Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Tracer particle transport dynamics in the diffusive sandpile cellular automaton

The confinement properties of the diffusive running sandpile are characterized by tracking the motion of a population of marked grains of sand. It is found that, as the relative strength of the avalanching to the diffusive transport channel is varied, a point is reached at which the particle global confinement time and the probability density functions of the jump-sizes and waiting-times of the tracked grains experience a sudden change, thus revealing a dynamical transition, that is consistent with previous studies (Newman DE et al., Phys Rev Lett 2002;88(20):204304). Across this transition, the sandpile moves from a regime characterized by self-similarity and memory, where avalanches of all possible sizes dominate transport across the system, to another regime where transport is taken over by near system-size, quasi-periodic avalanches. Values for the fractional transport exponents that quantify effective transport across the sandpile prior to the transition are also obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Benchmarking a novel ultrasound-CT fusion system for respiratory motion management in radiotherapy: Assessment of spatio-temporal characteristics and comparison to 4DCT

Management of respiratory motion during radiation therapy requires treatment planning and simulation using imaging modalities that possess sufficient spatio-temporal accuracy and precision. An investigation into the use of a novel ultrasound (United States) imaging system for assessment of respiratory motion is presented, exploiting its good soft tissue contrast and temporal precision. The system dynamically superimposes the appropriate image plane sampled from a reference CT data set with the corresponding US B-mode image. An articulating arm is used for spatial registration. While the focus of the study was to quantify the system's ability to track respiratory motion, certain unique spatial calibration procedures were devised that render the software potentially valuable to the general research community. These include direct access to all transformation matrix elements and image scaling factors, a manual latency correction function, and a three-point spatial registration procedure that allows the system to be used in any room possessing a traditional radiotherapy laser localization system. Counter-intuitively, it was discovered that a manual procedure for calibrating certain transformation matrix elements produced superior accuracy to that of an algorithmic Levenberg-Marquardt optimization method. The absolute spatial accuracy was verified by comparing the physical locations of phantom test objects measured using the spatially registered US system, and using data from a 3DCT scan of the phantom as a reference. The spatial accuracy of the display superposition was also tested in a similar manner. The system's dynamic properties were then assessed using three methods. First, the overall system response time was studied using a programmable motion phantom. This included US video update, articulating arm update, CT data set resampling, and image display. The next investigation verified the system's ability to measure the range of motion of a moving anatomical test phantom that possessed both high and low contrast test objects. Finally, the system's performance was compared to that of a four-dimensional CT (4DCT) data set. The absolute spatial and display superposition accuracy was found to be better than 2 mm and typically 1 mm. Overall dynamic system response was adequate to produce a mean relative positional error of less than 1 mm if an empiric latency correction of 3 video frames was incorporated. The dynamic CT/US display mode was able to assess phantom motion for both high and low contrast test objects to within 1 mm, and compared favorably to the 4DCT data. The 4DCT movie loop accurately assessed the target motion for both of the high and low contrast objects tested, but the minimum intensity and average intensity reconstructions did not. This investigation demonstrated that this US system possesses sufficient spatio-temporal accuracy to properly assess respiratory motion. Future work will seek to demonstrate efficacy in its clinical application to respiratory motion assessment, particularly for sites in the upper abdomen, where low tissue contrast is evident.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-163: A Biomechanical Lung Model for Respiratory Motion Study

