Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neck initiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Scalable fabrication of micron-scale graphene nanomeshes for high-performance supercapacitor applications

Graphene nanomeshes (GNMs) with nanoscale periodic or quasi-periodic nanoholes have attracted considerable interest because of unique features such as their open energy band gap, enlarged specific surface area, and high optical transmittance. These features are useful for applications in semiconducting devices, photocatalysis, sensors, and energy-related systems. We report on the facile and scalable preparation of multifunctional micron-scale GNMs with high-density of nanoperforations by catalytic carbon gasification. The catalytic carbon gasification process induces selective decomposition on the graphene adjacent to the metal catalyst, thus forming nanoperforations. Furthermore, the pore size, pore density distribution, and neck size of the GNMs can be controlled by adjusting the size and fraction of the metal oxide on graphene. The fabricated GNM electrodes exhibit superior electrochemical properties for supercapacitor (ultracapacitor) applications, including exceptionally high capacitance (253 F g -1 at 1 A g -1 ) and high rate capability (212 F g -1 at 100 A g -1 ) with excellent cycle stability (91% of the initial capacitance after 50 000 charge/discharge cycles). Moreover, the edge-enriched structure of GNMs plays an important role in achieving edge-selected and high-level nitrogen doping.

25 ENERGY STORAGE↗

Momentum flow in black-hole binaries. II. Numerical simulations of equal-mass, head-on mergers with antiparallel spins

Research on extracting science from binary-black-hole (BBH) simulations has often adopted a 'scattering matrix' perspective: given the binary's initial parameters, what are the final hole's parameters and the emitted gravitational waveform? In contrast, we are using BBH simulations to explore the nonlinear dynamics of curved spacetime. Focusing on the head-on plunge, merger, and ringdown of a BBH with transverse, antiparallel spins, we explore numerically the momentum flow between the holes and the surrounding spacetime. We use the Landau-Lifshitz field-theory-in-flat-spacetime formulation of general relativity to define and compute the density of field energy and field momentum outside horizons and the energy and momentum contained within horizons, and we define the effective velocity of each apparent and event horizon as the ratio of its enclosed momentum to its enclosed mass-energy. We find surprisingly good agreement between the horizons' effective and coordinate velocities. During the plunge, the holes experience a frame-dragging-induced acceleration orthogonal to the plane of their spins and their infall ('downward'), and they reach downward speeds of order 1000 km/s. When the common apparent horizon forms (and when the event horizons merge and their merged neck expands), the horizon swallows upward field momentum that resided between the holes, causing the merged hole to accelerate in the opposite ('upward') direction. As the merged hole and the field energy and momentum settle down, a pulsational burst of gravitational waves is emitted, and the merged hole has a final effective velocity of about 20 km/s upward, which agrees with the recoil velocity obtained by measuring the linear momentum carried to infinity by the emitted gravitational radiation. To investigate the gauge dependence of our results, we compare generalized harmonic and Baumgarte-Shapiro-Shibata-Nakamura-moving-puncture evolutions of physically similar initial data; although the generalized harmonic and Baumgarte-Shapiro-Shibata-Nakamura-moving-puncture simulations use different gauge conditions, we find remarkably good agreement for our results in these two cases. We also compare our simulations with the post-Newtonian trajectories and near-field energy-momentum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clinical Outcomes of Patients Receiving Integrated PET/CT-Guided Radiotherapy for Head and Neck Carcinoma

