Galaxy. Such an instrument also detects explosive transient gamma-ray sources, which, in turn, enables identifying and studying the astrophysical objects that produce gravitational waves and neutrinos in a multi-messenger context. By looking at a poorly explored energy band it also allows discoveries of new astrophysical phenomena.

79 ASTRONOMY AND ASTROPHYSICS↗

The meV-resolved Inelastic X-ray Scattering Beamline at NSLS-II: Design and Performance

The ultrahigh resolution inelastic X-ray scattering (IXS) beamline at NSLS-II is designed and built to achieve sub-meV resolution at a moderate energy of 9.13 keV for IXS experiments with high momentum resolution and high spectral contrast. The key instrument is a novel spectrometer featuring a new type of analyzer optics, which combines post-sample collimation with angular dispersive crystal optics. As the first user instrument of its kind, the spectrometer has demonstrated unique research capabilities in exploring low momentum transfer (Q), THz dynamics in soft material systems characterized by mesoscopic heterogeneity and complexity, such as liquid crystals and bio-membranes. Ongoing efforts to improve performance since the start of user operations have resulted in a state-of-the-art energy resolution in routine operations of less than 1.4 meV, with sharp Gaussian-like tails, making it a premier IXS spectrometer for studying the dynamics of soft materials, while also delivering competitive performance for investigating phonon dynamics in hard condensed matter systems, including a broad range of quantum materials.

43 PARTICLE ACCELERATORS↗

Time-of-flight methodologies with large-area diamond detectors for the effectively characterization of tens MeV protons

A novel detector based on a polycrystalline diamond sensor is here employed in an advanced time-of-flight scheme for the characterization of energetic ions accelerated during laser-matter interactions. The optimization of the detector and of the advanced TOF methodology allow to obtain signals characterized by high signal-to-noise ratio and high dynamic range even in the most challenging experimental environments, where the interaction of high-intensity laser pulses with matter leads to effective ion acceleration, but also to the generation of strong Electromagnetic Pulses (EMPs) with intensities up to the MV/m order. These are known to be a serious threat for the fielded diagnostic systems. Here we report on the measurement performed with the PW-class laser system Vega 3 at CLPU (~30 J energy, ~10 21 W/cm 2 intensity, ~30 fs pulses) irradiating solid targets, where both tens of MeV ions and intense EMP fields were generated. The data were analyzed to retrieve a calibrated proton spectrum and in particular we focus on the analysis of the most energetic portion (E > 5.8 MeV) of the spectrum showing a procedure to deal with the intrinsic lower sensitivity of the detector in the mentioned spectral-range.

47 OTHER INSTRUMENTATION↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Measurement of magnetic dipole strength in 40 Ar between 9.3 and 10.3 MeV excitation energy and impact on neutral current neutrino interaction

The magnetic dipole strength 𝐵⁡(𝑀⁢1 ↑) of 40 Ar was measured in the excitation energy range between 9.3 and 10.3 MeV. The nuclear resonance fluorescence technique was used with monoenergetic, linearly polarized incident photon beams. The new data increase the known 𝐵⁡(𝑀⁢1 ↑) strength in this important excitation energy range by a factor of 2, resulting in an equivalent increase of the calculated neutral current neutrino cross section of 40 Ar . This observation is of special interest for liquid-argon (LAr)-based neutrino detectors. 𝐵⁡(𝑀⁢1 ↑) strength has not been found between 10.3 and 11.7 MeV excitation energy. In conclusion, with the new data, a more reliable detection capability of the large Deep Underground Neutrino Experiment LAr detectors can be derived for potential core-collapse supernova neutrinos via the neutral current interaction.

Energy levels↗

Measurement of the 75 As ⁢(𝑛, 2⁢𝑛) cross section at 14.1 MeV at the National Ignition Facility

Here, a new measurement of the 75 As (𝑛, 2⁢𝑛) measurement was performed using the 14.1 MeV neutron pulse produced by fusion experiments at the National Ignition Facility (NIF). The target material consisted of GaAs foils encapsulated in aluminum irradiation containers, along with Au monitor foils, and positioned in the NIF chamber during high neutron yield shots. After irradiation, the GaAs and Au foils were counted with high purity germanium detectors to assess the production of (𝑛, 2⁢𝑛) activation products to determine the flux and the cross section of interest. The measured cross section was 966 ± 71 mb at 14.1 ± 0.37 MeV. This work provides a proof of concept for a platform for performing “ride-along” cross section measurements at NIF to contribute to existing nuclear data as well as measure new cross sections in the future.

and nuclear chemistry↗

Measurement of the Li 7 ( γ , t ) He 4 ground-state cross section between E γ = 4.4 and 10 MeV

Here, the Li 7 ( γ , t ) He 4 ground state cross section was measured for the first time using monoenergetic γ rays with energies between 4.4 and 10 MeV at the High Intensity Gamma-ray Source. The reaction is important for the primordial Li problem and for testing our understanding of the mirror α -capture reactions H 3 ( α , γ ) Li 7 and He 3 ( α , γ ) Be 7 . Although over the last 30 years most measurements of the H 3 ( α , γ ) Li 7 reaction have concentrated in an energy range below E γ = 3.65 MeV, measurements at higher energies could potentially restrict the extrapolation to astrophysically important energies. The experimental arrangement for measuring the Li 7 ( γ , t ) He 4 reaction included a large-area silicon detector array and several beam characterization instruments. The experimental astrophysical S factor of H 3 ( α , γ ) calculated from the present data was fitted using the R -matrix formalism. The results are in disagreement with previous experimental measurements in the same energy range but the extrapolated S factor agrees with the potential model calculation and lower energy experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