Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Neutron inelastic scattering measurements on Xe 136 at E n = 0.7 to 100 MeV

Experiments searching for neutrinoless double ${\beta}$ decay ($0{\nu}{\beta}{\beta}$) require precise energy calibration and extremely low backgrounds. One of the most popular isotopes for $0{\nu}{\beta}{\beta}$ experiments is $^{136}\mathrm{Xe}$. In support of these experiments, the neutron inelastic scattering properties of this isotope have been measured at the GErmanium Array for Neutron Induced Excitations (GEANIE) at the Los Alamos Neutron Science Center. Time-of-flight techniques are utilized with high-purity germanium detectors to search for inelastic scattering ${\gamma}$ rays for neutron energies between 0.7 and 100 MeV. Limits are set on production of yet-unobserved ${\gamma}$ rays in the energy range critical for $0{\nu}{\beta}{\beta}$ studies, and measurements are made of multiple ${\gamma}$-ray production cross sections. In particular, we have measured the production of the 1313 keV ${\gamma}$ ray, which comes from the transition of the first-excited to ground state of $^{136}\mathrm{Xe}$. This neutron-induced ${\gamma}$ line may be useful for a novel energy calibration technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments with neutron induced neutron emission from U-235, Pu-239, and graphite

A neutron induced neutron emission experiment was conducted as the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory (LANL). In this experiment, a sample was placed in a well collimated neutron beam and was surrounded by an array of 28 fast neutron detectors (EJ-309). The experiment was performed with a neutron flight path of 21.5 m from the source to the sample, and 1 m from the sample to the detectors. The neutron emission from the sample was measured as a function of neutron time of flight covering an incident energy range from 0.7- 20 MeV. The samples included U-235, Pu-239, carbon (graphite), and blanks that matched the encapsulation of the sample. The measured samples were constantly cycled in and out of the neutron beam. This type of experiment measures neutron emission from all reactions occurring in the sample such as fission and elastic and inelastic scattering. Similar to the methodology previously developed at RPI, the measurements were compared with detailed simulations of the experiment using different cross section evaluations for the sample. The observed differences can be attributed to the evaluated neutron cross section and angular distributions. The carbon sample was used as a reference to validate both the experiment and simulation methodology and showed good agreement between experiments and simulations. A review of the experimental setup, analysis methods, and some of the results will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Looking back at 50 years of cutting-edge capabilities: LANSCE ‘underpins Los Alamos as a world-class scientific institution’

What started with an idea and a memo has since grown into a one-of-a-kind, world-renowned facility that contributes to the nation’s advancement of science and technology. First known as LAMPF (Los Alamos Meson Physics Facility) until the 1990s when it became LANSCE (Los Alamos Neutron Science Center), the facility is celebrating the 50th anniversary of its first full-capacity proton beam on June 9, 1972. Since then, LANSCE has contributed to a range of national security goals, such as supporting the Lab’s stockpile stewardship program, helping to advance the science of medical radioisotopes, improving the understanding of hydrodynamics, and more. “LANSCE has served the nation through its near-unique capabilities,” said Alan Carr, Senior Historian at the National Security Research Center, which houses the facility’s evolution through decades of documents, photos and other materials. “Since 1972, LANSCE has been the Lab’s major experimental science facility and underpins Los Alamos as a world-class scientific institution. This was true 50 years ago and is still true today.” In commemoration of this anniversary, we’re taking a look back at LANSCE’s historic five decades, including its first director, earliest milestones and important contributions to national security.

43 PARTICLE ACCELERATORS↗

Radiation-Induced Noise Resilience of Neuromorphic Architectures

Neuromorphic event-based networks use asynchronous time-dependent information to extract features from input data that can allow for edge-based distributed applications such as object recognition. The noise resilience properties of such networks, especially in the context of space applications, are yet to be explored. In this paper, we use the hierarchy of time surfaces (HOTS) algorithm, which is one of the neuromorphic algorithms, to understand the least and most resilient modules in a neuromorphic network. The HOTS algorithm relies on the computing of time surfaces that maps the temporal delays between neighboring pixels into normalized features that involve many computations that are also found in other neuromorphic networks such as exponential decays, distance computations, etcetera. We implemented HOTS on a Digilent PYNQ board with a Xilinx Zynq 7020 system on a chip, and we subjected the boards running the HOTS network inference to neutron radiation at the Los Alamos Neutron Science Center. Furthermore, we used simulation models from our previous similar experiments on the event-based sensor to create a neutron induced noise model to quantify the effect of this noise on the overall performance of the network. This experiment provides the preliminary measurements of the reliability of the HOTS algorithm and proposes methods to create a more reliable HOTS architecture in future spacecraft missions.