Purpose: This work presents a biomechanical model to investigate the complex respiratory motion for the lung tumor tracking in radiosurgery by computer simulation. Methods: The models include networked massspring-dampers to describe the tumor motion, different types of surrogate signals, and the force generated by the diaphragm. Each mass-springdamper has the same mechanical structure and each model can have different numbers of mass-spring-dampers. Both linear and nonlinear stiffness parameters were considered, and the damping ratio was tuned in a range so that the tumor motion was over-damped (no natural tumor oscillation occurs without force from the diaphragm). The simulation was run by using ODE45 (ordinary differential equations by Runge-Kutta method) in MATLAB, and all time courses of motions and inputs (force) were generated and compared. Results: The curvature of the motion time courses around their peaks was sensitive to the damping ratio. Therefore, the damping ratio can be determined based on the clinical data of a high sampling rate. The peak values of different signals and the time the peaks occurred were compared, and it was found that the diaphragm force had a time lead over the tumor motion, and the lead time (0.1–0.4 seconds) depended on the distance between the tumor and the diaphragm. Conclusion: We reported a model based analysis approach for the spatial and temporal relation between the motion of the lung tumor and the surrogate signals. Due to the phase lead of the diaphragm in comparing with the lung tumor motion, the measurement of diaphragm motion (or its electromyography signal) can be used as a beam gating signal in radiosurgery, and it can also be an additional surrogate signal for better tumor motion tracking. The research is funded by the American Cancer Society (ACS) grant. The grant name is: Frameless SRS Based on Robotic Head Motion Cancellation. The grant number is: RSG-13-313-01-CCE.

60 APPLIED LIFE SCIENCES↗

DYNAMICAL EVIDENCE FOR A MAGNETOCENTRIFUGAL WIND FROM A 20 M{sub Sun} BINARY YOUNG STELLAR OBJECT

In Orion BN/KL, proper motions of {lambda}7 mm vibrationally excited SiO masers trace the rotation of a nearly edge-on disk and a bipolar wide-angle outflow 10-100 AU from radio source I, a binary young stellar object of {approx}20 M{sub Sun }. Here we map ground-state {lambda}7 mm SiO emission with the Very Large Array and track proper motions over 9 yr. The innermost and strongest emission lies in two extended arcs bracketing Source I. The proper motions trace a northeast-southwest bipolar outflow 100-1000 AU from Source I with a median three-dimensional motion of {approx}18 km s{sup -1}. An overlying distribution of {lambda}1.3 cm H{sub 2}O masers betrays similar flow characteristics. Gas dynamics and emission morphology traced by the masers suggest the presence of a magnetocentrifugal disk wind. Reinforcing evidence lies in the colinearity of the flow, apparent rotation across the flow parallel to the disk rotation, and recollimation that narrows the flow opening angle {approx}120 AU downstream. The arcs of ground-state SiO emission may mark the transition point to a shocked super-Alfvenic outflow.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-AB-202-01: Daily Lung Tumor Motion Characterization On EPIDs Using a Markerless Tiling Model

Purpose: Tracking lung tumor motion in real time allows for target dose escalation while simultaneously reducing dose to sensitive structures, thus increasing local control without increasing toxicity. We present a novel intra-fractional markerless lung tumor tracking algorithm using MV treatment beam images acquired during treatment delivery. Strong signals superimposed on the tumor significantly reduced the soft tissue resolution; while different imaging modalities involved introduce global imaging discrepancies. This reduced the comparison accuracies. A simple yet elegant Tiling algorithm is reported to overcome the aforementioned issues. Methods: MV treatment beam images were acquired continuously in beam’s eye view (BEV) by an electronic portal imaging device (EPID) during treatment and analyzed to obtain tumor positions on every frame. Every frame of the MV image was simulated by a composite of two components with separate digitally reconstructed radiographs (DRRs): all non-moving structures and the tumor. This Titling algorithm divides the global composite DRR and the corresponding MV projection into sub-images called tiles. Rigid registration is performed independently on tile-pairs in order to improve local soft tissue resolution. This enables the composite DRR to be transformed accurately to match the MV projection and attain a high correlation value through a pixel-based linear transformation. The highest cumulative correlation for all tile-pairs achieved over a user-defined search range indicates the 2-D coordinates of the tumor location on the MV projection. Results: This algorithm was successfully applied to cine-mode BEV images acquired during two SBRT plans delivered five times with different motion patterns to each of two phantoms. Approximately 15000 beam’s eye view images were analyzed and tumor locations were successfully identified on every projection with a maximum/average error of 1.8 mm / 1.0 mm. Conclusion: Despite the presence of strong anatomical signal overlapping with tumor images, this markerless detection algorithm accurately tracks intrafractional lung tumor motions. This project is partially supported by an Elekta research grant.

