GEANT4 simulation of fast neutron interactions in detectors based on Bismuth Germanate (Bi4Ge3O12)
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
For the analysis of radiation risks to astronauts and planning exploratory space missions, detailed knowledge of particle spectra is an important factor. Detailed measurements of the energetic particle radiation environment on the surface of Mars have been made by the Mars Science Laboratory Radiation Assessment Detector (MSL-RAD) on the Curiosity rover since August 2012, and particle fluxes for a wide range of ion species (up to several hundred MeV/u) and high energy neutrons (8 - 1000 MeV) have been available for the first 200 sols. Although the data obtained on the surface of Mars for 200 sols are limited in the narrow energy spectra, the simulation results using the Badhwar-O'Neill galactic cosmic ray (GCR) environment model and the high-charge and energy transport (HZETRN) code are compared to the data. For the nuclear interactions of primary GCR through Mars atmosphere and Curiosity rover, the quantum multiple scattering theory of nuclear fragmentation (QMSFRG) is used, which includes direct knockout, evaporation and nuclear coalescence. Daily atmospheric pressure measurements at Gale Crater by the MSL Rover Environmental Monitoring Station are implemented into transport calculations for describing the daily column depth of atmosphere. Particles impinging on top of the Martian atmosphere reach the RAD after traversing varying depths of atmosphere that depend on the slant angles, and the model accounts for shielding of the RAD by the rest of the instrument. Calculations of stopping particle spectra are in good agreement with the RAD measurements for the first 200 sols by accounting changing heliospheric conditions and atmospheric pressure. Detailed comparisons between model predictions and spectral data of various particle types provide the validation of radiation transport models, and thus increase the accuracy of the predictions of future radiation environments on Mars. These contributions lend support to the understanding of radiation health risks to astronauts for the planning of various mission scenarios.
Detector, using point anode, minimizes problem of oblique tracks by permitting construction of very thin counter. Detector is useful in cosmic ray and high energy physics research and X-ray and neutron diffraction technology.
Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and n – γ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty trans-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and γ-ray multiplicities and spectra. Here, the details of both detector assemblies are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.
A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.
The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector. One of the difficult technical challenges is to discriminate the chlorine-based chemical agents. Especially, CN, CNB, CNS and CG have similar chemical compositions to make it hard to discriminate them with a higher confidence. Current identification algorithms for PINS systems with 252-Cf sources have been improved and updated continuously as more field data became available, and new algorithms was studied to complement the current algorithms by adopting the Gaussian Bayes classifier. These new algorithms were intended to be applied to a subset of chlorine-based chemical agents, and their main goal is discriminate CN, CNB, CNS and CG with their ratios of the chlorine neutron inelastic 1763keV peak to the chlorine thermal neutron capture 1959keV peak, which is referred to as the “Cl i/c” or “clic” ratio in this study. The Cl i/c ratios were assumed to follow Gaussian distributions with the means and the standard deviations unique to their corresponding chemical agents. The prior probabilities of these four chemical agents were optimized with a collection of field data to achieve the best performance in terms of precision or positive predictive value (PPV). Finally, their posterior probabilities as functions of the Cl i/c ratio were implemented in the current version of PINS analysis software in order to be tested with more field data.
The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.
