Search NASA⌕ Search

SEARCH · Search NASA

Results for “Net load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Renewable Generation Effect on Net Regional Energy Interchange: Preprint

Using production-cost model (PLEXOS), we simulate the Western Interchange (WECC) at several levels of the yearly renewable energy (RE) generation, between 13% and 40% of the total load for the year. We look at the overall energy exchange between a region and the rest of the system (net interchange, NI), and find it useful to examine separately (i) (time-)variable and (ii) year-average components of the NI. Both contribute to inter-regional energy exchange, and are affected by wind and PV generation in the system. We find that net load variability (in relatively large portions of WECC) is the leading factor affecting the variable component of inter-regional energy exchange, and the effect is quantifiable: higher regional net load correlation with the rest of the WECC lowers net interchange variability. Further, as the power mix significantly varies between WECC regions, effects of ‘flexibility import’ (regions ‘borrow’ ramping capability) are also observed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Load Profile Inpainting for Missing Load Data Restoration and Baseline Estimation

This paper introduces a Generative Adversarial Nets (GAN) based, Load Profile Inpainting Network (Load-PIN) for restoring missing load data segments and estimating the baseline for a demand response event. The inputs are time series load data before and after the inpainting period together with explanatory variables (e.g., weather data). Here, we propose a Generator structure consisting of a coarse network and a fine-tuning network. The coarse network provides an initial estimation of the data segment in the inpainting period. The fine-tuning network consists of self-attention blocks and gated convolution layers for adjusting the initial estimations. Loss functions are specially designed for the fine-tuning and the discriminator networks to enhance both the point-to-point accuracy and realisticness of the results. We test the Load-PIN on three real-world data sets for two applications: patching missing data and deriving baselines of conservation voltage reduction (CVR) events. We benchmark the performance of Load-PIN with five existing deep-learning methods. Our simulation results show that, compared with the state-of-the-art methods, Load-PIN can handle varying-length missing data events and achieve 15-30% accuracy improvement.

14 SOLAR ENERGY↗

Space Shuttle Atmospheric ascent flight dynamics

The atmospheric ascent flight phase of the mated composite booster and orbiter is discussed. The composite recoverable space shuttle booster and orbiter exhibits unique flight control characteristics. This uniqueness results from large lifting surfaces and aerodynamic and structural assymetrics. An effective load relief technique reduces aerodynamic loads on both the booster and the orbiter. Reducing aerodynamic loads permits decreasing the structural weight of the lifting and stabilizing surfaces. An orbiter payload penalty is caused by trajectory deviations resulting from load relief. However, the net effect of an effective load relief technique is an increase in payload capability. Atmospheric launch dynamics investigations have been carried out for different configuration types, which include expendable, straight wing, delta wing, and ballistic recoverable boosters.

Patha, J. T.↗

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

In constructing a new research facility for its campus, the National Renewable Energy Laboratory (NREL) project team identified the opportunity to design a world-class, energy-efficient data center to support its operations. NREL’s efforts resulted in a highly efficient data center that demonstrated considerable energy savings in its first 11 months of operations. Using legacy data center performance as a baseline, the new facility cut energy use by nearly 1,450,000 kWh, delivering cost savings of approximately $82,000. The data center’s average total load was 165 kW less than the legacy center’s average total load, resulting in a 60% reduction in overall power. Finally, the limited use of cooling and fan energy enabled the new data center to achieve a 1.16 average power utilization effectiveness (PUE) rating, compared to the legacy data center’s PUE of 2.28.

Reducing, Data, Large-Scale, Net-Zero, Office, Bui↗

IM3 + EPRI Data Center Load Projections

This dataset contains scenarios of hourly total electricity demand with and without projected loads from data centers over the period 2022-2040. The root projections without data center demands are identical to those documented in Burleyson et al. 2024. In short, those projections encompass hourly electricity demands for 54 Balancing Authorities (BAs) in the United States across a range of eight of weather and socioeconomic scenarios. Refer to the root dataset and accompanying publication, Burleyson et al. 2025, for information about how those projections were generated. For this derivative dataset we used the base loads from the following scenarios: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The root load projections did not reflect the drastic expansion of data centers that has occurred in the last several years to support artificial intelligence and cloud computing. To reflect growth in data center demand, a second set of load projections were created in which we layered in additional data center load projections based on the data center load growth scenarios described in a 2024 report by the Electric Power Research Institute (EPRI): "Powering Intelligence: Analyzing Artificial Intelligence and Data Center Energy Consumption". The EPRI projections from the report are included in this dataset (EPRI_2024_Projections.xlsx). That report contained annual state-level data center load projections for four year-over-year growth rates for data center demands: Low (3.71% annual growth) Moderate (5% annual growth) High (10% annual growth) Higher (15% annual growth) To homogenize the load projections with and without data centers we had to get them to a common scale. The first step was to take the EPRI annual state-level data center energy consumption values and convert them to 8760-hr loads for each year. We did that by assuming a flat (e.g., not weather- or time-sensitive) load profile and distributing the data center loads in each state evenly across all hours in a year. From there the loads were downscaled from the state-level to the county-level using 2019 county-level populations as weights. Finally, the county-level hourly data center loads were summed to the BA-level using the county-to-BA mapping underpinning the root load projections. The net result is 16 (4 weather and socioeconomic scenarios crossed with 4 data center load growth scenarios) unique load projections for the period 2022-2040. The file format follows that of the root dataset with a single additional column "Scaled_TELL_BA_Load_with_DC_MWh" that contains the hourly loads with the added data center loads for a given BA-year-scenario combination. Please refer to the readme file in the root dataset for more information on the file format.