Purpose: We previously reported the advantages of {sup 18}F-fluorodeoxyglucose-positron emission tomography (PET) fused with CT for radiotherapy planning over CT alone in head and neck carcinoma (HNC). The purpose of this study was to evaluate clinical outcomes and the predictive value of PET for patients receiving PET/CT-guided definitive radiotherapy with or without chemotherapy. Methods and Materials: From December 2002 to August 2006, 42 patients received PET/CT imaging as part of staging and radiotherapy planning. Clinical outcomes including locoregional recurrence, distant metastasis, death, and treatment-related toxicities were collected retrospectively and analyzed for disease-free and overall survival and cumulative incidence of recurrence. Results: Median follow-up from initiation of treatment was 32 months. Overall survival and disease-free survival were 82.8% and 71.0%, respectively, at 2 years, and 74.1% and 66.9% at 3 years. Of the 42 patients, seven recurrences were identified (three LR, one DM, three both LR and DM). Mean time to recurrence was 9.4 months. Cumulative risk of recurrence was 18.7%. The maximum standard uptake volume (SUV) of primary tumor, adenopathy, or both on PET did not correlate with recurrence, with mean values of 12.0 for treatment failures vs. 11.7 for all patients. Toxicities identified in those patients receiving intensity modulated radiation therapy were also evaluated. Conclusions: A high level of disease control combined with favorable toxicity profiles was achieved in a cohort of HNC patients receiving PET/CT fusion guided radiotherapy plus/minus chemotherapy. Maximum SUV of primary tumor and/or adenopathy was not predictive of risk of disease recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microscopic cold fission yields of {sup 252}Cf

We show that the sharp maximum corresponding to {sup 107}Mo in the fragment distribution of the {sup 252}Cf cold fission is actually a Sn-like radioactivity, similar to other decay processes in which magic nuclei are involved, namely alpha decay and heavy cluster emission, also called Pb-like radioactivity. It turns out that the mass asymmetry degree of freedom has a key role in connecting initial Sn with the final Mo isotopes along the fission path. We investigate the cold rearrangement of nucleons within the framework of the two-center shell model in order to compute the cold valleys in the charge equilibrated fragmentation potential. The fission yields are estimated by using the semiclassical penetration approach. We consider 5 degrees of freedom, namely the interfragment distance, the shapes of fragments, the neck parameter, and mass asymmetry. We found an isomeric minimum between the internal and external barriers. It turns out that the inner cold valley of the total potential energy is connected to the doubly magic isotope {sup 132}Sn.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dynamic Tensile Response of a Fe–49Co–2V Alloy at Various Strain Rates and Temperatures

Soft ferromagnetic alloys are often utilized in electromagnetic applications due to their desirable magnetic properties. In support of these applications, the ferromagnetic alloys are also required to bear mechanical load under various loading and environmental conditions. In this study, a Fe–49Co–2V alloy was dynamically characterized in tension with a Kolsky tension bar and a Drop–Hopkinson bar at various strain rates and temperatures. Dynamic tensile stress–strain curves of the Fe–49Co–2V alloy were obtained at strain rates ranging from 40 to 230 s -1 and temperatures from - 100 to 100 °C. All dynamic tensile stress–strain curves exhibited an initial linear elastic response to an upper yield followed by Lüders band response and then a nearly linear work-hardening behavior. The yield strength of this material was found to be sensitive to both strain rate and temperature, whereas the hardening rate was independent of strain rate or temperature. The Fe–49Co–2V alloy exhibited a feature of brittle fracture in tension under dynamic loading with no necking being observed.

36 MATERIALS SCIENCE↗

Dynamic Tensile Characterization of Hiperco 50A Alloy at Various Strain Rates and Temperatures

Soft ferromagnetic alloys are often utilized in electromagnetic applications due to their desirable magnetic properties. In support of these applications, the ferromagnetic alloys are also desired to bear mechanical load at various environmental temperatures. In this study, a Permendur 2V alloy manufactured by Metalwerks Inc. (but referred to Hiperco 50A, a trademark of Carpenter Technologies Inc.) was dynamically characterized in tension with a Kolsky tension bar and a Dropkinson bar at various strain rates and temperatures. Dynamic tensile stress-strain curves of the Hiperco 50A alloy were obtained at the strain rates ranging from 40 to 230 s -1 and temperatures from -100 to 100°C. All tensile stress-strain curves exhibited an initial linear elastic response to an upper yield followed by a Eiders banding response and then a nearly linear work-hardening behavior. The yield strength of this material was found to be sensitive to both strain rate and temperature; whereas, the hardening rate was independent of strain rate or temperature. The Hiperco 50A alloy exhibited a feature of brittle fracture in tension under dynamic loading with no necking being observed.

