Search NASA⌕ Search

SEARCH · Search NASA

Results for “NOISE THRESHOLD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The convective noise floor for the spectroscopic detection of low mass companions to solar type stars

The threshold mass for the unambiguous spectroscopic detection of low mass companions to solar type stars is defined here as the time when the maximum acceleration in the stellar radial velocity due to the Doppler reflex of the companion exceeds the apparent acceleration produced by changes in convection. An apparent acceleration of 11 m/s/yr in integrated sunlight was measured using near infrared Fourier transform spectroscopy. This drift in the apparent solar velocity is attributed to a lessening in the magnetic inhibition of granular convection as solar minimum approaches. The threshold mass for spectroscopic detection of companions to a one solar mass star is estimated at below one Jupiter mass.

Deming, D.↗

Noise-canceling quantum feedback: Non-Hermitian dynamics with applications to state preparation and magic state distillation

Time-continuous quantum measurement allows for the tracking of a quantum system in real time via sequences of short, and individually weak, measurement intervals. Such measurements are necessarily invasive, imparting backaction to the system, and allowing the observer to update their state estimate based on stochastic measurement outcomes. Feedback control then involves real-time interventions by an observer, conditioned on the time-continuous measurement signal that they receive. Here, we consider here diffusive quantum trajectories and focus on the “noise-canceling” subset of feedback protocols that aim to minimize the degree of stochasticity in the dynamics. We derive such a class of feedback operations, showing that under the idealized assumptions of pure states, unit measurement efficiency, and zero time delay in implementing feedback operations, perfectly noise-canceling feedback always exists. We consider the resulting noise-canceled dynamics generated by an effective non-Hermitian Hamiltonian; while non-Hermitian Hamiltonians from continuous monitoring generally describe rare dynamics (accessible by costly postselection), the use of noise-canceling feedback here leads to non-Hermitian dynamics that occur deterministically. We demonstrate this via examples of entangled state preparation and stabilization. We then illustrate the potential for the application of noise cancellation to boost success rates in magic state distillation protocols. We show that adding feedback based on noise cancellation into a time-continuous five-to-one distillation protocol leads to higher probabilities of successful distillation across a range of input errors and increases the threshold on input errors for which the protocol is effective. Our results highlight the efficacy of noise-canceling feedback-aided protocols for quantum state preparation and stabilization tasks.

Karmakar, Tathagata [University of California, Ber↗

Noise-induced hearing impairment and handicap

A permanent, noise-induced hearing loss has doubly harmful effect on speech communications. First, the elevation in the threshold of hearing means that many speech sounds are too weak to be heard, and second, very intense speech sounds may appear to be distorted. The whole question of the impact of noise-induced hearing loss upon the impairments and handicaps experienced by people with such hearing losses was somewhat controversial partly because of the economic aspects of related practical noise control and workmen's compensation.

Source record↗

Constraining Warm Dark Matter and Population III Stars with the Global 21 cm Signal

Upcoming ground- and space-based experiments may have sufficient accuracy to place significant constraints upon high-redshift star formation, Reionization, and dark matter (DM) using the global 21 cm signal of the intergalactic medium. In the early universe, when the relative abundance of low-mass DM halos was important, measuring the global signal would place constraints on the damping of structure formation caused by DM having a higher relic velocity (warm dark matter, or WDM) than in cold dark matter. Such damping, however, can be mimicked by altering the star formation efficiency (SFE) and can be difficult to detect because of the presence of Population III stars with unknown properties. We study these various cases and their degeneracies with the WDM mass parameter mX using a Fisher matrix analysis. We study the mX = 7 keV case and a star formation model that parameterizes the SFE as a strong function of halo mass and include several variations of this model along with three different input noise levels for the likelihood; we also use a minimum halo virial temperature for collapse near the molecular cooling threshold. We find that when the likelihood includes only Population II stars, mX is constrained to an uncertainty of ∼0.4 keV for all models and noise levels at the 68% confidence level. When the likelihood includes weak Population III stars, mX ∼ 0.3 keV, and if Population III star formation is relatively efficient, mX ∼ 0.1 keV uncertainty, with tight Population III star formation parameter constraints. Our results show that the global 21 cm signal is a promising test-bed for WDM models, even in the presence of strong degeneracies with astrophysical parameters.

