Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical plasma measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017) (and subsequently titled) Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020) (Final Technical Report)

This is the Final Technical Report for the DoE Measurement Innovation (previously Diagnostic Development) grant DE-SC0006077 titled HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017), and subsequently titled Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 May 2011–17 July 2020. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that will improve understanding of transport, magnetic equilibrium, and electric fields in magnetically confined plasmas. We have developed novel hardware and advanced techniques to expand beam-based diagnostic capabilities, and extend measurements to new operating regimes. Some have been realized using a Heavy Ion Beam Probe (HIBP) having traditional features, while other applications have joined our innovations with subsets of advantageous HIBP features. This work has established smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key Measurement Innovations include: Computer Models and Simulations of HIBP Applications-Computer modeling and simulating of HIBP applications is central to predicting interaction of beam particles with plasmas, designing diagnostic systems, and anticipating measurement characteristics. We have extended the capability and improved measurement fidelity of the HIBP diagnostic on the Madison Symmetric Torus (MST) reversed field pinch (RFP); simulated feasibility of HIBP operation in the Helically Symmetric eXperiment (HSX) optimized stellarator; and investigated the plausibility of HIBP measurements in the ASDEX Upgrade tokamak. We have also developed a new technique that uses ion optics to model a finite phase-space beam. It yields more realistic (than traditional method) estimates of sample volume characteristics, which influence measurement resolution and sensitivity. Extension of Diagnostic Capabilities and Measurements on the MST RFP-Capabilities have been extended using the first and only HIBP installation on an RFP. Challenges associated with operation of the diagnostic on MST include the three-dimensional nature of particle trajectories, temporal topology and amplitude changes in the plasma equilibrium, and strong particle and radiative emission from the plasma. We have addressed these challenges through development of detailed and higher precision diagnostic simulations, calibrated subtraction of noise to resolve secondary ion signals, and implementation of hardware that enables higher fidelity measurement of plasma fluctuations. Development of New Hardware and Measurement Techniques - We have advanced beam-based measurement capabilities via development of new detectors and techniques to determine the poloidal magnetic flux ψ in the plasma, and enable placement of detectors close to the plasma and thus allow a smaller and less expensive diagnostic. We have demonstrated measurement of ψ, an ability that was made possible by development of highly effective noise reduction techniques. We also modeled the effect of non-ideal and instrumentation effects by developing a virtual (simulated) diagnostic. Application of beam-based diagnostics on various devices and multiple magnetic configurations (e.g. stellarator, tokamak, and reversed field pinch) enables investigation of critical physics issues and measurements resulting in the broad parameter space data needed to test and validate theory & modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatio-temporal ion temperature and velocity measurements in a Z pinch using fast-framing spectroscopy

Ion Doppler spectroscopy (IDS) is a diagnostic technique that measures plasma ion temperature and velocity without perturbing the plasma with a physical probe. The ZaP-HD Flow Z-Pinch Experiment at the University of Washington uses this technique to resolve radial temperature and velocity profiles of a Z-pinch plasma. The pinch lifetime is approximately 100 ms, therefore diagnostics capable of sub-microsecond resolution are required to measure the evolution of temperature and velocity profiles. The previous IDS diagnostic system was only capable of collecting a single measurement during a plasma pulse. Here, an improved system has been developed to measure radially-resolved ion temperature and velocity for the entire Z-pinch lifetime. A Kirana 05M ultra-fast framing camera and SIL ultraviolet intensifier are used to record up to 100 spectra per plasma pulse. The temperature is computed from Doppler broadening of the carbon-III (229.687 nm) impurity ion radiation and the velocity from the Doppler shift of carbon-III. Measurements are able to resolve the evolution of the ion temperature and velocity over the course of a plasma pulse. The diagnostic has significantly reduced the number of pulses required and provides a more coherent measurement of plasma dynamics than the previous system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A transmitted-beam diagnostic for the wavelength-tunable UV drive beam on OMEGA

A transmitted-beam diagnostic (P9TBD) was developed as part of a new experimental platform used to study laser–plasma interactions on OMEGA. Located in the opposing port to the wavelength-tunable (350 nm to 353 nm) UV drive beam, the P9TBD characterizes the beam after it propagates through an undersense plasma. The instrument consists of a large-aperture window that allows light to exit the target chamber and project onto a thin sheet of semi-transparent diffuser material. Light transmitted through the diffuser is recorded using a time-integrated camera and a fiber-optically coupled streaked spectrometer, providing measurements of the energy, power, fluence, polarization, and spectrum of the transmitted beam. Here, the diagnostic enables direct observation of a variety of cross-beam energy transfer phenomena, such as wavelength detuning, polarization effects, and gain saturation.