36 MATERIALS SCIENCE↗

On the evolution of the plume function and entrainment in the near-source region of lazy plumes

Plumes occur in many natural and industrial settings, such as chimney smoke, volcanic eruptions and deep water oil spills. A plume function, $\unicode[STIX]{x1D6E4}$ , is used to characterize plumes and jets. The far-field behaviour of these flows has been studied in great detail while the near-field behaviour has not quite received the same attention. We examine near-field phenomena such as radial constriction, termed necking, and vortex structure formations with new high resolution direct numerical simulations. Four lazy plumes with increasing values of the source plume parameter, $\unicode[STIX]{x1D6E4}_{0}$ , are simulated. We study the evolution of entrainment and the plume function. The original assumptions, that Reynolds stresses dominate viscous shear stresses, do not hold for lazy plumes in the near field. Due to this, a deviation from self-similarity occurs initially and is corrected by a large entrainment coefficient caused by vortex stretching and compression. After correcting for the virtual origin, comparison between theory and simulations shows a monotonic decay of $\unicode[STIX]{x1D6E4}$ towards pure plume behaviour. The entrainment coefficient asymptotes to a widely accepted constant value for plumes.

Mechanics↗

Oxygen and Perfusion Kinetics in Response to Fractionated Radiation Therapy in FaDu Head and Neck Cancer Xenografts Are Related to Treatment Outcome

Purpose: To test whether oxygenation kinetics correlate with the likelihood for local tumor control after fractionated radiation therapy. Methods and Materials: We used diffuse reflectance spectroscopy to noninvasively measure tumor vascular oxygenation and total hemoglobin concentration associated with radiation therapy of 5 daily fractions (7.5, 9, or 13.5 Gy/d) in FaDu xenografts. Spectroscopy measurements were obtained immediately before each daily radiation fraction and during the week after radiation therapy. Oxygen saturation and total hemoglobin concentration were computed using an inverse Monte Carlo model. Results: First, oxygenation kinetics during and after radiation therapy, but before tumor volumes changed, were associated with local tumor control. Locally controlled tumors exhibited significantly faster increases in oxygenation after radiation therapy (days 12-15) compared with tumors that recurred locally. Second, within the group of tumors that recurred, faster increases in oxygenation during radiation therapy (day 3-5 interval) were correlated with earlier recurrence times. An area of 0.74 under the receiver operating characteristic curve was achieved when classifying the local control tumors from all irradiated tumors using the oxygen kinetics with a logistic regression model. Third, the rate of increase in oxygenation was radiation dose dependent. Radiation doses ≤9.5 Gy/d did not initiate an increase in oxygenation, whereas 13.5 Gy/d triggered significant increases in oxygenation during and after radiation therapy. Conclusions: Additional confirmation is required in other tumor models, but these results suggest that monitoring tumor oxygenation kinetics could aid in the prediction of local tumor control after radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 29: Characterization of Patient Immobilization for Head and Neck Cancer Treatment

Purpose: Evaluate an immobilization system to determine its adequacy for the reduced margins required for proton therapy. Methods: Twelve head-and-neck cancer patients were immobilized for conventional photon radiotherapy and imaged with pre- and post-treatment cone beam CTs (CBCTs) for each treatment fraction. To quantify the patient positioning reproducibility, each CBCT was registered to the simulation CT offline. Registrations were performed using auto-match tools and a matching volume-of-interest (VOI) consisting of a 5mm expansion around the mandible, occipital bone, C1/C2 and C7/T1. For each registration, the bony anatomy in the VOI was evaluated for agreement with the simulation position using 3 and 5mm margins. Registrations were initially restricted to translational corrections. If the bony anatomy did not agree with the simulation position to within 3mm or 5mm, the auto-match was repeated with 3 additional rotational corrections. Intrafraction motion was calculated as the difference between the pre- and post-treatment CBCT matches. Results: Pre-treatment patient positioning agreed with the simulation CT to within 3mm/5mm for 62%/86% of fractions using translational matching and 84%/100% of fractions when rotations were included. Intrafraction motion averaged 1.1±0.8mm, with 12% of fractions having >2mm intrafraction motion. Post-treatment positioning accuracy was 57%/84% and 80%/100% for registrations without/with rotations. For the mandible, positioning accuracy dropped from 93% pre-treatment to 82% post-treatment. Conclusion: If rotational corrections are available, the immobilization system studied created reproducible patient positioning to within 3mm for 84% of fractions. However, intrafraction motion caused additional anatomy to fall outside the 3mm margin by the end of treatment.

