Search NASA⌕ Search

SEARCH · Search NASA

Results for “Net load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Effectiveness of Residue and Tillage Management on Runoff Pollutant Reduction from Agricultural Areas

Highlights No-till and no-till residue systems were effective in reducing runoff particulate and total nutrients but increased dissolved nutrients. Maintaining >30% residue cover reduced most runoff constituents, irrespective of no-till or tillage. No-till-residue prevented runoff nutrient losses and benefitted farm revenue by avoiding tillage. Abstract. Reduced tillage management conservation practices (No-till and Reduced-till) are widely adopted in agriculture; however, understanding their overall effectiveness for water quality protection is challenging. A meta-analysis was conducted to understand and quantify the effectiveness of residue and tillage management on runoff, sediment, and nutrient losses from agricultural fields. Annual runoff and the associated sediment, and nutrient (nitrogen and phosphorus) loads were compiled from 60 peer reviewed research articles published across the United States and Canada. A total of 1575 site-years of data were categorized into tillage (<30% surface cover), no-tillage (<30% surface cover), tillage with residue (>30% surface cover), no-tillage with residue (>30% surface cover), and pasture management. No-tillage, no-tillage-residue, and tillage-residue managements were evaluated for their effectiveness in reducing runoff, nutrients, and sediment loads compared to tillage. Synthesized and surveyed corn yield data were used to evaluate the economic cost effectiveness of no-tillage-residue management with respect to tillage. Across the site years (1968-2019) studied, median runoff depth for no-tillage and no-tillage-residue were 84% and 70% greater than tillage and tillage-residue management, respectively. No-tillage-residue management had up to 86% less sediment losses than tillage systems, on average, for both >30% and <30% surface cover. No-tillage-residue management was most effective, with a positive performance effectiveness of 65% to 90% in controlling sediments, particulate, and total nutrient losses in runoff compared to tillage. Cost effectiveness analysis revealed the benefits of no-tillage-residue management in reducing nutrient loads and increasing net-farm revenue by avoiding tillage operational costs. Except for dissolved phosphorus, no-tillage-residue management cost effectiveness for sediments and nutrient loads ranged from negative $6 to negative $102 per every Mg or kg of load reduction, indicating it had both economic and environmental benefits compared to tillage management. Overall, these results indicate that over the long-term, no-tillage and tillage, combined with greater than 30% residue cover, can effectively reduce sediment and nutrient losses. This work highlights the importance of crop residues on the soil surface to reduce runoff losses, even in no-tillage systems. Keywords: Conservation tillage, No-tillage, Residue cover, Tillage, Water quality.

Agriculture↗

IDAES Enterprise: Generation Expansion Planning with Enhanced Requirements for Capacity Adequacy Under Renewable Intermittency

Achieving net zero carbon emissions likely requires future power systems to integrate new, flexible energy technologies to accommodate higher levels of capacity from variable renewable energy sources. To determine the optimal deployment of new electricity capacity and to study the likelihood of deployments of new energy technologies, an expansion planning model has been developed as part of the IDAES-Enterprise suite of grid models. The Generation Expansion Planning (GEP) model is a multi-period model in which investment decisions occur yearly, and a Unit Commitment (UC) problem is examined on an hourly timescale. To reduce computational complexity of the GEP model, the UC problem is solved for average “representative days” which leaves out extreme, but relatively common, scenarios in which low renewable generation occurs, leaving the system with inadequacy in capacity. The IDAES-Enterprise GEP model has been modified to include these extreme scenarios while keeping the model reasonably tractable. Specifically, a lazy constraint technique was implemented to check for capacity adequacy on an hourly basis over a large data set of aligned load-wind-solar profiles. As a vast majority of the capacity constraints will not be violated, the technique lowers computational expense by searching for violated capacity constraints over an “iterative manner,” adding those infeasible constraints back into the model. Results on a test case of the Southwest Power Pool shows that the lazy constraint technique significantly reduces retirements and increases installments of natural gas combined cycles and flexible natural gas units. It also reduces some retirements of coal units. These modifications provide a more reasonable estimation of required dispatchable power generation capacity to ensure feasibility during peak net load.

