Search NASA⌕ Search

SEARCH · Search NASA

Results for “MicroED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A tutorial on the micro-trench technique for incident ion angle, material erosion, and impurity deposition measurements at plasma-facing surfaces

The micro-trench method is a new technique to measure polar and azimuthal incident ion angles, material erosion, and impurity deposition at plasma-facing surfaces, and has been applied in the DIII-D divertor. This article gives a tutorial of the micro-trench technique consisting of six steps: (1) micro-trench fabrication, (2) pre-exposure measurement of the fabricated micro-trench geometry, (3) tracer material deposition, (4) plasma exposure, (5) post-exposure observation of the tracer material, and (6) post-exposure measurement of the micro-trench geometry. Two criteria need to be satisfied to apply the micro-trench method successfully: (i) uniform impurity deposition on the micro-trench floor, and (ii) erosion dominated by the physical sputtering induced by the impinging ions. Furthermore, when those two criteria are satisfied, post-exposure analysis of the impurity deposition patterns on the micro-trench floor may be used to determine the polar and azimuthal incident ion directions (mean values of the ion angle directions), erosion rate, and impurity deposition rate during plasma exposure without computational interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication Of Micro-Nozzles Via {mu}-EDM Process

Since traditional handling mechanisms have an unpredictable behavior at micro scale, micro-assembly is a bottleneck in the development of hybrid micro-systems, and the development of new approaches is strongly demanded. In this paper, a recent study of the fabrication of a ceramics vacuum micro-gripper to handle parts in the range of hundreds of microns (300-1000) is presented. Among the possible micro manufacturing processes, micro-EDM has been selected as proving to be a very competitive fabrication technology for the manufacturing of ultra miniature components and micro sized features. The influence of the process parameters on the machining performance of interest is firstly investigated; then, the experimental results on machining the micro gripper are presented, finally concluding remarks are given.

36 MATERIALS SCIENCE↗

Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro-CT

Purpose: At present, no established methods exist for dosimetry in micro computed tomography (micro-CT). The purpose of this study was therefore to investigate practical concepts for both dosimetric scanner quality assurance and tissue dose assessment for micro-CT. Methods: The computed tomography dose index (CTDI) was adapted to micro-CT and measurements of the CTDI both free in air and in the center of cylindrical polymethyl methacrylate (PMMA) phantoms of 20 and 32 mm diameter were performed in a 6 month interval with a 100 mm pencil ionization chamber calibrated for low tube voltages. For tissue dose assessment, z-profile measurements using thermoluminescence dosimeters (TLDs) were performed and both profile and CTDI measurements were compared to Monte Carlo (MC) dose calculations to validate an existing MC tool for use in micro-CT. The consistency of MC calculations and TLD measurements was further investigated in two mice cadavers. Results: CTDI was found to be a reproducible quantity for constancy tests on the micro-CT system under study, showing a linear dependence on tube voltage and being by definition proportional to mAs setting and z-collimation. The CTDI measured free in air showed larger systematic deviations after the 6 month interval compared to the CTDI measured in PMMA phantoms. MC calculations were found to match CTDI measurements within 3% when using x-ray spectra measured at our micro-CT installation and better than 10% when using x-ray spectra calculated from semi-empirical models. Visual inspection revealed good agreement for all z-profiles. The consistency of MC calculations and TLD measurements in mice was found to be better than 10% with a mean deviation of 4.5%. Conclusions: Our results show the CTDI implemented for micro-CT to be a promising candidate for dosimetric quality assurance measurements as it linearly reflects changes in tube voltage, mAs setting, and collimation used during the scan, encouraging further studies on a variety of systems. For tissue dose assessment, MC calculations offer an accurate and fast alternative to TLD measurements allowing for dose calculations specific to any geometry and scan protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-84: Accuracy Comparison of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using In-Air Micro-CT Image Volume