SNM verification can be accomplished via two methods i.e. destructive analysis (DA) or nondestructive analysis (NDA). The DA modes are much more accurate compared to NDA modes; nevertheless, the sample's physical integrity is destroyed in the process. Techniques such as ICP-MS, ID-ICP-MS, TI-MS are few examples of DA, where a bulk material is ground and mixed with a solution (some form of acid) to acquire a homogenous sample. In contrast, NDA modes utilize signals emitted by the sample such as gamma, neutrons, light, or heat to analyze samples under investigation. HPGe detectors are some of the most frequently used gamma detectors to assay SNM. However, in a high activity scenario it provides a large uncertainty and sometimes becomes unfeasible to measure low energy gamma rays. Meanwhile, neutron detectors are not affected by the gamma background, therefore they can be used in addition to the gamma detectors to verify total fissile mass ({sup 235}U + {sup 239}Pu) of SNM. The AWCC is one of the thermal neutron NDA systems developed at the Los Alamos National Laboratory (LANL). It consists of 42 {sup 3}He detectors to measure gross neutrons (singles), coincidence neutrons (doubles), higher order multiplicity counting (triples, quadruples, etc.). It can effectively operate in both active and passive neutron interrogation modes. It can utilize AmLi, AmBe, or {sup 252}Cf active interrogation neutron sources. It is used to verify declared fissile mass ({sup 235}U or {sup 239}Pu) present in SNM. Objectives: Calibrate HPGe and AWCC for lightly irradiated (with enough {sup 137}Cs gamma background) ∼93% enriched HEU fuels; Verify fissile mass ({sup 235}U +{sup 239}Pu) content using AWCC and HPGe; Model and benchmark AWCC in MCNP6. Neutron coincidence and multiplicity counting: Two or more neutrons are coincident if they are detected by the system within the specified gate window; In AWCC: Gate window is 128 μsec; Induced fission in fissile material such as {sup 235}U and {sup 239}Pu - emission of time correlated neutrons - Singles, Doubles, Triples, or Quadruples; No induced fission in non-fissile materials- no correlated neutrons - only singles. SNM can be verified with high accuracy and precision using gamma and neutron NDA instruments such as HPGe and AWCC. Interaction with thermal neutrons. Non-fissile atoms - do not emit correlated neutrons. Fissile atoms - emit correlated neutrons during induced fission events. The time correlated neutrons can be detected by using coincidence or multiplicity counters such as AWCC. Likewise, {sup 235}U produces 186 keV gamma peak that can be measured by a HPGe gamma detector. Counts under 186 keV gamma peak provide information about {sup 235}U content. Combining AWCC and HPGe results can provide better understanding of special nuclear material under investigation.
The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.
A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.
Analytic and experimental investigations of the interactions of high-energy protons with spacecraft materials and light nucleus atoms were conducted. Irradiation of typical materials for scintillation detectors using accelerator-produced energetic protons and associated theoretical calculations indicate activity within detectors produced by this mechanism is significant to detection of low-level cosmic gamma radiation. Samples of several materials were flown aboard Skylab to obtain measures of the neutron and proton flux environment. Extremely weak activity was produced in the samples. Calculations of interactions of intermediate-energy protons with light nuclei were performed and a more complete theoretical model programmed for digital computation. Preliminary results appear promising for calculating products of such interactions.
From the late 1960s to 1985, Lawrence Livermore National Laboratory (LLNL) undertook a series of ‘pulsed sphere’ experiments for 32 materials involving 148 different experiments using 75 different spheres to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d, n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transformer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge on tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. The neutron time of flight was measured at a detector outside a collimator. The program was intended to be comprehensive with numerous targets of various thicknesses spanning the periodic table from H to 239 Pu. Five different neutron detectors were utilized to avoid possible systematic errors due to differences in detector responses. Further, these measurements were designed with the aim that the simple geometry of the measurements could be easily simulated to validate Monte Carlo transport codes and nuclear data libraries. As a result, these benchmarks have been extensively used in the validation of ENDL, ENDF and other libraries. Two experiments selected as benchmark cases in this evaluation are: 1) target assembly without material sphere (blank run), and 2) target assembly with a hollow polyethylene sphere, 1.8 mean free path (mfp) or 16.56 cm thick.
Pulsed-neutron die-away (PNDA) experiments were completed at Lawrence Livermore National Laboratory (LLNL). The goal of these experiments was to provide a benchmark to validate thermal neutron scattering laws of H 2 O. The experiment was conducted with a deuterium-tritium (D-T) neutron generator producing pulses of 14.1 MeV neutrons that impinged on a moderating target. The neutrons scattered and thermalized within the target and were counted as a function of time using Helium-3 ( 3 He) detectors that surrounded the target. These data provide a time-decay profile of the neutron population from which the time eigenvalue of the experiment is calculated. The time eigenvalue quantity α represents the integral parameter of interest. This report describes the measurements for H 2 O targets. The measurements were conducted over several days beginning on October 23rd, 2023. All measurements were completed at the low-scatter facility at LLNL. The evaluation identifier is FUND-LLNL-DT-H2O-PNDA-001.
The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.