Liu, Peng↗

Integrating Concentrating Solar Power Technologies into the Hybrid Optimization and Performance Platform (HOPP)

As the world increases renewable energy deployment, there is an increasing interest in hybridizing various generation and storage technologies to maximize net benefit to the developer and/or off-taker. A particularly interesting combination of renewable technologies is concentrating solar power (CSP) with thermal energy storage (TES), photovoltaics (PV), and electrochemical battery energy storage (BESS). Due to the system complexity of CSP technology, it is difficult to evaluate the technological and financial performance of a CSP-PV hybrid system without detailed modeling of annual operations. To address this challenge, we have developed a modeling framework for evaluating the performance and financial viability of CSP systems hybridized with PV and battery technologies. This modeling effort incorporates CSP tower and trough systems into an existing modeling tool recently developed by NREL referred to as the Hybrid Optimization and Performance Platform (HOPP). This report outlines the modeling methodology as well as preliminary results from example case studies conducted using the model. The methodology describes: (i) the integration of CSP tower and troughs into HOPP using python interfaces to access System Advisor Model (SAM) underlining technology models, (ii) the mathematical formulation of the mixed integer linear program dispatch optimization model which optimizes operations of storage asset to either maximize system revenue or minimize operating cost while load following, (iii) the design analysis methods implemented within HOPP, and (iv) simulation clustering for the purposes of reducing computational expense. We exercise the model using a case study of a future scenario where we assume (i) CSP and PV technologies achieve the 2030 cost targets provided by the Solar Energy Technologies Office (SETO), (ii) battery costs reduce to the 2030 mid cost projection presented by NREL. Lastly, (iii) electricity prices for southern California in 2030 are provided by NREL's Cambium database, and (iv) a capacity payment of $150/kW-yr based on the system capacity factor during the to 100 net-load hours.

14 SOLAR ENERGY↗

Net-Zero Energy Home Grows Up: Lessons and Puzzles from 10 Years of Data; Preprint

In 2005, Habitat for Humanity of Metro Denver, with support from NREL and other partners, built one of the first homes in the US to achieve net-zero energy based on monitored data. A family of three moved into the house when it was completed and lives there still. The home has been monitored continuously for the past ten years. Although PV production has remained steady, net energy performance has varied each year. The home was a net producer of energy annually in each of the first three years and in the ninth year, but not in years four through eight. Over the years, the PV system provided between 124% and 64% of the home source energy use. Electricity use in the home increased steadily during the first eight years, even though no significant new appliance was introduced into the house, such as a window air conditioner. Miscellaneous electric loads and space heating, both strongly dependent on occupant behavior, appear to be primarily responsible for the observed increase in energy use. An interesting aspect of this case study is how, even within a single family, natural changes in occupant lifestyles over time (e.g., kids growing up, schedules changing) can substantially impact the overall energy intensity of a home. Data from the last ten years will be explored for lessons learned that can improve the way we design low-load homes without sacrificing comfort or convenience for the occupants, and how we can make realistic predictions of long-term energy performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Net-Zero Energy Home Grows Up: Lessons and Puzzles from 10 Years of Data

In 2005, Habitat for Humanity of Metro Denver, with support from NREL and other partners, built one of the first homes in the US to achieve net-zero energy based on monitored data. A family of three moved into the house when it was completed and lives there still. The home has been monitored continuously for the past ten years. Although PV production has remained steady, net energy performance has varied each year. The home was a net producer of energy annually in each of the first three years and in the ninth year, but not in years four through eight. Over the years, the PV system provided between 124% and 64% of the home source energy use. Electricity use in the home increased steadily during the first eight years, even though no significant new appliance was introduced into the house, such as a window air conditioner. Miscellaneous electric loads and space heating, both strongly dependent on occupant behavior, appear to be primarily responsible for the observed increase in energy use. An interesting aspect of this case study is how, even within a single family, natural changes in occupant lifestyles over time (e.g., kids growing up, schedules changing) can substantially impact the overall energy intensity of a home. Data from the last ten years will be explored for lessons learned that can improve the way we design low-load homes without sacrificing comfort or convenience for the occupants, and how we can make realistic predictions of long-term energy performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving the Regeneration of CO₂-Binding Organic Liquids with a Polarity Change