Purpose: Tumor volume is considered as a better predictor for therapy response monitoring and tumor staging over Response Evaluation Criteria In Solid Tumors (RECIST) or World Health Organization (WHO) criteria. In this study, the accuracy of subcutaneous rodent tumor volumes using preclinical magnetic resonance imaging (MRI), micro-computed tomography (micro-CT) and ultrasound (US) equipment and with an external caliper was compared using in-air micro-CT image volume of excised tumors determined as reference tumor volume in our prior study. Methods: MR, US and micro-CT images of subcutaneous SCC4 head and neck tumor xenografts were acquired 4, 6, 9, 11 and 13 days after tumor cell inoculation. Before MR and US scans, caliper measurements were made. After tumors were excised, in-air micro-CT imaging and ex vivo caliper measurements were performed. Tumor volumes were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three image modalities and caliper, and compared with reference tumor volume by linear regression analysis as well as Bland-Altman plots. A one-way Analysis of Variance (ANOVA) test was also performed to compare volumes among caliper measurements. Results: The correlation coefficients (R2) of the regression lines for tumor volumes measured by the three imaging modalities and caliper were 0.9939, 0.9669, 0.9806, 0.9274, 0.9619 and 0.9819 for MRI, US and micro-CT, caliperbeforeMRI, caliperbeforeUS and ex vivo caliper respectively. In Bland-Altman plots, the average of tumor volume difference from reference tumor volume (bias) was significant for caliper and micro- CT, but not for MRI and US. Comparison of caliper measurements showed a significant difference (p < 0.05). Conclusion: Using the in-air micro-CT image volume, tumor volume measured by MRI was the most accurate among the three imaging modalities. In vivo caliper volume measurements showed unreliability while ex vivo caliper measurements reduced errors.

60 APPLIED LIFE SCIENCES↗

Advanced Moderation Module for High-Temperature Micro-Reactor Applications

Development and deployment of micro-reactors that provide competitive efficiency, prevailing compactness, and inherent safety is an immediate focus of the U.S. nuclear industry. For thermal neutron micro-reactors operating at elevated temperature for optimized efficiency, such as micro molten-salt reactors (MSRs), heat-pipe reactors, and very-high temperature reactors (VHTRs), high-performance moderator based on metal hydride can enhance the neutron economy and therefore achieve reduced weight and enhanced portability. As unclad metal hydride inevitably decomposes at elevated temperature, an enclosure is required for hydride moderator to deliver desired performance at elevated temperatures. Conventional moderator enclosure solutions based on high-temperature alloys introduce extraneous neutron penalty into the micro-reactor, affecting the neutronic benefits provided by the hydride moderator. Additionally, the compatibility between the high-temperature alloy enclosure and the micro-reactor matrix is also a potential issue. In this report, we disclose an Advanced Moderator Module (AMM) concept enabled by an innovative enclosure solution combining the advantages of refractory metals, ceramic matrix composites (CMCs), and advanced coating technology to serve as hydrogen permeation barrier up to very-high temperatures. A schematic description of the AMM structure is illustrated in Figure A1. The AMM contains a moderating material core made of metal hydride with high thermal stability, such as YH 2-x . The hydride core is enclosed by an H 2 barrier layer coated on a ductile refractory metal liner to minimize hydrogen loss during high-temperature operation. A ceramic matrix composite (CMC) cladding is adopted to provide further structural strength, especially during power transients. Between the CMC cladding and metal liner, an extra diffusion barrier coating is inserted to suppress the chemical interaction at elevated temperatures. Hence, based on a series of innovative material solutions, the AMM is capable of containing the metal hydride core at elevated temperature (>900oC) inside coated and lined CMC envelop with negligible hydrogen loss throughout the microreactor lifetime. The benefit of the AMM technology was assessed based on a comprehensive multi-stage reactor-physics analysis. Advanced moderation based on hydride metals (such as YH2-x) enables reaching optimum moderation with higher fuel content than traditional VHTR technology, which is required to design compact micro-reactor cores targeting long-life operation. The AMM enclosure technology provides lower thermal neutron absorption rates than traditional solutions (based on stainless steel or Mo-based alloy such as TZM), which reduces the fissile enrichment requirements by 6-8% on a TRISO-fueled design based on the EMPIRE core. Finally, combining the hydride moderator with neutron transparent enclosure solutions provides significant potential to boost neutronics performance of micro-reactors in terms of increased core lifetime or reduced size and weight by 30-50% on a micro-reactor based on the Holos Quad technology. The progress and plans for on-going development and demonstration efforts are also discussed in this report. The current demonstration of AMM is focused on the hydrogen diffusion barrier demonstration under thermal cycling, while radiation tolerance demonstration is planned. The next step of the demonstration plan will be the assembly of miniature AMM for high-temperature testing, which can be used as a prototype for future pilot scale demonstration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SUMC reconfigurable micro-assembler