Engineering↗

Fission Cross Section Measurements of Actinides at LANSCE

Fission cross sections of a range of actinides have been measured at the Los Alamos Neutron Science Center (LANSCE) in support of nuclear energy applications. By combining measurement at two LANSCE facilities, Lujan Center and the Weapons Neutron Research center (WNR), differential cross sections can be measured from sub-thermal energies up to 200 MeV. Incident neutron energies are determined using the time-of-flight method, and parallel-plate ionization chambers are used to measure fission cross sections relative to the 235 U standard. Recent measurements include the 233,238 U, 239,242 Pu and 243 Am neutron-induced fission cross sections. In this paper preliminary results for cross section data of 243 Am and 233 U will be presented.

07 ISOTOPE AND RADIATION SOURCES↗

Fission Cross Section Measurements of Actinides at LANSCE

Fission cross sections of a range of actinides have been measured at the Los Alamos Neutron Science Center (LANSCE) in support of nuclear energy applications. By combining measurement at two LANSCE facilities, Lujan Center and the Weapons Neutron Research center (WNR), differential cross sections can be measured from sub-thermal energies up to 200 MeV. Incident neutron energies are determined using the time-of-flight method, and parallel-plate ionization chambers are used to measure fission cross sections relative to the 235U standard. Recent measurements include the 233, 238U, 239-242Pu, and 243Am neutron-induced fission cross sections. In this paper preliminary results for fission cross sections of 243Am and 233U will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Fresh Nuclear Fuel using Time-Of-Flight Neutrons

Neutrons offer excellent characterization capabilities for nuclear fuels and can provide non-destructive insight on micro structure, chemistry and crystallographic phase. Measurements are possible at reactors or pulsed sources, but the inherent energy resolution implicit at pulsed sources offers unique opportunities. Recent advances in 2D neutron detection enabled new capabilities of material characterization using neutron imaging and tomography for nuclear materials. Moreover, time-of-flight (TOF) neutron measurements can enable isotope specific tomography by deriving isotope densities from transmission spectra exhibiting neutron resonances, which are recorded for each pixel. Tomographic algorithms allow 3D reconstructions of the spatial distribution of isotopes, density and features in typical fuel pellet samples. The ability to select radiographs for different energies allows characterizing samples which are opaque for thermal neutrons, such as enriched fuels or fuels containing plutonium, by selecting epi-thermal neutron energies and by knowledge of the total neutron cross sections of the constituents, isotopic enrichment levels can be determined. Nuclear cross sections are typically not calculated directly and databases such as the Evaluated Nuclear Data File (ENDF) database provide this information with cross sections determined by standardized experimental measurements, such as neutron transmission measurements for individual isotopes. Utilizing the information in the ENDF database, the 'inverse' problem can be solved by assuming cross section parameters to be known parameters and areal densities can be determined. This work presents recent advances at the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory (LANL), which provides the infrastructure to handle radioactive samples, in the development of fuel characterization with TOF neutrons. Examples include recent work on prototype accident tolerant nuclear fuels (ATF). The potential application of these techniques for nondestructive examination of irradiated fuel is under consideration. Non-destructive access to materials features for specimens embedded in containers, particularly for hazardous samples, such as a radioactive nuclear fuel, is indispensable to characterize and ultimately license new fuel forms. Energy-resolve neutron imaging is a new tool for this research field. The results reported here present a new imaging technique, setting a milestone in the capabilities of measuring non-destructively absolute quantities of physical properties. The enabling physics behind this new technique are nuclear resonances. We have demonstrated how absolute areal densities can be extracted from radiographs utilizing pulsed neutron sources. This technique provides information that is otherwise difficult and costly to obtain. In the case of nuclear fuels, the results from energy-dispersive neutron imaging may guide destructive examination of irradiated fuel. This summery does not describe recent analysis, which is ongoing. Particularly, the implementation of calibration standards has improved the determination of enrichment levels without additional calibration. The analysis of the samples was performed with full tomographic reconstructions for isotope specific data and presents a first approach in absolute isotope specific 3D reconstruction. This work was predominantly funded by and received substantial support from the Fuel Cycle R and D program at Los Alamos National Laboratory. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance of Large Neutron Detectors Containing Lithium-Gadolinium-Borate Scintillator