Temperature measurement is a key factor in the safe and reliable operation of nuclear reactors. Thermocouples and resistance temperature detectors (RTDs) are among the most common and reliable tools deployed for temperature measurement, and some are capable of operating in extreme environments such as very high temperature and neutron radiation fields anticipated in nuclear thermal propulsion (NTP) or fission surface power. These devices are known to exhibit drifting behavior in their temperature readings throughout their operational lifetimes. Here, to help select appropriate instrumentation, it is important to identify the factors that influence drift as well as typical behavior in these environments. This work is focused on identifying contributing factors in the performance of thermocouples and RTDs. An extensive literature review is included that discusses several experimental results in different environments. Although individual instrument performance may vary with construction methods, materials selection, and vendors, this review aims to assist in the selection process and identify typical expected behaviors of several devices.
The Seven Percent Critical Experiment, or 7uPCX, is a system that mimics the physics of light water nuclear reactor systems by using uranium dioxide fuel pins at an enrichment of approximately 7%. 7uPCX is often used for benchmarking and nuclear data purposes. As part of a collaboration between Lawrence Livermore National Laboratory, Los Alamos National Laboratory, Sandia National Laboratories, and the Institut de Radioprotection et de Sûreté Nucléaire, measurements were performed in support of a high-multiplication, subcritical benchmark candidate for a thermal system. The measurements were completed by making subcritical configurations using the fuel loading pattern of a well-documented configuration of the Seven Percent Critical Experiment at Sandia National Laboratories, which exists as a benchmark in the International Criticality Safety Benchmark Evaluation Project handbook. These measurements, which aimed to capture multiplications ranging from approximately 10 to 1,000, also serve as an intercomparison between both the fielded detector systems and analysis methodologies with the goal of better characterizing the detectors and their ability to capture the state of the criticality these types of systems. Los Alamos National Laboratory’s measurements for this collaboration were made with five linked helium-3 based neutron multiplicity detectors placed on the periphery of the reactor tank beyond the infinite reflector thickness of water, and four organic scintillators placed in dry-wells in-reactor near the edge of the upper fuel grid plate. This work captures the Los Alamos National Laboratory measurements, the Rossi-α and Feynman-Y results, provides an intercomparison between the results of the 3 He neutron detectors and the organic scintillators, compares to simulation where possible, and expands on future work.
Advancing neutron detection and analysis techniques for complex radiation environments is an ongoing focus in nuclear instrumentation and monitoring. This proposal presents research and development of a generalized real-time neutron monitoring and analysis system, applicable to any detector capable of producing time-tagged neutron count data. While the work is demonstrated using the Neutron Multiplication Analysis Detector (NoMAD), a modular 15-tube helium-3 (He-3) array, due to its availability, spatial resolution, and flexible deployment, the methods developed are extensible to other systems, including organic scintillators and fast digital detectors. This research investigates two complementary analytical techniques for real-time characterization of neutron emitting sources: neutron multiplicity estimation based on the Hage-Cifarelli formalism and spatial localization using supervised machine learning applied to spatial count rate patterns. These methods are designed to operate under dynamic, evolving conditions such as fuel debris retrieval or reactor startup, where neutron-emitting material geometries may be partially unknown or changing over time. By integrating statistical neutron emission data with spatial localization, this research aims to develop and evaluate methods for real time neutron monitoring, source characterization, and material verification. Key contributions include implementation of a low-latency data pipeline for continuous neutron multiplicity analysis, development and validation of machine learning models for spatial inference, and experimental evaluation of system performance under variable measurement conditions. The outcomes are intended to support applications in nuclear safeguards, verification, emergency response, and reactor startup.
The landmark detection of both gravitational waves (GWs) and electromagnetic (EM) radiation from the binary neutron star merger GW170817 has spurred efforts to streamline the follow-up of GW alerts in current and future observing runs of ground-based GW detectors. Within this context, the radio band of the EM spectrum presents unique challenges. Sensitive radio facilities capable of detecting the faint radio afterglow seen in GW170817, and with sufficient angular resolution, have small fields of view compared to typical GW localization areas. Additionally, theoretical models predict that the radio emission from binary neutron star mergers can evolve over weeks to years, necessitating long-term monitoring to probe the physics of the various postmerger ejecta components. These constraints, combined with limited radio observing resources, make the development of more coordinated follow-up strategies essential—especially as the next generation of GW detectors promises a dramatic increase in detection rates. Here, we present RADAR, a framework designed to address these challenges by promoting community-driven information sharing, federated data analysis, and system resilience, while integrating AI methods for both GW signal identification and radio data aggregation. We show that it is possible to preserve data rights while sharing models that can help design and/or update follow-up strategies. We demonstrate our approach through a case study of GW170817, and discuss future directions for refinement and broader application.