60 APPLIED LIFE SCIENCES↗

Phase I Trial Using the Proteasome Inhibitor Bortezomib and Concurrent Chemoradiotherapy for Head-and-Neck Malignancies

Purpose: Advanced head-and-neck cancer (HNC) remains a difficult disease to cure. Proteasome inhibitors such as bortezomib have the potential to improve survival over chemoradiotherapy alone. This Phase I dose-escalation study examined the potential of bortezomib in combination with cisplatin chemotherapy and concurrent radiation in the treatment of locally advanced and recurrent HNC. Methods and Materials: Eligible patients received cisplatin once weekly at 30 mg/m{sup 2} per week and bortezomib along with concurrent radiation. Bortezomib was given on Days 1, 4, 8, and 11 every 3 weeks, with an initial starting dose of 0.7 mg/m{sup 2} and escalation levels of 1.0 and 1.3 mg/m{sup 2}. Dose escalation was performed only after assessment to rule out any dose-limiting toxicity. Results: We enrolled 27 patients with HNC, including 17 patients with recurrent disease who had received prior irradiation. Patients received bortezomib dose levels of 0.7 mg/m{sup 2} (7 patients), 1.0 mg/m{sup 2} (10 patients), and 1.3 mg/m{sup 2} (10 patients). No Grade 5 toxicities, 3 Grade 4 toxicities (all hematologic and considered dose-limiting toxicities), and 39 Grade 3 toxicities (in 20 patients) were observed. With a median follow-up of 7.4 months, the overall median survival was 24.7 months (48.4 months for advanced HNC patients and 15.4 months for recurrent HNC patients). Conclusion: Bortezomib in combination with radiation therapy and cisplatin chemotherapy is safe in the treatment of HNC with a bortezomib maximum tolerated dose of 1.0 mg/m{sup 2} in patients previously treated for HNC and 1.3 mg/m{sup 2} in radiation-naive patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation dose to the tumor while minimizing the amount of radiation delivered to healthy tissue. Registration of planning images with daily images is thus an important component of ART. In this article, the authors report their research on multiscale registration of planning computed tomography (CT) images with daily cone beam CT (CBCT) images. The multiscale algorithm is based on the hierarchical multiscale image decomposition of E. Tadmor, S. Nezzar, and L. Vese [Multiscale Model. Simul. 2(4), pp. 554-579 (2004)]. Registration is achieved by decomposing the images to be registered into a series of scales using the (BV, L{sup 2}) decomposition and initially registering the coarsest scales of the image using a landmark-based registration algorithm. The resulting transformation is then used as a starting point to deformably register the next coarse scales with one another. This procedure is iterated at each stage using the transformation computed by the previous scale registration as the starting point for the current registration. The authors present the results of studies of rectum, head-neck, and prostate CT-CBCT registration, and validate their registration method quantitatively using synthetic results in which the exact transformations our known, and qualitatively using clinical deformations in which the exact results are not known.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Segmentation and Online virtualCT in Head-and-Neck Adaptive Radiation Therapy