This paper describes an unusual solvent regeneration method unique to CO₂BOLs and other switchable ionic liquids; utilizing changes in polarity to shift the free energy of the system. The degree of CO₂ loading in CO₂BOLs is known to control the polarity of the solvent; conversely, polarity could be exploited as a means to control CO₂ loading. In this process, a chemically inert non-polar “antisolvent” is added to aid in de-complexing CO₂ from a CO₂-rich CO₂BOL. The addition of this polarity assist reduces temperatures required for regeneration of CO₂BOLs by as much as 76 °C. The lower regeneration temperatures realized with this polarity change allow for reduced solvent attrition and thermal degradation. Furthermore, the polarity assist shows considerable promise for reducing regeneration energy of CO₂BOL solvents, and separation of the CO₂BOL from the antisolvent is as simple as cooling the mixture below the upper critical solution temperature. Vapour-liquid equilibrium and liquid-liquid equilibrium measurements of a candidate CO₂BOL with CO₂ with and without an antisolvent were completed. From this data, we present the evidence and impacts of a polarity change on a CO₂BOL. Thermodynamic models and analysis of the system were constructed using ASPEN Plus, and forecasts preliminary process configurations and feasibility are also presented. Lastly, projections of solvent performance for removing CO₂ from a sub-critical coal fired power plant (total net power and parasitic load) are presented with and without this polarity assist and compared to DOE’s Case 10 MEA baseline.

Mathias, Paul M.↗

LAF-Net: A Deep Residual and Cross-Attention Framework for Day-Ahead Load Forecasting: Preprint

Accurate day-ahead load forecasting is essential for reliable power system operations and market efficiency. System operators such as the Midcontinent Independent System Operator (MISO) rely on forecasts from multiple vendors, yet combining them effectively remains a persistent challenge due to vendor-specific biases. This paper presents a novel LSTM-Attention Fusion Network with Error Representation (LAF-Net) that enhances day-ahead hourly load forecasting through deep residual learning and multi-modal cross-attention. The proposed model builds a historical error memory from past vendor performance and dynamically queries it with future hour context to generate adaptive, hour-specific trust weights for each vendor. A bounded residual correction further refines forecasts by mitigating systematic and temporally localized errors. Tested on real MISO LBA data with multi-vendor forecasts, LAF-Net consistently outperforms the best vendor baseline across all 38 LBAs, achieving more than a 40% reduction in system-level mean absolute error (MAE) during peak load hours relative to the best vendor baseline.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Role of Regional Connections in Planning for Future Power System Operations Under Climate Extremes

Identifying the sensitivity of future power systems to climate extremes must consider the concurrent effects of changing climate and evolving power systems. We investigated the sensitivity of a Western U.S. power system to isolated and combined heat and drought when it has low (5%) and moderate (31%) variable renewable energy shares, representing historic and future systems. We used an electricity operational model combined with a model of historically extreme drought (for hydropower and freshwater-reliant thermoelectric generators) over the Western U.S. and a synthetic, regionally extreme heat event in Southern California (for thermoelectric generators and electricity load). We found that the drought has the highest impact on summertime production cost (+10% to +12%), while temperature-based deratings have minimal effect (at most +1%). The Southern California heat wave scenario impacting load increases summertime regional net imports to Southern California by 10-14%, while the drought decreases them by 6-12%. Combined heat and drought conditions have a moderate effect on imports to Southern California (-2%) in the historic system and a stronger effect (+8%) in the future system. Southern California dependence on other regions decreases in the summertime with the moderate increase in variable renewable energy (-34% imports), but hourly peak regional imports are maintained under those infrastructure changes. By combining synthetic and historically driven conditions to test two infrastructures, we consolidate the importance of considering compounded heat wave and drought in planning studies and suggest that region-to-region energy transfers during peak periods are key to optimal operations under climate extremes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Societal decisions about climate mitigation will have dramatic impacts on eutrophication in the 21st century

