Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Nuclear data uncertainty propagation applied to the versatile test reactor conceptual design

We report the Versatile Test Reactor (VTR) currently under development is a 300 MWth sodium-cooled fast reactor (SFR) fueled with ternary metal alloy fuel, which aims to accelerate the testing of advanced nuclear fuels, materials, instrumentation, and sensors in high flux environments that are necessary to license the next generation of advanced reactor concepts. To support the VTR design process, uncertainties associated with the nuclear data has been propagated through the reactor core neutronics calculation to global parameters of interest, such as the core multiplication factor, kinetic parameters, and various reactivity feedback coefficients, following the sensitivity based uncertainty propagation approach. By folding the sensitivity coefficients, separately computed by the generalized perturbation theory code PERSENT and Monte Carlo code Serpent 2, with the variance-covariance matrices from COMMARA-2.0, we obtain the reaction-wise, isotope-wise, and overall uncertainties for each response of interest due to nuclear data uncertainty. With Serpent 2, the statistical error of the uncertainty is obtained by propagating the statistical error of the sensitivity coefficients through the same process using a newly developed uncertainty propagation method. From both codes, the overall top uncertainty contributors are found to be the cross section of Fe-56 elastic scattering, Na-23 elastic scattering, and U 238 inelastic scattering. The large contributions of the Fe-56 elastic scattering cross sections to global parameters are due to its relatively large relative uncertainty of 5–10% in nuclear data and the large volume of Fe-containing reflector assemblies in the fairly compact VTR core design. Both codes agreed well for the overall uncertainty estimates of all responses of interest, except the delayed neutron fraction, prompt neutron generation time, and the coolant density feedback coefficient, where Serpent 2 yielded a much larger value than PERSENT due to the large statistical error of sensitivity coefficients. The calculated uncertainties are also compared to those associated with other SFR cores. Another outcome of this study is a variance-covariance matrix of reactivity coefficients, which can be used in the subsequent uncertainty propagation to the system level to investigate the impact of identified uncertainties on system responses in the safety analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiation Protection Around High-intensity Laser Interactions with Solid Targets

Interaction of a high-intensity optical laser with a solid target can generate an ionizing radiation hazard in the form of high-energy "hot" electrons and bremsstrahlung, resulting from hot electrons interacting with the target itself and the surrounding target chamber. Previous studies have characterized the bremsstrahlung dose yields generated by such interactions for lasers in the range of 10 17 to 10 22 W cm -2 using particle-in-cell code EPOCH and Monte Carlo code FLUKA. Electron measurements based on a depth-dose approach are presented for two laser intensities, which indicate a Maxwellian distribution is more suitable for estimating the hot electrons' energy distribution. Also, transmission factors for the resulting bremsstrahlung for common shielding materials are calculated with FLUKA, and shielding tenth-value-layer thicknesses are also derived. In combination with the bremsstrahlung dose yield, the tenth-value layers provide radiation protection programs the means to evaluate radiation hazards and design shielding for high-intensity laser facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

TOPAS: An innovative proton Monte Carlo platform for research and clinical applications