The development of a reconfigurable micro-assembler to provide the micro-programmer the capability to specify micro-instructions in concise, meaningful terms is discussed. The implementation plan for the development of the micro-assembler was predicted on the existing capabilities of the SUMC Reconfigurable Assembler. Utilizing the reconfigurable assembler as a base, new directives and existing directive modifications were implemented to provide the micro-assembly as a new capability of the reconfigurable assembler. The micro-assembler language allows the specification of all micro-instruction control field settings in one concise assembler source statement. The language appears very similar to a conventional machine instruction assembler language. The machine instruction assembler language has the characteristic of one operation specification per statement whereas, the micro-instruction assembler language allows multiple operations to be designated per statement.

Edwards, A. J.↗

Liquid metal micro heat pipes for space radiator applications

Micromachining is a chemical means of etching three-dimensional structures, typically in single-crystalline silicon. These techniques are leading toward what is coming to be referred to as MEMS (micro electro mechanical systems), where in addition to the ordinary two dimensional (planar) microelectronics, it is possible to build three-dimensional micromotors, electrically-actuated microvalves, hydraulic systems, and much more on the same microchip. These techniques become possible because of differential etching rates of various crystallographic planes and materials used for semiconductor microfabrication. The University of Cincinnati group in collaboration with NASA Lewis formed micro heat pipes in silicon by the above techniques. Work is ongoing at a modest level, but several essential bonding and packaging techniques have been recently developed. Currently, we have constructed and filled water/silicon micro heat pipes. Preliminary thermal tests of arrays of 125 micro heat pipes etched in a 1 inch x 1 inch x 250 micron silicon wafer have been completed. These pipes are instrumented with extremely small P-N junctions to measure their effective conductivity and their maximum operating power. A relatively simple one-dimensional model has been developed in order to predict micro heat pipes' operating characteristics. This information can be used to optimize micro heat pipe design with respect to length, hydraulic diameter, and number of pipes. Work is progressing on the fabrication of liquid-metal micro heat pipes. In order to be compatible with liquid metal (sodium or potassium), the inside of the micro heat pipes will be coated with a refractory metal (such as tungsten, molybdenum, or titanium).

Gerner, F. M.↗

X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass. These scans show the clast to be approx.4.5 g, however (assuming a density of approx.3.5 g/cc). This is large enough for detailed studies including multiple geo-chronometers. This basalt clast is of particular interest as it is the largest Apollo 16 basalt, and it is the only mid-TiO2 basalt in the Apollo sample suite. By identifying the location of interesting clasts or grains within a sample, we will be able to make more informed decisions about where to cut a sample in order to best expose clasts of interest for future study. Moreover, knowing the location of internal defects (e.g., fractures) will allow more precise chipping and extraction of clasts or grains. By combining micro-CT scans with compositional techniques like micro x-ray fluorescence (particularly on sawn slabs), we will be able to provide even more comprehensive information to scientists trying to best select samples that fit their scientific needs.

Ziegler, R. A.↗

Compressing micro-operations in scheduler entries in a processor

An electronic device includes a processor having a micro-operation queue, multiple scheduler entries, and scheduler compression logic. When a pair of micro-operations in the micro-operation queue is compressible in accordance with one or more compressibility rules, the scheduler compression logic acquires the pair of micro-operations from the micro-operation queue and stores information from both micro-operations of the pair of micro-operations into different portions in a single scheduler entry. In this way, the scheduler compression logic compresses the pair of micro-operations into the single scheduler entry.