Excessive nitrogen loading leads to degraded water quality that harms human and ecosystem health. Here, we examine the impact of changes in land use and land management for six combinations of socioeconomic pathways (SSPs) and climate outcomes and find that future societal choices will substantially impact riverine nitrogen loading (+54% to -7%) for the continental United States by the end-of-the-century. Regional impacts will be even larger. The increase in nitrogen loading is projected both for high emission pathways with increased food demand and for societal pathways that achieve high climate mitigation through increased biofuel production. Conversely, projected decreases in nitrogen loading are associated with future pathways with low food demand and no climate mitigation efforts. Thus, climate mitigation may have unintended consequences in the form of increased eutrophication, although some pathways suggests that limiting climate change and eutrophication need not be mutually exclusive. We find that changes in cropland, developed land, and fertilizer application rates are all important drivers in explaining the projected changes in nitrogen loading. Climate change–induced precipitation changes will further amplify the projected increase in nitrogen loading or offset the improvement in loading resulting in a net change of +1% to +68% by the end-of-the-century. Globally, vast portions of South, East, and Southeast Asia will also likely experience increased eutrophication by the end-of-the-century due to increased cropland area and agricultural intensification. These findings highlight the need to account for the impact of both societal and climate trends in designing strategies for managing inland and coastal water quality.

54 ENVIRONMENTAL SCIENCES↗

Design study of a laser-cooled infrared sensor

The performance of a solid-state optical refrigerator is the result of a complex interplay of numerous optical and thermal parameters. We present a first preliminary study of an optical cryocooler using ray-tracing techniques. A numerical optimization identified a non-resonant cavity with astigmatism. This geometry offered more efficient pump absorption by the YLF:10%Yb laser-cooling crystal compared to non-resonant cavities without astigmatism that have been pursued experimentally so far. Ray tracing simulations indicate that ~80% of the incident pump light can absorbed for temperatures down to ~100 K. Calculations of heat loads, cooling power, and net payload heat lift are presented. They show that it is possible to cool a payload to a range of 90–100 K while producing a net payload heat lift of 80 mW and 300 mW when pumping a YLF:10%Yb crystal with 20 W and 50 W at 1020 nm, respectively. This performance is suited to cool HgCdTe infrared detectors that are used for sensing in the 8–12 μm atmospheric window. While the detector noise would be ~6× greater at 100 K than at 77 K, the laser refrigerator would introduce no vibrations and thus eliminate sources of microphonic noise that are limiting the performance of current systems.

47 OTHER INSTRUMENTATION↗

Evaluating the Impact of Price-Responsive Load on Power Systems Using Integrated T&D Simulation: Preprint

This paper explores the advantages and challenges of simulating price-responsive load (PRL) interactions with large-scale power systems using integrated transmission and distribution (T&D) models. This analysis uses the Integrated Grid Modeling System (IGMS) software to capture 'ISO-to-appliance' simulations using a synthetic T&D model built on the PJM 5 Bus transmission network with multiple full-scale taxonomy feeders that include physics-based models of thousands of PRLs. The results show substantial differences in the impacts of PRLs between integrated T&D and transmission-only (T-only) models. Similarly differences are observed between the price response of individual distribution feeders and the corresponding transmission bus in the integrated T&D simulations, which cannot be captured in T-only simulations. Experiments include both traditional price responsive load reductions and price-driven load increases during low net demand periods driven by high daytime generation from distributed generation-based photovoltaics (DGPV).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ducted Fuel Injection Provides Consistently Lower Soot Emissions in Sweep to Full-Load Conditions