Burleyson, Casey [Pacific Northwest National Labor↗

A laboratory facility for electric vehicle propulsion system testing

The road load simulator facility located at the NASA Lewis Research Center enables a propulsion system or any of its components to be evaluated under a realistic vehicle inertia and road loads. The load is applied to the system under test according to the road load equation: F(net)=K1F1+K2F2V+K3 sq V+K4(dv/dt)+K5 sin theta. The coefficient of each term in the equation can be varied over a wide range with vehicle inertial representative of vehicles up to 7500 pounds simulated by means of flywheels. The required torque is applied by the flywheels, a hydroviscous absorber and clutch, and a drive motor integrated by a closed loop control system to produce a smooth, continuous load up to 150 horsepower.

Sargent, N. B.↗

Iogenic Plasma and its Rotation-Driven Transport in Jupiter's Magnetosphere

Model calculations are reported for the Iogenic plasma source created by atomic oxygen and sulfur above Io's exobase in the corona and extended clouds (Outer Region). On a circumplanetary scale, two-dimensional distributions produced by integrating the proper three dimensional rate information for electron impact and charge exchange processes along the magnetic field lines are presented for the pickup ion rates, the net-mass and total-mass loading rates, the mass per unit magnetic flux rate, the pickup conductivity, the radial pickup current, and the net-energy loading rate for the plasma torus. All of the two-dimensional distributions are highly peaked at Io's location and hence highly asymmetric about Jupiter. The Iogenic plasma source is also calculated on a much smaller near-Io scale to investigate the structure of the highly peak rates centered about lo's instantaneous location. The Iogenic plasma source for the Inner Region (pickup rates produced below Io's exobase) is, however, expected to be the dominant source near lo for the formation of the plasma torus ribbon and to be a comparable source, if not a larger contributor, to the energy budget of the plasma torus, so as to provide the necessary power to sustain the plasma torus radiative loss rate.

Smyth, William H.↗

Wave Prediction using X-Band Radar (Final Summary Report)

Model Predictive Control (MPC) is the best controls framework available to wave energy today. It allows for the maximization of energy yield from a WEC system while respecting various constraints and losses in the system. This type of constrained optimization is a critical capability for the techno-economic optimization of WEC devices and is difficult to do effectively with causal controls frameworks. MPC requires a future prediction of wave excitation forces, requiring wave prediction on a future time horizon of up to 30 seconds. The future horizon required is highly dependent on the WEC and PTO type available. To our knowledge no-one has been able to implement MPC on a WEC device at sea, due to the fact that phase-resolved wave-prediction is not a capability that has been sufficiently developed to date. The key objectives of this project are focused on developing “industry-ready” wave prediction technology building blocks that can be applied to a wide range of different wave energy conversion topologies. Our collaborative work with device developers has demonstrated that the level of improvement attainable for any particular device is heavily dependent on the device and PTO topology chosen. The range of annual average power capture improvements is on the order of 10% to over 100%. However, the important aspect is that we can get within about 10% of theoretical upper limits even when considering errors in the wave prediction and more importantly, we can optimize performance while respecting various constraints such as motion amplitude or peak structural loads. The combination of improved performance while limiting structural loads has a net effect of reducing the levelized cost of energy from these emerging technologies and allows us to design control laws that meet an economic optimum. Efforts under a previous project on controls has focused on developing a set of wave-prediction algorithms that work by leveraging a network of wave sensing measurement buoys that are equipped with real-time telemetry. The present work is focusing primarily on using X-band radar to measure the wave-field around the WEC to predict the future excitation forces on the structure and combining the measurements of these different sources to create improvements in the wave-prediction accuracy.

16 TIDAL AND WAVE POWER↗

Systems Performance Analyses of Alaska Wind-Diesel Projects; Kasigluk, Alaska (Fact Sheet)

This fact sheet summarizes a systems performance analysis of the wind-diesel project in Kasigluk, Alaska. Data provided for this project include community load data, average wind turbine output, average diesel plant output, thermal load data, average net capacity factor, average net wind penetration, estimated fuel savings, and wind system availability.

17 WIND ENERGY↗

Systems Performance Analyses of Alaska Wind-Diesel Projects; Toksook Bay, Alaska (Fact Sheet)

This fact sheet summarizes a systems performance analysis of the wind-diesel project in Toksook Bay, Alaska. Data provided for this project include community load data, average wind turbine output, average diesel plant output, thermal load data, average net capacity factor, optimal net capacity factor based on Alaska Energy Authority wind data, average net wind penetration, estimated fuel savings, and wind system availability.