60 APPLIED LIFE SCIENCES↗

Relative role of motion and PSF compensation in whole-body oncologic PET-MR imaging

Purpose: Respiratory motion and partial-volume effects are the two main sources of image degradation in whole-body PET imaging. Simultaneous PET-MR allows measurement of respiratory motion using MRI while collecting PET events. Improved PET images may be obtained by modeling respiratory motion and point spread function (PSF) within the PET iterative reconstruction process. In this study, the authors assessed the relative impact of PSF modeling and MR-based respiratory motion correction in phantoms and patient studies using a whole-body PET-MR scanner. Methods: An asymmetric exponential PSF model accounting for radially varying and axial detector blurring effects was obtained from point source acquisitions performed in the PET-MR scanner. A dedicated MRI acquisition protocol using single-slice steady state free-precession MR acquisitions interleaved with pencil-beam navigator echoes was developed to track respiratory motion during PET-MR studies. An iterative ordinary Poisson fully 3D OSEM PET reconstruction algorithm modeling all the physical effects of the acquisition (attenuation, scatters, random events, detectors efficiencies, PSF), as well as MR-based nonrigid respiratory deformations of tissues (in both emission and attenuation maps) was developed. Phantom and{sup 18}F-FDG PET-MR patient studies were performed to evaluate the proposed quantitative PET-MR methods. Results: The phantom experiment results showed that PSF modeling significantly improved contrast recovery while limiting noise propagation in the reconstruction process. In patients with soft-tissue static lesions, PSF modeling improved lesion contrast by 19.7%–109%, enhancing the detectability and assessment of small tumor foci. In a patient study with small moving hepatic lesions, the proposed reconstruction technique improved lesion contrast by 54.4%–98.1% and reduced apparent lesion size by 21.8%–34.2%. Improvements were particularly important for the smallest lesion undergoing large motion at the lung-liver interface. Heterogeneous tumor structures delineation was substantially improved. Enhancements offered by PSF modeling were more important when correcting for motion at the same time. Conclusions: The results suggest that the proposed quantitative PET-MR methods can significantly enhance the performance of tumor diagnosis and staging as compared to conventional methods. This approach may enable utilization of the full potential of the scanner in oncologic studies of both the lower abdomen, with moving lesions, as well as other parts of the body unaffected by motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Defect Creation and Motion on the Thermodynamics and Large-Scale Reorganization of Self-Assembled Clathrin Lattices

We develop a theoretical model for the thermodynamics and kinetics of clathrin self-assembly. Our model addresses the behavior in two dimensions and can be easily extended to three dimensions, facilitating the study of membrane, surface, and bulk assembly. The clathrin triskelia are modeled as flexible pinwheels that form leg-leg associations and resist bending and stretching deformations. Thus, the pinwheels are capable of forming a range of ring structures, including 5-, 6-, and 7-member rings that are observed experimentally. Our theoretical model employs Brownian dynamics to track the motion of clathrin pinwheels at sufficiently long time scales to achieve complete assembly. Invoking theories of dislocation-mediated melting in two dimensions, we discuss the phase behavior for clathrin self-assembly as predicted by our theoretical model. We demonstrate that the generation of 5-7 defects in an otherwise perfect honeycomb lattice resembles creation of two dislocations with equal and opposite Burgers vectors. We use orientational- and translational-order correlation functions to predict the crystalline-hexatic and hexatic-liquid phase transitions in clathrin lattices. These results illustrate the pivotal role that molecular elasticity plays in the physical behavior of self-assembling and self-healing materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-AB-303-11: Verification of a Deformable 4DCT Motion Model for Lung Tumor Tracking Using Different Driving Surrogates