Purpose: While Monte Carlo particle transport has proven useful in many areas (treatment head design, dose calculation, shielding design, and imaging studies) and has been particularly important for proton therapy (due to the conformal dose distributions and a finite beam range in the patient), the available general purpose Monte Carlo codes in proton therapy have been overly complex for most clinical medical physicists. The learning process has large costs not only in time but also in reliability. To address this issue, we developed an innovative proton Monte Carlo platform and tested the tool in a variety of proton therapy applications. Methods: Our approach was to take one of the already-established general purpose Monte Carlo codes and wrap and extend it to create a specialized user-friendly tool for proton therapy. The resulting tool, TOol for PArticle Simulation (TOPAS), should make Monte Carlo simulation more readily available for research and clinical physicists. TOPAS can model a passive scattering or scanning beam treatment head, model a patient geometry based on computed tomography (CT) images, score dose, fluence, etc., save and restart a phase space, provides advanced graphics, and is fully four-dimensional (4D) to handle variations in beam delivery and patient geometry during treatment. A custom-designed TOPAS parameter control system was placed at the heart of the code to meet requirements for ease of use, reliability, and repeatability without sacrificing flexibility. Results: We built and tested the TOPAS code. We have shown that the TOPAS parameter system provides easy yet flexible control over all key simulation areas such as geometry setup, particle source setup, scoring setup, etc. Through design consistency, we have insured that user experience gained in configuring one component, scorer or filter applies equally well to configuring any other component, scorer or filter. We have incorporated key lessons from safety management, proactively removing possible sources of user error such as line-ordering mistakes. We have modeled proton therapy treatment examples including the UCSF eye treatment head, the MGH stereotactic alignment in radiosurgery treatment head and the MGH gantry treatment heads in passive scattering and scanning modes, and we have demonstrated dose calculation based on patient-specific CT data. Initial validation results show agreement with measured data and demonstrate the capabilities of TOPAS in simulating beam delivery in 3D and 4D. Conclusions: We have demonstrated TOPAS accuracy and usability in a variety of proton therapy setups. As we are preparing to make this tool freely available for researchers in medical physics, we anticipate widespread use of this tool in the growing proton therapy community.

60 APPLIED LIFE SCIENCES↗

Design of water-moderated heterogeneous cores in new STACY facility through JAEA/IRSN collaboration - 14363

In the post-Fukushima prospect, Japan Atomic Energy Agency, JAEA, intends to re-open its Static Experiment Critical Facility STACY, in order to contribute to the validation of fuel debris calculations in conditions close to those affected by the Fukushima Daiichi Nuclear Power Station accident. The reactor core of STACY is being modified by JAEA from homogeneous solution fuel core to heterogeneous pin- type fuel core. The first step of critical experiments is to establish reference experiments involving lattices of UO{sub 2} rods without fuel debris. A design of such experiments is in progress for the widest range of moderation ratios in the frame of JAEA/IRSN collaboration. To anticipate the specification values of materials to be manufactured (grids, rods), an evaluation of uncertainties pertaining to the different parameters driving k{sub eff} is paramount. The following uncertainties of experimental cores are evaluated to estimate the reactivity effect of engineering tolerance/or measurements of the modified STACY: (1) Density of fuel pellets, (2) Enrichment of uranium, (3) Diameter of fuel pellets, (4) Thickness of fuel claddings, (5) Impurities of fuel pellets, (6) Impurities of fuel claddings and (7) Positioning of fuel rods in the lattice. For these calculations, three types of moderation conditions were considered within the experimental parameters of STACY: the lowest moderation (lattice pitch = 1.15 cm; V{sub m}/V{sub f}=1.2), optimum moderation (lattice pitch = 1.5 cm, V{sub m}/V{sub f} = 2.9) and an over moderated case (lattice pitch = 2.55 cm; V{sub m}/V{sub f} = 11). The calculations to derive the overall uncertainty of modified STACY were performed propagating the 1σ uncertainties of parameters of existing STACY in terms of k{sub eff}. For that purpose, a perturbation calculation (differential operator) technique and a stochastic geometry modeling technique were used with the MCNP5 continuous energy Monte Carlo code and a point-wise cross section library based on the JENDL-4.0 evaluated nuclear data library. Moreover, the results of calculations were compared with those calculated by two continuous energy Monte Carlo codes using the correlated sampling technique: - An experimental version of the Japanese MVP2 code combined to the JENDL-4.0 nuclear data library, - The MORET 5 code, developed by IRSN, combined to the JEFF-3.1 nuclear data library. The proposed paper discusses all the aforementioned issues, and confirms that the uncertainty pertaining to the critical experiments of the STACY is sufficiently small. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Facility for Advanced Accelerator Experimental Tests (FACET) at SLAC and its Radiological Considerations

Facility for Advanced Accelerator Experimental Tests (FACET) in SLAC will be used to study plasma wakefield acceleration. FLUKA Monte Carlo code was used to design a maze wall to separate FACET project and LCLS project to allow persons working in FACET side during LCLS operation. Also FLUKA Monte Carlo code was used to design the shielding for FACET dump to get optimum design for shielding both prompt and residual doses, as well as reducing environmental impact. FACET will be an experimental facility that provides short, intense pulses of electrons and positrons to excite plasma wakefields and study a variety of critical issues associated with plasma wakefield acceleration [1]. This paper describes the FACET beam parameters, the lay-out and its radiological issues.