47 OTHER INSTRUMENTATION↗

Toward direct spatial and intensity characterization of ultra-high-intensity laser pulses using ponderomotive scattering of free electrons

Spatial distributions of electrons ionized and scattered from ultra-low-pressure gases are proposed and experimentally demonstrated as a method to directly measure the intensity of an ultra-high-intensity laser pulse. Analytic models relating the peak scattered electron energy to the peak laser intensity are derived and compared to paraxial Runge–Kutta simulations highlighting two models suitable for describing electrons scattered from weakly paraxial beams (f#>5) for intensities in the range of 1018−1021 W cm−2. Scattering energies are shown to be dependent on gas species, emphasizing the need for specific gases for given intensity ranges. Direct measurements of the laser intensity at full power of two laser systems are demonstrated, both showing a good agreement between indirect methods of intensity measurement and the proposed method. One experiment exhibited the role of spatial aberrations in the scattered electron distribution, motivating a qualitative study on the effect. We propose the use of convolutional neural networks as a method for extracting quantitative information on the spatial structure of the laser at full power. We believe the presented technique to be a powerful tool that can be immediately implemented in many high-power laser facilities worldwide.

47 OTHER INSTRUMENTATION↗

Observation of subcritical shocks in a collisional laboratory plasma: scale dependence near the resistive length

We present a study of subcritical shocks in a highly collisional laboratory plasma with a dynamically significant magnetic field. Shocks were produced by placing cylindrical obstacles into the supermagnetosonic ( $M_{{\rm MS}} \sim 1.9$ ) outflow from an inverse wire array z-pinch at the MAGPIE pulsed power facility ( $n_{e} \sim 8.5 \times 10^{17}\,{\rm cm}^{-3}$ , $v \sim 45\,{\rm km}\,{\rm s}^{-1}$ ). We demonstrate the existence of subcritical shocks in this regime and find that secondary stagnation shocks form in the downstream which we infer from interferometry and optical Thomson scattering measurements are hydrodynamic in nature. The subcritical shock width is found to be approximately equal to the resistive diffusion length and we demonstrate the absence of a jump in hydrodynamic parameters. Temperature measurements by collective optical Thomson scattering showed little temperature change across the subcritical shock ( ${<}10\,\%$ of the ion kinetic energy) which is consistent with a balance between adiabatic and Ohmic heating and radiative cooling. We demonstrate the absence of subcritical shocks when the obstacle diameter is less than the resistive diffusion length due to decoupling of the magnetic field from the plasma. These findings are supported by magnetohydrodynamic simulations using the Gorgon and AstroBEAR codes and discrepancies between the simulations and experiment are discussed.

Physics↗

Foundations of machine learning for low-temperature plasmas: methods and case studies

