Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

This document proposes to provide a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers, and books reviewed is given in Appendix 1. Available validation documents and guides are listed in the appendix; each has a brief description of application and use. In the referenced sources, there are varying approaches to validation and varying descriptions of validation at different stages in method development. This discussion focuses on validation and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all documents were published in English.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development, Testing and Validation of a Waste Assay System for the Measurement and Characterisation of Active Spent Fuel Element Debris From UK Magnox Reactors - 12533

This paper describes the development, testing and validation of a waste measurement instrument for characterising active remote handled radioactive waste arising from the operation of Magnox reactors in the United Kingdom. Following operation in UK Magnox gas cooled reactors and a subsequent period of cooling, parts of the magnesium-aluminium alloy cladding were removed from spent fuel and the uranium fuel rods with the remaining cladding were removed to Sellafield for treatment. The resultant Magnox based spent fuel element debris (FED), which constitutes active intermediate level waste (ILW) has been stored in concrete vaults at the reactor sites. As part of the decommissioning of the FED vaults the FED must be removed, measured and characterised and placed in intermediate storage containers. The present system was developed for use at the Trawsfynydd nuclear power station (NPS), which is in the decommissioning phase, but the approach is potentially applicable to FED characterisation at all of the Magnox reactors. The measurement system consists of a heavily shielded and collimated high purity Germanium (HPGe) detector with electromechanical cooling and a high count-rate preamplifier and digital multichannel pulse height analyser. The HPGe based detector system is controlled by a software code, which stores the measurement result and allows a comprehensive analysis of the measured FED data. Fuel element debris is removed from the vault and placed on a tray to a uniform depth of typically 10 cm for measurement. The tray is positioned approximately 1.2 meters above the detector which views the FED through a tungsten collimator with an inverted pyramid shape. At other Magnox sites the positions may be reversed with the shielded and collimated HPGe detector located above the tray on which the FED is measured. A comprehensive Monte Carlo modelling and analysis of the measurement process has been performed in order to optimise the measurement geometry and eliminate interferences from radioactive sources and FED in the immediate vicinity of the measurement position. The detector system has been calibrated and high activity radioactive sources of Cs-137, Co-60 and Na-22 have been used to validate the measurement process. The data acquisition and analysis software code has been tested and validated in keeping with the software quality assurance requirements of both ISO:9001-2008 - TICK-IT in the UK and NQA-1. The measurement and analysis system has been comprehensively tested with high activity sources, is flexible and may be applicable to a wide range of remote handled radioactive waste measurement applications. It is due to be installed at Trawsfynydd NPS later this year. This paper describes the Waste Tray Assay System (WTAS) that has been developed for the measurement of Magnox FED waste. The WTAS has been tested with a range of radioactive sources and its operation has been simulated with benchmarked MCNP Monte Carlo calculations. The measurement software has been validated as has the operation of the system for a range of strong radioactive sources. A system based on the design is due for installation and operation in 2012. The system has application to the measurement of Magnox Fuel Element Debris (FED) waste at other Magnox reactor sites. The major design objective of the WTAS that has been achieved is the ability of the assay system to determine the content of Cs-137, and in turn to enable the fissile burden to be assessed using a radionuclide fingerprint, in the presence of higher and highly variable quantities of Co-60, typically from nimonic springs. The approach can be used in other Magnox FED waste configurations where the detector is located above the FED waste sorting tray and where the collimation is fixed below the detector and at a distance above the tray. In this case, which has also been investigated, there are different shielding problems and mechanical support issues. The extensive use of MCNP Monte Carlo modelling to simulate the geometry of the sorting cell and the distribution of radioactive sources has helped to ensure that all of the detector shielding requirements are addressed and suitable Cs-137 and Co-60 discrimination can be achieved. The WTAS in its present form or in other configurations has relevance to the measurement of other active ILW and highly active RH waste. Examples include high activity RH LLW and RH TRU (Transuranic) waste as defined in the United States arising from both commercial nuclear and Department of Energy (DOE) operations. The analysis is able to analyse a range of radionuclides beyong those expected in the Magnox FED cases. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modular Autonomous Experimentation for Biological Applications