This paper describes the development and testing of a neutron counter, spectrometer, and dosimeter that is compact, efficient, and accurate. A self-contained neutron detection instrument has wide applications in health physics, scientific research, and programs to detect, monitor, and control strategic nuclear materials (SNM). The 1.3 liter detector head for this instrument is a composite detector with an organic scintillator containing uniformly distributed {sup 6}Li{sub 6}{sup nat}Gd{sup 10}B{sub 3}O{sub 9}:Ce (LGB:Ce) microcrystals. The plastic scintillator acts to slow impinging neutrons and emits light proportional to the energy lost by the neutrons as they moderate in the detector body. Moderating neutrons that have slowed sufficiently capture in one of the Lithium-6, Boron-10, or Gadolinium-157 atoms in the LGB:Ce scintillator, which then releases the capture energy in a characteristic cerium emission pulse. The measured captured pulses indicate the presence of neutrons. When a scintillating fluor is present in the plastic, the light pulse resulting from the neutron moderating in the plastic is paired with the LGB:Ce capture pulse to identify the energy of the neutron. About 2% of the impinging neutrons lose all of their energy in a single collision with the detector. There is a linear relationship between the pulse areas of this group of neutrons and energy. The other 98% of neutrons have a wide range of collision histories within the detector body. When these neutrons are 'binned' into energy groups, each group contains a distribution of pulse areas. This data was used to assist in the unfolding of the neutron spectra. The unfolded spectra were then validated with known spectra, at both neutron emitting isotopes and fission/accelerator facilities. Having validated spectra, the dose equivalent and dose rate are determined by applying standard, regulatory damage coefficients to the measured neutron counts for each energy bin of the spectra. Testing at the Los Alamos Neutron Science Center (LANSCE), Edwards Accelerator Laboratory (EAL) at Ohio University and the Radiation Center at University of Massachusetts-Lowell has demonstrated that the instrument can measure neutrons and their spectra over the range between 0.8 MeV and 150 MeV with an uncertainty of only ± 8%. An independent test of the LGB:Ce neutron spectrometer was conducted by a US Defense Threat Reduction Agency (DTRA) team at the Idaho National Laboratory (INL). The results of this evaluation showed that the neutron spectrometer accurately identified bare radioactive isotopes by their spectra. Further, masking and shielding materials alter those spectra in predictable ways that permit an extrapolation from the observed spectra back to the identity of the isotopic spectrum. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Resonance Spin Determination Using Multi-Segmented Detector DANCE

A sensitive method to determine the spin of neutron resonances is introduced based on the statistical pattern recognition technique. The new method was used to assign the spins of s-wave resonances in {sup 155}Gd. The experimental neutron capture data for these nuclei were measured with the DANCE (Detector for Advanced Neutron Capture Experiment) calorimeter at the Los Alamos Neutron Science Center. The highly segmented calorimeter provided detailed multiplicity distributions of the capture {gamma}-rays. Using this information, the spins of the neutron capture resonances were determined. With these new spin assignments, level spacings are determined separately for s-wave resonances with J{sup {pi}} = 1{sup -} and 2{sup -}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solid-solid phase transition measurements in iron

Previously, dynamic experiments on iron have observed a non-zero transition time and width in the solid-solid {alpha}-{var_epsilon} phase transition. Using Proton Radiography at the Los Alamos Neutron Science Center, we have performed plate impact experiments on iron to further study the {alpha}-{var_epsilon} phase transition which occurs at 13GPa. A 40mm bore powder gun was coupled to a proton radiography beam line and imaging system and synchronized to the impact of the projectile on the target sample with the proton beam pattern. A typical experimental configuration for the iron study, as shown below in 3 color-enhanced radiographs, is a 40mm diameter aluminum sabot impacting a 40mm diameter of polycrystalline ARMCO iron. The iron is backed by a sapphire optical window for velocimetry measurements. The aluminum flyer on the left of the iron is barely visible for visual display purposes. Direct density jumps were measured which corresponded to calculations to within 1% using a Wondy mUlti-phase equation of state model. In addition, shock velocities were measured using an edge fitting technique and followed that edge movement from radiograph to radiograph, where radiographs are separated in time by 500 ns. Preliminary measurements give a shock velocity (P1 wave) of 5.251 km/s. The projectile velocity was 0.725 km/s which translate to a peak stress of 17.5 GPa. Assuming the P1 wave is instantaneous, we are able to calibrate the chromatic, motion, object and camera blur by measuring the width of the P1 wave. This approximation works in this case since each of the two density jumps are small compared to the density of the object. Subtracting the measured width of the P1 wave in quadrature from the width of the P2 wave gives a preliminary measurement of the transition length of 265 {mu}m. Therefore, a preliminary measured phase transition relaxation time {tau} = transition length/u{sub s} = 265 {mu}m/5.251 km/s = 50 ns. Both Boettger and Jensen conclude that the transition rate and likely the transition mechanisms depend on the impact stress and the sample thickness. Since Proton Radiography can measure directly the transition length as well as the shock velocity, a transition time can be directly calculated. With higher higher energy protons we have better resolution of the measured width and edge locations. This will allow a more precise measurement of phase transition relaxation time. We propose to perform a series of experiments to measure the phase transition relaxation time, {tau}, as a function of drive and sample size.