Earlier studies have proven how ducted fuel injection (DFI) substantially reduces soot for low- and mid-load conditions in heavy-duty engines, without significant adverse effects on other emissions. Nevertheless, no comprehensive DFI study exists showing soot reductions at high- and full-load conditions. This study investigated DFI in a single-cylinder, 1.7-L, optical engine from low- to full-load conditions with a low-net-carbon fuel consisting of 80% renewable diesel and 20% biodiesel. Over the tested load range, DFI reduced engine-out soot by 38.1–63.1% compared to conventional diesel combustion (CDC). This soot reduction occurred without significant detrimental effects on other emission types. Thus, DFI reduced the severity of the soot–NO x tradeoff at all tested conditions. While DFI delivered considerable soot reductions in thepresent study, previous DFI studies at low- and mid-load conditions delivered larger soot reductions (>90%) compared to CDC operation at the same conditions. Therefore, the DFI configuration used here has been deemed nonoptimal (in terms of parameters such as the injector-spray and piston geometries), and several improvements are recommended for future studies with high-load DFI. Further, these improvements include employing better spray-duct alignment, a deeper piston bowl with a smaller injector umbrella angle, and a fuel injector that opens and closes faster. The study also suggests future research to make DFI ready for commercialization, such as metal-engine tests to ensure desirable DFI performance over an engine’s complete speed/load map. Overall, this study supports the continued development and commercialization of DFI to meet upcoming emissions regulations for heavy-duty vehicles. Specifically, multicylinder engine experiments and CFD simulations should be utilized to optimize the performance and clarify the full potential of DFI.

33 ADVANCED PROPULSION SYSTEMS↗

Infinitely rugged intra-cage potential energy landscape in metallic glasses caused by many-body interaction

The absence of translational symmetry in glassy materials poses a significant challenge in establishing effective structure-property relationships in real space. Consequently, the potential energy landscape (PEL) in phase space is widely utilized to comprehend the complex phenomena in glasses. The classical PEL features a two-scale profile comprising mega-basins and sub-basins, corresponding to α-relaxations (e.g. glass transition) and β-relaxations (e.g. local cage-breaking atomic rearrangements), respectively. Recent studies, however, reveal that sub-basins are not smooth and contain finer structures, the origins of which remain elusive. Here we probe the smoothness of sub-basin bottoms in glasses' PEL by introducing small intra-cage cyclic loading and then measuring the net changes in atomic-level stresses. Compared to glasses with pair interaction, glasses with many-body interaction exhibit orders-of-magnitude larger and loading-dependent stress changes even before the first cage-breaking event takes place, which reflect much more feature-rich sub-basins. We further demonstrate this stark contrast stems from the spatial distribution of individual atom's constraining force field. Specifically, at vanishing perturbations, many-body interactions disrupt the positive-definite synchrony in energy variations of the perturbed atom and the whole system, causing inherently less confined atomic responses and infinitely rugged sub-basins. The implications of these findings for the selective addition or removal of fine structures in the PEL and the subsequent tuning of glassy materials' responses to external stimuli are also explored.

36 MATERIALS SCIENCE↗

Heat Loss Characteristics and Energy Use of Piperazine with the Advanced Stripper (PZAS) at the UT-SRP Pilot Plant

Heat duty and heat loss were measured at the pilot plant at UT Austin. Heat loss was measured with energy balances using water. Heat loss was studied using surface temperature measurements over 68 different locations at the pilot plant. Surface temperature measurements indicated that bare metal surfaces were the primary source of heat loss from the pilot plant. Heat loss from bare metal surfaces was at least 50% controlled by natural convection and in many cases was as high as 75% natural convection controlled. Measured heat loss at the pilot plant was 20100 BTU/hr and overall heat loss did not show any dependence on the heat rate of the plant. Compared to PZAS™ at the National Carbon Capture Center, heat loss relative to heat rate was higher at 38%. The relative heat loss at the pilot plants was found to decrease by 20% per MW of added capacity. Measured net heat duty was found to be dependent on measured lean loading and cold rich bypass flow rate. Measured net heat duty was between 2.2 and 2.4 GJ/tonne at an optimum lean loading of 0.2–0.21 mol/mol. Data reconciliation by Aspen Plus® Data Fit™ underpredicted CO2 flow rate by 20% due to an overprediction of lean loading by 19%, indicating a necessary change in thermodynamic parameters in the model. This resulted in an over prediction of heat duty by 33% on average.