Purpose: Tumor tracking is an advanced technique to treat intra-fractionally moving tumors. The aim of this study is to validate a surrogate-driven model based on four-dimensional computed tomography (4DCT) that is able to predict CT volumes corresponding to arbitrary respiratory states. Further, the comparison of three different driving surrogates is evaluated. Methods: This study is based on multiple 4DCTs of two patients treated for bronchial carcinoma and metastasis. Analyses for 18 additional patients are currently ongoing. The motion model was estimated from the planning 4DCT through deformable image registration. To predict a certain phase of a follow-up 4DCT, the model considers for inter-fractional variations (baseline correction) and intra-fractional respiratory parameters (amplitude and phase) derived from surrogates. In this evaluation, three different approaches were used to extract the motion surrogate: for each 4DCT phase, the 3D thoraco-abdominal surface motion, the body volume and the anterior-posterior motion of a virtual single external marker defined on the sternum were investigated. The estimated volumes resulting from the model were compared to the ground-truth clinical 4DCTs using absolute HU differences in the lung volume and landmarks localized using the Scale Invariant Feature Transform (SIFT). Results: The results show absolute HU differences between estimated and ground-truth images with median values limited to 55 HU and inter-quartile ranges (IQR) lower than 100 HU. Median 3D distances between about 1500 matching landmarks are below 2 mm for 3D surface motion and body volume methods. The single marker surrogates Result in increased median distances up to 0.6 mm. Analyses for the extended database incl. 20 patients are currently in progress. Conclusion: The results depend mainly on the image quality of the initial 4DCTs and the deformable image registration. All investigated surrogates can be used to estimate follow-up 4DCT phases, however uncertainties decrease for three-dimensional approaches. This work was funded in parts by the German Research Council (DFG) - KFO 214/2.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-10: Update On a Real-Time Treatment Guidance System Using An IR Navigation System for Pleural PDT

Purpose: Photodynamic therapy (PDT) is used in conjunction with surgical debulking of tumorous tissue during treatment for pleural mesothelioma. One of the key components of effective PDT is uniform light distribution. Currently, light is monitored with 8 isotropic light detectors that are placed at specific locations inside the pleural cavity. A tracking system with real-time feedback software can be utilized to improve the uniformity of light in addition to the existing detectors. Methods: An infrared (IR) tracking camera is used to monitor the movement of the light source. The same system determines the pleural geometry of the treatment area. Software upgrades allow visualization of the pleural cavity as a two-dimensional volume. The treatment delivery wand was upgraded for ease of light delivery while incorporating the IR system. Isotropic detector locations are also displayed. Data from the tracking system is used to calculate the light fluence rate delivered. This data is also compared with in vivo data collected via the isotropic detectors. Furthermore, treatment volume information will be used to form light dose volume histograms of the pleural cavity. Results: In a phantom study, the light distribution was improved by using real-time guidance compared to the distribution when using detectors without guidance. With the tracking system, 2D data can be collected regarding light fluence rather than just the 8 discrete locations inside the pleural cavity. Light fluence distribution on the entire cavity can be calculated at every time in the treatment. Conclusion: The IR camera has been used successfully during pleural PDT patient treatment to track the motion of the light source and provide real-time display of 2D light fluence. It is possible to use the feedback system to deliver a more uniform dose of light throughout the pleural cavity.

