Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL SPECTRUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Evaluation of a novel mid-infrared pyrometer for dynamic material experiments

Temperature is a complicated thermodynamic parameter to measure in dynamic compression experiments. Optical pyrometry is a general-purpose “work-horse” technique for measuring temperature from a radiant surface on these experimental platforms. The optical pyrometry channels are commonly held to the visible or Near-Infrared spectrum, which provides high fidelity temperature measurement for shock temperature above ∼1200–1500 K. However, low temperature (T < 1200 K) dynamic material experiments, including low pressure or quasi-isentropic studies, as well as experiments with complex thermodynamic paths, require Mid-Infrared (Mid-IR) for high fidelity measurements. This article outlines the design, testing, and characterization of a novel Mid-IR pyrometer system that can be configured between 2.5 and 5.0 µm, suitable for lower temperature measurements and for increasing the fidelity and precision of higher temperature measurements. Experimental validation was done on two separate gas gun platforms, with two separate impact velocities, achieving temperatures between 450 and 1100 K.

Dutra, E. C. (ORCID:0000000167649195)↗

Phenomenology of bubble size distributions in a first-order phase transition

In a cosmological first-order phase transition (FOPT), the true and false vacuum bubble radius distributions are not expected to be monochromatic, as is usually assumed. Consequently, Fermi balls (FBs) and primordial black holes (PBHs) produced in a dark FOPT will have extended mass distributions. We show how gravitational wave (GW), microlensing and Hawking evaporation signals for extended bubble radius/mass distributions deviate from the case of monochromatic distributions. The peak of the GW spectrum is shifted to lower frequencies, and the spectrum is broadened at frequencies below the peak frequency. Thus, the radius distribution of true vacuum bubbles introduces another uncertainty in the evaluation of the GW spectrum from a FOPT. The extragalactic gamma-ray signal at AMEGO-X/e-ASTROGAM from PBH evaporation may evince a break in the power-law spectrum between 5 MeV and 10 MeV for an extended PBH mass distribution. Optical microlensing surveys may observe PBH mass distributions with average masses below 10 -10 M ⊙ , which is not possible for monochromatic mass distributions. This expands the FOPT parameter space that can be explored with microlensing.

Marfatia, Danny [Univ. of Hawaii at Manoa, Honolul↗

Ultra-narrow-linewidth hybrid-integrated self-injection locked laser at 780 nm

Narrow-linewidth lasers are essential across a wide range of applications, including classical and quantum sensing, trapped ion systems, position/navigation/timing systems, optical clocks, and microwave frequency synthesizers. In the visible and near-visible spectrum, low-noise lasers are particularly important for laser trapping and cooling techniques, which are vital for trapped ion quantum computing, sensing, and atomic clocks. In this context, our work showcases a hybrid-integrated narrow-linewidth laser that operates at 780 nm, achieving a self-heterodyne linewidth of 105 Hz. To validate the experimental results, we performed a numerical analysis that combines insights from a many-body theory applied to the gain region with a travelling-wave model to capture the laser dynamics. Our investigation further delves into how the linewidth of the self-injection locked lasers is influenced by the parameters of micro-ring resonators, aiming to assess the potential for achieving Hz-level integrated laser linewidths at 780 nm. This work not only demonstrates the technical feasibility of Hz-level narrow-linewidth lasers but also lays the groundwork for future explorations in the field.

Prokoshin, Artem (ORCID:0009000699760238)↗

Multi-coat polymer photonic crystal films

Polymer composite photonic crystal materials are disclosed as coatings and topcoats which have high reflection (>30%) in a specific range of the electromagnetic spectrum, such as ultraviolet (<400 nm), visible (Vis, 400 nm-700 nm), or near-infrared radiation range (NIR, 700-2000 nm), and relatively low reflection (<20% reflection) in a second, different range of the electromagnetic spectrum. Surprisingly, it was found that through a formulation and additives approach, the optical properties of polymer composite photonic crystal films can be selectively modified from a variety of different coating methods, including spray deposition.

