Search NASA⌕ Search

SEARCH · Search NASA

Results for “PARTICLE IDENTIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Scintillating glass for precision calorimetry in nuclear physics

High-performance scintillator materials are needed for particle identification and measurements of energy and momentum of electromagnetic particles in modern nuclear physics experiments. As an example, the US Electron-Ion Collider, a unique collider with diverse physics topics, requires electromagnetic calorimetry enabling high-quality electron identification and detection in the momentum range of 0.3 to tens of GeV. The highest resolution in electromagnetic calorimeters can be provided by homogeneous materials, e.g., lead tungstate crystals. Inorganic glass scintillators have been investigated as an attractive and cost-effective alternative to crystals, that is also easier and faster to manufacture in mass production. In this paper, we discuss progress in the fabrication and characterization of recent scintillating glass samples on both test bench and beam tests. Further, the results are well-reproduced by simulation and are discussed in the context of the Electron-Ion Collider experimental requirements and bench-marked against lead tungstate crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization of the first CUPID detector module

CUPID will be a next generation experiment searching for the neutrinoless double β decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li 2 100 MoO 4 crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of α particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 ± 0.2) keV FWHM at the Q-value of 100 Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors’ mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an α particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement report: The Fifth International Workshop on Ice Nucleation phase 1 (FIN-01): intercomparison of single-particle mass spectrometers

Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.

54 ENVIRONMENTAL SCIENCES↗

BlueSTEAl: A pair of silicon arrays and a zero-degree phoswich detector for studies of scattering and reactions in inverse kinematics

BlueSTEAl, the Blue (aluminum chamber of) Silicon TElescope Arrays for light nuclei, has been developed to study direct reactions in inverse kinematics, as well as scattering and breakup reactions using radioactive ion beams. It is a detector system consisting of a pair of annular silicon detector arrays and a zero-degree phoswich plastic scintillator. For typical binary reaction studies in inverse kinematics, light ions are detected by the Si array in coincidence with heavy recoils detected by the phoswich placed at the focal-plane of a zero-degree magnetic spectrometer. The Si array can also be used to detect light nuclei such as beryllium and carbon with clear isotope separation, while the phoswich can also be placed at zero degrees without a spectrometer and used as a high-efficiency beam counting monitor with particle identification capability at the rate of up to ~5 × 10 4 particles per second. This paper reports on the capabilities of BlueSTEAl as determined by recent experiments performed at the Texas A&M Cyclotron Institute. Furthermore, the device is also anticipated to be used in future experiments at other radioactive ion beam facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the muon neutrino charged-current zero mesons cross section measurement in the NOvA near detector

NOvA is a long-baseline accelerator neutrino experiment at Fermilab whose physics goals include precision neutrino oscillation as well as cross-section measurements. We present the status of the measurement of muon neutrino charged-current cross section with zero mesons in the final state at the NOvA near detector. This measurement will be made with respect to the kinematics of the final state particles. Our chosen interaction channel is especially sensitive to quasielastic and meson exchange current interactions and will provide a handle for constraining the cross section systematic uncertainties in oscillation analyses in current and future experiments. For particle identification, we use a convolutional neural network (CNN) trained on individual particles simulated in the NOvA near detector that allows us to select the desired signal while reducing the potential bias from neutrino interaction modeling. Charged pion background constraining is further improved via Michel electron tagging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the Muon Neutrino Charged-Current Mesonless Cross Section Measurement in the NOvA Near Detector

NOvA is a long-baseline accelerator neutrino experiment at Fermilab whose physics goals include precision neutrino oscillation as well as cross-section measurements. We present the status of the measurement of a muon neutrino charged-current cross section with zero mesons in the final state at the NOvA near detector. This measurement is being made with respect to the kinematics of the final state muon. The chosen interaction channel is especially sensitive to quasielastic and meson exchange current interactions and aims to provide experimental constraints for the development of models of neutrino interactions. It will also provide a handle for constraining cross section systematic uncertainties in oscillation analyses in current and future experiments. For particle identification, we use a convolutional neural network (CNN) trained on individual particles simulated in the NOvA near detector that allows us to select the desired signal while reducing the potential bias from neutrino interaction modeling. Charged pion background constraining is further improved via Michel electron tagging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the Muon Neutrino Charged-Current Zero Mesons Cross Section at the NOvA Near Detector

