In-Flight Performance of the Soft X-Ray Spectrometer Detector System on ASTRO-H

The SXS instrument was launched aboard the Astro-H observatory on February 17, 2016. The SXS spectrometer is based on a high sensitivity x-ray calorimeter detector system that has been successfully deployed in many ground and sub-orbital spectrometers. The instrument was to provide essential diagnostics for nearly every class of x-ray emitting objects from the atmosphere of Jupiter to the outskirts of galaxy clusters, without degradation for spatially extended objects. The SXS detector system consisted of a 36-pixel cryogenic microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the detector system demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous band-pass from below 0.3 keV to above 12 keV with a timing precision better than 100 microsecond. In addition, a solid-state anti-coincidence detector was placed directly behind the detector array for background suppression. The detector error budget included the measured interference from the SXS cooling system and the spacecraft. Additional margin for on-orbit gain-stability, and on-orbit spacecraft interference were also included predicting an on-orbit performance that meets or exceeds the 7 eV FWHM at 6 keV requirement. The actual on-orbit spectral resolution was better than 5 eV FWHM at 6 keV, easily satisfying the instrument requirement. Here we discuss the actual on-orbit performance of the SXS detector system and compare this to performance in pre-flight testing and the on-orbit predictions. We will also discuss the on-orbit gain stability, additional on-orbit interference, and measurements of the on-orbit background.

X-ray astrophysics↗

In-Orbit Operation of the ASTRO-H SXS

We summarize all of the in-orbit operations of the soft x-ray spectrometer (SXS) onboard the ASTROH (Hitomi) satellite. The satellite was launched on February 17, 2016, and the communication with the satellite ceased on March 26, 2016. The SXS was still in the commissioning phase, in which the set-ups were progressively changed. This paper is intended to serve as a concise reference of the events in orbit in order to properly interpret the SXS data taken during its short lifetime and as a test case for planning the in-orbit operation for future microcalorimeter missions.

Tsujimoto, Masahiro↗

Design and Development of the Astro-H 3-Stage ADR

The Japanese Astro-H mission will include the Soft X-ray Spectrometer (SXS) instrument provided by NASA/GSFC. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon microcalorimeters operated at 50 mK. The detectors will be cooled by a 3-stage adiabatic demagnetization refrigerator (ADR). The configuration allows the ADR to operate with both a 1.3 K superfluid helium bath and a 4.5 K cryocooler as its heat sink. Initially, when liquid helium is present, the two coldest stages of the ADR will operate in a single-shot mode to cool the detectors from 1.3 K. The 3rd stage may be used to transfer heat from the liquid to the cryocooler to extend its lifetime. When the liquid is depleted, the two warmest stages will operate in a continuous mode to establish a 1.3 K base temperature, from which the cold stage will operate in a single-shot mode to cool the detectors. This paper will describe the design and operating modes of the ADR, as well as details of individual components.

Shirron, Peter J.↗

Magnetic Penetration Effects in Small Superconducting Devices

The temperature dependent behavior of a superconducting body in an applied magnetic field involves flux penetration/expulsion both from screening currents (within a magnetic penetration depth) and variations in the superconducting order parameter (locally to form vortices or a mixed state, or globally in the Meissner effect). The temperature dependence of the magnetic penetration depth, in particular, has been used to make highly sensitive macroscopic thermometers. For the microscopic device volumes required in sensitive low temperature photon detectors, properties of actual thin film materials, non-uniformity of applied magnetic fields, and the influence of measurement circuit dynamics are complicating factors. We discuss the various penetration effects as demonstrated in a particularly promising combination of material and geometry that we have used to make sensitive x-ray microcalorimeters.

Stevenson, T. R.↗

Lynx Mission Concept Status

Lynx is a concept under study for prioritization in the 2020 Astrophysics Decadal Survey. Providing orders of magnitude increase in sensitivity over Chandra, Lynx will examine the first black holes and their galaxies, map the large-scale structure and galactic halos, and shed new light on the environments of young stars and their planetary systems. In order to meet the Lynx science goals, the telescope consists of a high-angular resolution optical assembly complemented by an instrument suite that may include a High Definition X-ray Imager, X-ray Microcalorimeter and an X-ray Grating Spectrometer. The telescope is integrated onto the spacecraft to form a comprehensive observatory concept. Progress on the formulation of the Lynx telescope and observatory configuration is reported in this paper.

Gaskin, Jessica A.↗

In-orbit Operation of the Soft X-Ray Spectrometer Onboard the Hitomi Satellite

We summarize all of the in-orbit operations of the soft x-ray spectrometer (SXS) onboard the ASTRO-H (Hitomi) satellite. The satellite was launched on February 17, 2016, and the communication with the satellite ceased on March 26, 2016. The SXS was still in the commissioning phase, in which the set-ups were progressively changed. This paper is intended to serve as a concise reference of the events in orbit in order to properly interpret the SXS data taken during its short lifetime and as a test case for planning the in-orbit operation for future microcalorimeter missions.