Cosmology↗

Cardinal: Seismic and Geoacoustic Array Processing

Data collected via seismic and infrasound array deployments are leveraged in the geosciences to detect and characterize a myriad of natural and anthropogenic sources. These deployments consist of numerous sensors placed in a predetermined configuration to amplify signal strength and improve the efficacy of array processing techniques used to measure signal directionality and waveform coherence. High‐fidelity feature extraction is often predicated on interstation distance as well as the frequency content and wavelength of an incident signal. Numerous array processing softwares analyze data in sequential frequency bands to obtain a more detailed characterization of a signal. However, current algorithms are limited in their ability to determine optimal array configuration for each band. We introduce an open‐source Python code, called Cardinal, to process seismic and infrasound array data in discretized time–frequency space with the option of applying an adaptive array design to determine optimal subarray configuration for each frequency band. To reduce computational time, the array processing step can be run in parallel using multithreading. Furthermore, the software has the capability to aggregate array processing results from different time–frequency pixels to produce separate sets of detections, or families, with added utility via the application of an adaptive semblance threshold, which aids in isolating signals‐of‐interest from coherent background noise. Upon appropriate configuration, Cardinal exhibits the potential to combine distinct seismic and infrasound phases into separate families.

Adaptive Array↗

Threshold computations for detection of failures in SISO systems with transfer function errors

The author considers the problem of detecting failures in SISO systems using analytic redundancy concepts. Since the models used are subject to error, a method of determining the detection thresholds that account for these errors is sought. The methodology presented utilizes a straightforward application of Parseval's relation to develop a threshold computation that is performed online as a function of the input signal. The threshold is set at a quiescent value to account for sensor noise and is adjusted (upward) according to the activity of the input signal. An application to detection of actuator failures is presented.

Weiss, Jerold L.↗

Noise measurements obtained during visual approach monitor evaluation in 747 aircraft

The results are reported of acoustic measurements made on the 747 aircraft during visual approach monitor evaluation approaches. This display is designed to improve approach and landing precision under visual flight rule conditions. The purpose of the acoustic portion of the test was to measure, evaluate, and identify the noise levels during various types of aircraft approaches. Six noise measurement sites were positioned on the centerline of the approach ground track. The six noise measurement stations on the approach ground track were positioned between approximately 1 and 6 nautical miles from runway threshold. The 1-nautical mile point was chosen as the beginning of the ground track because it is specified as the approach measurement point in the FAA noise certification requirements. The 6-nautical mile point was chosen for its proximity to the point where the approach is initiated.

Tanner, C. S.↗

On operation and control of CW magnetrons for superconducting accelerators

CW magnetrons, developed for industrial RF heaters, were suggested to feed RF cavities of superconducting accelerators due to higher efficiency and lower cost of RF power than provide traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF auto generators with a huge regenerative gain. This causes regenerative instability with a notable noise when a magnetron operates as an auto generator i.e., with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for phase stabilization of magnetrons. In this case CW magnetrons with the injection-locked (coherent) oscillations generate a notable level of noise. This may preclude use of CW magnetrons in this mode in the Superconducting RF (SRF) accelerators. This paper reviews PIC modeling and previously obtained experimental results for the operation and control of CW magnetrons, which led to the development of techniques most suitable for various SRF accelerators using forced RF oscillation of magnetrons, when the magnetron is launched by an injected forcing signal, and regenerative noise is suppressed.

Kazakevich, G. [MUONS Inc., Batavia] (ORCID:000000↗

Silent Aircraft Initiative Concept Risk Assessment

A risk assessment of the Silent Aircraft Initiative's SAX-40 concept design for extremely low noise has been performed. A NASA team developed a list of 27 risk items, and evaluated the level of risk for each item in terms of the likelihood that the risk would occur and the consequences of the occurrence. The following risk items were identified as high risk, meaning that the combination of likelihood and consequence put them into the top one-fourth of the risk matrix: structures and weight prediction; boundary-layer ingestion (BLI) and inlet design; variable-area exhaust and thrust vectoring; displaced-threshold and continuous descent approach (CDA) operational concepts; cost; human factors; and overall noise performance. Several advanced-technology baseline concepts were created to serve as a basis for comparison to the SAX-40 concept. These comparisons indicate that the SAX-40 would have significantly greater research, development, test, and engineering (RDT&E) and production costs than a conventional aircraft with similar technology levels. Therefore, the cost of obtaining the extremely low noise capability that has been estimated for the SAX-40 is significant. The SAX-40 concept design proved successful in focusing attention toward low noise technologies and in raising public awareness of the issue.

