Analysis of the radiation patterns of reflector antennas

The development and application of a numerical technique for rapid calculation of the far-field radiation patterns of a reflector antenna from either a measured or computed feed pattern are reported. The reflector is defined by the intersection of a cone with any surface of revolution or an offset sector of any surface of revolution. The feed is assumed to be linearly polarized and can have an arbitrary location. Both the copolarized and the cross-polarized reflector radiation patterns are computed. Calculations using the technique compare closely with measured radiation patterns of a waveguide-fed offset parabolic reflector. Unique features of this technique are freedom from restrictive feed assumptions and the numerical methods used in preparing the aperture-plane electric-field data for integration.

Kauffman, J. F.↗

Bidirectional reflectances of three soil surfaces and their characterization through model inversion

Spectral bidirectional reflectances were measured over three natural soil sites using a specially designed radiometer called the Parabola. Two of the sites were bare soils, and the third had a sparse cover of desert scrub. The reflectances were strongly non-Lambertian for all three surfaces, but with markedly different patterns. The measured data were fitted with a quasi-physical reflectance model in which the surface backscattering and forwardscattering are separately formulated. A soil reflectance characterization was obtained by assessing the contributions of the forward, backward, and Lambertian components. This three-parameter characterization produced a satisfactory fit to the measured reflectances and appears promising as a basis for soils categorization.

Deering, D. W.↗

Millimeter-wave double-dipole antennas for high-gain integrated reflector illumination

A double-dipole antenna backed by a ground plane has been fabricated for submillimeter wavelengths. The double-dipole antenna is integrated on a thin dielectric membrane with a planar detector at its center. Measured feed patterns at 246 GHz agree well with theory and demonstrate a rotationally symmetric pattern with high coupling efficiency to Gaussian beams. The input impedance is around 50 ohms, and will match well to a Schottky diode or SIS detector. The double-dipole antenna served as the feed for a small machined parabolic reflector. The integrated reflector had a measured gain of 37 dB at 119 microns. This makes the double-dipole antenna ideally suited as a feed for high resolution tracking or for long focal length Cassegrain antenna systems.

Filipovic, Daniel F.↗

Experimental measurements of Space Station antenna patterns at 60 GHz for EM analysis verification

Complex body scattering is a major problem facing the electromagnetic researcher today. Computer codes are one important method for predicting such scattering. With funding from Langley, Ohio State University has developed such a code. A 30:1 scale model of the Space Station was constructed to be used as a scattering target in the verification of this code. The purpose here is to document the methods used to make these measurements and present the results which will be used by others for code verification.

Young, W. Robert↗

Optical Calibration Process Developed for Neural-Network-Based Optical Nondestructive Evaluation Method

A completely optical calibration process has been developed at Glenn for calibrating a neural-network-based nondestructive evaluation (NDE) method. The NDE method itself detects very small changes in the characteristic patterns or vibration mode shapes of vibrating structures as discussed in many references. The mode shapes or characteristic patterns are recorded using television or electronic holography and change when a structure experiences, for example, cracking, debonds, or variations in fastener properties. An artificial neural network can be trained to be very sensitive to changes in the mode shapes, but quantifying or calibrating that sensitivity in a consistent, meaningful, and deliverable manner has been challenging. The standard calibration approach has been difficult to implement, where the response to damage of the trained neural network is compared with the responses of vibration-measurement sensors. In particular, the vibration-measurement sensors are intrusive, insufficiently sensitive, and not numerous enough. In response to these difficulties, a completely optical alternative to the standard calibration approach was proposed and tested successfully. Specifically, the vibration mode to be monitored for structural damage was intentionally contaminated with known amounts of another mode, and the response of the trained neural network was measured as a function of the peak-to-peak amplitude of the contaminating mode. The neural network calibration technique essentially uses the vibration mode shapes of the undamaged structure as standards against which the changed mode shapes are compared. The published response of the network can be made nearly independent of the contaminating mode, if enough vibration modes are used to train the net. The sensitivity of the neural network can be adjusted for the environment in which the test is to be conducted. The response of a neural network trained with measured vibration patterns for use on a vibration isolation table in the presence of various sources of laboratory noise is shown. The output of the neural network is called the degradable classification index. The curve was generated by a simultaneous comparison of means, and it shows a peak-to-peak sensitivity of about 100 nm. The following graph uses model generated data from a compressor blade to show that much higher sensitivities are possible when the environment can be controlled better. The peak-to-peak sensitivity here is about 20 nm. The training procedure was modified for the second graph, and the data were subjected to an intensity-dependent transformation called folding. All the measurements for this approach to calibration were optical. The peak-to-peak amplitudes of the vibration modes were measured using heterodyne interferometry, and the modes themselves were recorded using television (electronic) holography.

