Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Luminescence properties of europium doped and sodium co-doped LiCaAlF 6

This paper serves as a literature review of scintillating thermal neutron detectors, along with a study of sodium and europium doped LiCaAlF 6 (LiCAF) polycrystalline material. A set of polycrystalline LiCAF material was synthesized with 2 molar percent of europium (Eu 2+ ) and co-doped with 0, 1, and 2 molar percent of sodium (Na + ), with a stoichiometric synthesis approach in a glassy-carbon crucible. The quantum yield and photoluminescence spectrum at room temperature was analyzed. For the first time, we have demonstrated that Na-co-doping directly alters the quantum yield. The quantum yield for LiCAF:Eu 2+ , with 0, 1, and 2 molar percent of sodium (Na + ) was 0.578, 0.635, and 0.580, respectively. The photoluminescence (PL) spectrum was also analyzed for all samples. The photo-luminescence excitation (PLE) spectrum showed a maximum at 300 nm, while the emission spectrum showed a maximum at 370 nm, corresponding to the Eu 2+ 5d-4f transitions.

36 MATERIALS SCIENCE↗

HighNESS conceptual design report: Volume II. The NNBAR experiment.

A key aim of the HighNESS project for the European Spallation Source is to enable cutting-edge particle physics experiments. This volume presents a conceptual design report for the NNBAR experiment. NNBAR would exploit a new cold lower moderator to make the first search in over thirty years for free neutrons converting to anti-neutrons. The observation of such a baryon-number-violating signature would be of fundamental significance and tackle open questions in modern physics, including the origin of the matter-antimatter asymmetry. This report shows the design of the beamline, supermirror focusing system, magnetic and radiation shielding, and anti-neutron detector necessary for the experiment. A range of simulation programs are employed to quantify the performance of the experiment and show how background can be suppressed. For a search with full background suppression, a sensitivity improvement of three orders of magnitude is expected, as compared with the previous search. Civil engineering studies for the NNBAR beamline are also shown, as is a costing model for the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase I Final Report

Explore the source record for details and available documents.

36 MATERIALS SCIENCE↗

Comparing Control Performance Between Simulation and Experiment using the Microreactor Automated Control System Testbed

In the advanced reactor domain, a flexible and scalable software/hardware infrastructure is crucial for integrating and validating various control technologies. This study used the Microreactor Automated Control System (MACS) hardware platform as a testbed. MACS was originally designed to mirror Idaho National Laboratory (INL)'s Microreactor Applications Research Validation and Evaluation (MARVEL), a 85-kW thermal fission microreactor. It features control drums for simulated reactivity control; lights that function as a surrogate reactor core, with the brightness being proportional to the reactor power; and light sensors that emulate neutron detectors. To transform MACS into a physical twin of MARVEL for evaluating control methods, the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software was employed. This software integrated the hardware with two models of the MARVEL core, based on Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The study aimed to demonstrate the gap between control theory and actual practice—a gap that often necessitates empirical adjustments such as control gain retuning, filters, time discretization, and integrator anti-windup measures. Controllers were developed based on increasingly complex simulations without hardware, starting from the base MARVEL model and then introducing actuator saturation constraints and sensor noise. The final control strategy was then tested using MACS, and a comparative performance analysis was conducted.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Monitoring the SNS basement neutron background with the MARS detector

Here, we present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. Furthermore, these data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be 1.20 ± 0.56 neutrons/m 2 /MWh for neutron energies above ~3.5 MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Manufacturing and characterization of a boron-loaded fast-cured plastic organic scintillator

A novel fast-cured, boron-loaded, plastic organic scintillator was developed and characterized. A diisopropylnaphthalene-containing scintillator was manufactured in minutes with the addition of two commercially available fast-curing monomers, isobornyl acrylate (IBOA) and 1,6-Hexanediol dimethacrylate (HDDMA). Further, the light yield of the device was measured to be approximately 70% relative to a similarly sized, but several-year-aged, EJ-276 detector. Using a coincidence capture technique, the neutron capture light output was found to be 87.7 ± 4.2 keVee, which was 1.47 ± 0.07 greater than the light output from a 59.5 keV electron. Producing a viable fast-cured and thermal-neutron-sensitive detector enables the capability to pursue cost-effective 3D printed thermal neutron detectors in a timely manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron time-of-flight detectors (nTOF) used at Sandia’s Z-Machine

