M. mazei glutamine synthetase and glutamine synthetase-GlnK1 structures reveal enzyme regulation by oligomer modulation

Glutamine synthetases (GS) play central roles in cellular nitrogen assimilation. Although GS active-site formation requires the oligomerization of just two GS subunits, all GS form large, multi-oligomeric machines. Here we describe a structural dissection of the archaeal Methanosarcina mazei ( Mm ) GS and its regulation. We show that Mm GS forms unstable dodecamers. Strikingly, we show this Mm GS oligomerization property is leveraged for a unique mode of regulation whereby labile Mm GS hexamers are stabilized by binding the nitrogen regulatory protein, GlnK1. Our GS-GlnK1 structure shows that GlnK1 functions as molecular glue to affix GS hexamers together, stabilizing formation of GS active-sites. These data, therefore, reveal the structural basis for a unique form of enzyme regulation by oligomer modulation.

59 BASIC BIOLOGICAL SCIENCES↗

Origin of biogeographically distinct ecotypes during laboratory evolution

Resource partitioning is central to the incredible productivity of microbial communities, including gigatons in annual methane emissions through syntrophic interactions. Previous work revealed how a sulfate reducer (Desulfovibrio vulgaris, Dv) and a methanogen (Methanococcus maripaludis, Mm) underwent evolutionary diversification in a planktonic context, improving stability, cooperativity, and productivity within 300-1000 generations. Here, we show that mutations in just 15 Dv and 7 Mm genes within a minimal assemblage of this evolved community gave rise to co-existing ecotypes that were spatially enriched within a few days of culturing in a fluidized bed reactor. The spatially segregated communities partitioned resources in the simulated subsurface environment, with greater lactate utilization by attached Dv but partial utilization of resulting H 2 by low affinity hydrogenases of Mm in the same phase. The unutilized H 2 was scavenged by high affinity hydrogenases of planktonic Mm, producing copious amounts of methane. Our findings show how a few mutations can drive resource partitioning amongst niche-differentiated ecotypes, whose interplay synergistically improves productivity of the entire mutualistic community.

59 BASIC BIOLOGICAL SCIENCES↗

A highly-selective chloride microelectrode based on a mercuracarborand anion carrier

The chloride gradient plays an important role in regulating cell volume, membrane potential, pH, secretion, and the reversal potential of inhibitory glycine and GABAA receptors. Measurement of intracellular chloride activity, $a^i_{Cl}$, using liquid membrane ion-selective microelectrodes (ISM), however, has been limited by the physiochemical properties of Cl - ionophores which have caused poor stability, drift, sluggish response times, and interference from other biologically relevant anions. Most importantly, intracellular $HCO^-_3$ may be up to 4 times more abundant than Cl - (e.g. skeletal muscle) which places severe constraints on the required selectivity of a Cl - - sensing ISM. Previously, a sensitive and highly-selective Cl - sensor was developed in a polymeric membrane electrode using a trinuclear Hg(II) complex containing carborane-based ligands, [9]-mercuracarborand-3, or MC3 for short. Here, we have adapted the use of the MC3 anion carrier in a liquid membrane ion-selective microelectrode and show the MC3-ISM has a linear Nernstian response over a wide range of a Cl (0.1 mM to 100 mM), is highly selective for Cl - over other biological anions or inhibitors of Cl - transport, and has a 10% to 90% settling time of 3 sec. Importantly, over the physiological range of aCl (1 mM to 100 mM) the potentiometric response of the MC3-ISM is insensitive to $HCO^-_3$ or changes in pH. Finally, we demonstrate the biological application of an MC3-ISM by measuring intracellular aCl, and the response to an external Cl-free challenge, for an isolated skeletal muscle fiber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data driven pathway analysis and forecast of global warming and sea level rise