Decker, Arthur J.↗

Axisymmetric Calculations of a Low-Boom Inlet in a Supersonic Wind Tunnel

This paper describes axisymmetric CFD predictions made of a supersonic low-boom inlet with a facility diffuser, cold pipe, and mass flow plug within wind tunnel walls, and compares the CFD calculations with the experimental data. The inlet was designed for use on a small supersonic aircraft that would cruise at Mach 1.6, with a Mach number over the wing of 1.7. The inlet was tested in the 8-ft by 6-ft Supersonic Wind Tunnel at NASA Glenn Research Center in the fall of 2010 to demonstrate the performance and stability of a practical flight design that included a novel bypass duct. The inlet design is discussed here briefly. Prior to the test, CFD calculations were made to predict the performance of the inlet and its associated wind tunnel hardware, and to estimate flow areas needed to throttle the inlet. The calculations were done with the Wind-US CFD code and are described in detail. After the test, comparisons were made between computed and measured shock patterns, total pressure recoveries, and centerline pressures. The results showed that the dual-stream inlet had excellent performance, with capture ratios near one, a peak core total pressure recovery of 96 percent, and a large stable operating range. Predicted core recovery agreed well with the experiment but predicted bypass recovery and maximum capture ratio were high. Calculations of offdesign performance of the inlet along a flight profile agreed well with measurements and previous calculations.

Chima, Rodrick V.↗

Analysis of a generalized dual reflector antenna system using physical optics

Reflector antennas are widely used in communication satellite systems because they provide high gain at low cost. Offset-fed single paraboloids and dual reflector offset Cassegrain and Gregorian antennas with multiple focal region feeds provide a simple, blockage-free means of forming multiple, shaped, and isolated beams with low sidelobes. Such antennas are applicable to communications satellite frequency reuse systems and earth stations requiring access to several satellites. While the single offset paraboloid has been the most extensively used configuration for the satellite multiple-beam antenna, the trend toward large apertures requiring minimum scanned beam degradation over the field of view 18 degrees for full earth coverage from geostationary orbit may lead to impractically long focal length and large feed arrays. Dual reflector antennas offer packaging advantages and more degrees of design freedom to improve beam scanning and cross-polarization properties. The Cassegrain and Gregorian antennas are the most commonly used dual reflector antennas. A computer program for calculating the secondary pattern and directivity of a generalized dual reflector antenna system was developed and implemented at LeRC. The theoretical foundation for this program is based on the use of physical optics methodology for describing the induced currents on the sub-reflector and main reflector. The resulting induced currents on the main reflector are integrated to obtain the antenna far-zone electric fields. The computer program is verified with other physical optics programs and with measured antenna patterns. The comparison shows good agreement in far-field sidelobe reproduction and directivity.

Acosta, Roberto J.↗

A parallel-series-fed microstrip array with high efficiency and low cross-polarization

The requirements of a microstrip array with a vertically polarized fan beam are addressed that correspond to its use in C-band interferometric SAR. A combination of parallel- and series-feed techniques are utilized in an array design with a three-stage parallel-fed configuration to enhance bandwidth performance. The linearly polarized traveling-wave microstrip array antenna is fed by microstrip transmission lines in two rows of 36 elements that resonate at 5.30 GHz. The transmission lines are impedance-matched at every junction for all the waves that travel toward the two ends of the array. The two measured principal-plane patterns are shown, and the measured narrow-beam pattern is found to agree with the calculated values. The VSWR bandwidths and narrow and broad beamwidths of the antenna are found to permit efficient performance. The efficiency is attributed to the parallel and series-feed configuration which allows proper impedance matching, and low cross-polarization is a result of the antiphase feed technique employed in the configuration.

Huang, John↗

Electronic Nose Development and Preliminary Human Breath Testing for Rapid, Non-Invasive COVID-19 Detection

We adapted an existing, spaceflight-proven, robust “electronic nose” (E-Nose) that uses an array of electrical resistivity-based nanosensors mimicking aspects of mammalian olfaction to conduct on-site, rapid screening for COVID-19 infection by measuring the pattern of sensor responses to volatile organic compounds (VOCs) in exhaled human breath. We built and tested multiple copies of a hand-held prototype E-Nose sensor system, composed of 64 chemically sensitive nanomaterial sensing elements tailored to COVID-19 VOC detection; data acquisition electronics; a smart tablet with software (App) for sensor control, data acquisition and display; and a sampling fixture to capture exhaled breath samples and deliver them to the sensor array inside the E-Nose. The sensing elements detect the combination of VOCs typical in breath at parts-per-billion (ppb) levels, with repeatability of 0.02% and reproducibility of 1.2%; the measurement electronics in the E-Nose provide measurement accuracy and signal-to-noise ratios comparable to benchtop instrumentation. Preliminary clinical testing at Stanford Medicine with 63 participants, their COVID-19-positive or COVID-19-negative status determined by concomitant RT-PCR, discriminated between these two categories of human breath with a 79% correct identification rate using “leave-one-out” training-and-analysis methods. Analyzing the E-Nose response in conjunction with body temperature and other non-invasive symptom screening using advanced machine learning methods, with a much larger database of responses from a wider swath of the population, is expected to provide more accurate on-the-spot answers. Additional clinical testing, design refinement, and a mass manufacturing approach are the main steps toward deploying this technology to rapidly screen for active infection in clinics and hospitals, public and commercial venues, or at home.