43 PARTICLE ACCELERATORS↗

Advances and future needs in particle production and transport code developments

The next generation of accelerators and ever expanding needs of existing accelerators demand new developments and additions to Monte-Carlo codes, with an emphasis on enhanced modeling of elementary particle and heavy-ion interactions and transport. Challenges arise from extremely high beam energies and beam power, increasing complexity of accelerators and experimental setups, as well as design, engineering and performance constraints. All these put unprecedented requirements on the accuracy of particle production predictions, the capability and reliability of the codes used in planning new accelerator facilities and experiments, the design of machine, target and collimation systems, detectors and radiation shielding and minimization of their impact on environment. Recent advances in widely-used general-purpose all-particle codes are described for the most critical modules such as particle production event generators, elementary particle and heavy ion transport in an energy range which spans up to 17 decades, nuclide inventory and macroscopic impact on materials, and dealing with complex geometry of accelerator and detector structures. Future requirements for developing physics models and Monte-Carlo codes are discussed.

43 PARTICLE ACCELERATORS↗

MO-E-18C-04: Advanced Computer Simulation and Visualization Tools for Enhanced Understanding of Core Medical Physics Concepts

Purpose: Most medical physics programs emphasize proficiency in routine clinical calculations and QA. The formulaic aspect of these calculations and prescriptive nature of measurement protocols obviate the need to frequently apply basic physical principles, which, therefore, gradually decay away from memory. E.g. few students appreciate the role of electron transport in photon dose, making it difficult to understand key concepts such as dose buildup, electronic disequilibrium effects and Bragg-Gray theory. These conceptual deficiencies manifest when the physicist encounters a new system, requiring knowledge beyond routine activities. Methods: Two interactive computer simulation tools are developed to facilitate deeper learning of physical principles. One is a Monte Carlo code written with a strong educational aspect. The code can “label” regions and interactions to highlight specific aspects of the physics, e.g., certain regions can be designated as “starters” or “crossers,” and any interaction type can be turned on and off. Full 3D tracks with specific portions highlighted further enhance the visualization of radiation transport problems. The second code calculates and displays trajectories of a collection electrons under arbitrary space/time dependent Lorentz force using relativistic kinematics. Results: Using the Monte Carlo code, the student can interactively study photon and electron transport through visualization of dose components, particle tracks, and interaction types. The code can, for instance, be used to study kerma-dose relationship, explore electronic disequilibrium near interfaces, or visualize kernels by using interaction forcing. The electromagnetic simulator enables the student to explore accelerating mechanisms and particle optics in devices such as cyclotrons and linacs. Conclusion: The proposed tools are designed to enhance understanding of abstract concepts by highlighting various aspects of the physics. The simulations serve as virtual experiments that give deeper and long lasting understanding of core principles. The student can then make sound judgements in novel situations encountered beyond routine clinical activities.

60 APPLIED LIFE SCIENCES↗

Multigroup Cross-Section Generation with the OpenMC Monte Carlo Particle Transport Code

High-fidelity deterministic transport codes require highly accurate multigroup cross sections (MGXS). Monte Carlo is increasingly cited as a reactor-agnostic approach to MGXS generation since it is unconstrained by the engineering-based approximations that limit the applicability of deterministic MGXS generation tools. This paper introduces a new framework that uses the OpenMC Monte Carlo code to generate MGXS for use in multigroup transport codes. The openmc.mgxs module is built atop OpenMC's Python application programming interface to process tally data output by the OpenMC executable. This paper validates the module to generate MGXS that enable the multigroup OpenMOC transport code to compute eigenvalues to within 50 pcm and fission rates to within 1% of reference solutions for two heterogeneous pressurized water reactor benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent advances and future prospects for Monte Carlo