Climate change is a critical issue of our time, and its causes, pathways, and forecasts remain a topic of broader discussion. In this paper, we present a novel data driven pathway analysis framework to identify the key processes behind mean global temperature and sea level rise, and to forecast the magnitude of their increase from the present to 2100. Based on historical data and dynamic statistical modeling alone, we have established the causal pathways that connect increasing greenhouse gas emissions to increasing global mean temperature and sea level, with its intermediate links encompassing humidity, sea ice coverage, and glacier mass, but not for sunspot numbers. Our results indicate that if no action is taken to curb anthropogenic greenhouse gas emissions, the global average temperature would rise to an estimated 3.28 °C (2.46–4.10 °C) above its pre-industrial level while the global sea level would be an estimated 573 mm (474–671 mm) above its 2021 mean by 2100. However, if countries adhere to the greenhouse gas emission regulations outlined in the 2021 United Nations Conference on Climate Change (COP26), the rise in global temperature would lessen to an average increase of 1.88 °C (1.43–2.33 °C) above its pre-industrial level, albeit still higher than the targeted 1.5 °C, while the sea level increase would reduce to 449 mm (389–509 mm) above its 2021 mean by 2100.

54 ENVIRONMENTAL SCIENCES↗

Ultra-stable and poison tolerant oxygen evolution activity enabled by surface In 2 O 3- x (OH) y of Co 3 In 2 S 2 large single crystals

Water is an earth-abundant source for clean hydrogen production via electrochemical water electrolysis (WE). However, the surface poisoning that occurs in aqueous electrolytes drastically deactivates the electrocatalytic performance of electrodes. Here, in this study, we report electrochemically formed In 2 O 3-x (OH) y on the surface of a large (1–1.5 mm long, 0.5–0.6 mm wide and 0.3–0.5 mm thick) single crystal of Weyl semimetal Co 3 In 2 S 2 (Co 3 In 2 S 2 /In 2 O 3-x (OH) y ) as an ultra-stable and poison tolerant electrode for the oxygen evolution reaction (OER) in 1 M KOH, addressing a bottleneck in WE. The OER activity of the powder form of Co 3 In 2 S 2 is limited by its aerophilic nature. Remarkably, the single-crystal electrodes maintained their high activity for a continuous operational period of 5 h in 1 M KOH electrolyte with/without 10 mM strong surface-poisoning ligands i.e., potassium cyanide, bipyridine, and ethylenediaminetetraacetate disodium salt. The electrodes exhibited stable OER activity for 1000 h at 100 mA cm -2 (1.73 V vs. RHE). The temperature-dependent OER polarization curves (10–70 °C) unambiguously revealed surface poisoning through the suppression of precatalytic Co-redox peaks on the bipyridine poisoned electrode, which led to the stabilization of surface Co-sites. The X-ray photoelectron spectroscopy analyses of pristine, poisoned and post-electrocatalytic single-crystal Co 3 In 2 S 2 electrodes revealed the existence of an In 2 O 3-x (OH) y surface phase, which could be the potential heterostructure for the origin of ultra-stable and poison tolerant OER activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Event Horizon Telescope imaging of the archetypal blazar 3C 279 at an extreme 20 microarcsecond resolution

3C 279 is an archetypal blazar with a prominent radio jet that show broadband flux density variability across the entire electromagnetic spectrum. We use an ultra-high angular resolution technique – global Very Long Baseline Interferometry (VLBI) at 1.3 mm (230 GHz) – to resolve the innermost jet of 3C 279 in order to study its fine-scale morphology close to the jet base where highly variable γ-ray emission is thought to originate, according to various models. The source was observed during four days in April 2017 with the Event Horizon Telescope at 230 GHz, including the phased Atacama Large Millimeter/submillimeter Array (ALMA), at an angular resolution of ∼20 μas (at a redshift of z = 0.536 this corresponds to ∼0.13 pc ∼ 1700 Schwarzschild radii with a black hole mass MBH = 8 × 108 M⊙). Imaging and model-fitting techniques were applied to the data to parameterize the fine-scale source structure and its variation. We find a multicomponent inner jet morphology with the northernmost component elongated perpendicular to the direction of the jet, as imaged at longer wavelengths. The elongated nuclear structure is consistent on all four observing days and across different imaging methods and model-fitting techniques, and therefore appears robust. Owing to its compactness and brightness, we associate the northern nuclear structure as the VLBI “core”. This morphology can be interpreted as either a broad resolved jet base or a spatially bent jet. We also find significant day-to-day variations in the closure phases, which appear most pronounced on the triangles with the longest baselines. Our analysis shows that this variation is related to a systematic change of the source structure. Two inner jet components move non-radially at apparent speeds of ∼15 c and ∼20 c (∼1.3 and ∼1.7 μas day−1, respectively), which more strongly supports the scenario of traveling shocks or instabilities in a bent, possibly rotating jet. The observed apparent speeds are also coincident with the 3C 279 large-scale jet kinematics observed at longer (cm) wavelengths, suggesting no significant jet acceleration between the 1.3 mm core and the outer jet. The intrinsic brightness temperature of the jet components are ≲1010 K, a magnitude or more lower than typical values seen at ≥7 mm wavelengths. The low brightness temperature and morphological complexity suggest that the core region of 3C 279 becomes optically thin at short (mm) wavelengths.Key words: galaxies: active / galaxies: jets / galaxies: individual: 3C 279 / techniques: interferometric⋆ The data are only available at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/cat/J/A+A/640/A69 and at https://eventhorizontelescope.org/for-astronomers/data⋆⋆ Deceased.