Purpose: The purpose of this work was to develop and validate an efficient and automatic strategy to generate online virtual computed tomography (CT) scans for adaptive radiation therapy (ART) in head-and-neck (HN) cancer treatment. Method: We retrospectively analyzed 20 patients, treated with intensity modulated radiation therapy (IMRT), for an HN malignancy. Different anatomical structures were considered: mandible, parotid glands, and nodal gross tumor volume (nGTV). We generated 28 virtualCT scans by means of nonrigid registration of simulation computed tomography (CTsim) and cone beam CT images (CBCTs), acquired for patient setup. We validated our approach by considering the real replanning CT (CTrepl) as ground truth. We computed the Dice coefficient (DSC), center of mass (COM) distance, and root mean square error (RMSE) between correspondent points located on the automatically segmented structures on CBCT and virtualCT. Results: Residual deformation between CTrepl and CBCT was below one voxel. Median DSC was around 0.8 for mandible and parotid glands, but only 0.55 for nGTV, because of the fairly homogeneous surrounding soft tissues and of its small volume. Median COM distance and RMSE were comparable with image resolution. No significant correlation between RMSE and initial or final deformation was found. Conclusion: The analysis provides evidence that deformable image registration may contribute significantly in reducing the need of full CT-based replanning in HN radiation therapy by supporting swift and objective decision-making in clinical practice. Further work is needed to strengthen algorithm potential in nGTV localization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-C-17A-03: A GPU-Based Method for Validating Deformable Image Registration in Head and Neck Radiotherapy Using Biomechanical Modeling

Purpose: Deformable image registration (DIR) plays a pivotal role in head and neck adaptive radiotherapy but a systematic validation of DIR algorithms has been limited by a lack of quantitative high-resolution groundtruth. We address this limitation by developing a GPU-based framework that provides a systematic DIR validation by generating (a) model-guided synthetic CTs representing posture and physiological changes, and (b) model-guided landmark-based validation. Method: The GPU-based framework was developed to generate massive mass-spring biomechanical models from patient simulation CTs and contoured structures. The biomechanical model represented soft tissue deformations for known rigid skeletal motion. Posture changes were simulated by articulating skeletal anatomy, which subsequently applied elastic corrective forces upon the soft tissue. Physiological changes such as tumor regression and weight loss were simulated in a biomechanically precise manner. Synthetic CT data was then generated from the deformed anatomy. The initial and final positions for one hundred randomly-chosen mass elements inside each of the internal contoured structures were recorded as ground truth data. The process was automated to create 45 synthetic CT datasets for a given patient CT. For instance, the head rotation was varied between +/− 4 degrees along each axis, and tumor volumes were systematically reduced up to 30%. Finally, the original CT and deformed synthetic CT were registered using an optical flow based DIR. Results: Each synthetic data creation took approximately 28 seconds of computation time. The number of landmarks per data set varied between two and three thousand. The validation method is able to perform sub-voxel analysis of the DIR, and report the results by structure, giving a much more in depth investigation of the error. Conclusions: We presented a GPU based high-resolution biomechanical head and neck model to validate DIR algorithms by generating CT equivalent 3D volumes with simulated posture changes and physiological regression.

60 APPLIED LIFE SCIENCES↗

Forecasting longitudinal changes in oropharyngeal tumor morphology throughout the course of head and neck radiation therapy

Purpose: To create models that forecast longitudinal trends in changing tumor morphology and to evaluate and compare their predictive potential throughout the course of radiation therapy. Methods: Two morphology feature vectors were used to describe 35 gross tumor volumes (GTVs) throughout the course of intensity-modulated radiation therapy for oropharyngeal tumors. The feature vectors comprised the coordinates of the GTV centroids and a description of GTV shape using either interlandmark distances or a spherical harmonic decomposition of these distances. The change in the morphology feature vector observed at 33 time points throughout the course of treatment was described using static, linear, and mean models. Models were adjusted at 0, 1, 2, 3, or 5 different time points (adjustment points) to improve prediction accuracy. The potential of these models to forecast GTV morphology was evaluated using leave-one-out cross-validation, and the accuracy of the models was compared using Wilcoxon signed-rank tests. Results: Adding a single adjustment point to the static model without any adjustment points decreased the median error in forecasting the position of GTV surface landmarks by the largest amount (1.2 mm). Additional adjustment points further decreased the forecast error by about 0.4 mm each. Selection of the linear model decreased the forecast error for both the distance-based and spherical harmonic morphology descriptors (0.2 mm), while the mean model decreased the forecast error for the distance-based descriptor only (0.2 mm). The magnitude and statistical significance of these improvements decreased with each additional adjustment point, and the effect from model selection was not as large as that from adding the initial points. Conclusions: The authors present models that anticipate longitudinal changes in tumor morphology using various models and model adjustment schemes. The accuracy of these models depended on their form, and the utility of these models includes the characterization of patient-specific response with implications for treatment management and research study design.