Nickol, Craig L.↗

Hearing loss in space

BACKGROUND: Temporary and, in some cases, permanent hearing loss has been documented after long-duration spaceflights. METHODS: We examined all existing published data on hearing loss after space missions to characterize the losses. RESULTS: Data from Russian missions suggest that the hearing loss, when it occurs, affects mainly mid to high frequencies and that using hearing protection often might prevent the loss. Several significant questions remain about hearing loss in space. While the hearing loss has been presumed to be noise-induced, no clear link has been established between noise exposure and hearing loss during spaceflight. In one documented case of temporary hearing loss from the Shuttle-Mir program, the pattern of loss was atypical for a noise-induced loss. Continuous noise levels that have been measured on the Mir and previous space stations, while above engineering standards, are not at levels usually associated with hearing loss in ground-based studies (which have usually been limited to 8-10 h exposure periods). Attempts to measure hearing in space using threshold-based audiograms have been unsuccessful in both the American and Russian programs due to noise interference with the measurements. CONCLUSIONS: The existing data highlight the need for reliable monitoring of both hearing and noise in long-duration spaceflight.

manned↗

Mathematical Morphological Filtering with a Self-Adaptive Reconstruction Technique and Application to Local Seismic Data

Recorded seismic data are generally contaminated by noise from different sources, which masks the signals of interest. In the seismology community, frequency filtering (FF) is the standard method for noise suppression. However, when the signal of interest and noise share the same frequency band, the latter cannot be filtered out without infringing on the former. We implemented a noise suppression approach based on the mathematical morphology theorem. The method involves compound operations of dilation and erosion using structuring elements of varying lengths and decomposes an input noisy waveform into several time functions with differing characteristics. Further, the filtered waveform is constructed from the time functions using a self-adaptive reconstruction technique. Application to a data set of >4700 local waveforms suggests that the implemented mathematical morphological filtering (MMF) approach is efficient for data with low signal-to-noise ratio (SNR) and significantly outperforms FF in that SNR range. For most of the dataset, FF, machine learning (ML) denoising, and continuous wavelet transform (CWT) thresholding result in higher SNR values compared with the MMF method. However, for ~42% of the waveforms, MMF outperforms FF, and the SNR gain achieved with MMF is as large as ~23 dB. Compared to ML denoising and CWT thresholding, this proportion drops to only ~10%–14%. Our results suggests that in an operational setting, MMF cannot replace the other noise suppression methods; however, signal detection can be improved if MMF is used to supplement them in some scenarios. MMF could help detect signals in problematic low-SNR data, which are currently being missed particularly when using FF alone.

58 GEOSCIENCES↗

Acoustic Issues in Human Spaceflight

NASA is concerned about acute effect of sound on crew performance on International Space Station (ISS), and is developing strategies to assess and reduce acute, chronic, and delayed effects of sound. High noise levels can cause headaches, irritation, fatigue, impaired sleep, headache, and tinnitus and have resulted in an inability to hear alarms. Speech intelligibility may be more impaired for crew understanding non-native language in a noisy environment. No hearing loss occurred, but significant effects on crew performance and communication occurred. Permanent Threshold Shifts (PTS) have not been observed in the US shuttle program. Russian specification for noise in spacecraft is 60 dBA (awake) and 50 dBA (asleep) while the U.S. noise specification on ISS is NC 50 (awake) and NC 40 (asleep) with a 85 dBA hazard limit. Background noise levels of ISS modules have measured 56-69 dBA. Treadmill exercise operations measure 77 dBA. Alarms are required to be 20 dBA above ambient. Hearing protection is recommended when noise exceeds 60 dB 24 hour Leq. Countermeasures include hearing protection and design/ engineering controls. Advanced composite materials with excellent low frequency attenuation properties could be applied as a barrier protection around noisy equipment, or used on personal protective equipment worn by the crew. Hearing protection countermeasures include foam ear inserts, passive muff headsets, and active noise reduction headsets. Oto-acoustic emissions (OAE) could be used to monitor effectiveness of hearing protection countermeasures and tailor hearing protection countermeasures to individual crewmembers. Micro-gravity, vibration, toxic fumes, air quality/composition, stress, temperature, physical exertion or some combination of the above factors may have interacted with moderate long-term noise exposure to cause significant hearing loss. Longitudinal studies will need to address what co-morbidity factors, such as radiation, toxicology, microgravity effects (fluid shift), aging, are involved with hearing loss.