The history of Monte Carlo methods is closely linked to that of computers: The first known Monte Carlo program was written in 1947 for the ENIAC; a pre-release of the first Fortran compiler was used for Monte Carlo In 1957; Monte Carlo codes were adapted to vector computers in the 1980s, clusters and parallel computers in the 1990s, and teraflop systems in the 2000s. Recent advances include hierarchical parallelism, combining threaded calculations on multicore processors with message-passing among different nodes. With the advances In computmg, Monte Carlo codes have evolved with new capabilities and new ways of use. Production codes such as MCNP, MVP, MONK, TRIPOLI and SCALE are now 20-30 years old (or more) and are very rich in advanced featUres. The former 'method of last resort' has now become the first choice for many applications. Calculations are now routinely performed on office computers, not just on supercomputers. Current research and development efforts are investigating the use of Monte Carlo methods on FPGAs. GPUs, and many-core processors. Other far-reaching research is exploring ways to adapt Monte Carlo methods to future exaflop systems that may have 1M or more concurrent computational processes.

99 GENERAL AND MISCELLANEOUS↗

SU-E-T-761: TOMOMC, A Monte Carlo-Based Planning VerificationTool for Helical Tomotherapy

Purpose: Present a new Monte Carlo code (TOMOMC) to calculate 3D dose distributions for patients undergoing helical tomotherapy treatments. TOMOMC performs CT-based dose calculations using the actual dynamic variables of the machine (couch motion, gantry rotation, and MLC sequences). Methods: TOMOMC is based on the GEPTS (Gama Electron and Positron Transport System) general-purpose Monte Carlo system (Chibani and Li, Med. Phys. 29, 2002, 835). First, beam models for the Hi-Art Tomotherpy machine were developed for the different beam widths (1, 2.5 and 5 cm). The beam model accounts for the exact geometry and composition of the different components of the linac head (target, primary collimator, jaws and MLCs). The beams models were benchmarked by comparing calculated Pdds and lateral/transversal dose profiles with ionization chamber measurements in water. See figures 1–3. The MLC model was tuned in such a way that tongue and groove effect, inter-leaf and intra-leaf transmission are modeled correctly. See figure 4. Results: By simulating the exact patient anatomy and the actual treatment delivery conditions (couch motion, gantry rotation and MLC sinogram), TOMOMC is able to calculate the 3D patient dose distribution which is in principal more accurate than the one from the treatment planning system (TPS) since it relies on the Monte Carlo method (gold standard). Dose volume parameters based on the Monte Carlo dose distribution can also be compared to those produced by the TPS. Attached figures show isodose lines for a H&N patient calculated by TOMOMC (transverse and sagittal views). Analysis of differences between TOMOMC and TPS is an ongoing work for different anatomic sites. Conclusion: A new Monte Carlo code (TOMOMC) was developed for Tomotherapy patient-specific QA. The next step in this project is implementing GPU computing to speed up Monte Carlo simulation and make Monte Carlo-based treatment verification a practical solution.

60 APPLIED LIFE SCIENCES↗

Time Evolving Fission Chain Theory and Fast Neutron and Gamma-Ray Counting Distributions

Here, we solve a simple theoretical model of time evolving fission chains due to Feynman that generalizes and asymptotically approaches the point model theory. The point model theory has been used to analyze thermal neutron counting data. This extension of the theory underlies fast counting data for both neutrons and gamma rays from metal systems. Fast neutron and gamma-ray counting is now possible using liquid scintillator arrays with nanosecond time resolution. For individual fission chains, the differential equations describing three correlated probability distributions are solved: the time-dependent internal neutron population, accumulation of fissions in time, and accumulation of leaked neutrons in time. Explicit analytic formulas are given for correlated moments of the time evolving chain populations. The equations for random time gate fast neutron and gamma-ray counting distributions, due to randomly initiated chains, are presented. Correlated moment equations are given for both random time gate and triggered time gate counting. There are explicit formulas for all correlated moments are given up to triple order, for all combinations of correlated fast neutrons and gamma rays. The nonlinear differential equations for probabilities for time dependent fission chain populations have a remarkably simple Monte Carlo realization. A Monte Carlo code was developed for this theory and is shown to statistically realize the solutions to the fission chain theory probability distributions. Combined with random initiation of chains and detection of external quanta, the Monte Carlo code generates time tagged data for neutron and gamma-ray counting and from these data the counting distributions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. In this work, to respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data.