Boyer, Michael W.↗

X-Ray Fluorescence Quantitative and Qualitative Analysis Using Micro Glass Beads

The fused glass bead method is the accepted 'best practice' method of preparation of samples for X-ray fluorescence (XRF) analysis. It minimizes the effects of sample heterogeneity and simplifies calibration by dissolving the sample into a uniform glass matrix. Glass fusion XRF samples are typically prepared by grinding sample powder with Lithium Tetraborate / Lithium Bromide and fusing the mixture at 1000 deg. C. In most cases sample-to-flux ratios of between 1:1 to 1:10 are used (1:1 for determination of trace elements and 1:10 for major elements). Typical sample mass consumed is in the range of 1000 to 2500 mg. It would be advantageous to reduce this sample mass in cases where the sample material is rare, valuable or highly radioactive. This study examines the effects of using lower sample-to-flux ratios and smaller fusion bead size on the detection and quantification of major and trace elements by XRF analysis. We have employed a micro fused glass bead process, using sample-to-flux ratios of 1:10, 1:15 and 1:25, to determine the effects on measurement precision, accuracy and detection limit. Objectives: - Created micro fused glass beads of a series of standards and andesite sample with sample-to-flux ratios of 1:10, 1:15 and 1:25. - Perform an qualitative analysis of the different sample-to-flux ratio micro beads and compare the results with the 1:5.3 beads routinely used at SRNL. - Quantitate the major components in the different sample-to-flux ratio micro beads using a wavelength dispersive x-ray fluorescence instrument. Advantages: - Reduce sample amount needed. - Speed up waste tank characterization. - Reduce personnel exposure. - Potential sealed source. Fused micro glass beads with sample-to-flux ratios of 1:10, 1:15 and 1:25 were created using sample amounts of 123 mg, 82 mg and 52 mg respectively. It was possible to detect most of the major oxides and some trace elements in the fused micro glass beads with different sample-to-flux ratios. The quantitative analysis showed good linear correlation between the intensity of the analysis and the concentration of the elements. Good precision and accuracy results were obtained for the majority of the major oxides in the three fused micro glass beads with different sample-to-flux ratios. Path Forward: Enhance the precision and accuracy of the method by optimizing different sample preparation steps, such as weighing and sample transfer. Continue to increase the sample-to-flux ratio to determine the minimum amount of sample needed to perform a multielement analysis. Consider the use of synthetic standards to lower the detection limit of the analysis. Used the micro bead sample preparation method to analyze radioactive samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study on premixed combustion in cylindrical micro combustors: Transient flame behavior and wall heat flux

The micro combustor is a key component of the micro thermophotovoltaic (TPV) system. Improving the wall temperature of the micro combustor is an effective way to elevate the system efficiency. An experimental study on the wall temperature and radiation heat flux of a series of cylindrical micro combustors (with a backward-facing step) was carried out. For the micro combustors with d = 2 mm, the regime of successful ignition (under the cold wall condition) was identified for different combustor lengths. Acoustic emission was detected for some cases and the emitted sound was recorded and analyzed. Under the steady-state condition, the effects of the combustor diameter (d), combustor length (L), flow velocity (u{sub 0}) and fuel-air equivalence ratio ({phi}) on the wall temperature distribution were investigated by measuring the detailed wall temperature profiles. In the case that the micro combustor is working as an emitter, the optimum efficiency was found at {phi} {approx} 0.8, independent of the combustor dimensions (d and L) and the flow velocity. Under the experimental conditions employed in the present study, the positions of the peak wall temperature were found to be about 8-11 mm and 4-6 mm from the step for the d = 3 mm and d = 2 mm micro combustors, respectively, which are 8-11 and 8-12 times of their respective step heights. This result suggests that the backward-facing step employed in the combustor design is effective in stabilizing the flame position. (author)