Abstract Machine learning (ML) and artificial intelligence have proven to be an invaluable tool in tackling a vast array of scientific, engineering, and societal problems. The main drivers behind the recent proliferation of ML in practically all aspects of science and technology can be attributed to: (a) improved data acquisition and inexpensive data storage; (b) exponential growth in computing power; and (c) availability of open-source software and resources that have made the use of state-of-the-art ML algorithms widely accessible. The impact of ML on the field of low-temperature plasmas (LTPs) could be particularly significant in the emerging applications that involve plasma treatment of complex interfaces in areas ranging from the manufacture of microelectronics and processing of quantum materials, to the LTP-driven electrification of the chemical industry, and to medicine and biotechnology. This is primarily due to the complex and poorly-understood nature of the plasma-surface interactions in these applications that pose unique challenges to the modeling, diagnostics, and predictive control of LTPs. As the use of ML is becoming more prevalent, it is increasingly paramount for the LTP community to be able to critically analyze and assess the concepts and techniques behind data-driven approaches. To this end, the goal of this paper is to provide a tutorial overview of some of the widely-used ML methods that can be useful, amongst others, for discovering and correlating patterns in the data that may be otherwise impractical to decipher by human intuition alone, for learning multivariable nonlinear data-driven prediction models that are capable of describing the complex behavior of plasma interacting with interfaces, and for guiding the design of experiments to explore the parameter space of plasma-assisted processes in a systematic and resource-efficient manner. We illustrate the utility of various supervised, unsupervised and active learning methods using LTP datasets consisting of commonly-available, information-rich measurements (e.g. optical emission spectra, current–voltage characteristics, scanning electron microscope images, infrared surface temperature measurements, Fourier transform infrared spectra). All the ML demonstrations presented in this paper are carried out using open-source software; the datasets and codes are made publicly available. The FAIR guiding principles for scientific data management and stewardship can accelerate the adoption and development of ML in the LTP community.

Physics↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

Optical diagnostic design for measuring the radiation front with a mid-leg pumped divertor on DIII-D

The design of an optical diagnostic system to localize the radiation front in a mid-leg pumped divertor configuration on DIII-D is presented. Divertor detachment is a key mechanism for handling power exhaust in tokamaks, and mid-leg pumping offers a promising approach to radiatively dissipate power while maintaining acceptable core performance. To predict the location of the radiation front and design a spectroscopic diagnostic to measure its position, a database of SOLPS-ITER simulations across a range of input powers and gas puffing rates representative of DIII-D operation was employed. These simulations provide self-consistent plasma backgrounds for a Cherab-Raysect synthetic diagnostic framework, which incorporates detailed tokamak geometry and physically accurate ray-tracing. Synthetic simulations of optical sightlines and viewing cone geometry were used to calculate line-integrated emission from the plasma, particularly of the C III 465 nm line, to serve as a proxy for the T e ≈ 7 − 10 eV temperature region associated with the onset and evolution of divertor detachment. Neutral deuterium emission is also evaluated for comparison. The synthetic diagnostic is used to assess the performance of existing DIII-D optical systems, including filterscopes and the Multichord Divertor Spectrometer, and to optimize line-of-sight placement within mechanical and installation constraints. The results provide quantitative guidance for diagnostic implementation on DIII-D and demonstrate the advantage of integrated synthetic diagnostics for divertor design studies and future advanced divertor concepts.

Cherab↗

Millisecond-long suppression of spectroscopic optical signals using laser filamentation

Ultrashort laser pulse filamentation in air can extend the delivery of focused laser energy to distances greatly exceeding the Rayleigh length. In this way, remote measurements can be conducted using many standard methods of analytical spectroscopy. The performance of spectroscopic techniques can be enhanced by temporal gating, which rejects the unwanted noise and background. In the present work, we investigate the thermal relaxation of air in the wake of single-filament plasmas using shadowgraphy. Here, we demonstrate that the transient change in refractive index associated with relaxation of the gas can be used to reject both continuous and time-varying spectroscopic signals, including emission from laser-produced plasmas. This method can augment temporal gating of simple optical detectors.

47 OTHER INSTRUMENTATION↗

X-ray self-emission imaging with spherically bent Bragg crystals on the Z-machine

Here, an x-ray imaging scheme using spherically bent crystals was implemented on the Z-machine to image x rays emitted by the hot, dense plasma generated by a Magnetized Liner Inertial Fusion (MagLIF) target. This diagnostic relies on a spherically bent crystal to capture x-ray emission over a narrow spectral range (<15 eV), which is established by a limiting aperture placed on the Rowland circle. The spherical crystal optic provides the necessary high-throughput and large field-of-view required to produce a bright image over the entire, one-cm length of the emitting column of a plasma. The average spatial resolution was measured and determined to be 18 µm for the highest resolution configuration. With this resolution, the radial size of the stagnation column can be accurately determined and radial structures, such as bifurcations in the column, are clearly resolved. The success of the spherical-crystal imager has motivated the implementation of a new, two-crystal configuration for identifying sources of spectral line emission using a differential imaging technique.