Pearson, Ryan Michael↗

Consistency between reflection momentum-resolved electron energy loss spectroscopy and optical spectroscopy measurements of the long-wavelength density response of Bi 2 Sr 2 CaCu 2 O 8 + x

The density fluctuation spectrum captures many fundamental properties of strange metals. Using momentum-resolved electron energy-loss spectroscopy (M-EELS), we recently showed that the density response of the strange metal Bi 2 Sr 2 CaCu 2 O 8+x (Bi-2212) at large momentum, q, exhibits a constant-in-frequency continuum reminiscent of the marginal Fermi liquid (MFL) hypothesis of the late 1980s. However, reconciling this observation with infrared (IR) optics experiments, which show a well-defined plasmon excitation at q ~ 0, has been challenging. Here we report M-EELS measurements of Bi-2212 using 4× improved momentum resolution, allowing us to reach the optical limit. For momenta q < 0.04 r.l.u., the M-EELS data show a plasmon feature that is quantitatively consistent with IR optics. For q > 0.04 r.l.u., the spectra become incoherent with an MFL-like, constant-in-frequency form. Here we speculate that, at finite frequency, ω, and nonzero q, some attribute of this Planckian metal randomizes the probe electron, causing it to lose information about its own momentum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intrinsic donor-bound excitons in ultraclean monolayer semiconductors

The monolayer transition metal dichalcogenides are an emergent semiconductor platform exhibiting rich excitonic physics with coupled spin-valley degree of freedom and optical addressability. Here, we report a new series of low energy excitonic emission lines in the photoluminescence spectrum of ultraclean monolayer WSe 2 . These excitonic satellites are composed of three major peaks with energy separations matching known phonons, and appear only with electron doping. They possess homogenous spatial and spectral distribution, strong power saturation, and anomalously long population (>6 µs) and polarization lifetimes (>100 ns). Resonant excitation of the free inter- and intravalley bright trions leads to opposite optical orientation of the satellites, while excitation of the free dark trion resonance suppresses the satellites' photoluminescence. Defect-controlled crystal synthesis and scanning tunneling microscopy measurements provide corroboration that these features are dark excitons bound to dilute donors, along with associated phonon replicas. Our work opens opportunities to engineer homogenous single emitters and explore collective quantum optical phenomena using intrinsic donor-bound excitons in ultraclean 2D semiconductors.

36 MATERIALS SCIENCE↗

Kerr-lens mode-locked Cr:ZnS oscillator reaches the spectral span of an optical octave

We report, to the best of our knowledge, the first super-octave femtosecond polycrystalline Cr:ZnS laser at the central wavelength 2.4 µm. The laser is based on a non-polarizing astigmatic X-folded resonator with normal incidence mounting of the gain element. The chromatic dispersion of the resonator is controlled with a set of dispersive mirrors within one third of an optical octave over 2.05–2.6 µm range. The resonator’s optics is highly reflective in the range 1.8–2.9 µm. The components of the oscillator’s output spectrum at the wavelengths 1.6 µm and 3.2 µm are detected at –60 dB with respect to the main peak. Average power of few-cycle Kerr-lens mode-locked laser is 1.4 W at the pulse repetition frequency 79 MHz. That corresponds to 22% conversion of cw radiation of Er-doped fiber laser, which we used for optical pumping of the Cr:ZnS oscillator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopic Properties of Americium(III) in Mineral Acid Media

We report the preparation and optical characterization of three solutions of Am(III) in common aqueous (aq.) mineral acids (HCl, HNO 3 and HBr), including absorption, emission, and Raman vibrational analyses. To our knowledge, this study provides the first detailed absorption spectra of Am(III) spanning the entire UV/Vis/NIR region in these mineral acids reported since the 1960s. Here, using this high-resolution absorption data, provided in an open access format for the broader field, we build on prior work by Carnall and others to provide detailed optical analysis including all transition assignments. This work also includes the first reported absorption spectrum of Am(III) in aq. HBr. Characteristic Am(III) luminescence could be detected from all three samples. These are the first reports of emission from Am(III) in these acid systems, which build on prior emission reports collected from aq. HClO 4 solutions. The acquired emission spectra display anion-dependent shifting of the visible-region transitions by up to 21 nm from their predicted positions, akin to the nephelauxetic effect. The shift magnitude trends linearly according to the acid p K a and more generally according to the transition metal spectrochemical series. These ligand field effects, coupled with luminescence lifetime experiments, indicate that weak Am-X interactions persist in solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexed structured imaging of laser induced fluorescence at 10 GHz rate