60 APPLIED LIFE SCIENCES↗

Insights into Rotational and Translational Dynamics in Mixtures of Ethylene Glycol and Choline Chloride Using Nuclear Magnetic Resonance Techniques

This work examines molecular dynamics and interactions in ethylene glycol–choline chloride (EG–ChCl) mixtures across 0–33 mol % ChCl, spanning the true eutectic region near 17–20 mol % and the commonly used 1:2 formulation. We combine pulsed-field-gradient (PFG) diffusion, fast-field-cycling (FFC) relaxometry, temperature-dependent 13 C T 1 , and nuclear Overhauser effect spectroscopy (NOESY) to disentangle local from macroscopic dynamics. PFG and FFC show that both translational and average rotational motions largely track the strong increase in viscosity with ChCl content, with ethylene glycol consistently diffusing faster than the choline cation and no global dynamical anomaly at the eutectic composition. More subtle, site-specific composition effects nevertheless emerge. The ratio of the diffusion coefficient of the hydroxyl group of choline to the diffusion coefficient of the methyl group of choline displays a shallow minimum in the 17–25 mol % region, indicating a modest change in how the hydroxyl-bearing end of choline samples the underlying translational motion relative to the methyl groups. 13 C T 1 analysis shows that rotational correlation times at 25 °C generally increase with ChCl, reflecting viscosity-coupled slowing, while the CH 2 –N α site exhibits a small but reproducible deviation from this monotonic trend near the eutectic. NOESY spectra at similar compositions reveal enhanced cross-relaxation between EG and choline protons, consistent with increased headgroup–solvent contact density rather than a wholesale structural rearrangement. Overall, our multitechnique study demonstrates that EG–ChCl dynamics are predominantly viscosity-dominated, with the eutectic region acting as a subtle dynamical crossover where specific choline segments become maximally coupled to the hydrogen-bond network. These insights refine the structure–dynamics picture of choline-chloride DESs and provide practical guidance for tuning composition in electrochemical, separation, and catalytic applications.

diffusion↗

TH-CD-207A-09: Stay On Target: Dynamic, Patient-Specific Templates of Fiducial Marker Clusters for IGRT

Purpose: Pancreatic SBRT relies on extremely accurate delivery of ablative radiation doses to the target, and intra-fractional tracking of fiducial markers can facilitate improvements in dose delivery. However, this requires algorithms that are able to find fiducial markers with high speed and accuracy. The purpose of this study was to develop a novel marker tracking algorithm that is robust against many of the common errors seen with traditional template matching techniques. Methods: Using CBCT projection images, a method was developed to create detailed template images of fiducial marker clusters without prior knowledge of the number of markers, their positions, or their orientations. Briefly, the method (i) enhances markers in projection images, (ii) stabilizes the cluster’s position, (iii) reconstructs the cluster in 3D, and (iv) precomputes a set of static template images dependent on gantry angle. Furthermore, breathing data were used to produce 4D reconstructions of clusters, yielding dynamic template images dependent on gantry angle and breathing amplitude. To test these two approaches, static and dynamic templates were used to track the motion of marker clusters in more than 66,000 projection images from 75 CBCT scans of 15 pancreatic SBRT patients. Results: For both static and dynamic templates, the new technique was able to locate marker clusters present in projection images 100% of the time. The algorithm was also able to correctly locate markers in several instances where only some of the markers were visible due to insufficient field-of-view. In cases where clusters exhibited deformation and/or rotation during breathing, dynamic templates resulted in cross-correlation scores up to 70% higher than static templates. Conclusion: Patient-specific templates provided complete tracking of fiducial marker clusters in CBCT scans, and dynamic templates helped to provide higher cross-correlation scores for deforming/rotating clusters. This novel algorithm provides an extremely accurate method to detect fiducial markers during treatment. Research funding provided by Varian Medical Systems to Miften and Jones.