60 APPLIED LIFE SCIENCES↗

Comparative analysis of energy deposition modes available in Serpent 2 within the framework of the supercritical water reactor - Fuel qualification test reactor physics benchmark

A joint European Canadian Chinese development of a supercritical water-cooled small modular reactor (SCW-SMR) technology is in progress since September 2020 in the framework of a Horizon 2020 project called ECC-SMART. As a main purpose of the project, proper estimates of energy deposition and its spatial distribution are prerequisites for the accurate analysis of safety related parameters of the SCW-SMR concept under development. A supercritical water reactor fuel computational benchmark model, provided by Canadian Nuclear Laboratories, was applied for detailed comparison of different energy deposition calculation options available in the Serpent 2 Monte Carlo code. The effect of energy deposition options on the normalization of the results as well as on the spatial distribution of the energy deposition are discussed. Consistent energy deposition calculation methods are presented between three Monte Carlo codes, viz., Serpent 2, MCNP6 and OpenMC. Although resource-intensive, the use of the coupled neutron-photon transport mode of Serpent 2 is recommended for accurate spatial and quantitative characterization of energy deposition in the SCW-SMR fuel assemblies, accounting for both neutron and photon heating of all the materials. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Interactive Visualization of Multi-Group Cross Sections on High-Fidelity Spatial Meshes

Core simulation tools utilizing Monte Carlo transport methods represent the 'Holy Grail' for nuclear reactor analysis. However, deterministic transport methods pose a number of advantages to Monte Carlo from a computational perspective, which seems likely to make these methods more viable in the near to intermediate term. Deterministic methods almost universally discretize the energy domain in a few to hundreds of energy groups. One of the key challenges for deterministic transport-based methods to be viable is accurate, reactor agnostic multi-group cross section generation. This paper describes tools for data processing and visualization of multigroup cross sections generated on high-fidelity spatial meshes from the OpenMC Monte Carlo code. Next generation deterministic transport reactor core modeling tools will require multi-group cross section (MGXS) generation on high-fidelity spatial meshes. High-fidelity MGXS are necessary for the accurate simulation of neutron physics in nuclear reactors with a high degree of spectral heterogeneity - e.g., large localized neutron flux gradients throughout a reactor core. Although many local (e.g., pin cell) approximations have been developed to model the scalar flux to compute spectral-averaged MGXS, these techniques cannot account for complex intra-pin and intra-assembly spatial self-shielding effects. Monte Carlo presents the most accurate method for reactor agnostic multi-group cross section generation since it does not require the use of local approximations to the flux. Monte Carlo has been proposed as a highly desirable framework for reactor agnostic cross section generation for many years. Monte Carlo methods can effectively embed all of the relevant spectral effects into the MGXS through the random particle tracking and interaction sampling processes. Previous work has applied MCNP and Serpent to compute few-group constants for diffusion calculations, and OpenMC to compute multi-group cross sections for transport-based methods. The primary difficulty with using Monte Carlo for MGXS generation is the tremendous computational resources required to adequately converge multi-group cross sections in each spatial region and energy group. Recent development of the OpenMC Monte Carlo code for high-performance computing platforms has made multigroup cross section generation from Monte Carlo more tractable in the foreseeable future. The recent release of OpenMC v0.7.1 includes a new Python-based module for MGXS generation. The MGXS generation module leverages many of the algorithms and features for 'big data' analysis of large tally datasets on complex spatial meshes. This paper describes the data management workflow and visualization tools which have been developed to explore the plethora of MGXS data generated with OpenMC. It is the authors' hope that the development of the visualization tool described in this paper will ultimately enable the design of machine learning algorithms to accelerate the convergence rate of high-fidelity multi-group cross section generated with Monte Carlo. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Complete Monte Carlo Simulation of Neutron Scattering Experiments