30 DIRECT ENERGY CONVERSION↗

Preparation of novel layer-stack hexagonal CdO micro-rods by a pre-oxidation and subsequent evaporation process

Graphical abstract: Layer-stack hexagonal cadmium oxide (CdO) micro-rods were prepared. - Highlights: • Novel hexagonal layer-stack structure CdO micro-rods were synthesized by a thermal evaporation method. • The pre-oxidation, vapor pressure and substrate nature play a key role on the formation of CdO rods. • The formation mechanism of CdO micro-rods was explained. - Abstract: Novel layer-stack hexagonal cadmium oxide (CdO) micro-rods were prepared by pre-oxidizing Cd granules and subsequent thermal oxidation under normal atmospheric pressure. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were performed to characterize the phase structure and microstructure. The pre-oxidation process, vapor pressure and substrate nature were the key factors for the formation of CdO micro-rods. The diameter of micro-rod and surface rough increased with increasing of thermal evaporation temperature, the length of micro-rod increased with the increasing of evaporation time. The formation of hexagonal layer-stack structure was explained by a vapor–solid mechanism.

36 MATERIALS SCIENCE↗

Optimization of micro-aeration intensity in acidogenic reactor of a two-phase anaerobic digester treating food waste

Highlights: • Effect of micro-aeration on acidogenesis and hydrolysis of food waste was investigated. • Micro-aeration at 258 L-air/kg TS/d increased the VFAs production 3-fold. • High aeration leads to loss of substrate through microbial biomass and respiration. • Optimum aeration increased methane recovery while high aeration intensity reduced methane yield. - Abstract: Micro-aeration is known to promote the activities of hydrolytic exo-enzymes and used as a strategy to improve the hydrolysis of particulate substrate. The effect of different micro-aeration rates, 0, 129, 258, and 387 L-air/kg TS/d (denoted as LBR-AN, LBR-6h, LBR-3h and LBR-2h, respectively) on the solubilization of food waste was evaluated at 35 °C in four leach bed reactors (LBR) coupled with methanogenic upflow anaerobic sludge blanket (UASB) reactor. Results indicate that the intensity of micro-aeration influenced the hydrolysis and methane yield. Adequate micro-aeration intensity in LBR-3h and LBR-2h significantly enhanced the carbohydrate and protein hydrolysis by 21–27% and 38–64% respectively. Due to the accelerated acidogenesis, more than 3-fold of acetic acid and butyric acid were produced in LBR-3h as compared to the anaerobic treatment LBR-AN resulting in the maximum methane yield of 0.27 L CH{sub 4}/g VS{sub added} in the UASB. The performance of LBR-6h with inadequate aeration was similar to that of LBR-AN with a comparable hydrolysis degree. Nevertheless, higher aeration intensity in LBR-2h was also unfavorable for methane yield due to significant biomass generation and CO{sub 2} respiration of up to 18.5% and 32.8% of the total soluble hydrolysate, respectively. To conclude, appropriate micro-aeration rate can promote the hydrolysis of solid organic waste and methane yield without undesirable carbon loss and an aeration intensity of 258 L-air/kg TS/d is recommended for acidogenic LBR treating food waste.

09 BIOMASS FUELS↗

Applications of synchrotron-based micro-imaging techniques for the analysis of Cultural Heritage materials

The analysis of cultural Heritage objects is often technically challenging. When analyzing micro-fragments, the amount of matter is usually very tiny, hence requiring sensitive techniques. These samples, in particular painting fragments, may present multi-layered structures, with layer thickness of {approx}10 {mu}m. It leads to favor micro-imaging techniques, with a good lateral resolution (about one micrometer), that manage the discriminative study of each layer. Besides, samples are usually very complex in term of chemistry, as they are made of mineral and organic matters, amorphous and crystallized phases, major and minor elements. Accordingly, a multi-modal approach is generally essential to solve the chemical complexity of such hybrid materials. Different examples will be given, to illustrate the various possibilities of synchrotron-based micro-imaging techniques, such as micro X-ray diffraction, micro X-ray fluorescence, micro X-ray absorption spectroscopy and micro FTIR spectroscopy. Focus will be made on paintings, but the whole range of museum objects (going from soft matter like paper or wood to hard matter like metal and glass) will be also considered.

