Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Acceptability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Electro- and photoproduction of muon pairs with $$\mu $$CLAS12: double deeply virtual compton scattering, timelike compton scattering, and $$J/\psi $$ production

The CEBAF Large Acceptance Spectrometer for operation at 12 GeV (CLAS12) at the Thomas Jefferson National Accelerator Facility has played a central role in advancing the understanding of nucleon and nuclear structure. As increasingly precise data become available, new physics opportunities emerge that extend beyond the current capabilities of CLAS12. In this article, a program to explore the quark and gluon structure of the nucleon through di-muon electro- and photoproduction is presented. Its primary focus is the measurement of beam-spin asymmetries in Double Deeply Virtual Compton Scattering, . By independently varying the incoming and outgoing photon virtualities and momentum transfer, the DDVCS measurement provides access to the Generalized Parton Distributions over their full three-dimensional phase space, extending beyond the kinematic constraints of Deeply Virtual Compton Scattering and Timelike Compton Scattering. In addition, the large acceptance and high luminosity of the CLAS12 experiment will enable precision measurements of near-threshold production and high-statistics studies of Timelike Compton Scattering.

Alvarado, J. S.↗

Helicopter Pilot Evaluations of the Airborne Collision Avoidance System Xr in a High-Fidelity Motion Simulation

New aircraft and aerial Urban Air Mobility operations require updated technologies to maintain vehicle separation during flight. Specifically, higher-density airspace will need more than traditional air traffic control to keep vehicles well clear of each other and avoid Near Midair Collisions. In response, the Federal Aviation Administration is currently developing the Airborne Collision Avoidance System X (ACAS X) for next-generation air traffic deconfliction, which provides caution-level and warning-level alerts in response to multiple aircraft types. This study recruited six helicopter pilots to fly an electric vertical takeoff and landing vehicle model in simulated operations under Visual Flight Rules (VFR). Flights were accomplished using the high-fidelity Vertical Motion Simulator at the NASA Ames Research Center. Participants controlled the vehicle using two side inceptors and foot rudders. The rotorcraft variant of ACAS X (ACAS Xr) was provided for alerting and guidance during traffic conflicts. Pilots used this system while giving feedback to the researchers through questionnaires, debriefs, and other discussions. Variables of interest to the study were phases of flight (i.e., Cruise, Hover, and Approach) and ACAS Xr configurations: The Collision Avoidance System configuration behaves similarly to current commercial traffic systems used for tactical deconfliction in crewed vehicles, and the Detect and Avoid configuration was developed to provide extra, corrective-level guidance for unmanned aircraft systems. Results showed that pilots found the alerting and guidance from ACAS Xr useful, effective, and acceptable for VFR operations. Certain elements, like speed guidance and text banners, were found to be of no use to the pilots. Hover and Approach scenarios were considered the most difficult for ACAS Xr alerting. Reasons for this difficulty were partially due to learning interference (i.e., overcoming previously learned behavior) and partially due to the vehicle model (i.e., NASA’s Lift Plus Cruise design). Still, alerting-based confounds reveal the need for more development for ACAS Xr during these Hover and Approach flight phases. Study caveats and future projects are discussed.

air taxis↗

Helicopter Pilot Evaluations of the Airborne Collision Avoidance System Xr in a High-Fidelity Motion Simulation

New aircraft and aerial Urban Air Mobility operations require updated technologies to maintain vehicle separation during flight. Specifically, higher-density airspace will need more than traditional air traffic control to keep vehicles well clear of each other and avoid Near Midair Collisions. In response, the Federal Aviation Administration is currently developing the Airborne Collision Avoidance System X (ACAS X) for next-generation air traffic deconfliction, which provides caution-level and warning-level alerts in response to multiple aircraft types. This study recruited six helicopter pilots to fly an electric vertical takeoff and landing vehicle model in simulated operations under Visual Flight Rules (VFR). Flights were accomplished using the high-fidelity Vertical Motion Simulator at the NASA Ames Research Center. Participants controlled the vehicle using two side inceptors and foot rudders. The rotorcraft variant of ACAS X (ACAS Xr) was provided for alerting and guidance during traffic conflicts. Pilots used this system while giving feedback to the researchers through questionnaires, debriefs, and other discussions. Variables of interest to the study were phases of flight (i.e., Cruise, Hover, and Approach) and ACAS Xr configurations: The Collision Avoidance System configuration behaves similarly to current commercial traffic systems used for tactical deconfliction in crewed vehicles, and the Detect and Avoid configuration was developed to provide extra, corrective-level guidance for unmanned aircraft systems. Results showed that pilots found the alerting and guidance from ACAS Xr useful, effective, and acceptable for VFR operations. Certain elements, like speed guidance and text banners, were found to be of no use to the pilots. Hover and Approach scenarios were considered the most difficult for ACAS Xr alerting. Reasons for this difficulty were partially due to learning interference (i.e., overcoming previously learned behavior) and partially due to the vehicle model (i.e., NASA’s Lift Plus Cruise design). Still, alerting-based confounds reveal the need for more development for ACAS Xr during these Hover and Approach flight phases. Study caveats and future projects are discussed.