60 APPLIED LIFE SCIENCES↗

OBSERVATIONAL EVIDENCE OF PARTICLE ACCELERATION ASSOCIATED WITH PLASMOID MOTIONS

We report a strong association between the particle acceleration and plasma motions found in the 2010 August 18 solar flare. The plasma motions are tracked in the extreme ultraviolet (EUV) images taken by the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamics Observatory and the Extreme UltraViolet Imager (EUVI) on the Solar Terrestrial Relations Observatory spacecraft Ahead , and the signature of particle acceleration was investigated by using Nobeyama Radioheliograph data. In our previous paper, we reported that in EUV images many plasma blobs appeared in the current sheet above the flare arcade. They were ejected bidirectionally along the current sheet, and the blobs that were ejected sunward collided with the flare arcade. Some of them collided or merged with each other before they were ejected from the current sheet. We discovered impulsive radio bursts associated with such plasma motions (ejection, coalescence, and collision with the post flare loops). The radio bursts are considered to be the gyrosynchrotron radiation by nonthermal high energy electrons. In addition, the stereoscopic observation by AIA and EUVI suggests that plasma blobs had a three-dimensionally elongated structure. We consider that the plasma blobs were three-dimensional plasmoids (i.e., flux ropes) moving in a current sheet. We believe that our observation provides clear evidence of particle acceleration associated with the plasmoid motions. We discuss possible acceleration mechanisms on the basis of our results.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetohydrodynamics and Heat Transfer in a Free-Surface, Flowing Liquid Metal Experiment

This thesis examines magnetohydrodynamic (MHD) effects and heat transfer in free-surface, liquid metal flow. The interaction of the flow with the applied magnetic field introduces an anisotropy to the fluid motion, resulting in starkly different behavior depending on the orientation and strength of the applied magnetic field. The transition from a hydrodynamic state to an MHD state was experimentally found to be characterized by the interaction parameter, N = &sigma L B 2 /&rho v0 , crossing above 0.5. The experiment consisted of a channel 1 m in length, up to 16 cm in width and 1 to 2.5 cm in depth situated within an electromagnet capable of producing a uniform magnetic field up to 2.7 kG. The fluid velocity was measured with an array of 25 potential probes that resolved the spanwise velocity profile, while waves on the surface of the metal were monitored via a diagnostic that tracked the motion of a laser beam reflected off of the free surface. Lastly, the temperature response of the fluid was recorded with an array of 32 thermocouples embedded in the bottom of the channel and a mid-wavelength infrared camera used to image the free surface. Three distinct sets of experiments were performed to investigate the effects of the applied magnetic field on the dynamics within the flow, studying: 1) changes to vortices in the wake of a cylinder, 2) behavior of surface fluctuations due to the turbulent flow, and 3) vertical heat transfer resulting from heat deposition on the free surface. The first set of experiments examined the wake of a cylinder inserted into the flow with its axis parallel to the magnetic field. Measurements with the potential probes indicated that vortices in the wake became laminarized as the field was increased due to the alignment of the injected vorticity with the applied field. The second set of experiments showed that surface fluctuations were suppressed at high magnetic fields, but the precise nature of the damping depended on the orientation of the applied field. Lastly, when heat was injected at the free surface via a resistive heater, the temperature response of the fluid was found to vary considerably depending on the strength and direction of the applied field. In all experiments, it was observed that the angle between the vorticity of structures in the flow and the applied magnetic field dictated the macroscopic behavior of the fluid. This work provides the first experimental results of several phenomena associated with free-surface, liquid metal flows in an applied magnetic field. Further, the results have direct implications for proposed flowing liquid metal divertors for fusion reactors, and offer insight into the nature of turbulent MHD flows.

fusion↗

SU-E-T-183: Clinical Quality Assurance Workflow for Dynamic Tumor Tracking Radiation Dose Delivery