The Modular Autonomous Research System (MARS) was created to address a key challenge in scientific discovery: experiments are often slow, require significant manual labor, and generate data that is not easily integrated across different tools. This limits how quickly scientists can explore new materials, processes, and chemical reactions. Our motivation was to design a system that makes research faster, more reliable, and adaptable by combining automation with artificial intelligence. By doing so, we aimed to reduce human error, accelerate discovery, and allow researchers to quickly test many possibilities that would otherwise take months or years. Our approach was to build a flexible platform that connects laboratory robots, measurement instruments, and a central data system, all guided by artificial intelligence. MARS integrates liquid handling robots, robotic arms, and plate readers with an intelligent decision-making system that chooses the most informative experiments to run next. This creates a closed loop where experiments are performed automatically, the data is analyzed in real time, and new conditions are immediately tested. Through this work, we demonstrated that MARS can carry out multiple experiments with little or no human intervention, adapt to different scientific problems, and handle uncertain or noisy measurements in a robust way. The results show that modular and intelligent automation can significantly accelerate the pace of discovery, providing a model for future self-driving laboratories. This approach addresses the growing scientific need for adaptable, data-driven research platforms that can keep up with the complexity and scale of modern science.

59 BASIC BIOLOGICAL SCIENCES↗

Modular Autonomous Experimentation for Biological Applications (Full Report)

The Modular Autonomous Research System (MARS) was developed to address the pressing need for faster, more reliable, and more adaptable scientific discovery. Traditional experimentation is limited by manual labor, long cycle times, and fragmented data streams, which constrain the ability to explore complex chemical and materials design spaces. To overcome these limitations, we created an integrated, modular platform that combines laboratory robotics, diverse measurement instruments, and a central data infrastructure with artificial intelligence–driven decision-making. The system links liquid handling robots, robotic arms, and optical plate readers into a closed loop where experiments are executed automatically, data is analyzed in real time, and subsequent experimental conditions are adaptively chosen to maximize information gain. Over the course of the project, MARS was validated on two primary test cases—spectroscopic metal–ligand binding assays and peptide-directed mineralization—which highlighted the system’s ability to handle uncertainty and variability in experimental measurements. To further demonstrate modularity and extensibility, we also established additional testbeds in electrochemistry for catalyst discovery and electrolyte formulation for advanced batteries. The results show that MARS can reliably conduct autonomous campaigns with minimal human intervention, adapt to distinct scientific domains, and provide a scalable model for future self-driving laboratories. This work establishes new capabilities for modular, uncertainty-aware automation and directly supports the need for advanced, data-driven research platforms capable of accelerating discovery across a wide range of scientific and national security missions.

59 BASIC BIOLOGICAL SCIENCES↗

A high-resolving-power x-ray spectrometer for the OMEGA EP Laser (invited)

A high-resolving-power x-ray spectrometer has been developed for the OMEGA EP Laser System based on a spherically bent Si [220] crystal with a radius of curvature of 330 mm and a Spectral Instruments (SI) 800 Series charge-coupled device. The instrument measures time-integrated x-ray emission spectra in the 7.97- to 8.11-keV range, centered on the Cu K{sub α1} line. To demonstrate the performance of the spectrometer under high-power conditions, K{sub α1,2} emission spectra were measured from Cu foils irradiated by the OMEGA EP laser with 100-J, 1-ps pulses at focused intensities above 10{sup 18} W/cm{sup 2}. The ultimate goal is to couple the spectrometer to a picosecond x-ray streak camera and measure temperature-equilibration dynamics inside rapidly heated materials. The plan for these ultrafast streaked x-ray spectroscopy studies is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assimilation of Wave Imaging Radar Observations for Real-time Wave-by-Wave Forecasting