air taxis↗

Characterization of Aerodynamic Performance of Boundary-Layer-Ingesting Inlet Under Crosswind

NASA has been studying future transport concepts, envisioned to be technically realizable in the timeframe of 2020-2030, to meet environmental and performance goals. One concept receiving considerable interest involves a propulsion system embedded into a hybrid wing-body aircraft. While offering significant advantages in fuel savings and noise reduction by this concept, there are several technical challenges that are not encountered in the current fleet and must be overcome so as to deliver target performance and operability. One of these challenges is associated with an inlet system that ingests a significantly thick boundary layer, developing along the wing-body surface, into a serpentine diffuser before the flow meeting fan blades. The flow is subject to considerable total pressure loss and distorted at the fan face, much more significantly than in the inlet system of conventional aircraft. In our previous studies [1, 2], we have shown that through innovative design changes on the airframe surface, it is possible to simultaneously increase total pressure recovery and decrease distortion in the flow, without resorting to conventional penalty-ridden flow control concepts, such as vortex generator or boundary layer bleeding/suction. In the current study, we are interested in understanding the following issues: how the embedded propulsion system performs under a crosswind condition by studying in detail the flow characteristics of two inlets, the baseline and another optimized previously under the cruise condition. With the insight, it is hoped that it can help in the follow-on study by devising effective strategies to minimize flow distortion arising from the integration of an embedded-engine system into an airframe to the level acceptable to the operation and fuel consumption before 2030. To achieve these demanding goals, non-conventional concepts are called for; but technology gap is too big that it requires evolutionary approach by focusing various concepts and technologies needed in the next three generations of aircraft, respectively named as N+1, N+2, and N+3. Noticeably, considerable reduction in each category of 1 is required in N+2 (relative to Boeing 777-200 and GE90 engines) and N+3 (relative to Boeing 737-800 and CFM56-7B engines). In this study, concepts for N+2 is our interest. A concept that has potential to achieve these metrics and has been under intensive study is the hybrid wing body (HWB) airframe with a tightly integrated propulsion system, see Fig. 1. The inlet is non-circular at the entrance and the entering flow, no longer uniform or free of disturbances, and is now carrying with it a boundary layer developing along the fuselage; the inlet is thus known as boundary-layer-ingesting (BLI) inlet.

Liou, Meng-Sing↗

Unique Systems Analysis Task 7, Advanced Subsonic Technologies Evaluation Analysis

To retain a preeminent U.S. position in the aircraft industry, aircraft passenger mile costs must be reduced while at the same time, meeting anticipated more stringent environmental regulations. A significant portion of these improvements will come from the propulsion system. A technology evaluation and system analysis was accomplished under this task, including areas such as aerodynamics and materials and improved methods for obtaining low noise and emissions. Previous subsonic evaluation analyses have identified key technologies in selected components for propulsion systems for year 2015 and beyond. Based on the current economic and competitive environment, it is clear that studies with nearer turn focus that have a direct impact on the propulsion industry s next generation product are required. This study will emphasize the year 2005 entry into service time period. The objective of this study was to determine which technologies and materials offer the greatest opportunities for improving propulsion systems. The goals are twofold. The first goal is to determine an acceptable compromise between the thermodynamic operating conditions for A) best performance, and B) acceptable noise and chemical emissions. The second goal is the evaluation of performance, weight and cost of advanced materials and concepts on the direct operating cost of an advanced regional transport of comparable technology level.