ASTRO-H↗

ADR Design and Operation for the X-Ray Imaging and Spectrometer Mission (XRISM)

Following the loss of the Hitomi x-ray astronomy satellite 38 days after its launch in early 2016, the US and Japanese space agencies (NASA and JAXA) agreed to fund a replacement mission, presently called XARM. XARM will include only the two soft x-ray instruments from Hitomi, the Soft X-ray Spectrometer (SXS), and the Soft X-ray Imager (SXI). For XARM, the spectrometer instrument named Resolve will be rebuilt to the original SXS design. It consists of a 6x6 array of silicon microcalorimeters cooled to 50 millikelvin by means of a 3-stage adiabatic demagnetization refrigerator (ADR) whose operation is supported by a 40 liter superfluid helium tank, a 4.5 K Joule-Thomson cryocooler and a number of 2-stage Stirling cryocoolers. These components were all successfully demonstrated on Hitomi before its failure. This talk will summarize the design of the XARM ADR and how it differs from the SXS version, and will briefly summarize on-orbit ADR performance during Hitomi's operational period.

adiabatic demagnetization refrigeration↗

The Impact of Transition Edge Sensor Design on Achievable Performance Uniformity of Kilo-Pixel Arrays

Future astronomy missions using x-ray transition-edge sensor (TES) microcalorimeters, such as X-IFU on Athena, will require large arrays of 1000s of pixels fabricated on a single wafer. To wire out so many pixels the current array designs have pixels with different rotational orientations. Fabrication is done in multiple layers and so, dependent on method, there is potential for spatial misalignment between layers. Because of the variation of orientation of pixels, misalignment may not impact each pixel equally. This has the potential to degrade the achievable uniformity of performance across an array. How well aligned do different layers need to be? How does sensitivity to misalignment depend on choice of pixel design?

Wakeham, Nicholas↗

Magnetic Calorimeter Arrays with High Sensor Inductance and Dense Wiring

We describe prototype arrays of magnetically coupled microcalorimeters fabricated with an approach scalable to very large format arrays. The superconducting interconnections and sensor coils have sufficiently low inductance in the wiring and sufficiently high inductance in the coils in each pixel, to enable arrays containing greater than 4000 sensors and 100,000 X-ray absorbers to be used in future astrophysics missions such as Lynx. We have used projection lithography to create submicron patterns (e.g., 400-nanometer-lines and spaces) in our niobium sensor coils and wiring, integrated with gold-erbium sensor films and gold X-ray absorbers. Our prototype devices will explore the device physics of metallic magnetic calorimeters as feature sizes are reduced to nanoscale.

Magnetism↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power ($R \sim 100$) and a large bandwidth ($\sim 400$ nm -- $\sim 1.8$ $\mu$m). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors -- fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

In-Flight Calibration of Hitomi Soft X-Ray Spectrometer (3) Effective Area

We present the result of the in-flight calibration of the effective area of the Soft X-ray Spectrometer (SXS) on board the Hitomi X-ray satellite using an observation of the Crab nebula. We corrected for artifacts when observing high count rate sources with the X-ray microcalorimeter. We then constructed a spectrum in the 0.5–20 keV band, which we modeled with a single power-law continuum attenuated by interstellar extinction. We evaluated the systematic uncertainty of the spectral parameters by various calibration items. In the 2–12 keV band, the SXS result is consistent with the literature values in flux (2.20 ± 0.08 × 10(exp −8) erg s(exp-1) cm(exp −2) with a 1 σ statistical uncertainty) but is softer in the power-law index (2.19 ± 0.11). The discrepancy is attributable to the systematic uncertainty of about +6%/−7% and +2%/−5% respectively for the flux and the power-law index. The softer spectrum is affected primarily by the systematic uncertainty of the Dewar gate valve transmission and the event screening.

Tsujimoto, Masahiro↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power (R ~ 100) and a large bandwidth (~ 400 nm – ~ 1.8 µm). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors – fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

3-Stage ADR for the X-Ray Imaging and Spectrometer Mission (XRISM)

Following the loss of the Hitomi x-ray astronomy satellite shortly after its launch in early 2016, the US and Japanese space agencies (NASA and JAXA) agreed to fund a replacement mission, presently called the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM will include only the two soft x-ray instruments from Hitomi, the Soft X-ray Spectrometer (SXS), and the Soft X-ray Imager (SXI). The spectrometer instrument, now named Resolve, will be similar to the original SXS design. It consists of a 6 by 6 array of silicon microcalorimeters cooled to 50 millikelvin by means of a 3-stage Adiabatic Demagnetization Refrigerator (ADR) whose operation is supported by a 40 liter superfluid helium tank, a 4.5-degrees-Kelvin Joule-Thomson cryocooler and a number of 2-stage Stirling cryocoolers. These components were all successfully demonstrated on Hitomi before its failure. This talk will summarize the design of the XRISM ADR and how it differs from the SXS version.