60 APPLIED LIFE SCIENCES↗

Electroelastic investigation of drying rate in the direct contact ultrasonic fabric dewatering process

Ultrasonic vibrations, used to atomize liquids into a fine mist, are a promising solution for the future of efficient clothes drying technology. The world’s first ultrasonic dryer—demonstrated by researchers at Oak Ridge National Laboratory—successfully applies the scientific principles behind ultrasonic drying, and several working prototypes have been demonstrated. This technology is based on direct mechanical coupling between mesh piezoelectric transducers and wet fabric. During the atomization process, vertical oscillations of a contained liquid, called Faraday excitations, result in the formation of standing waves on the liquid surface. At increasing amplitudes and frequencies of oscillation, wave peaks become extended and form “necks” connecting small secondary droplets to the bulk liquid. When the oscillation reaches an acceleration threshold, the droplet momentum is sufficient to break the surface tension of the neck and enable the droplets to travel away from the liquid. In this work, we investigate the atomization process using an ultrasonic transducer as it pertains to moisture retained within a fabric. An experimentally validated electromechanical analytical-numerical model is proposed. This model bridges the vibrations of a piezoelectric mesh transducer to the critical acceleration needed for fabric drying to occur. Then, the drying rate model is developed, consisting of an initial nonlinear region due to atomization, followed by a linear thermal evaporation region. The models developed identify the influence of key parameters on ultrasonic drying and will aid in improving atomizer design for efficient, timely fabric drying. This study is the first proposed model for the ultrasonic atomization of fabrics saturated with water, applicable to any type of transducer. The results present a non-dimensional equation for the ultrasonic dewatering of fabrics, dependent only on transducer acceleration and the surface area of the cloth. Furthermore, the development of this technology using the proposed physical models will allow for global reductions in electrical demand related to clothes drying.

42 ENGINEERING↗

Dosimetric verification of surface and superficial doses for head and neck IMRT with different PTV shrinkage margins

Purpose: Dosimetric uncertainty in the surface and superficial regions is still a major concern for radiation therapy and becomes more important when using the inverse planning algorithm for IMRT. The purpose of this study was to measure dose distributions and to evaluate the calculation accuracy in the superficial region for different planning target volume (PTV) shrinkage methods for head and neck IMRT plans. Methods: A spherical polystyrene phantom 160 mm in diameter (ball phantom) was used to simulate the shape of the head. Strips of superflab bolus with thicknesses of 3.5 and 7.0 mm were spread on the surface of the ball phantom. Three sets of CT images were acquired for the ball phantom without and with the bolus. The hypothetical clinical target volume (CTV) and critical structures (spinal cord and parotid glands) were outlined on each set of CT images. The PTVs were initially created by expanding an isotropic 3 mm margin from the CTV and then margins of 0, 3, and 5 mm were shrunk from the phantom surface for dosimetric analysis. Seven-field IMRT plans with a prescribed dose of 180 cGy and same dose constraints were designed using an Eclipse treatment planning system. Superficial doses at depths of 0, 3.5, and 7.0 mm and at seven beam axis positions (gantry angles of 0 deg., 30 deg., 60 deg., 80 deg., 330 deg., 300 deg., and 280 deg.) were measured for each PTV shrinkage margin using 0.1 mm ultrathin thermoluminescent dosimeters. For each plan, the measured doses were compared to the calculated doses. Results: The PTV without shrinkage had the highest intensity and the steepest dose gradient in the superficial region. The mean measured doses for different positions at depths of 0, 3.5, and 7.0 mm were 106{+-}18, 185{+-}16, and 188{+-}12 cGy, respectively. For a PTV with 3 mm shrinkage, the mean measured doses were 94{+-}13, 183{+-}8, and 191{+-}8 cGy. For a PTV with 5 mm shrinkage, the mean measured doses were 86{+-}11, 173{+-}8, and 187{+-}5 cGy. The comparisons indicated that more than 73.3% of the calculated points are with doses lower than the measured points and the difference of the dose becomes more significant in the shallower region. At 7.0 mm depth, the average difference between calculations and measurements was 2.5% (maximum 5.5%). Conclusions: Application of the PTV shrinkage method should take into account the calculation inaccuracy, tumor coverage, and possible skin reaction. When the tumor does not invade the superficial region, an adequate shrinkage margin from the surface is helpful for reducing the skin reaction. As the tumor invades the superficial region, adding a bolus is a method better than only contouring PTV with skin inclusion.