47 OTHER INSTRUMENTATION↗

Foliar element determination from field survey in association with the National Ecological Observatory Network Airborne Observation Platform survey, East River, Colorado 2018

The purpose of this dataset is to support research aimed at understanding the coupling between hydrologic and biogeochemical processes at watershed scale, particularly the relationship between aboveground vegetation characteristics and subsurface soil properties. These data are intended to inform and calibrate models of catchment-scale biogeochemical fluxes, including rock-derived nutrient cycling, and they were procured to address the following questions: (1) What is the distribution of vegetation characteristics across the study catchments? (2) Are foliar concentrations of rock-derived nutrients related to underlying lithology and soil availability, or are these signals masked by biotic nutrient cycling and retention processes?This data package contains foliar elemental data collected during the 2018 National Ecological Observatory Networks (NEON) Airborne Observation Platform (AOP) imaging spectroscopy and lidar surveys in Gunnison County, Colorado. Folair samples were collected across the East River, Washington Gulch, Slate River, and Coal Creek watersheds and contain a mixture of vegetation including meadow, shrub, and tree foliar samples. The samples were processed using aqua regia digestion and analyzed for elemental determination on inductively coupled plasma optical emission spectrometry (ICP-OES).The data package includes: (1) raw foliar elemental data files in CSV and PDF formats, (2) quality control certificates in PDF format, and (3) an aggregated CSV file containing all elemental measurements compiled across samples. No specialized software is required to access or use these files.

2018 National Ecological Observatory Network Campa↗

Optical trapping and manipulation of single particles for MDP

This two-year project, conducted under Grant Number DE-SC0021030, focused on the development and application of advanced optical trapping and manipulation technologies to study magnetized dusty plasma (MDP) systems and enhance diagnostic capabilities at the Magnetized Dusty Plasma Experiment (MDPX) facility at Auburn University. The central objective was to enable precise, non-invasive control and measurement of single particles within plasma environments, thereby addressing key limitations in existing plasma diagnostic techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of machine learning for optical emission spectroscopy data in NAGDIS-II

In this study, we applied machine learning to optical emission spectroscopy (OES) data and device parameters from the linear plasma device NAGDIS-II to explore the potential application of machine learning for predicting electron density, $n$ e , and temperature, $T$ e . The covered ranges of $n$ e and $T$ e , which were measured by an electrostatic probe, are 3.6 × 10 17 –2.4 × 10 19 m -3 and 0.3–7.1 eV, respectively. A three hidden layer neural network (NN) is introduced to model the relationship between $n$ e /$T$ e and the combination of line intensities, radial position, and device parameters. It is shown that the errors in $n$ e and $T$ e become 18.0 and 18.8%, respectively, which were almost the same level for the electrostatic probe, using all available data. Lasso regression and greedy algorithm are used to select the necessary line emissions. In conclusion, it is shown that four- or five-line intensities are sufficient to obtain almost the same quality as the one with all the other lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatiotemporal evolution of emission and absorption signatures in a laser-produced plasma

Here we report spatiotemporal evolution of emission and absorption signatures of Al species in a nanosecond (ns) laser-produced plasma (LPP). The plasmas were generated from an Inconel target, which contained ~0:4 wt. % Al, using 1064 nm, ≈6 ns full width half maximum pulses from an Nd:YAG laser at an Ar cover gas pressure of ≈34 Torr. The temporal distributions of the Al I (394.4 nm) transition were collected from various spatial points within the plasma employing time-of-flight (TOF) emission and laser absorption spectroscopy, and they provide kinetics of the excited state and ground state population of the selected transition. The emission and absorption signatures showed multiple peaks in their temporal profiles, although they appeared at different spatial locations and times after the plasma onset. The absorption temporal profiles showed an early time signature representing shock wave propagation into the ambient gas. We also used emission and absorption spectral features for measuring various physical properties of the plasma. The absorption spectral profiles are utilized for measuring linewidths, column density, and kinetic temperature, while emission spectra were used to measure excitation temperature. A comparison between excitation and kinetic temperature was made at various spatial points in the plasma. Our results highlight that the TOF measurements provide a resourceful tool for showing the spatiotemporal LPP dynamics with higher spatial and temporal resolution than is possible with spectral measurements but are difficult to interpret without additional information on excitation temperatures and linewidths. The combination of absorption and emission TOF and spectral measurements thus provides a more complete picture of LPP spatiotemporal dynamics than is possible using any one technique alone.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Faraday Rotation Measurements in High-Energy-Density Plasmas Using Shaped Laser Beams