Purpose: One of the most important aspects of implementation of new treatment modalities is an ‘end-to-end’ verification of the treatment process. Radiation treatment based on dynamic tracking of a tumor is highly patient-specific, therefore, special attention should be paid to quality assurance of the treatment delivery. Our goal was to design the clinical workflow that ensures accurate delivery of the planned dose using the Dynamic Target Tracking option of VeroTM (BrainLab,MHI) linac. Methods: A patient simulation is designed to include a pre-treatment session to verify whether the system can reliably track the motion of the implanted marker and build the 4D model of the target motion. The external surrogate and target motion patterns are recorded in the ExactracTM log files. In this work, a spectrum of custom marker and external surrogate motion trajectories closely resembling the patient specific motion patterns was used. 1mm thick/11mm long VisicoilTM marker was placed 15 and 20mm from the center of the spherical tissue equivalent target (centroid to centroid distance) in the 4D motion phantom (CIRSTM). 3D conformal (3 mm block margin) SBRT plans were delivered to 2 moving targets in the phantom: 1) 20mm diameter target that allows ion chamber dose measurement and 2) 25mm target that allows using film to measure CAX dose (GafchromicTM EBT3 used). The measured dose was compared to the iPlanTM TPS results using MonteCarlo algorithm (1% variance, Dose-to-water). Results: On average, film shows 98.9% pass using gamma criterion for 2% and 2mm DTA, 94.3% match for 2% and 1 mm DTA, 98% pass for 1% and 2 mm DTA however only 88% points passing for 1% and 1 mm DTA. Ion chamber measurements agreed with the calculation within 1.5%. Conclusion: The clinical QA workflow was designed for SBRT delivery using real-time tumor tracking on VeroTM linac.

60 APPLIED LIFE SCIENCES↗

Optimum value of original events on the PEPT technique

Do Positron emission particle tracking (PEPT) has been used to track the motion of a single radioactively labeled tracer particle within a bed of similar particles. In this paper, the effect of the original event fraction on the results precise in two experiments has been reviewed. Results showed that the algorithm can no longer distinguish some corrupt trajectories, in addition to; further iteration reduces the statistical significance of the sample without improving its quality. Results show that the optimum value of trajectories depends on the type of experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

European sea bass show behavioural resilience to near-future ocean acidification

Ocean acidification (OA)-caused by rising concentrations of carbon dioxide (CO 2 )-is thought to be a major threat to marine ecosystems and has been shown to induce behavioural alterations in fish. Here we show behavioural resilience to near-future OA in a commercially important and migratory marine finfish, the Sea bass (Dicentrarchus labrax). Sea bass were raised from eggs at 19 °C in ambient or near-future OA (1000 μatm pCO 2 ) conditions and n = 270 fish were observed 59-68 days post-hatch using automated tracking from video. Fish reared under ambient conditions, OA conditions, and fish reared in ambient conditions but tested in OA water showed statistically similar movement patterns, and reacted to their environment and interacted with each other in comparable ways. Thus our findings indicate behavioural resilience to near-future OA in juvenile sea bass. Moreover, simulated agent-based models indicate that our analysis methods are sensitive to subtle changes in fish behaviour. Lastly, it is now important to determine whether the absences of any differences persist under more ecologically relevant circumstances and in contexts which have a more direct bearing on individual fitness.

54 ENVIRONMENTAL SCIENCES↗

TU-H-CAMPUS-TeP2-01: A Comparison of Noninvasive Techniques to Assess Radiation-Induced Lung Damage in Mice