60 APPLIED LIFE SCIENCES↗

SU-E-T-261: Development of An Automated System to Detect Patient Identification and Positioning Errors Prior to Radiotherapy Treatment

Purpose: To develop a system that can automatically detect patient identification and positioning errors using 3D computed tomography (CT) setup images and kilovoltage CT (kVCT) planning images. Methods: Planning kVCT images were collected for head-and-neck (H&N), pelvis, and spine treatments with corresponding 3D cone-beam CT (CBCT) and megavoltage CT (MVCT) setup images from TrueBeam and TomoTherapy units, respectively. Patient identification errors were simulated by registering setup and planning images from different patients. Positioning errors were simulated by misaligning the setup image by 1cm to 5cm in the six anatomical directions for H&N and pelvis patients. Misalignments for spine treatments were simulated by registering the setup image to adjacent vertebral bodies on the planning kVCT. A body contour of the setup image was used as an initial mask for image comparison. Images were pre-processed by image filtering and air voxel thresholding, and image pairs were assessed using commonly-used image similarity metrics as well as custom -designed metrics. A linear discriminant analysis classifier was trained and tested on the datasets, and misclassification error (MCE), sensitivity, and specificity estimates were generated using 10-fold cross validation. Results: Our workflow produced MCE estimates of 0.7%, 1.7%, and 0% for H&N, pelvis, and spine TomoTherapy images, respectively. Sensitivities and specificities ranged from 98.0% to 100%. MCEs of 3.5%, 2.3%, and 2.1% were obtained for TrueBeam images of the above sites, respectively, with sensitivity and specificity estimates between 96.2% and 98.4%. MCEs for 1cm H&N/pelvis misalignments were 1.3/5.1% and 9.1/8.6% for TomoTherapy and TrueBeam images, respectively. 2cm MCE estimates were 0.4%/1.6% and 3.1/3.2%, respectively. Vertebral misalignment MCEs were 4.8% and 4.9% for TomoTherapy and TrueBeam images, respectively. Conclusion: Patient identification and gross misalignment errors can be robustly and automatically detected using 3D setup images of two imaging modalities across three commonly-treated anatomical sites.

60 APPLIED LIFE SCIENCES↗

Finite deformation of elasto-plastic solids

A theoretical basis is established for analysis of finite deformation of metals. The observation that finite deformation of such elastoplastic materials may be viewed as a process rather than an event leads to derivation of a complete initial and boundary value problem distinguished by its quasilinear nature. This feature of the formulation motivates adoption of an incremental approach to numerical problem solving. Numerical solution capability is established for problems of plane stress and plane strain. The validity of the theory and numerical analysis is demonstrated by consideration of a number of problems of homogeneous finite deformation for which analytic solutions are available. Subsequently the analysis is employed for the investigation of necking in flat metal tensile bars. The results of this investigation provide the first full numerical solutions for tensile necking in plane stress and plane strain. In addition a basis is provided for assessment of the validity of stress-strain relations inferred from tensile test data.

Osias, J. R.↗