This project addressed Topic 3: “Wave Measurement Instrumentation for Feed Forward Controls” under the FOA number DE-FOA-0000971. The overall goal of the program was to develop a phase-resolving wave forecasting technique for application to the active control of Wave Energy Conversion (WEC) devices. We have developed an approach that couples a wave imaging marine radar with a phase-resolving linear wave model for real-time wave field reconstruction and forward propagation of the wave field in space and time. The scope of the project was to develop and assess the performance of this novel forecasting system. Specific project goals were as follows: Develop and verify a fast, GPU-based (Graphical Processing Unit) wave propagation model suitable for phase-resolved computation of nearshore wave transformation over variable bathymetry; Compare the accuracy and speed of performance of the wave model against a deep water model in their ability to predict wave field transformation in the intermediate water depths (50 to 70 m) typical of planned WEC sites; Develop and implement a variational assimilation algorithm that can ingest wave imaging radar observations and estimate the time-varying wave conditions offshore of the domain of interest such that the observed wave field is best reconstructed throughout the domain and then use this to produce model forecasts for a given WEC location; Collect wave-resolving marine radar data, along with relevant in situ wave data, at a suitable wave energy test site, apply the algorithm to the field data, assess performance, and identify any necessary improvements; and Develop a production cost estimate that addresses the affordability of the wave forecasting technology and include in the Final Report. The developed forecasting algorithm (“Wavecast”) was evaluated for both speed and accuracy against a substantial synthetic dataset. Early in the project, performance tests definitively demonstrated that the system was capable of forecasting in real-time, as the GPU-based wave model backbone was very computationally efficient. The data assimilation algorithm was developed on a polar grid domain in order to match the sampling characteristics of the observation system (wave imaging marine radar). For verification purposes, a substantial set of synthetic wave data (i.e. forward runs of the wave model) were generated to be used as ground truth for comparison to the reconstructions and forecasts produced by Wavecast. For these synthetic cases, Wavecast demonstrated very good accuracy, for example, typical forecast correlation coefficients were between 0.84-0.95 when compared to the input data. Dependencies on shadowing, observational noise, and forecast horizon were also identified. During the second year of the project, a short field deployment was conducted in order to assess forecast accuracy under field conditions. For this, a radar was installed on a fishing vessel and observations were collected at the South Energy Test Site (SETS) off the coast of Newport, OR. At the SETS site, simultaneous in situ wave observations were also available owing to an ongoing field project funded separately. Unfortunately, the position and heading information that was available for the fishing vessel were not of sufficient accuracy in order to validate the forecast in a phase-resolving sense. Instead, a spectral comparison was made between the Wavecast forecast and the data from the in situ wave buoy. Although the wave and wind conditions during the field test were complex, the comparison showed a promising reconstruction of the wave spectral shape, where both peaks in the bimodal spectrum were represented. However, the total reconstructed spectral energy (across all directions and frequencies) was limited to 44% of the observed spectrum. Overall, wave-by-wave forecasting using a data assimilation approach based on wave imaging radar observations and a physics-based wave model shows promise for short-term phase-resolved predictions. Two recommendations for future work are as follows: first, we would recommend additional focused field campaigns for algorithm validation. The field campaign should be long enough to capture a range of wave conditions relevant to the target application and WEC site. In addition, it will be crucial to make sure the vessel of choice has high accuracy position and heading instrumentation (this instrumentation is commercially available but not standard on commercial fishing vessels). The second recommendation is to expand the model physics in the wave model backbone to include some nonlinear effects. Specifically, the third-order correction to the wave speed due to amplitude dispersion would be the next step in order to more accurately represent the phase speeds of large amplitude waves.

16 TIDAL AND WAVE POWER↗

Postmidnight depletion of the high-energy tail of the quiet plasmasphere

The Van Allen Probes Helium Oxygen Proton Electron (HOPE) instrument measures the high energy tail of the thermal plasmasphere allowing study of topside ionosphere and inner magnetosphere coupling. We statistically analyze a 22 month period of HOPE data, looking at quiet times with a Kp index of less than 3. We investigate the high energy range of the plasmasphere, which consists of ions at energies between 1-10 eV and contains approximately 5% of total plasmaspheric density. Both the fluxes and partial plasma densities over this energy range show H + is depleted the most in the post-midnight sector (1-4 MLT), followed by O + and then He + . The relative depletion of each species across the post-midnight sector is not ordered by mass, which reveals ionospheric influence. We compare our results with keV energy electron data from HOPE and the Van Allen Probes Electric Fields and Waves (EFW) instrument spacecraft potential to rule out spacecraft charging. Our conclusion is that the post-midnight ion disappearance is due to diurnal ionospheric temperature variation and charge exchange processes

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the surface energy balance closure at different temporal scales

Measurements of the surface energy fluxes (turbulent and radiative) and other ancillary atmospheric/soil parameters made in the Columbia River Basin (Oregon) in an area of complex terrain during a 10-month long portion of the second Wind Forecast Improvement Project (WFIP 2) field campaign are used to study the surface energy budget (SEB) and surface fluxes over different temporal scales. This study analyzes and discusses SEB closure based on half-hourly, daily, monthly, seasonal, and sub-annual (~10-month) temporal averages. The data were collected over all four seasons for different states of the underlying ground surface (dry, wet, and frozen). Our half-hourly direct measurements of energy balance show that the sum of the turbulent sensible and latent heat fluxes systematically underestimate positive net radiation by around 20–30% during daytime and overestimate negative net radiation at night. This imbalance of the surface energy budget is comparable to other terrestrial sites. However, on average, the residual energy imbalance is significantly reduced at daily, weekly, and monthly averaging timescales, and moreover, the SEB can be closed for this site within reasonable limits on seasonal and sub-annual timescales (311-day averaging for the entire field campaign dataset). Increasing the averaging time to daily and longer time intervals substantially reduces the ground heat flux and storage terms, because energy locally entering the soil, air column, and vegetation in the morning is released in the afternoon and evening. Averaging on daily to sub-annual timescales also reduces random instrumental measurement errors and other uncertainties as well as smooths out a hysteresis effect (phase lag) in the SEB relationship between different components. This study shows that SEB closure is better for dry soils compared to wet soils and the statistical dependence of the turbulent fluxes and net radiation for freezing soil surfaces appears weak, if not non-existent, apparently due to lack of the latent heat of fusion term in the traditional SEB equation.