NOvA is a long-baseline accelerator neutrino experiment at Fermilab whose physics goals include precision neutrino oscillation as well as cross-section measurements. We present the status of the measurement of a muon neutrino charged-current cross section with zero mesons in the final state at the NOvA near detector. This measurement is being made with respect to the kinematics of the final state muon. The chosen interaction channel is especially sensitive to quasielastic and meson exchange current interactions and aims to provide experimental constraints for the development of models of neutrino interactions. It will also provide a handle for constraining cross section systematic uncertainties in oscillation analyses in current and future experiments. For particle identification, we use a convolutional neural network (CNN) trained on individual particles simulated in the NOvA near detector that allows us to select the desired signal while reducing the potential bias from neutrino interaction modeling. Charged pion background constraining is further improved via Michel electron tagging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the muon neutrino charged-current mesonless cross section in the NOvA near detector

NOvA is a long-baseline accelerator neutrino experiment at Fermilab. Its physics goals include precision neutrino oscillation measurements, neutrino interaction cross-section measurements and beyond Standard Model explorations. We present a measurement of muon neutrino charged-current cross section with zero mesons in the final state at the NOvA near detector. This measurement is performed as a function of the kinematics of the final state muon. Our chosen interaction channel is especially sensitive to quasielastic and meson exchange current interactions and it provides handles for constraining the cross section systematic uncertainties in oscillation analyses in present and future experiments. For particle identification, we use a convolutional neural network (CNN) trained on individual particles simulated in the NOvA Near detector. This allows us to select the desired signal while reducing the potential bias from neutrino interaction modeling. We study strategies for constraining the remaining charged-pion background via Michel electron information in a template fitting approach. The main experimental result is a two-dimensional differential cross section as a function of final-state muon kinetic energy and polar angle. The parameters of this measurement, including binning and unfolding, were optimized to reduce the expected systematic uncertainty in the total cross section. The final result shows good agreement with the main GENIE-based simulation framework that was independently fine-tuned in NOvA. We finally propose improvements and subsequent steps that build on this analysis and further dissect the final states of neutrino interactions. This work has been supported by US DOE grant DE-SC0015684.

Sánchez Falero, Sebastián Jesús [Iowa State U.]↗

The Mu2e Tracker

The Mu2e experiment will search for neutrinoless conversion of muons into electrons In the field of an aluminum nucleus. The signature of this process is an electron with energy nearly equal to the muon mass. Precise and robust measurement of the outgoing electron momentum, combined with other background rejection methods, is essential to the experiment. We rely on a low-mass straw tube tracker to achieve these goals. The tracking system must operate in a vacuum and a 1 Tesla magnetic field. We have chosen to use about 20,000 thin-wall Mylar straws held under tension to avoid the need for support within the active volume. In addition to measuring the distance from the wire by drift time, subnanosecond measurement of signal propagation time will be used to measure position along the wire. The charge will be measured using ADCs to provide particle identification capability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searching for Short-Range Correlations in $^{40}AR$

The neutrino charged current (CC) cross section is critical for understanding neutrino oscillations as the flavor of a neutrino can only be determined by its CC interaction. As future generations of neutrino detectors will use argon as a target nucleus, it’s important to understand the influence that nuclear effects have on neutrino-nucleon cross sections. Short range correlations (SRCs) are an example of such an effect that are known to contribute non-trivially to the CC cross section. In MicroBooNE, a CC interaction with a correlated nucleon would lead to a 1 muon, 2 proton topology (CC2p). In order to study SRCs in MicroBooNE, It is crucial that the particle identification (PID) techniques used are efficient in identifying CC2p signals from background. Convolutional neural networks (CNN) have shown great promise in their ability to distinguish objects in an image from a noisy background. We present here our work towards the development of a CNN for CC2p event selection and identification.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of shashlik electromagnetic calorimeter prototype for SoLID