Eisenberg, Joseph D.↗

Use of Data Comm by Flight Crew in High-Density Terminal Areas

This paper describes a collaborative FAA and NASA experiment using 22 commercial airline pilots to determine the effect of using Datalink Communication (Data Comm) to issue messages in busy, terminal area operations. Four conditions were defined that span current day to future flight deck equipage levels (voice communication only, Data Comm only, Data Comm with Moving Map Display, Data Comm with Moving Map displaying taxi route), and each condition was used to create an arrival and a departure scenario at the Boston Logan Airport. These eight scenarios were repeated twice for a total of 16 scenarios for each of the eleven crews. Quantitative data was collected on subject reaction time and eye tracking information. Questionnaires collected subjective feedback on workload and acceptability to the flight crew for using Data Comm in a busy terminal area. 95% of the Data Comm messages were responded to by the flight crew within one minute; however, post experiment debrief comments revealed almost unanimous consensus that two minutes was a reasonable expectation for crew response. Eye tracking data indicated an insignificant decrease in head-up time for the Pilot Flying when Data Comm was introduced; however, the Pilot Monitoring had significantly less head-up time. Data Comm workload was rated as operationally acceptable by both crew members in all conditions in flight at any altitude above the Final Approach Fix in terms of response time and workload. Results also indicate the use of Data Comm during surface operations was acceptable, the exception being the simultaneous use of voice, Data Comm, and audio chime required for an aircraft to cross an active runway. Many crews reported they believed Data Comm messages would be acceptable after the Final Approach Fix or to cross a runway if the message was not accompanied by a chime and there was not a requirement to immediately respond to the uplink message.

Baxley, Brian T.↗

Core design and performance of the Westinghouse lead fast reactor with UO 2 and MOX configurations

For this work, Westinghouse partnered with Argonne National Laboratory to design, model and optimize UO 2 - and MOX-fueled core designs for a medium size (950 MWt) Lead Fast Reactor that was pursued by Westinghouse. Using Argonne’s suite of reactor analysis codes together with Westinghouse fuel cost economic models, thousands of candidate cores were considered to achieve the economics-optimized cores presented in this paper. This optimization process considered detailed reactor physics, fuel performance, transient performance, and fuel economics models. The reactor performance of the resulting optimized UO 2 - and MOX-fueled core designs are described and compared in this paper. Both cores show fuel performance and transient behavior that is considered acceptable for the optimization presented herein, while further testing campaigns on material performance in high-temperature liquid lead will be required to confirm acceptability at the operating conditions chosen. A multi-batch strategy was selected for the UO 2 core for best fuel utilization with minimum fuel inventory costs. A single-batch fuel management was instead selected for the MOX core to maximize cycle length and minimize the impact of the longer refueling outage resulting from the higher decay heat of the discharged MOX fuel relative to the discharged UO 2 fuel, requiring a longer cooling time before dry-lift of discharged fuel could take place.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis and design of fast flow liquid Li divertor for fusion nuclear science facility (FNSF) using coupled plasma boundary and LM MHD/heat transfer codes *

The SOLPS-ITER code is utilized to analyze the boundary plasma associated with a fast-flow lithium (Li) divertor configuration in the fusion nuclear science facility (FNSF) tokamak and identify operational regimes with acceptable divertor and core conditions. Plasma transport from the SOLPS-ITER code has been coupled with a liquid metal (LM) MHD/heat transfer code to model a Li open-surface divertor design and assess its impact on the scrape-off-layer (SOL) and core plasma performance. Simulations with only Neon (Ne) impurity seeding have been conducted to evaluate its impact on meeting FNSF design demands for the divertor and upstream plasma parameters. Simulation results indicate that Ne seeding significantly mitigates divertor heat flux but potentially reduces both upstream electron and main ion density due to fuel dilution. The combined application of Ne seeding and deuterium (D 2 ) puffing is required to satisfy the FNSF design requirements on upstream density ($n^{OMP}_{e,sep}$~1× 10 20 m -3 ) and divertor energy flux ($q^{Odiv}_{\bot,max}$<10 MW m -2 ). D 2 puffing plays a role in counteracting upstream density drops and augmenting energy and momentum losses through atomic and molecular processes. The inlet Li flow velocity is systematically varied across a wide range to identify acceptable flows and corresponding LM surface temperatures. This comprehensive analysis identifies the acceptable Li flow parameters, LM surface temperature, and emitted Li fluxes necessary to meet the major design constraints. The emitted Li fluxes exhibit minimal impact on the main plasma at surface temperatures up to approximately ~525 °C, corresponding emitted Li fluxes of up to φ Li ~2X10 23 atoms s -1 . Uncertainties in the Li emission processes from the surface are also investigated, primarily influencing Li loss in the lower surface temperature range (<525 °C), with simulation results indicating a minor impact on the divertor and upstream plasma. Conversely, evaporation predominantly drives the Li loss processes at higher surface temperature ranges (>525 °C), contaminating both the divertor and upstream plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Novel Secondary Frequency Regulation with Optimal Priority Selection of AGC Contributions