54 ENVIRONMENTAL SCIENCES↗

Development of a Low-Level Ar-37 Calibration Standard

Argon-37 is an important environmental signature of an underground nuclear explosion. Producing and quantifying low-level 37Ar standards is an important step in the development of sensitive field measurement instruments for use during an On-Site Inspection, a key provision of the Comprehensive Nuclear-Test-Ban Treaty. This paper describes progress at Pacific Northwest National Laboratory (PNNL) in the development of a process to generate and quantify low-level 37Ar standard material, which can then be used to calibrate sensitive field systems at activities consistent with soil background levels. The 37Ar used for our work was generated using a laboratory-scale, high-energy neutron source to irradiate powdered samples of calcium carbonate. Small aliquots of 37Ar were then extracted from the head space of the irradiated samples. The specific activity of the head space samples, mixed with P10 (90% stable argon:10% methane by mole fraction) count gas, is then derived using the accepted Length-Compensated Internal-Source Proportional Counting method. Due to the low activity of the samples, a set of three Ultra-Low Background Proportional-Counters designed and fabricated at PNNL from radio-pure electroformed copper was used to make the measurements in PNNL’s shallow underground counting laboratory. Very low background levels (<10 counts/day) have been observed in the spectral region near the 37Ar emission feature at 2.8 keV. Two separate samples from the same irradiation were measured. The first sample was counted for 12 days beginning 28 days after irradiation, the second sample was counted for 24 days beginning 70 days after irradiation (the half-life of 37Ar is 35.0 days). Both sets of measurements were analyzed and yielded very similar results for the starting activity (~0.1 Bq) and activity concentration (0.15 mBq/ccSTP argon) after P10 count gas was added. A detailed uncertainty model was developed based on the ISO Guide to the Expression of Uncertainty in Measurement. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.

Absolute radiation measurement↗

A new version of the LUPIN detector: Improvements and latest experimental verification

LUPIN-II is an upgraded version of LUPIN, a novel rem counter first developed in 2010 specifically conceived to work in pulsed neutron fields (PNFs). The new version introduces some modifications that improve the performance of the detector, in particular extending its upper detection limit in PNFs. This paper discusses the characteristics and the performance of the instrument. Measurements have been carried out in radiation fields characterized by very different conditions: the detector has first been exposed in PNFs with intensity up to 5 μSv per burst, where it could keep the H*(10) underestimation below 20% up to 500 nSv per burst. It has then been tested in operational conditions around particle accelerators, where it has shown performances similar to that of ionization chambers. Its proper functioning has also been verified in high energy mixed fields, where the experimental results matched the Monte Carlo predictions. Its neutron/photon discrimination capability has been tested in a steady-state photon field where, via an innovative technique based on a threshold set on the derivative of the current signal, it was capable of rejecting a photon H*(10) rate of about 25 mSv/h, and in a mixed neutron/photon field, where a time-based discrimination method was employed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracking Elevated Pollution Layers with a Newly Developed Hyperspectral Sun/Sky Spectrometer (4STAR): Results from the TCAP 2012 and 2013 Campaigns