79 ASTRONOMY AND ASTROPHYSICS↗

Candidate cosmic filament in the GJ526 field, mapped with the NIKA2 camera

Distinctive large-scale structures have been identified in the spatial distribution of optical galaxies up to redshift z ~ 1. In the more distant universe, the relationship between the dust-obscured population of star-forming galaxies observed at millimetre wavelengths and the network of cosmic filaments of dark matter apparent in all cosmological hydrodynamical simulations is still under study. Using the NIKA2 dual-band millimetre camera, we mapped a field of ~90 arcmin 2 in the direction of the star GJ526 simultaneously in its 1.15-mm and 2.0-mm continuum wavebands to investigate the nature of the quasi-alignment of five sources found ten years earlier with the MAMBO camera at 1.2 mm. We find that these sources are not clumps of a circumstellar debris disc around this star as initially hypothesized. Rather, they must be dust-obscured star-forming galaxies, or sub-millimetre galaxies (SMGs), in the distant background. The new NIKA2 map at 1.15 mm reveals a total of seven SMGs distributed in projection on the sky along a filament-like structure crossing the whole observed field. Furthermore, we show that the NIKA2 and supplemental Herschel photometric data are compatible with a model of the spectral energy distributions (SEDs) of these sources when a common redshift of 2.5 and typical values of the dust parameters for SMGs are adopted. Hence, we speculate that these SMGs might be located in a filament of the distant ‘cosmic web’. The length of this candidate cosmic filament crossing the whole map is at least 4 cMpc (comoving), and the separations between sources are between 0.25 cMpc and 1.25 cMpc at this redshift, in line with expectations from cosmological simulations. Nonetheless, further observations to determine the precise spectroscopic redshifts of these sources are required to definitively support this hypothesis of SMGs embedded in a cosmic filament of dark matter.

79 ASTRONOMY AND ASTROPHYSICS↗

Cryogenic operation of planar ultrananocrystalline diamond field emission source in SRF injector

Here, we report a demonstration of electron beam generation in a superconducting radio frequency (SRF) Teraelectronvolt Energy Superconducting Linear Accelerator 1.3 GHz gun equipped with a field emission cathode and operated at 2 K. The cathode is a submicrometer film of nitrogen-incorporated ultrananocrystalline diamond [(N)UNCD] deposited atop a Nb RRR300 cathode plug that is 4 mm in diameter. Measurements of the output current showed that it increased exponentially as a function of the gun gradient. Our results demonstrate a feasible path toward simplified fully cryogenic SRF injector technology. At a maximal gradient of 0.9 MV/m, a current density of 22 μA/cm2 was obtained [calculated as a 2.75 μA current over the total cathode surface area of π(2 mm)2]. One important finding is that the electron emitter made of (N)UNCD, a material long been known as a highly efficient field emission material, demonstrated a record low turn-on gradient of 0.6 MV/m. A hypothesis explaining this behavior is proposed.