Purpose: To evaluate the use of post-irradiation changes in respiratory rate and CBCT-based morphology as predictors of survival in mice. Methods: C57L/J mice underwent whole-thorax irradiation with a Co-60 beam to four different doses [0Gy (n=3), 9Gy (n=5), 11Gy (n=7), and 13Gy (n=5)] in order to induce varying levels of pneumonitis. Respiratory rate measurements, breath-hold CBCTs, and free-breathing CBCTs were acquired pre-irradiation and at six time points between two and seven months post-irradiation. For respiratory rate measurements, we developed a novel computer-vision-based technique. We recorded mice sleeping in standard laboratory cages with a 30 fps, 1080p webcam (Logitech C920). We calculated respiratory rate using corner detection and optical flow to track cyclical motion in the fur in the recorded video. Breath-hold and free-breathing CBCTs were acquired on the X-RAD225Cx system. For breathhold imaging, the mice were intubated and their breath was held at full-inhale for 20 seconds. Healthy lung tissue was delineated in the scans using auto-threshold contouring (0–0.7 g/cm{sup 3}). The volume of healthy lung was measured in each of the scans. Next, lung density was measured in a 6-mm{sup 2} ROI in a fixed anatomic location in each of the scans. Results: Day-to-day variability in respiratory rate with our technique was 13%. All metrics except for breath-hold lung volume were correlated with survival: lung density on free-breathing (r=−0.7482,p<0.01) and breath-hold images (r=−0.5864,p<0.01), free-breathing lung volume (r=0.7179,p<0.01), and respiratory rate (r= 0.6953,p<0.01). Lung density on free-breathing scans was correlated with respiratory rate (r=0.7142,p<0.01) and lung density on breath-hold scans (r=0.5543,p<0.01). One significant practical hurdle in the CBCT measurements was that at least one lobe of the lung was collapsed in 36% of free-breathing scans and 45% of breath-hold scans. Conclusion: Lung density and lung volume on free-breathing CBCTs and respiratory rate outperform breath-hold CBCT measurements as indicators for survival from radiation-induced pneumonitis. This work was partially funded by Elekta.

60 APPLIED LIFE SCIENCES↗

Potential benefits of dosimetric VMAT tracking verified with 3D film measurements

Purpose: To evaluate three different plan adaptation strategies using 3D film-stack dose measurements of both focal boost and hypofractionated prostate VMAT treatments. The adaptation strategies (a couch shift, geometric tracking, and dosimetric tracking) were applied for three realistic intrafraction prostate motions. Methods: A focal boost (35 × 2.2 and 35 × 2.7 Gy) and a hypofractionated (5 × 7.25 Gy) prostate VMAT plan were created for a heterogeneous phantom that allows for internal prostate motion. For these plans geometric tracking and dosimetric tracking were evaluated by ionization chamber (IC) point dose measurements (zero-D) and measurements using a stack of EBT3 films (3D). The geometric tracking applied translations, rotations, and scaling of the MLC aperture in response to realistic prostate motions. The dosimetric tracking additionally corrected the monitor units to resolve variations due to difference in depth, tissue heterogeneity, and MLC-aperture. The tracking was based on the positions of four fiducial points only. The film measurements were compared to the gold standard (i.e., IC measurements) and the planned dose distribution. Additionally, the 3D measurements were converted to dose volume histograms, tumor control probability, and normal tissue complication probability parameters (DVH/TCP/NTCP) as a direct estimate of clinical relevance of the proposed tracking. Results: Compared to the planned dose distribution, measurements without prostate motion and tracking showed already a reduced homogeneity of the dose distribution. Adding prostate motion further blurs the DVHs for all treatment approaches. The clinical practice (no tracking) delivered the dose distribution inside the PTV but off target (CTV), resulting in boost dose errors up to 10%. The geometric and dosimetric tracking corrected the dose distribution’s position. Moreover, the dosimetric tracking could achieve the planned boost DVH, but not the DVH of the more homogeneously irradiated prostate. A drawback of both the geometric and dosimetric tracking was a reduced MLC blocking caused by the rotational component of the MLC aperture corrections. Because of the used CTV to PTV margins and the high doses in the considered fractionation schemes, the TCP differed less than 0.02 from the planned value for all targets and all correction methods. The rectal NTCP constraints, however, could not be realized using any of these methods. Conclusions: The geometric and dosimetric tracking use only a limited input, but they deposit the dose distribution with higher geometric accuracy than the clinical practice. The latter case has boost dose errors up to 10%. The increased accuracy has a modest impact [Δ(NT)CP < 0.02] because of the applied margins and the high dose levels used. To allow further margin reduction tracking methods are vital. The proposed methodology could further be improved by implementing a rotational correction using collimator rotations.

60 APPLIED LIFE SCIENCES↗