Amine scrubbing, stripper, energy requirement, hea↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ducted fuel injection with Low-Net-Carbon fuels as a solution for meeting future emissions regulations

Several studies have proven how ducted fuel injection (DFI) reduces soot emissions for compression-ignition engines. Nevertheless, no comprehensive study has investigated how DFI performs over a load range in combination with low-net-carbon fuels. In this study, optical-engine experiments were performed with four different fuels—conventional diesel and three low-net-carbon fuels—at low and moderate load, to measure emissions levels and performance. The 1.7-liter single-cylinder optical engine was equipped with a high-speed camera to capture natural luminosity images of the combustion event. Conventional diesel and DFI combustion were investigated at four different dilution levels (to simulate exhaust-gas recirculation effects), from 14 to 21 mol% oxygen in the intake. At a given dilution level, with commercial diesel fuel, DFI reduced soot by 82% at medium load, and 75% at low load without increasing NO x . The results further show how DFI with dilution reduces soot and NO x without compromising engine performance or other emission types, especially when combined with low-net-carbon fuels. DFI with the oxygenated low-net-carbon blend HEA67 simultaneously reduced soot and NO x by as much as 93 % and 82 %, respectively, relative to conventional diesel combustion with commercial diesel fuel. These soot and NO x reductions occurred while lifecycle CO 2 was reduced by at least 70 % when using low-net-carbon fuels instead of conventional diesel. All emissions changes were compared with future emissions regulations for different vehicle sectors to investigate how DFI can be used to facilitate achievement of the regulations. Finally, the results show how the DFI cases fall below several future emissions regulation levels, rendering less need for aftertreatment systems and giving a possible lower cost of ownership.

33 ADVANCED PROPULSION SYSTEMS↗

HCCI Load Expansion Opportunities Using a Fully Variable HVA Research Engine to Guide Developments of a Production Intent Cam-Based VVA Engine: The Low Load Limit

While the potential emissions and efficiency benefits of HCCI combustion are well known, realizing the potentials on a production intent engine presents numerous challenges. In this study we focus on identifying challenges and opportunities associated with a production intent cam-based variable valve actuation (VVA) system on a multi-cylinder engine in comparison to a fully flexible, naturally aspirated, hydraulic valve actuation (HVA) system on a single-cylinder engine, with both platforms sharing the same GDI fueling system and engine geometry. The multi-cylinder production intent VVA system uses a 2-step cam technology with wide authority cam phasing, allowing adjustments to be made to the negative valve overlap (NVO) duration but not the valve opening durations. On the single cylinder HVA engine, the valve opening duration and lift are variable in addition to the NVO duration. The content of this paper is limited to the low-medium operating load region at 2000rpm. Using different injection strategies, including the NVO pilot injection approach, the single-cylinder engine is operated over a load range from 160-390 kPa net IMEP at 2000 rpm. Changes to valve opening duration on the single-cylinder HVA engine illustrate opportunities for load expansion and efficiency improvement at certain conditions. For instance, the low load limit can be extended on the HVA engine by reducing breathing and operating closer to a stoichiometric air fuel ratio (AFR) by using valve deactivation. The naturally aspirated engine used here without external EGR confirmed that as operating load increases the emissions of NOx increases due to combustion temperature. NOx emissions are found to be one limitation to the maximum load limitation, the other being high pressure rise rate. It is found that the configuration of the production intent cam-based system represents a good compromise between valve lift and duration in the low to medium load region. Changing the extent of charge motion and breathing via valve deactivation prove beneficial at moderating the pressure rise rate and combustion stability and extending the low load limit at 2000rpm on the HVA engine. It also confirms that strategies using a pilot fuel injection are beneficial at low operating loads but that as operating load is increased, the benefits of multiple injection diminish to the point where a single injection offers the best performance.

33 ADVANCED PROPULSION SYSTEMS↗