COVID-19↗

NISAR L-Band and S-Band Instrument Antennas: Compatibility Test and Results

Abstract—NASA ISRO SAR (NISAR) is one of the next major Earth science flight projects that NASA is currently developing in collaboration with ISRO, the Indian Space Research Organization. Featuring a 12m deployable off-set reflector, similar to SMAP but twice as large, and a dual band, dual polarization feed array, NISAR will measure with great accuracy even the smallest changes on our planet’s landmass, ice-sheet and forests over a 3 year period with a 12-day repeat cycle everywhere on the globe. Two radar systems will be sharing the same reflector, one operating in L-Band and one in S-Band. While the L-Band radar and feed antenna are being developed at Jet Propulsion Laboratory (JPL) for NASA, the S-Band feed antenna is under development at the Space Application Centre (SAC) in Ahmedabad, India, for ISRO. This paper describes the tests that were carried out both at JPL and SAC in order to verify that the level of compatibility between the two feed antennas were within the allocated requirements. Both S-parameters and radiation patterns were measured and compared with calculated predictions.

Harrell, Jefferson A.↗

A computerized program for statistical treatment of biological data

Biologists frequently conduct experiments which measure the patterns of inactivation of bacterial populations after exposure to a lethal environment. A computer program is discussed which calculates many of the quantities that have proven to be useful in the analysis of such experimental data.

Roark, A. L.↗

Optimization of electrostatic dual-grid beam-deflection system

Tests were performed to minimize accelerator grid erosion of a 5-cm diameter Kaufman ion thruster due to direct beam impingement. Several different screen hole diameters, pillow-shape-square screen holes, and dished screen grids were tried. The optimization was accomplished by copper plating the accelerator grid before testing each grid configuration on a thruster for a 2-hour run. The thruster beam sputtered copper and molybdenum from the accelerator grid where the beam impinged. The observed erosion patterns and measured accelerator currents were used to determine how to modify the accelerator system. The lowest erosion was obtained for a 50-percent open area pillow-shape-square-aperture screen grid, dished 0.043 centimeter convex toward the accelerator grid, which was positioned with the center of the screen grid 0.084 centimeter from the accelerator grid. During this investigation the accelerator current was reduced from 120 to 55 microamperes and was also more uniformly distributed over the area of the accelerator grid.

Hudson, W. R.↗

Analysis and design of aircraft antennas

Recording systems and other associated electronic equipment were engineered, calibrated, and used to measure antenna radiation patterns of aircraft structures. Antenna design, measured and computed results, and performance are discussed. Data show measured and computer data to be in agreement.

Balanis, C. A.↗

Soil moisture detection from radar imagery of the Phoenix, Arizona test site

The Environmental Research Institute of Michigan (ERIM) dual-polarization X and L band radar was flown to acquire radar imagery over the Phoenix (Arizona) test site. The site was covered by a north-south pass and an east-west pass. Radar response to soil moisture was investigated. Since the ERIM radar does not have accurately measured antenna patterns, analysis of the L band data was performed separately for each of several strips along the flight line, each corresponding to a narrow angle of incidence. For the NS pass, good correlation between the radar return and mositure content was observed for each of the two nearest (to nadir) angular ranges. At higher angular ranges, no correlation was observed. The above procedure was not applied to the EW pass due to flight path misalignments. The results obtained stress the importance of radar calibration, the digitization process, and the angle of incidence.

Cihlar, J.↗

Development of a high-resolution automatic digital (urine/electrolytes) flow volume and rate measurement system of miniature size

To aid in the quantitative analysis of man's physiological rhythms, a flowmeter to measure circadian patterns of electrolyte excretion during various environmental stresses was developed. One initial flowmeter was designed and fabricated, the sensor of which is the approximate size of a wristwatch. The detector section includes a special type of dielectric integrating type sensor which automatically controls, activates, and deactivates the flow sensor data output by determining the presence or absence of fluid flow in the system, including operation under zero-G conditions. The detector also provides qualitative data on the composition of the fluid. A compact electronic system was developed to indicate flow rate as well as total volume per release or the cumulative volume of several releases in digital/analog forms suitable for readout or telemetry. A suitable data readout instrument is also provided. Calibration and statistical analyses of the performance functions required of the flowmeter were also conducted.

Liu, F. F.↗

The role of eigenvalues in linear feature selection theory

A particular measure of pattern class distinction called the average interclass divergence, or more simply, divergence, is considered. Here divergence will be the pairwise average of the expected interclass divergence derived from Hajek's two-class divergence.

Brown, D. R.↗