The frame rate of conventional high-speed imaging devices is limited by exposure time and signal read-out time. Structured imaging is able to push the frame rate beyond the limit of the imaging device. This work demonstrates the feasibility of potential TeraHz rate structured imaging with a multiplexed structured imaging setup. In this work, a multiplexed structured image capture system was employed to image UV laser induced krypton-II emission lines at 10 GHz. The measured emission intensity of the 764 nm line over time suggests a temporal resolution of 97 ps. The temporal resolution is adjustable, and the frame rate can be further increased to the TeraHz level.

47 OTHER INSTRUMENTATION↗

Spectral features of colloidal solutions of elongated gold nanoparticles produced by laser ablation in aqueous solutions

The extinction spectra of colloidal solutions of gold nanoparticles produced by laser ablation in water and aqueous solutions of salts using two near-IR lasers with pulse durations of 200 ns and 1 ps are experimentally investigated. The extinction spectrum of the particles formed by ablation in aqueous solutions is characterised by enhanced optical density in the red and IR regions. This feature is due to the formation of elongated gold nanoparticles, as confirmed by transmission electron microscopy. The surface images of a gold target subjected to multipulse laser ablation exhibit micron and submicron structures. (nanophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing cloud motion estimation on the edge with phase correlation and optical flow

Abstract. Phase correlation (PC) is a well-known method for estimating cloud motion vectors (CMVs) from infrared and visible spectrum images. Commonly, phase shift is computed in the small blocks of the images using the fast Fourier transform. In this study, we investigate the performance and the stability of the blockwise PC method by changing the block size, the frame interval, and combinations of red, green, and blue (RGB) channels from the total sky imager (TSI) at the United States Atmospheric Radiation Measurement user facility's Southern Great Plains site. We find that shorter frame intervals, followed by larger block sizes, are responsible for stable estimates of the CMV, as suggested by the higher autocorrelations. The choice of RGB channels has a limited effect on the quality of CMVs, and the red and the grayscale images are marginally more reliable than the other combinations during rapidly evolving low-level clouds. The stability of CMVs was tested at different image resolutions with an implementation of the optimized algorithm on the Sage cyberinfrastructure test bed. We find that doubling the frame rate outperforms quadrupling the image resolution in achieving CMV stability. The correlations of CMVs with the wind data are significant in the range of 0.38–0.59 with a 95 % confidence interval, despite the uncertainties and limitations of both datasets. A comparison of the PC method with constructed data and the optical flow method suggests that the post-processing of the vector field has a significant effect on the quality of the CMV. The raindrop-contaminated images can be identified by the rotation of the TSI mirror in the motion field. The results of this study are critical to optimizing algorithms for edge-computing sensor systems.

54 ENVIRONMENTAL SCIENCES↗

Multiwavelength Observations of the Blazar VER J0521+211 during an Elevated TeV Gamma-Ray State

We report on a long-lasting, elevated gamma-ray flux state from VER J0521+211 observed by VERITAS, MAGIC, and Fermi-LAT in 2013 and 2014. The peak integral flux above 200 GeV measured with the nightly binned light curve is (8.8 ± 0.4) × 10 –7 photons m –2 s –1 , or ~37% of the Crab Nebula flux. Multiwavelength observations from X-ray, UV, and optical instruments are also presented. A moderate correlation between the X-ray and TeV gamma-ray fluxes was observed, and the X-ray spectrum appeared harder when the flux was higher. Using the gamma-ray spectrum and four models of the extragalactic background light (EBL), a conservative 95% confidence upper limit on the redshift of the source was found to be z ≤ 0.31. Unlike the gamma-ray and X-ray bands, the optical flux did not increase significantly during the studied period compared to the archival low-state flux. The spectral variability from optical to X-ray bands suggests that the synchrotron peak of the spectral energy distribution (SED) may become broader during flaring states, which can be adequately described with a one-zone synchrotron self-Compton model varying the high-energy end of the underlying particle spectrum. The synchrotron peak frequency of the SED and the radio morphology of the jet from the MOJAVE program are consistent with the source being an intermediate-frequency-peaked BL Lac object.