36 MATERIALS SCIENCE↗

Determination of the parahydrogen fraction in a liquid hydrogen target using energy-dependent slow neutron transmission

In this study, the NPDGamma collaboration is performing a measurement of the very small parity-violating asymmetry in the angular distribution of the 2.2 MeV γ-rays from the capture of polarized cold neutrons on protons (A γ ). The estimated size of A γ is 5×10 -8 , and the measured asymmetry is proportional to the neutron polarization upon capture. Since the interaction of polarized neutrons with one of the two hydrogen molecular states (orthohydrogen) can lead to neutron spin-flip scattering, it is essential that the hydrogen in the target is mostly in the molecular state that will not depolarize the neutrons (≥99.8% parahydrogen). For that purpose, in the first stage of the NPDGamma experiment at the Los Alamos Neutron Science Center (LANSCE), we operated a 16-l liquid hydrogen target, which was filled in two different occasions. The parahydrogen fraction in the target was accurately determined in situ by relative neutron transmission measurements. The result of these measurements indicate that the fraction of parahydrogen in equilibrium was 0.9998±0.0002 in the first data taking run and 0.9956±0.0002 in the second. We describe the parahydrogen monitor system, relevant aspects of the hydrogen target, and the procedure to determine the fraction of parahydrogen in the target. In addition, assuming thermal equilibrium of the target, we extract the scattering cross-section for neutrons on parahydrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolved texture and microstructure evolution of additively manufactured and gas gun deformed 304L stainless steel investigated by neutron diffraction and electron backscatter diffraction

In this study, we report the characterization of a 304L stainless steel cylindrical projectile produced by additive manufacturing. The projectile was compressively deformed using a Taylor Anvil Gas Gun, leading to a huge strain gradient along the axis of the deformed cylinder. Spatially resolved neutron diffraction measurements on the HIgh Pressure Preferred Orientation time-of-flight diffractometer (HIPPO) and Spectrometer for Materials Research at Temperature and Stress diffractometer (SMARTS) beamlines at the Los Alamos Neutron Science CEnter (LANSCE) with Rietveld and single-peak analysis were used to quantitatively evaluate the volume fractions of the α, γ, and ε phases as well as residual strain and texture. The texture of the γ phase is consistent with uniaxial compression, while the α texture can be explained by the Kurdjumov–Sachs relationship from the γ texture after deformation. This indicates that the material first deformed in the γ phase and subsequently transformed at larger strains. The ε phase was only found in volumes close to the undeformed material with a texture connected to the γ texture by the Shoji–Nishiyama orientation relationship. This allows us to conclude that the ε phase occurs as an intermediate phase at lower strain, and is superseded by the α phase when strain increases further. Furthe, we found a proportionality between the root-mean-squared microstrain of the γ phase, dominated by the dislocation density, with the α volume fraction, consistent with strain-induced martensite α formation. In conclusion, knowledge of the sample volume with the ε phase from the neutron diffraction analysis allowed us to identify the ε phase by electron back scatter diffraction analysis, complementing the neutron diffraction analysis with characterization on the grain level.