Total columnar amounts of water vapor, nitrogen dioxide (NO2) and ozone (O3) are derived from a newly developed, hyperspectral airborne sun-sky spectrometer (4STAR) for the first time during the two intensive phases of the Two Column Aerosol Project (TCAP) in summer 2012 and winter 2013 aboard the DOE G-1 aircraft. We compare results with coincident measurements. We find 0.045 g/cm2 (4.2%) negative bias and 0.28 g/cm2 (26.3%) root-mean-square (RMS) difference in water vapor layer comparison with in-situ hygrometer, and an overall RMS difference of 1.28 g/m3 (38%) water vapor amount in profile by profile comparisons, with differences distributed evenly around zero in most cases. The RMS differences for O3 values average to 3%, with a 1% negative bias for 4STAR compared with the spaceborne Ozone Measuring Instrument (OMI) along the aircraft flight-track for 14 flights during both TCAP phases. Ground-based comparisons with the Pandora spectrometer system at the Goddard Space Flight Center (GSFC), Greenbelt, Maryland showed excellent agreement between the instruments for both O3 and NO2, further emphasizing 4STAR’s new capabilities. During the summer phase, we have succeeded in identifying variations in elevated pollution layers corresponding to urban pollution outflow and transported biomass burning. This was done using clustering analysis of the retrieved products (e.g. Ångstrom exponent, NO2 and columnar water vapor), and was confirmed by aerosol type identification by HSRL2 aboard the NASA B-200 aircraft. These newly demonstrated 4STAR capabilities are expected to be instrumental in improving our understanding of atmospheric composition variability and aerosol-trace-gas interactions; they open new horizons and opportunities in airborne sunphotometry.

4STAR↗

Whistler anisotropy instabilities as the source of banded chorus: Van Allen Probes observations and particle-in-cell simulations

Magnetospheric banded chorus is enhanced whistler waves with frequencies ω r < Ω e , where Ω e is the electron cyclotron frequency, and a characteristic spectral gap at ω r ≃ Ω e /2. This paper uses spacecraft observations and two-dimensional particle-in-cell simulations in a magnetized, homogeneous, collisionless plasma to test the hypothesis that banded chorus is due to local linear growth of two branches of the whistler anisotropy instability excited by two distinct, anisotropic electron components of significantly different temperatures. The electron densities and temperatures are derived from Helium, Oxygen, Proton, and Electron instrument measurements on the Van Allen Probes A satellite during a banded chorus event on 1 November 2012. The observations are consistent with a three-component electron model consisting of a cold (a few tens of eV) population, a warm (a few hundred eV) anisotropic population, and a hot (a few keV) anisotropic population. The simulations use plasma and field parameters as measured from the satellite during this event except for two numbers: the anisotropies of the warm and the hot electron components are enhanced over the measured values in order to obtain relatively rapid instability growth. The simulations show that the warm component drives the quasi-electrostatic upper band chorus and that the hot component drives the electromagnetic lower band chorus; the gap at ~Ω e /2 is a natural consequence of the growth of two whistler modes with different properties.

58 GEOSCIENCES↗

Energetic Particle Data From the Global Positioning System Constellation

Abstract Since 2000, Los Alamos National Laboratory (LANL) Combined X‐ray and Dosimeter (CXD) and Burst Detector Dosimeter for Block II‐R (BDD‐IIR) instruments have been fielded on Global Positioning System (GPS) satellites. Today, 21 of the 31 operational GPS satellites are equipped with a CXD detector and a further 2 carry a BDD‐IIR. Each of these instruments measures a wide range of energetic electrons and protons. These data have now been publicly released under the terms of the Executive Order for Coordinating Efforts to Prepare the Nation for Space Weather Events. The specific goal of releasing space weather data from the GPS satellites is to enable broad scientific community engagement in enhancing space weather model validation and improvements in space weather forecasting and situational awareness. The time period covered by this data release is approximately 16 years, which corresponds to more than 167 satellite years of data. The large number of GPS satellites, distributed over six orbital planes, will provide important context for ongoing and historical science missions, as well as enabling new types of research not previously possible.

54 ENVIRONMENTAL SCIENCES↗

In-situ monitoring of flow-permeable surface area of high explosive powder using small sample masses

To ensure good performance of high explosive devices over long periods of time, initiating powders need to maintain their specific surface area within allowed margins during the entire duration of deployment. A common diagnostic used in this context is the Fisher sub-sieve surface area (FSSA). Furthermore, commercial permeametry instruments measuring the FSSA requires the utilization of a sample mass equal to the crystal density of the sample material, an amount that is often one or two orders of magnitude larger than the typical masses found in standard detonator applications. Here we develop a customization of the standard device that can utilize just tens of milligram samples, and with simple calibration yield FSSA values at ac curacy levels comparable to the standard apparatus. This necessitated a newly designed sample holder, made from a material of low coefficient of thermal expansion, which is conveniently transferred between an aging chamber and a re-designed permeametry tube. This improves the fidelity of accelerated aging studies by allowing measurement on the same physical sample at various time - instants during the aging process, and by obviating the need for a potentially FSSA-altering powder re-compaction step. We used the customized apparatus to monitor the FSSA evolution of a number of undoped and homolog-doped PETN powder samples that were subjected to artificial aging for several months at elevated temperatures. These results, in conjunction with an Arrhenius-based aging model were used to assess powder-coarsening - rates under long-term storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Braking Conditions on Tribological Performance of Copper-Based Powder Metallurgical Braking Material