Automatic generation control (AGC) is used to maintain acceptable frequencies during operation owing to fluctuations in load and variable resources. In conventional industry applications, the AGC signal is allocated to each generator according to the predispatched frequency regulation capacity or the order of economic efficiency. However, with the increasing integration of inverter-based resources (IBRs), the retirement of conventional synchronous generators (SGs) has posed new challenges to frequency control schemes because fewer of them are optional for AGC regulation. In this paper, we propose a novel model predictive control (MPC)-based frequency regulation model to reduce control cost and ensure stability, by considering different critical dynamic factors when optimally selecting the AGC units. The proposed control model – developed in a general form – comprehensively embeds characteristics such as generator ramping rates, reserve capacity, and operation cost. The model predictive control–based two-timescale AGC scheme enhances the capability of immunizing the power disturbance from types of resources by coordinating the control signals between faster IBRs and slower SGs. The case study’s proposed model is verified to be effective in synergistically enforcing different dynamic properties of AGC units into the frequency regulation scheme.

Jiang, Sufan [The University of North Carolina at ↗

Electrolyte Takeover Strategy for Performance Recovery in Polysulfide-Permanganate Flow Batteries

The abundance of active material precursors for a polysulfide-permanganate flow battery makes it a compelling chemistry for large-scale, and potentially long-duration (>10 h), grid electricity storage. Precipitation, arising from either reactant crossover or electrolyte side reactions, decrease cell efficiencies during charge/discharge cycling. Regardless of the abundance and low cost of active materials, a system without high cyclability cannot meet grid electricity storage economic targets for applications that cycle regularly. Precipitated species can be removed, and reactor efficiency performance restored, by using an electrolyte takeover process, or ETP. Two ETP methods are investigated. One ETP uses the negative electrolyte, an alkaline polysulfide (pS) solution, as takeover solution, and another uses dilute acidic peroxide (DAP) as the takeover solution. Both ETPs maintain functional cell operation within an acceptable performance range over >1000 h and >200 cycles, a duration over which cells that do not undergo ETPs clog and fail. The DAP ETP proves especially effective and limits irrecoverable voltage efficiency fade below 0.02%/cycle. These ETPs, either individually, or in combination, can enable the requisite cyclability for practical polysulfide-permanganate flow battery systems.

25 ENERGY STORAGE↗

Mixed Waste Landfill Annual Long-Term Monitoring & Maintenance Report (Apr 2015-Mar 2016)

Sandia National Laboratories (SNL) is a multi-purpose engineering and science laboratory owned by the U.S. Department of Energy (DOE)/National Nuclear Security Administration. SNL is managed and operated by Sandia Corporation (Sandia), a wholly-owned subsidiary of Lockheed Martin Corporation. Sandia National Laboratories, New Mexico (SNL/NM) is located within the boundaries of Kirtland Air Force Base (KAFB), southeast of the City of Albuquerque in Bernalillo County, New Mexico. The Mixed Waste Landfill (MWL) is located 4 miles south of SNL/NM central facilities and 5 miles southeast of Albuquerque International Sunport, in the north-central portion of Technical Area (TA)-III. The MWL disposal area comprises 2.6 acres. During operations, the MWL accepted containerized and other low-level radioactive waste and minor amounts of mixed waste from SNL/NM research facilities and off-site DOE and U.S. Department of Defense generators from March 1959 to December 1988. More specific information regarding the MWL inventory and past disposal practices is presented in the MWL Phase 2 RCRA Facility Investigation Report (Peace et al. September 2002) and the extensive MWL Administrative Record.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmental Validation of Materials and Design Concepts to Enable Operational Flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility will need to be evaluated for resilience to frequent start-ups, meeting major and rapid load changes, and providing frequency control duties. Our research objective was to evaluate and improve flexibility of existing power plants by improving and redesigning components and defining new operational strategies, with acceptable impacts on component life, efficiency and emissions.