79 ASTRONOMY AND ASTROPHYSICS↗

D-Egg: a dual PMT optical module for IceCube

The D-Egg, an acronym for "Dual optical sensors in an Ellipsoid Glass for Gen2," is one of the optical modules designed for future extensions of the IceCube experiment at the South Pole. The D-Egg has an elongated-sphere shape to maximize the photon-sensitive effective area while maintaining a narrow diameter to reduce the cost and the time needed for drilling of the deployment holes in the glacial ice for the optical modules at depths up to 2700 m. The D-Egg design is utilized for the IceCube Upgrade, the next stage of the IceCube project also known as IceCube-Gen2 Phase 1, where nearly half of the optical sensors to be deployed are D-Eggs. With two 8-inch high-quantum efficiency photomultiplier tubes (PMTs) per module, D-Eggs offer an increased effective area while retaining the successful design of the IceCube digital optical module (DOM). The convolution of the wavelength-dependent effective area and the Cherenkov emission spectrum provides an effective photodetection sensitivity that is 2.8 times larger than that of IceCube DOMs. The signal of each of the two PMTs is digitized using ultra-low-power 14-bit analog-to-digital converters with a sampling frequency of 240 MSPS, enabling a flexible event triggering, as well as seamless and lossless event recording of single-photon signals to multi-photons exceeding 200 photoelectrons within 10 ns. Mass production of D-Eggs has been completed, with 277 out of the 310 D-Eggs produced to be used in the IceCube Upgrade. In this paper, we report the design of the D-Eggs, as well as the sensitivity and the single to multi-photon detection performance of mass-produced D-Eggs measured in a laboratory using the built-in data acquisition system in each D-Egg optical sensor module.

47 OTHER INSTRUMENTATION↗

Persistent Room-Temperature Photodarkening in Cu-Doped β - Ga 2 O 3

β–Ga 2 O 3 is an ultrawide band gap semiconductor with emerging applications in power electronics. Here, the introduction of acceptor dopants yields semi-insulating substrates necessary for thin-film devices. In the present work, exposure of Cu-doped β–Ga 2 O 3 to UV light > 4 eV is shown to cause large, persistent photo-induced darkening at room temperature. Electron paramagnetic resonance spectroscopy indicates that light exposure converts Cu 2+ to Cu 3+ , a rare oxidation state that is responsible for the optical absorption. The photodarkening is accompanied by the appearance of O–H vibrational modes in the infrared spectrum. Hybrid function calculations show that Cu acceptors can favorably complex with hydrogen donors incorporated as interstitial (Hi) or substitutional (HO) defects. When Cu Ga –HO complexes absorb light, hydrogen is released, contributing to the observed Cu 3+ species and O–H modes.

36 MATERIALS SCIENCE↗

Machine Straightness Error Measurement Based on Optical Fiber Fabry–Pérot Interferometer Monitoring Technique

Abstract In this research, we propose an Error Separation Technique (EST) based on optical fiber sensors for on-machine straightness error measurement. Two fiber optic Fabry–Pérot interferometers have been developed serving as two displacement sensors. The displacement distance is computed according to the reflected spectrum from interferometers, which can achieve a sub-micrometer resolution. The two-point method has been employed to separate the straightness error of the slides and the profile error of a fine-polished standard block. The spacing distance between two interferometers is determined by the diameter of optical fibers so that the EST's resolution has the potential to reach the sub-millimeter scale. In the experiment, the straightness error has been measured on a commercially available computer numerical control machine tool, and the measurement has been conducted on its x-axis. The spacing distance between two optical fiber sensors is 1.5 mm which equals the EST's resolution along the machine tool's x-axis. The separated profile error of the measured standard block is around 30 µm which has been verified by a high precision Coordinate Measurement Machine (CMM). The magnitude of the separated straightness error is around 40 µm. This technique is flexible and simple to be conducted, which can contribute to the micro-machine tool calibration and other straightness error applications.