Neutron time-of-flight (nTOF) detectors have been used on Sandia National Laboratories’ Z-Machine for inertial confinement fusion and magnetized liner fusion experiments to infer physics parameters including the apparent fuel-ion temperature, neutron yield, the magnetic-radius product (BR), and the liner rho-r. Single-paddle, dual-paddle, and co-axial scintillation nTOF detectors are used in axial lines-of-sight (LOS) and LOS that are 12° from the midplane. Detector fabrication, characterization, and calibration are discussed.

Chandler, G. A. (ORCID:0000000219640927)↗

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors↗

Using real-time nuclear activation detectors for measuring neutron yields from D(D, T)n reactions on the national ignition facility (NIF)

The National Ignition Facility (NIF) has 48 Real-Time Nuclear Activation Detectors distributed around the target chamber capable of measuring deuterium-triton reaction neutron yields with high precision. Here, in this work, we extend this functionality to deuterium–deuterium (DD) reaction neutrons using a nuclear reaction that occurs in the detector’s scintillator material. The corresponding decay of the activated material has a very short half-life of 5 s, which necessitates rapid data collection immediately following an experiment. In this regime, dead time can be very high (>50%) adding significant uncertainty to the measurement. To combat this, we have developed a dead time model that can self-consistently describe the measured data. Initial results show reasonable agreement (within 20%) with DD neutron yields from neutron time-of-flight spectrometers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Triple-mode detector for fast neutrons, slow neutrons, and gamma ray spectroscopy

This disclosure provides systems, methods, and apparatus related to neutron detection and gamma ray detection. In one aspect, a detector comprises a scintillator structure that comprises an organic scintillator and an inorganic scintillator. The organic scintillator is in the form of one or more elements of a specified length. The inorganic scintillator is in the form of one or more elements of the specified length. First ends of the one or more organic scintillator elements and first ends of the one or more inorganic scintillator elements define a first surface. Second ends of the one or more organic scintillator elements and second ends of the one or more inorganic scintillator elements define a second surface.

Derenzo, Stephen↗

Model Development and Analysis of a High-Fidelity Neutron Transport Sensor: The Quadrupole Detector Concept for Measurement of the Neutron Flux Gradient

Accurate reconstruction of the neutron flux distribution within a reactor core is essential for safe and efficient reactor operation. Traditional power shape synthesis in Light Water Reactors relies on hundreds of in-core detectors. However, this approach becomes impractical for Advanced Reactors and Microreactors due to limited space and harsh environments. To address this challenge, we propose a data-driven methodology that combines high-fidelity modeling with real-time ex-core sensor measurements, enabling the reconstruction of core power distribution while minimizing the reliance on intrusive in-core instrumentation. This project began in FY24 and achieved two initial milestones: (1) the definition of a three-year development plan for a Digital Twin framework and (2) the development of high-fidelity neutronics models of the Purdue University Reactor One (PUR-1) using both MCNP6 and OpenMC. The PUR-1 reactor, a zero-power facility, was selected due to its suitability for neutronics-focused modeling and the availability of experimental data for validation. Both models were benchmarked using neutron flux measurements obtained from irradiated gold foils, which were strategically placed within the core during a dedicated campaign in July 2024. This report marks the continuation and completion of those foundational tasks. The OpenMC model has been refined (improved geometric accuracy, expanded cross-section libraries, and refined sampling) and validated using additional experimental data. An updated sensor design—based on quadrupole configuration—was designed to measure both ex-core flux and its spatial gradient. These measurements will serve as inputs to a neural network-based reconstruction algorithm. Finally, the methodology was demonstrated on a two-dimensional test case representative of the heterogeneous material composition of the PUR-1 reactor core. A neural network implementation of the Kirchhoff-Helmholtz integral equation was employed to solve the boundary value problem using peripheral sensor measurements. The preliminary results confirm the strong potential of the proposed approach for accurate and minimally invasive neutron flux reconstruction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron time of flight (nToF) detectors for inertial fusion experiments

Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. Here, we present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