20 FOSSIL-FUELED POWER PLANTS↗

Extravehicular mobility unit thermal simulator

The analytical methods, thermal model, and user's instructions for the SIM bay extravehicular mobility unit (EMU) routine are presented. This digital computer program was developed for detailed thermal performance predictions of the crewman performing a command module extravehicular activity during transearth coast. It accounts for conductive, convective, and radiative heat transfer as well as fluid flow and associated flow control components. The program is a derivative of the Apollo lunar surface EMU digital simulator. It has the operational flexibility to accept card or magnetic tape for both the input data and program logic. Output can be tabular and/or plotted and the mission simulation can be stopped and restarted at the discretion of the user. The program was developed for the NASA-JSC Univac 1108 computer system and several of the capabilities represent utilization of unique features of that system. Analytical methods used in the computer routine are based on finite difference approximations to differential heat and mass balance equations which account for temperature or time dependent thermo-physical properties.

Hixon, C. W.↗

The cryogenic wind tunnel for high Reynolds number testing

Experiments performed at the NASA Langley Research Center in a cryogenic low-speed continuous-flow tunnel and in a cryogenic transonic continuous-flow pressure tunnel have demonstrated the predicted changes in Reynolds number, drive power, and fan speed with temperature, while operating with nitrogen as the test gas. The experiments have also demonstrated that cooling to cryogenic temperatures by spraying liquid nitrogen directly into the tunnel circuit is practical and that tunnel temperature can be controlled within very close limits. Whereas most types of wind tunnel could operate with advantage at cryogenic temperatures, the continuous-flow fan-driven tunnel is particularly well suited to take full advantage of operating at these temperatures. A continuous-flow fan-driven cryogenic tunnel to satisfy current requirements for test Reynolds number can be constructed and operated using existing techniques. Both capital and operating costs appear acceptable.

Kilgore, R. A.↗

Delayed flap approach procedures for noise abatement and fuel conservation

The NASA/Ames Research Center is currently investigating the delayed flap approach during which pilot actions are determined and prescribed by an onboard digital computer. The onboard digital computer determines the proper timing for the deployment of the landing gear and flaps based on the existing winds and airplane gross weight. Advisory commands are displayed to the pilot. The approach is flown along the conventional ILS glide slope but is initiated at a higher airspeed and in a clean aircraft configuration that allows for low thrust and results in reduced noise and fuel consumption. Topics discussed include operational procedures, pilot acceptability of these procedures, and fuel/noise benefits resulting from flight tests and simulation.

Edwards, F. G.↗

Experimental Evaluation of a Low Emissions High Performance Duct Burner for Variable Cycle Engines (VCE)

An evaluation was conducted with a three stage Vorbix duct burner to determine the performance and emissions characteristics of the concept and to refine the configuration to provide acceptable durability and operational characteristics for its use in the variable cycle engine (VCE) testbed program. The tests were conducted at representative takeoff, transonic climb, and supersonic cruise inlet conditions for the VSCE-502B study engine. The test stand, the emissions sampling and analysis equipment, and the supporting flow visualization rigs are described. The performance parameters including the fuel-air ratio, the combustion efficiency/exit temperature, thrust efficiency, and gaseous emissions calculations are defined. The test procedures are reviewed and the results are discussed.

Lohmann, R. P.↗

Solar heating and cooling demonstration project at the Florida solar energy center

The retrofitted solar heating and cooling system installed at the Florida Solar Energy Center is described. The system was designed to supply approximately 70 percent of the annual cooling and 100 percent of the heating load. The project provides unique high temperature, nonimaging, nontracking, evacuated tube collectors. The design of the system was kept simple and employs five hydronic loops. They are energy collection, chilled water production, space cooling, space heating and energy rejection. Information is provided on the system's acceptance test results operation, controls, hardware and installation, including detailed drawings.

Source record↗

Solar heating system installed at Stamford, Connecticut

The solar heating system installed at the Lutz-Sotire Partnership Executive East Office Building, Stamford, Connecticut is described. The Executive East Office Building is of moderate size with 25,000 sq ft of heated space in 2 1/2 stories. The solar system was designed to provide approximately 50 percent of the heating requirements. The system components are described. Appended data includes: the system design acceptance test, the operation and maintenance manual, and as-built drawings and photographs.

Source record↗