36 MATERIALS SCIENCE↗

Suppression of secondary electron yield by micro-porous array structure

We study secondary electron yield (SEY) suppression for metal materials using a roughened surface with a micro-porous array. First, we perform a Monte Carlo simulation of the electron trajectory in a single cylindrical well using a phenomenological model of secondary electron emission and the SEY suppression efficiency of a micro-porous array. The simulation results show that the SEY of a roughened surface is affected significantly by the aspect ratio of the micro-pores and the surface porosity of the metal plate. Then, to verify the simulation results, we produce a micro-porous array on metal plates using photolithography and measure their SEYs. We show that the micro-porous array structure can efficiently suppress the SEY of metal materials, and the measurements agree quantitatively with the corresponding simulation results. Finally, we derive an analytical formula to evaluate easily the SEY suppression efficiency of the Ag micro-porous array. In total, the micro-porous array proposed in this paper offers an alternative to SEY suppression in related areas such as multipactor effects in satellite payloads or electron cloud effects in accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Growth and characterizations of GaN micro-rods on graphene films for flexible light emitting diodes

We report the growth of GaN micro-rods and coaxial quantum-well heterostructures on graphene films, together with structural and optical characterization, for applications in flexible optical devices. Graphene films were grown on Cu foil by means of chemical vapor deposition, and used as the substrates for the growth of the GaN micro-rods, which were subsequently transferred onto SiO{sub 2}/Si substrates. Highly Si-doped, n-type GaN micro-rods were grown on the graphene films using metal–organic chemical vapor deposition. The growth and vertical alignment of the GaN micro-rods, which is a critical factor for the fabrication of high-performance light-emitting diodes (LEDs), were characterized using electron microscopy and X-ray diffraction. The GaN micro-rods exhibited promising photoluminescence characteristics for optoelectronic device applications, including room-temperature stimulated emission. To fabricate flexible LEDs, In{sub x}Ga{sub 1–x}N/GaN multiple quantum wells and a p-type GaN layer were deposited coaxially on the GaN micro-rods, and transferred onto Ag-coated polymer substrates using lift-off. Ti/Au and Ni/Au metal layers were formed to provide electrical contacts to the n-type and p-type GaN regions, respectively. The micro-rod LEDs exhibited intense emission of visible light, even after transfer onto the flexible polymer substrate, and reliable operation was achieved following numerous cycles of mechanical deformation.

36 MATERIALS SCIENCE↗

Site-specific Pt Deposition and Etching on Electrically and Thermally Isolated SiO2 Micro-disk Surfaces

Electrically and thermally isolated surfaces are often crucial for improving the detection sensitivity of microelectronic sensors. The site specific in-situ growth of Pt nano-rods on thermally and electrically isolated micro-fabricated SiO2 disks using wet chemical etching and focused ion/electron dual-beam (FIB-SEM) is demonstrated in this work. Fabrication of an array of micro-cavities on top of micro-disk is also demonstrated. FIB source is also utilized to fabricate through-holes in the micro-disks. The nature of Ga Gaussian distribution in the Ga-implanted region using a FIB source can naturally create more conducting layer on the sidewalls of through-holes on the micro-disks. Some sensor design concepts based on micro-fabrication of SiO2 micro-disks utilizing thermally and electrically isolated surfaces are discussed from the viewpoint of applications in photonics and bio-sensing.

Saraf, Laxmikant V↗

Mini-beam collimator enables micro-crystallography experiments on standard beamlines.

The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a 'standard' beam from an undulator source, 25-50 {micro}m (FWHM) in the vertical and 50-100 {micro}m in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 {micro}m x 65 {micro}m at the sample position. To meet growing user demand for beams to study samples of 10 {micro}m or less, a 'mini-beam' apparatus was developed that conditions the focused beam to either 5 {micro}m or 10 {micro}m (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.

36 MATERIALS SCIENCE↗