43 PARTICLE ACCELERATORS↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

A study of explosive-induced fracture in polymethyl methacrylate (PMMA)

The fracture response of geologic materials is of interest for applications, including geothermal energy harnessing and containment of underground explosions. To better understand the explosively induced fracture response of geomaterials, polymethyl methacrylate (PMMA) was used as a transparent rock surrogate to allow imaging of internal shock propagation and fracture growth processes. Experiments were conducted using high-speed shadowgraphy and photon Doppler velocimetry (PDV), which were compared to numerical simulations. Experiments measured fractures produced in 304.8mm × 304.8mm × 304.8mm PMMA cubes with two simultaneously initiated detonators. The cubes were subjected to varying amounts and directions of externally applied uniaxial stresses, including no stress, 2 MPa stress, and 20 MPa stress. The fracture radius as a function of time was extracted from the high-speed videos. Post-test images of the PMMA cubes aided in the determination of three-dimensional effects not directly imaged by the cameras. The surface velocity history and the shock response captured in PDV and the high-speed videos were compared to the simulated explosive-induced shock response. The simulation results indicate that the shock drives the fracture for the first 20 μs corresponding to a fracture radius of approximately 15 mm in the experiments. The gas-driven fracture extent was estimated analytically using an equilibrium stress distribution calculated after the shock wave propagation through the sample. Reduction in the gas pressure due to the leakage of the explosive products through the crack as a function of time was accounted for. In conclusion, the estimated fracture lengths were in agreement with the experimentally observed fracture lengths.

15 GEOTHERMAL ENERGY↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Nozzle geometry optimization for high-current aluminum ion beam acceleration via direct plasma injection scheme

We report the generation of a record aluminum ion beam current exceeding 58 mA at the Al 11+ charge state, accelerated to an energy of 5.5 MeV using the direct plasma injection scheme, which integrates a laser ion source (LIS) with a radio frequency quadrupole (RFQ) accelerator. The effect of nozzle geometry on beam extraction was systematically investigated using 8 and 12 mm tapered designs and an 18 mm cylindrical configuration. The 18 mm nozzle achieved the highest Al 11+ beam current, while the 12 mm aperture provided a favorable balance between beam intensity and current density. Beam extraction simulations confirmed effective RFQ matching across multiple charge states, and solenoidal field tuning further enhanced plasma collimation. This work not only establishes a new benchmark for high-current ion beam generation but also provides a fundamental understanding of plasma–beam interface dynamics crucial for the next generation of high-intensity particle accelerators, particularly those employing LIS-RFQ systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Welch Method and Bootstrapping Applied to Subcritical Gamma Noise

We measured the prompt neutron decay constant 𝛼 of the CROCUS zero-power reactor at the Swiss Federal Institute of Technology Lausanne using cross-power spectral density (CPSD) analysis of gamma-gamma correlations from two trans-stilbene organic scintillators positioned near the reactor core. We measured critical and subcritical states, with water levels ranging from 960 mm (critical) to 800 mm (𝜌=−1.4 $ subcritical). Our analysis used the Welch method, dividing signal segments for fast Fourier transform (FFT) frequency analysis and applying bootstrapping uncertainty quantification that uses Welch-defined segments. Results demonstrated a clear increase in the measured 𝛼 as reactor reactivity decreased, distinguishing critical from subcritical conditions. At the 960-mm critical level, 𝛼 was estimated at 155.9 ± 0.7 s −1 , and for the 800-mm subcritical level, 𝛼 increased significantly to 367.3 ± 6.9 s –1 . A linear regression of subcritical states yielded a critical estimate of 154.0 ± 3.1 s –1 , aligning with the static 𝛼 estimate at critical. The bootstrapping method produced normally distributed 𝛼 estimates, confirming data consistency. The gamma CPSD 𝛼 estimates clearly distinguish reactor states and improve monitoring of zero-power reactors. The future deployment of modular and microreactors as potential candidates for noise analysis is demonstrated in CROCUS, particularly zero-power mock-ups of new designs. The improvement of noise analysis in the subcritical domain from this work will support experimental data for reactor deployment and procedure.

CROCUS↗

Numerical simulation of an atmospheric pressure plasma jet with coaxial shielding gas