17 WIND ENERGY↗

Development of biaxial test fixture includes cryogenic application

Test fixture has the capability of producing biaxial stress fields in test specimens to the point of failure. It determines biaxial stress by dividing the applied load by the net cross section. With modification it can evaluate materials, design concepts, and production hardware at cryogenic temperatures.

Helf, J. C.↗

Characteristics of pressure waves

Air blast characteristics generated by most types of explosions are discussed. Data cover both negative and positive blast load phases and net transverse pressure as a function of time. The effects of partial or total confinement, atmospheric propagation, absorption of energy by ground shock or cratering, and transmission over irregular terrain on blast wave properties were also considered.

Source record↗

Analysis of aerothermal loads on spherical dome protuberances

Hypersonic flow over spherical dome protuberances was investigated to determine increased pressure and heating loads to the surface. The configuration was mathematically modeled in a time-dependant three-dimensional analysis of the conservation of mass, momentum (Navier-Stokes), and energy equations. A boundary mapping techique was used to obtain a rectangular parallelepiped computational domain, and a MacCormack explicit time-split predictor-corrector finite difference algorithm was used to obtain solutions. Results show local pressures and heating rates for domes one-half, one, and two boundary layer thicknesses high were increased by factors on the order of 1.4, 2, and 6, respectively. However, because lee-side pressure and thermal loads were reduced the two lower height domes did not experience any net increase in total loads. The total loads on the higher dome were increased by twenty-five percent. Flow over the lower dome was everywhere attached while flow over the intermediate dome had small windward and leeside separations. The higher dome had an unsteady windward separation region and a large leeside separation region. Trailing vortices form on all domes with intensity increasing with dome height. Discussions of applying the results to a thermally bowed thermal protection system are presented.

Olsen, G. C.↗

Electric Vehicle Managed Charging: Estimating the Potential Bulk Power System Value

With more and more electric vehicles (EVs) on the road, the grid of the future can greatly benefit from EV managed charging, which coordinates charging based on people's travel needs, electricity supply, and grid conditions. The added flexibility could be especially valuable for the bulk power system as it transitions to high shares of variable renewable generation, like wind and solar. Numerous studies have estimated the potential value of EV managed charging. In this study, NREL leveraged more detailed modeling of EV adoption, use, charging, and bulk power system operations to understand the potential value. Unique to this study, NREL modeled different charging flexibility types and dispatch mechanisms - as well as participation rates among drivers in having their EV charging managed - starting from vehicle-specific descriptions of charging flexibility. The study is based on a passenger light-duty vehicle adoption scenario with 100% EV sales by 2035 and a New England power system in 2038 with 84% clean generation and 26% of the electric load met by net imports. The 2038 New England light-duty vehicle feet is modeled as 45% electric.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Entrainment Makes Pollution More Likely to Weaken Deep Convective Updrafts Than Invigorate Them

Are the results of aerosol invigoration studies that neglect entrainment valid for diluted deep convective clouds? We address this question by applying an entraining parcel model to soundings from tropical and midlatitude convective environments, wherein pollution is assumed to increase parcel condensate retention. Invigoration of 5%–10% and <2% is possible in undiluted tropical and midlatitude parcels respectively when freezing is rapid. This occurs because the positive buoyancy contribution from freezing is larger than the negative buoyancy contribution from condensate loading, leading to positive net condensate contribution to buoyancy. However, aerosol-induced weakening is more likely when realistic entrainment rates occur because water losses from entrainment more substantially reduce the latent heating relative to the loading contribution. This leads to larger net negative buoyancy contribution from condensates in polluted than in clean entraining parcels. Our results demonstrate that accounting for entrainment is critical in conceptual models of aerosol indirect effects in deep convection.

54 ENVIRONMENTAL SCIENCES↗

Torque Limits for Fasteners in Composites

The two major classes of laminate joints are bonded and bolted. Often the two classes are combined as bonded-bolted joints. Several characteristics of fiber reinforced composite materials render them more susceptible to joint problems than conventional metals. These characteristics include weakness in in-plane shear, transverse tension/compression, interlaminar shear, and bearing strength relative to the strength and stiffness in the fiber direction. Studies on bolted joints of composite materials have been focused on joining assembly subject to in-plane loads. Modes of failure under these loading conditions are net-tension failure, cleavage tension failure, shear-out failure, bearing failure, etc. Although the studies of torque load can be found in literature, they mainly discussed the effect of the torque load on in-plane strength. Existing methods for calculating torque limit for a mechanical fastener do not consider connecting members. The concern that a composite member could be crushed by a preload inspired the initiation of this study. The purpose is to develop a fundamental knowledge base on how to determine a torque limit when a composite member is taken into account. Two simplified analytical models were used: a stress failure analysis model based on maximum stress criterion, and a strain failure analysis model based on maximum strain criterion.

Yi Zhao↗