Clark, Jonathan B.↗

Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain's ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable and provides imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles. SR using imperceptible stochastic electrical stimulation of the vestibular system (stochastic vestibular stimulation, SVS) applied to normal subjects has shown to improve the degree of association between the weak input periodic signals introduced via venous blood pressure receptors and the heart-rate responses. Also, application of SVS over 24 hours improves the long-term heart-rate dynamics and motor responsiveness as indicated by daytime trunk activity measurements in patients with multi-system atrophy, Parkinson s disease, or both, including patients who were unresponsive to standard therapy for Parkinson s disease. Recent studies conducted at the NASA JSC Neurosciences Laboratories showed that imperceptible SVS, when applied to normal young healthy subjects, leads to significantly improved balance performance during postural disturbances on unstable compliant surfaces. These studies have shown the benefit of SR noise characteristic optimization with imperceptible SVS in the frequency range of 0-30 Hz, and amplitudes of stimulation have ranged from 100 to 400 microamperes.

Bloomberg, Jacob↗

Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/ sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain s ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable providing imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles.

Bloomberg, Jacob↗

Measurements and observations of noise from a 4.2 megawatt (WTS-4) wind turbine generator

Noise measurements and calculations are being made for large wind turbine generators to develop a data base for use in designing and siting such systems for community acceptance. As part of this program, measurements were made on the WTS-4 wind turbine generator during its acceptance runs. This paper presents the results of these exploratory measurements for power output conditions in the range 1.0 to 4.2 MW. Data include noise levels, spectra, radiation patterns, effects of distance, and the associated perception thresholds for use in the further development of acceptance criteria for this type of machine.

Shepherd, K. P.↗

Quantum noise and squeezing in optical parametric oscillator with arbitrary output coupling

The redistribution of intrinsic quantum noise in the quadratures of the field generated in a sub-threshold degenerate optical parametric oscillator exhibits interesting dependences on the individual output mirror transmittances, when they are included exactly. We present a physical picture of this problem, based on mirror boundary conditions, which is valid for arbitrary transmittances. Hence, our picture applies uniformly to all values of the cavity Q factor representing, in the opposite extremes, both perfect oscillator and amplifier configurations. Beginning with a classical second-harmonic pump, we shall generalize our analysis to the finite amplitude and phase fluctuations of the pump.

Prasad, Sudhakar↗

Remote Sensing Time Series Product Tool

The TSPT (Time Series Product Tool) software was custom-designed for NASA to rapidly create and display single-band and band-combination time series, such as NDVI (Normalized Difference Vegetation Index) images, for wide-area crop surveillance and for other time-critical applications. The TSPT, developed in MATLAB, allows users to create and display various MODIS (Moderate Resolution Imaging Spectroradiometer) or simulated VIIRS (Visible/Infrared Imager Radiometer Suite) products as single images, as time series plots at a selected location, or as temporally processed image videos. Manually creating these types of products is extremely labor intensive; however, the TSPT development tool makes the process simplified and efficient. MODIS is ideal for monitoring large crop areas because of its wide swath (2330 km), its relatively small ground sample distance (250 m), and its high temporal revisit time (twice daily). Furthermore, because MODIS imagery is acquired daily, rapid changes in vegetative health can potentially be detected. The new TSPT technology provides users with the ability to temporally process high-revisit-rate satellite imagery, such as that acquired from MODIS and from its successor, the VIIRS. The TSPT features the important capability of fusing data from both MODIS instruments onboard the Terra and Aqua satellites, which drastically improves cloud statistics. With the TSPT, MODIS metadata is used to find and optionally remove bad and suspect data. Noise removal and temporal processing techniques allow users to create low-noise time series plots and image videos and to select settings and thresholds that tailor particular output products. The TSPT GUI (graphical user interface) provides an interactive environment for crafting what-if scenarios by enabling a user to repeat product generation using different settings and thresholds. The TSPT Application Programming Interface provides more fine-tuned control of product generation, allowing experienced programmers to bypass the GUI and to create more user-specific output products, such as comparison time plots or images. This type of time series analysis tool for remotely sensed imagery could be the basis of a large-area vegetation surveillance system. The TSPT has been used to generate NDVI time series over growing seasons in California and Argentina and for hurricane events, such as Hurricane Katrina.

Predos, Don↗