A shashlik electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for Solenoidal large Intensity Device (SoLID) to measure the energy deposition of electrons and hadrons, and to provide particle identification after the energy of the accelerator was upgraded to 12 GeV. Tsinghua University is the member of Hall A collaboration in charge of development and production of the large shashlik electromagnetic calorimeter of SoLID. One module of that calorimeter is composed by 194 layers. Each layer consists of a 1.5 mm thick plastic scintillator put on top of a 0.5 mm thick lead plate. Scintillation light is read out by wave-length shifter fibers penetrating through the calorimeter modules longitudinally along the direction of flight of the impact particle. This paper describes the design and construction of that module, as well as a few optimization studies meant to improve its performance. A detailed Geant4 simulation also shows that an energy resolution of 5%/√ E (GeV) and a good containment for electromagnetic showers can be achieved, as well as some basic electron identification. In conclusion, a prototype of that module will be tested soon with an electron beam at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Heavy Photon Search experiment at Jefferson Laboratory

Many beyond Standard Model theories predict a new massive gauge boson, a.k.a. 'dark' or 'heavy photon', directly coupling to hidden sector particles with dark charge. The heavy photon is expected to mix with the Standard Model photon through kinetic mixing and therefore couple weakly to normal charge. The Heavy Photon Search (HPS) experiment will search for the heavy photon at the Thomas Jefferson National Accelerator Facility (JLab), in the mass range 20-1000 MeV/c 2 and coupling to electric charge ϵ 2 = α'/α in the range 10 -5 to 10 -10 . HPS will look for the e + e - decay channel of heavy photons radiated by electron Bremsstrahlung, employing both invariant mass search and detached vertexing techniques. The experiment employs a compact forward spectrometer comprising silicon microstrip detectors for vertexing and tracking and an electromagnetic calorimeter for particle identification and triggering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Statistical Prescription to Estimate Properly Normalized Distributions of Different Particle Species

We describe a statistical method to avoid biased estimation of the content of different particle species. We consider the case when the particle identification information strongly depends on some kinematical variables, whose distributions are unknown and different for each particles species. We show that the proposed procedure provides properly normalized and completely data-driven estimation of the unknown distributions without any a priori assumption on their functional form. Moreover, we demonstrate that the method can be generalized to any kinematical distribution of the particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress of the Charged Pion Semi-Inclusive Neutrino Charged Current Cross Section in NOvA

The NOvA experiment is a long-baseline neutrino oscillation experiment designed to measure the rates of electron neutrino appearance and muon neutrino disappearance. The NOvA near detector is located at Fermilab, 800 m from the primary target and provides an excellent platform to measure and study neutrino-nucleus interactions. We present the status of the measurement of the double differential cross section with respect to muon kinematics for interactions involving charged pions in the final state, $\nu_{\mu} + N \rightarrow \mu + \pi^{+/-} + X$. We have derived a convolutional neural network-based approach for the identification of neutrino interactions with the specific final state topology. We present event classification efficiency studies using this particle identification and classification methodology, along with systematic uncertainties and prospects for the measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detectors and diagnostics for multiprobe radiography using high-energy short-pulse lasers

Multiprobe radiography requires the following diagnostic capabilities at minimum: radiographic source diagnostics, spectroscopy, imaging, and tomography diagnostics. Depending on the repetition rate of the radiation sources, the diagnostics may be a single-shot diagnostic, such as photographic (radiochromic and X-ray films for high energy photons) films, or a multiple-shot diagnostic for repetitive source operations, such as a high-speed framing camera. Due to the drastically different detector physics of electrons, photons at different energies (keV to 10s of MeV in the radiography context), heavy ions such as protons, alphas, and neutrons, see, for example, Ref. [1, 2] for an overview, different types or configurations of detectors and constructions may be required for multiprobe radiography applications. Some of the common detector metricsinclude, independent of the particle/photon species, sensitivities or efficiency, energy resolution, spatial or temporal resolutions and others. Some unique detection scenarios arise in a multiprobe radiography setting, for example, crosstalk mitigation and particle identification (ID) when X-ray and higher energy photons, relativistic electrons, neutrons, other hadrons, and heavy particles coexist at the detector location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-neutron spectrometer developments

Li6 sandwich-type neutron spectrometer is equipped with proportional counter for particle identification. System uses current-sensitive preamplifiers to minimize pile-up of gamma-ray and particle pulses.

Moler, R. B.↗

The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and then detecting the de-excitation X-rays and the nuclear annihilation products. This measurement is realized using a Tracker composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40m$^2$. Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign. We detail the design, integration, and commissioning of the payload prior to flight.

Aoyama, Kazutaka [JAXA, Sagamihara]↗