Engineering↗

Spin-Forbidden Excitations in the Magneto-optical Spectra of CrI 3 Tuned by Covalency

Spin-forbidden (Δ⁢𝑆 ≠0) multiplet excitations and their coupling to magnetic properties are of increasing importance for magneto-optical studies of correlated materials. Nonetheless, the mechanisms for optically brightening these transitions and their generality remain poorly understood. Here, we report magnetic circular dichroism (MCD) spectroscopy on the van der Waals ferromagnet (FM) CrI 3 . Previously unreported spin-forbidden (Δ⁢𝑆 =1) 4 𝐴 2⁢g → 2 𝐸 g / 2 𝑇 1⁢g Cr 3+ 𝑑⁢𝑑 excitations are observed near the ligand-to-metal charge-transfer excitation threshold. The assignment of these excitations and their Cr 3+ multiplet character is established through complementary Cr 𝐿 3 -edge resonant inelastic x-ray scattering measurements along with charge-transfer multiplet calculations and chemical trends in the chromium trihalide series (Cr⁢𝑋 3 , 𝑋 = Cl, Br, I). We utilize the high sensitivity of MCD spectroscopy to study the thickness-dependent optical response. The spin-forbidden excitations remain robust down to the monolayer limit, and we observe a significant magnetic-field dependence of the MCD spectrum across the antiferromagnetic-to-FM transition in few-layer samples. We preliminarily attribute this behavior to changes in the metal-ligand covalency with magnetic state. Our results clarify the magneto-optical response of CrI 3 and identify covalency as a central mechanism for the brightening and field tunability of spin-forbidden multiplet excitations.

36 MATERIALS SCIENCE↗

A series of Rb 4 Ln 2 (P 2 S 6 )(PS 4 ) 2 (Ln = La, Ce, Pr, Nd, Sm, Gd) rare earth thiophosphates with two distinct thiophosphate units [P V S 4 ] 3- and [P IV 2 S 6 ] 4-

A series of rubidium rare earth thiophosphates with the formula Rb 4 Ln 2 (P 2 S 6 )(PS 4 ) 2 (Ln = La, Ce, Pr, Nd, Sm, and Gd) were synthesized using the high temperature molten flux crystal growth method utilizing a RbBr flux. Single crystals of all title compounds, as well as phase pure powders of the La-, Ce-, and Sm-containing compositions, were obtained. Single crystals of the title compounds were characterized by single crystal and powder X-ray diffraction for structure and phase identification. Rb 4 Ln 2 (P 2 S 6 )(PS 4 ) 2 crystallizes in the monoclinic crystal system adopting the P2 1 /n space group for the large rare earths (Ln = La, Ce, Pr) and the C2/c space group for the smaller rare earths (Ln = Nd, Sm, Gd). This Rb 4 Ln 2 (P 2 S 6 )(PS 4 ) 2 series is a rare example of thiophosphates containing both tetrahedral [P V S 4 ] 3– and dimeric [P IV 2 S 6 ] 4– thiophosphate units that, in this structural family, link corrugated rare earth sulfide chains into sheets. Here, the band gaps of the materials were determined from UV–Vis data and the fluorescence spectrum of Rb 4 Ce 2 (P 2 S 6 )(PS 4 ) 2 was collected. Optical band gaps were estimated to be 2.9 and 2.4 for the Nd and Sm analogues, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

XMM-Newton and SRG/eROSITA observations of the isolated neutron star candidate 4XMM J 022141.5-735632

We report the results of follow-up investigations of a possible new thermally emitting isolated neutron star (INS), 4XMM J022141.5-735632, using observations from XMM-Newton and Spectrum Roentgen Gamma (SRG) eROSITA. The analysis is complemented by Legacy Survey imaging in the optical and near-infrared wavelengths. The X-ray source, the first to be targeted by XMM-Newton in an effort to identify new INS candidates from the fourth generation of the XMM-Newton serendipitous source catalogue Data Release 9 (4XMM-DR9), shows a remarkably soft energy distribution and a lack of catalogued counterparts; the very high X-ray-to-optical flux ratio virtually excludes any other identification than an INS. Within current observational limits, no significant flux variation or change of spectral state is registered over nearly ten years. Future dedicated observations, particularly to search for pulsations, are crucial to shed further light on the nature of the X-ray source and relations to other Galactic neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