304L stainless steel↗

Irradiation Environment of the Materials Test Station

Conceptual design of the proposed Materials Test Station (MTS) at the Los Alamos Neutron Science Center (LANSCE) is now complete. The principal mission is the irradiation testing of advanced fuels and materials for fast-spectrum nuclear reactor applications. The neutron spectrum in the fuel irradiation region of MTS is sufficiently close to that of fast reactor that MTS can match the fast reactor fuel centerline temperature and temperature profile across a fuel pellet. This is an important characteristic since temperature and temperature gradients drive many phenomena related to fuel performance, such as phase stability, stoichiometry, and fission product transport. The MTS irradiation environment is also suitable in many respects for fusion materials testing. In particular, the rate of helium production relative to atomic displacements at the peak flux position in MTS matches well that of fusion reactor first wall. Nuclear transmutation of the elemental composition of the fusion alloy EUROFER97 in MTS is similar to that expected in the first wall of a fusion reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmarking of the MCNPX predictions of the neutron time-emission spectra at LANSCE - 25332

We currently operate Mark-III generation of the spallation neutron target-moderator-reflector-shield (TMRS) assembly at the Manuel Lujan Jr. Neutron Scattering Center of the Los Alamos Neutron Science Center (LANSCE). Mark-III is scheduled for replacement with the next-generation TMRS Mark-IV in 2020. Mark-IV enhances the neutronic performance in the eV-MeV energy range by increasing intensity and improving energy resolution. The increased eV-MeV neutron flux, together with the elevated gamma-ray background, has implications for the radiation shielding of the neutron flight paths and scientific instruments. To update the shielding design, we need to maintain a thoroughly benchmarked MCNPX model of the entire TMRS assembly. In this article we use our detailed MCNPX model of Mark-III to calculate the neutron time-emission spectra. With these spectra we generate the resolution function for SAMMY calculations of capture cross section in {sup 197}Au in the resonance region between 70 eV and 1 keV. We compare the calculated data with the experimental data measured with the DANCE instrument using the neutron time-of-flight technique. We show that our current model predicts measurements accurately and thus provides a solid base for developing the radiation shielding design of the new TMRS assembly. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Neutron radiation hardness testing of 650V / 7.5 A GaN power HEMT

In this work, we have performed neutron radiation hardness testing for commercially available 650 V/7.5 A GaN power HEMT. The devices were tested at Los Alamos Neutron Science Center (LANSCE) inside Irradiation of Chips Electronics, ICE house-1 at a flux density of 10(6) n/cm(2) -s and energy level above 1 MeV, which is approximately 10(6) times higher than neutron radiation at airliner flight height (30,000 ft). During the experiments, the devices were stressed electrically, thermally and irradiated with neutron radiation. We have observed degradation of AlGaN layer due to accelerated neutron radiation (1.54 x 10(10) n/cm(2) above 1.5 MeV neutron energy) under electrical stress condition. We have performed parametric defect analysis through step-by-step application of neutron irradiation, thermal stress and electrical bias, and observed highest degradation of threshold voltage (0.14 V) for combined electrical stress and neutron irradiation.

36 MATERIALS SCIENCE↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ortho-para convertors, an aluminum cryostat, an aluminum target vessel shielded with {sup 6}Li-rich plastic, a hydrogen fill/vent line with a passive recirculation loop to establish and maintain the equilibrium ortho-para ratio, a hydrogen relief system coupled to a vent stack, a gas handling system, and an alarm and interlock system. Low Z, nonmagnetic materials were used for the target vessel and cryostat. Pressure and temperature sensors monitored the thermodynamic state of the target. Relative neutron transmission measurements were used to monitor the parahydrogen fraction of the target. The target was thoroughly tested and successfully operated during the first phase of the NPDGamma experiment conducted at the FP12 beam line at Los Alamos Neutron Science Center (LANSCE). An upgraded version of the target system will be used in the next stage of the experiment, which will be performed at the Fundamental Neutron Physics Beam (FnPB) line of the Spallation Neutron Source at Oak Ridge National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A liquid VI scintillator cell for fast-gated neutron imaging

Here, the design of a new fast-gated neutron imaging system for the National Ignition Facility with much stricter timing constraints than a previous system has prompted the search for a fast scintillator material that can be used in imaging. A novel imaging cell based on Liquid VI has recently been developed with Eljen Technology and characterized at the Special Technologies Laboratory and the Los Alamos Neutron Science Center. The results show superior timing characteristics and spatial resolution, and sufficient light production for the new system compared to fast plastic scintillators previously used in neutron imaging. While the primary application is in inertial confinement fusion diagnostics, the imaging cell can be used in any fast-gated imaging application where timing characteristics and spatial resolution are of concern.

47 OTHER INSTRUMENTATION↗