A two-dimensional ( r, z ) numerical simulation of the discharge characteristics of an atmospheric pressure plasma jet (APPJ), with coaxial shielding gas, was performed. The helium working gas flowed in a central capillary tube, engulfing a needle electrode powered by 13.7 MHz radio frequency sinusoidal voltage. The N 2 shielding gas flowed in the annular space of a coaxial tube. These gases emerged, in laminar flow, in a 78%N 2 -21%O 2 -1%Ar dry air ambient. The characteristics of the APPJ with shielding gas were compared to those of the APPJ without shielding gas. The nitrogen shielding gas hindered the diffusion of oxygen and argon from the ambient air into the helium jet. With the shielding gas present, more nitrogen penetrated into the helium core, causing a shorter plasma ‘plume’. The flow rates of the working and shielding gas, critically affected the gas temperature, and in turn the discharge characteristics. For a He flow of 2 standard liters per minute (slm), switching on the nitrogen shielding gas flow (at 4.5 slm) reduced the on-axis O 2 and Ar mole fractions from 3.9 × 10 - 4 to 6.8 × 10 - 5 and from 1.9 × 10 - 5 to 3.3 × 10 - 6 , respectively, at an axial distance of 3 mm downstream of the nozzle. The radial profiles of the mole fractions of the ambient gases were monotonically and strongly decreasing towards the system axis, for short axial distances from the nozzle (~1 mm), but became progressively flatter at longer distances from the nozzle (3 mm and 5 mm). Simulation predictions captured the salient features of experimental data of ambient species mole fractions in the plasma jet, and the 706 nm optical emission intensity profiles of the He 3 3 S excited state.

Physics↗

Development and performance of a 2.9 Tesla dipole magnet using high-temperature superconducting CORC® wires

Although the high-temperature superconducting (HTS) REBa 2 Cu 3 O x (REBCO, RE-rare earth elements) material has a strong potential to enable dipole magnetic fields above 20 T in future circular particle colliders, the magnet and conductor technology needs to be developed. As part of an ongoing development to address this need, here we report on our CORC® canted cosθ magnet called C2 with a target dipole field of 3 T in a 65 mm aperture. The magnet was wound with 70 m of 3.8 mm diameter CORC® wire on machined metal mandrels. The wire had 30 commercial REBCO tapes from SuperPower Inc. each 2 mm wide with a 30 µm thick substrate. The magnet generated a peak dipole field of 2.91 T at 6.290 kA, 4.2 K. The magnet could be consistently driven into the flux-flow regime with reproducible voltage rise at an engineering current density between 400-550 A mm -2 , allowing reliable quench detection and magnet protection. The C2 magnet represents another successful step towards the development of high-field accelerator magnet and CORC® conductor technologies. The test results highlighted two development needs: continue improving the performance and flexibility of CORC® wires and develop the capability to identify locations of first onset of flux-flow voltage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and performance characterisation of the HAPG von Hámos Spectrometer at the High Energy Density Instrument of the European XFEL

The von Hámos spectrometer setup at the HED instrument of the European XFEL is described in detail. The spectrometer is designed to be operated primarily between 5 and 15 keV to complement the operating photon energy range of the HED instrument. Four Highly Annealed Pyrolitic Graphite (HAPG) crystals are characterised with thicknesses of 40 μm or 100 μm and radius-of-curvature 50 mm or 80 mm, in conjunction with either an ePix100 or Jungfrau detector. The achieved resolution with the 50 mm crystals, operated between 6.5 and 9 keV, matches that reported previously: ~8 eV for a thickness of 40 μm, whereas, with an 80 mm crystal of thickness 40 μm, the resolution exceeds that expected. Namely, a resolution of 2 eV is demonstrated between 5–6 keV implying a resolving power of 2800. Therefore, we posit that flatter HAPG crystals, with their high reflectivity and improved resolving power, are a powerful tool for hard x-ray scattering and emission experiments allowing unprecedented measurements of collective scattering in a single shot.

47 OTHER INSTRUMENTATION↗

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of the wavelength-shifting fiber upgrade for the Mu2e cosmic-ray veto detector

The Cosmic-Ray Veto detector for the muon-to-electron conversion experiment at Fermilab consists of four plastic scintillating counter layers read out by silicon photo-multipliers through embedded wavelength-shifting fibers. In order to increase the light yield in the most critical regions of the Cosmic-Ray Veto detector for improved background rejection, a 1.8 mm diameter fiber is being used in many of the detector's critical modules instead of the previously planned 1.4 mm diameter fiber. This paper reports the testing procedure and light properties of thirty-four 1.8 mm fiber spools, with measurements performed using a custom-built scanner. We compare these new results with previously published data from the 1.4 mm diameter fiber used for regions of the cosmic-ray veto where the increased light yield is not required. In addition, measurements of fiber aging were performed.