Magnetic fields play an important role in plasma dynamics, yet it is a quantity difficult to measure accurately with physical probes, whose presence disturbs the very field they measure. The Faraday rotation of a polarized beam of light provides a mechanism to measure the magnetic field without disturbing the dynamics, and has been used with great success in astrophysics and high energy density plasma science, where physical probes cannot be used. Furthermore, the rotation is typically small, which degrades the accuracy of the measurement. Since polarization cannot be measured directly, detectors rely on a polarizer to measure a small change in beam intensity instead. In this work, we show how beam shaping can improve Faraday rotation measurements using an optical derivative setup. Since the rotation measurement is now strictly proportional to the beam shape and intensity, the system allows to improve the measurement accuracy simply by increasing the laser beam power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrating fiber optic sensors into metallic components for sensing in harsh environments

The integration of fiber optic sensors into high-temperature materials is critical for real-time monitoring and autonomous operation of engineering systems. This study demonstrated a spark plasma sintering (SPS)-assisted embedding process for integrating sapphire fiber optic sensors into stainless steel components during part fabrication. Optical fibers were encapsulated in stainless steel 316L powders which were sintered at different fabrication conditions using SPS to investigate the effects of sintering parameters on the embedment. Measurements of optical transmittance, combined with microstructural analysis (X-ray computed tomography and scanning electron microscopy) and mechanical testing (tensile and microhardness), were conducted to examine the fiber functionality, fiber–matrix bonding quality, and properties of the sintered materials. Here, the results show that under suitable fabrication conditions, intact optical fibers can be encapsulated in highly-densified (>98 % relative density) stainless steel components. These conditions also led to a good bond at the fiber–matrix interface with micron-sized material interdiffusion across the interface. The sintering parameters were observed to affect fiber optical attenuation, where high temperature, pressure, and hold time during SPS enhanced fiber–matrix bonding and adversely affected optical transmission. Tensile testing confirmed the superior tensile strength and ductility of the matrix fabricated by SPS. Furthermore, the materials exhibited limited strength reduction (~70 MPa) upon the integration of fibers. This study demonstrates the effectiveness of SPS for fiber-material integration for high-temperature applications.

36 MATERIALS SCIENCE↗

Photonic integration of Er 3+ :Y 2 SiO 5 with thin-film lithium niobate by flip chip bonding

Rare earth ions are known as promising candidates for building quantum light-matter interface. However, tunable photonic cavity access to rare earth ions in their desired host crystal remains challenging. Here, we demonstrate the integration of erbium doped yttrium orthosilicate (Er 3+ :Y 2 SiO 5 ) with thin-film lithium niobate photonic circuit by plasma-activated direct flip chip bonding. Resonant coupling to erbium ions is realized by on-chip electro-optically tuned high Q lithium niobate micro-ring resonators. Fluorescence and absorption of erbium ions at 1536.48 nm are measured in the waveguides, while the collective ion-cavity cooperativity with micro-ring resonators is assessed to be 0.36. This work presents a versatile scheme for future rare earth ion integrated quantum devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation transfer in the spectra of short-pulse laser-heated targets

The conditions in laser-produced plasmas are frequently determined with x-ray spectroscopy by comparing calculated to measured spectra. Line spectra from K-shell transitions of low- to mid-atomic number elements are most often used since the important physical processes are well understood and reliable spectra can be readily measured and calculated. Radiation transfer effects due to large optical depths of strong lines can influence the spectra. In this work, the effects of radiation transfer on the emission spectra of short-laser pulse-heated targets are studied. The possible errors made in inferring electron temperature by not including radiation transfer are quantified. The inclusion of radiative transfer in spectral calculations improves the accuracy of typical temperature diagnostics and allows the use of strong lines for diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