In the far past, it was not possible to accurately correct for the finite geometry and the finite sample size of a neutron scattering set-up. The limited calculation power of the ancient computers as well as the lack of powerful Monte Carlo codes and the limitation in the data base available then prevented a complete simulation of the actual experiment. Using e.g. the Monte Carlo neutron transport code MCNPX [1], neutron scattering experiments can be simulated almost completely with a high degree of precision using a modern PC, which has a computing power that is ten thousand times that of a super computer of the early 1970s. Thus, (better) corrections can also be obtained easily for previous published data provided that these experiments are sufficiently well documented. Better knowledge of reference data (e.g. atomic mass, relativistic correction, and monitor cross sections) further contributes to data improvement. Elastic neutron scattering experiments from liquid samples of the helium isotopes performed around 1970 at LANL happen to be very well documented. Considering that the cryogenic targets are expensive and complicated, it is certainly worthwhile to improve these data by correcting them using this comparatively straightforward method. As two thirds of all differential scattering cross section data of {sup 3}He(n,n){sup 3}He are connected to the LANL data, it became necessary to correct the dependent data measured in Karlsruhe, Germany, as well. A thorough simulation of both the LANL experiments and the Karlsruhe experiment is presented, starting from the neutron production, followed by the interaction in the air, the interaction with the cryostat structure, and finally the scattering medium itself. In addition, scattering from the hydrogen reference sample was simulated. For the LANL data, the multiple scattering corrections are smaller by a factor of five at least, making this work relevant. Even more important are the corrections to the Karlsruhe data due to the inclusion of the missing outgoing self-attenuation that amounts to up to 15%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demonstration of Monte Carlo Reference Equilibrium Core Solutions for Pebble Bed Reactors Using Shift in kugelpy

This report describes how to produce reference solutions for the equilibrium core search of pebble bed reactors using the pyrates Python library. The pyrates library uses the kugelpy methodology to perform running-in calculations to reach an equilibrium core. This approach relies on full-core Monte Carlo neutron transport calculations and the shifting of fuel pebble inventory through the reactor to simulate pebble movement in the core from one step to the next of a running-in scenario. In addition to the use of Serpent for the Monte Carlo neutron transport calculations, as part of this work, updates for the use of the Shift Monte Carlo code were integrated into the official pyrates GitHub repository. Comparisons of running-in simulations for a generic pebble bed reactor produced by using pyrates with Serpent and Shift are shown. Although consistent trends are shown between the use of the two Monte Carlo codes, the limiting factor in either calculation is the computation time due to the need to perform several hundred full-core neutron transport calculations before an equilibrium core is reached.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of Monte Carlo Reference Equilibrium Core Solutions for Pebble Bed Reactors Using Shift in kugelpy

This report describes how to produce reference solutions for the equilibrium core search of pebble bed reactors using the pyrates Python library. The pyrates library uses the kugelpy methodology to perform running-in calculations to reach an equilibrium core. This approach relies on full-core Monte Carlo neutron transport calculations and the shifting of fuel pebble inventory through the reactor to simulate pebble movement in the core from one step to the next of a running-in scenario. In addition to the use of Serpent for the Monte Carlo neutron transport calculations, as part of this work, updates for the use of the Shift Monte Carlo code were integrated into the official pyrates GitHub repository. Comparisons of running-in simulations for a generic pebble bed reactor produced by using pyrates with Serpent and Shift are shown. Although consistent trends are shown between the use of the two Monte Carlo codes, the limiting factor in either calculation is the computation time due to the need to perform several hundred full-core neutron transport calculations before an equilibrium core is reached.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stability analysis of Monte Carlo burnup calculation based on PWR fuel rods

The existing Monte Carlo burnup algorithms may give some unstable results when using multiple burnable cells during burnup calculations. A very small time step is required to maintain the stability of the system, which pose some limits for the realistic applications. In this paper, we firstly repeat the instability issue by using a Monte Carlo code based on a typical PWR fuel rod model. Then, a theoretical stability analysis was carried out by using the perturbation theory in order to get a better understanding about the property of system stability. We determine a perturbation matrix which relates some main influence factors, such as the time step and the height of fuel rod, it can help people estimate the stability of burnup calculation system and the results are quantitatively consistent with the Monte Carlo code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