ADR (Adiabatic Demagnetization Refrigerator)↗

High Temperature Superconductor Lead Assemblies for XRISM

The RESOLVE instrument on the upcoming XRISM mission is a rebuild of the SXS instrument that successfully demonstrated high resolution X-ray spectroscopy on the Hitomi mission using a microcalorimeter array at 50 mK. As with SXS, the RESOLVE instrument requires High Temperature Superconductor (HTS) lead assemblies to carry high current to the Adiabatic Demagnetization Refrigerator (ADR) while meeting a very stringent heat conductance budget. For the RESOLVE HTS lead assemblies, we have used new materials and processes to improve the stability and consistency of solder joints to the HTS material. We have also designed a new thermal strap that eliminates stress concentrations on the HTS tapes. We present the results of testing on the engineering model and flight model units, as well as the results of long term testing on prototype solder joints.

Canavan, Edgar R.↗

TES Pixel Optimization for the ATHENA X-IFU Instrument

ATHENA is a European led x-ray observatory due for launch in the early 2030s. The X-ray Integral Field Unit (X-IFU) instrument on ATHENA will have an array of 3168 TES microcalorimeters, 2.5 eV resolution (at 7 keV), 5 arc second angular resolution and a 5 arc minute field of view. As one example, will allow unprecedented views of composition and dynamics of galaxy clusters.

Wakeham, Nick↗

Extension of the energy range accessible with a TES using bath temperature variations

The energy range of transition-edge sensor (TES) X-ray microcalorimeters with a multiplexed readout depends upon the width and shape of the TES superconducting transition, and also on the dynamic range of the readout. In many detector systems, the multiplexed readout slew rate capability will be the limiting factor for the energy range. In these cases, if we are willing to accept some energy resolution degradation, we can significantly extend the energy range by increasing the bath temperature of operation, essentially creating a second “extended energy range” mode of operation. For example, if we require the very highest energy resolution up to 7 keV, and wish to optimize the design up to this energy, for some measurements it could be very beneficial to have a mode where we can extend the energy range to 15–20 keV even if some energy resolution is sacrificed. In this paper, we explore the trade-off between dynamic range and energy resolution from changing the bath temperature of the TES. We present measurements of TES resolution and slew rate as a function of bath temperature and compare to numerical simulations.

S Beaumont↗

SIRENA Software for Athena X-IFU Event Reconstruction

The X-ray Observatory Athena was proposed in April 2014 as the mission to implement the science theme "The Hot and Energetic Universe" selected by ESA for L2 (the second Large-class mission in ESAs Cosmic Vision science programme). One of the two X-ray detectors designed to be onboard Athena is X-IFU, a cryogenic microcalorimeter based on Transition Edge Sensor (TES) technology that will provide spatially resolved high-resolution spectroscopy. X-IFU will be developed by an international consortium led by IRAP (PI), SRON (co-PI) and IAPS/INAF (co-PI) and involving ESA Member States, Japan and the United States. In Spain, IFCA (CSIC-UC) has an anticipated contribution to X-IFU through the Digital Readout Electronics (DRE) unit, in particular in the Event Processor Subsytem. For this purpose and in collaboration with the Athena end-to-end simulations team, we are currently developing the SIRENA package as part of the publicly available SIXTE end-to-end simulator. SIRENA comprises a set of processing algorithms aimed at recognizing, from a noisy signal, the intensity pulses generated by the absorption of the X-ray photons, to lately reconstruct their energy, position and arrival time. This poster describes the structure of the package and the different algorithms currently implemented as well as their comparative performance in the energy resolution achieved in the reconstruction of the instrument events.

M T Ceballos↗

Plasma environment effects on K lines of astrophysical interest II. Ionization potentials, K thresholds, radiative rates, and Auger widths in Ne- through He-like iron ions (Fe xvii – Fe xxv)

Aims. In the context of accretion disks around black holes, we estimate plasma-environment effects on the atomic parameters associated with the decay of K-vacancy states in highly charged iron ions, namely Fe XVII – Fe XXV. Methods. Within the relativistic multiconfiguration Dirac–Fock (MCDF) framework, the electron–nucleus and electron–electron plasma screenings were approximated with a time-averaged Debye–Hückel potential. Results. Modified ionization potentials, K thresholds, wavelengths, radiative emission rates, and Auger widths are reported for astrophysical plasmas characterized by electron temperatures and densities in the ranges 10^5 − 10^7 K and 10^18 − 10^22 per cu.cm, respectively. Conclusions. We conclude that the high-resolution microcalorimeters on board future X-ray missions such as XRISM and ATHENA are expected to be sensitive to the lowering of the iron K edge due to the extreme plasma conditions occurring in accretion disks around compact objects.

J. Deprince↗