High-speed transportation tools demand durable and effective friction materials for practical applications. In this work, we developed a copper-based powder metallurgical friction material via spark plasma sintering, and studied its tribological performances subjected to different braking conditions. Using inertial braking test bench and temperature measuring instrument, average friction coefficient, instantaneous friction coefficient and temperature near friction surface of the material in braking process were tested at two initial speeds (28, 69 m/s) and three contact pressures (0.4, 0.6 and 0.8 MPa). The wear rate of materials was calculated accordingly. Results show that under the same exerted pressure, the average friction coefficient and wear rate at the high speed are smaller than those at the low speed. At the high test speed, the high friction temperature leads to an obvious decrease in instantaneous friction coefficient when the braking process reaches a certain stage. Based on the friction surface morphology analysis, the adhesive wear on the surface has been reduced because of the formation of oxide films at the high speed and surface oxidation wear gradually increases as the pressure increases.

36 MATERIALS SCIENCE↗

Payload concepts for investigations of electrostatic dust motion on the lunar surface

Significant experimental and computational investigations have explored the feasibility of electrostatically-motivated dust motion on the lunar surface. The motion of lunar dust influences our understanding of the evolution of the surface and may also present a hazard to future exploration vehicles and astronauts. The possibility of a sustained exploration presence on the lunar surface opens the door to long-term experiments on the lunar surface, akin to the science facilities on the International Space Station. We have identified four measurements/observations that would significantly advance our understanding of dust-plasma interactions on the lunar surface. In this context, we provide conceptual designs for payloads to obtain these observations: a Langmuir probe, dust deposit witness plate, regolith charge measurement instrument, and cameras to look for evidence of horizon glow. These payloads could deploy independently and sequentially, or together as a suite. The proposed payloads would provide key observations that would inform future modeling efforts and direct future in situ experiments to understand the dust-plasma environment, both for planetary science and spacecraft design applications.

42 ENGINEERING↗

MITgcm-AD v2: Open source tangent linear and adjoint modeling framework for the oceans and atmosphere enabled by the Automatic Differentiation tool Tapenade

The Massachusetts Institute of Technology General Circulation Model (MITgcm) is widely used by the climate science community to simulate planetary atmosphere and ocean circulations. A defining feature of the MITgcm is that it has been developed to be compatible with an algorithmic differentiation (AD) tool, TAF, enabling the generation of tangent-linear and adjoint models. These provide gradient information which enables dynamics-based sensitivity and attribution studies, state and parameter estimation, and rigorous uncertainty quantification. Importantly, gradient information is essential for computing comprehensive sensitivities and performing efficient large-scale data assimilation, ensuring that observations collected from satellites and in-situ measuring instruments can be effectively used to optimize a large uncertain control space. As a result, the MITgcm forms the dynamical core of a key data assimilation product employed by the physical oceanography research community: Estimating the Circulation and Climate of the Ocean (ECCO) state estimate. Although MITgcm and ECCO are used extensively within the research community, the AD tool TAF is proprietary and hence inaccessible to a large proportion of these users. The new version 2 (MITgcm-AD v2) framework introduced here is based on the source-to-source AD tool Tapenade, which has recently been open-sourced. Another feature of Tapenade is that it stores required variables by default (instead of recomputing them) which simplifies the implementation of efficient, AD-compatible code. The framework has been integrated with the MITgcm model’s main branch and is now freely available.

Adjoints↗

Progress in end-to-end optimization of fundamental physics experimental apparata with differentiable programming

In this article we examine recent developments in the research area concerning the creation of end-to-end models for the complete optimization of measuring instruments. The models we consider rely on differentiable programming methods and on the specification of a software pipeline including all factors impacting performance — from the data-generating processes to their reconstruction and the inference on the parameters of interest — along with the careful specification of a utility function well aligned with the end goals of the experiment. Building on previous studies originated within the MODE Collaboration, we focus specifically on applications involving instruments for particle physics experimentation, as well as industrial and medical applications that share the detection of radiation as their data-generating mechanism. This report illustrates the most recent advancements in the area, and outlines, for each of the discussed applications as well as for automatic differentiation itself, ongoing and future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