Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Signal acquisition system

A frequency-tracking feedback circuit for acquiring a communication carrier signal from a relatively noisy environment. The circuit includes a digital phase-frequency detector, a limiter, a mixer, and a voltage-controlled oscillator, connected in a long control loop in such a manner that an input band of signals is translated in frequency until the desired carrier is centered within a relatively narrow acquisition window. The characteristics of the loop are such that acquisition may be achieved even when the total power of the noise in the input signal band exceeds the carrier power, provided that the noise is relatively uniformly distributed over the input band. A technique is also disclosed for compensating from any unbalance in the noise spectrum, so that relatively low carrier-to-noise ratios can be tolerated. Also disclosed are improvements for dynamically varying the parameters of the frequency-tracking loop in such a manner as to reduce acquisition time, and a technique for detecting acquisition and handing control to post-acquisition control circuitry.

Crackel, John E.↗

Particle tracks recorded by ProtoDUNE

This 3-D display shows particle tracks recorded by ProtoDUNE. The video shows the full size of the single-phase ProtoDUNE detector (white box) and the direction of the particle beam (yellow arrow). Particles from other sources (such as cosmic rays) can be seen throughout the white box, while the red box highlights the region of interest: in this case, an interaction resulting from the particle beam passing through the detector. Event information, such as the momentum of particles in the beam and time of interaction, are located in the lower left corner. A selection of 3-D events from ProtoDUNE-SP are available in an online gallery developed by Chao Zhang of Brookhaven National Laboratory (https://www.phy.bnl.gov/twister/bee/s...) for curious minds that want to play with the interface. Learn more about ProtoDUNE here: http://news.fnal.gov/2019/01/success-... And learn more about DUNE here: http://www.fnal.gov/dune

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

Akerib, DS↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic carrier acquisition system for phase-lock-loop receivers

Programmable oscillator and zero-beat detector acquires phase-lock of carrier by frequency scanning. Generation of high-level dc pulse at instant of zero crossing provides positive trigger for decision gate to stop search and close loop for phase-coherent tracking.

Bunce, R. C.↗

Probing New Physics with Tau Leptons using the CMS Detector

The Standard Model (SM) of particle physics is a thoroughly well-tested theory of all electroweak scale phenomena to date—the most recent test being the discovery of the long-predicted Higgs boson. However, there is much evidence to suggest that it is incomplete. On the formal side, the mass of the Higgs particle itself is perplexingly small, while the largest theoretical energy scale of the SM is 17 orders of magnitude larger, a puzzle known as the hierarchy problem. On the experimental side, among other things, the SM lacks a candidate for dark matter, which is now known to play an indispensable role in astrophysical large scale structure formation. Many theories that address the fundamental puzzles of the SM predict the existence of multiple Higgs bosons, including a very light boson that couples preferentially to third-generation fermions. Observation of this new light boson, either directly produced or in the decay of the recently discovered SM Higgs, would provide an unmistakable sign of new dynamics in nature. The research supported by this award used data collected by the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC) to explore boosted di-tau signatures of a new light boson as a tool in the quest to understand the shortcomings of the SM. With a proton-proton collision energy of 13 trillion electron-volts (TeV) and peak instantaneous proton luminosity of over 10^34 collisions per square centimeter per second (cm –2 s –1 ), the LHC is the only facility in the world that could enable this line of research. The research sought to address the hierarchy problem and other shortcomings of the SM through a mixture of LHC data analysis, maintenance of the CMS detector to ensure high quality data, and contributions to the Phase 2 upgrade detector for the upcoming High Luminosity phase of the LHC (HL-LHC).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-point measurements of ULF wave phases using a multi-channel energetic ion detector

The oscillation of differential fluxes of energetic ions modulated by a ULF wave often shows a phase shift between measurements in back-to-back detectors with look directions perpendicular to the ambient magnetic field. In a plasma of a single ion species, the phase difference is caused by displacement of the effective measurement positions by one ion gyroradius to each side of the detector. As the wave phase is periodic, the observed phase shift can correspond to a family of possible wavelengths. Simultaneous measurements of the flux modulations in different energy channels, which are equivalent to measurements of the wave phase at different positions, may make it possible to single out a unique wavelength consistent with all the measurements. Using the medium-energy-particle experiments ISEE-1 and 2, each of which may serve as a back-to-back detector, the above method was applied to a compressional Pc 5 wave observed near the equatorial plane at L between about 7 and 11. The transverse propagation properties of the wave were determined unambiguously.

Lin, N.↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Layout and performance of HPK prototype LGAD sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology, will cover the pseudo-rapidity region of 2.4 < |n| < 4.0 with two end caps on each side and a total area of 6.4 m 2 . The timing performance can be improved by implanting an internal gain layer that can produce signals with a fast rising edge. It significantly improves the signal-to-noise ratio. The required average timing resolution per track for a minimum ionizing particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1MeV neutron-equivalent fluence up to 2.5 10 15 n eq /cm 2 including a safety factor of 1.5 before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-ups at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

47 OTHER INSTRUMENTATION↗

CUPID-0: the first array of enriched scintillating bolometers for 0$\nu \beta \beta$ decay investigations

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of 82 Se neutrinoless double-beta decay (0$\nu \beta \beta$). CUPID0 aims at measuring a background index in the region of interest (RoI) for 0$\nu \beta \beta$ at the level of 10 -3 counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn 82 Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Detectability of QCD phase transitions in binary neutron star mergers: Bayesian inference with the next generation gravitational wave detectors

We study the detectability of postmerger QCD phase transitions in neutron star binaries with next-generation gravitational-wave detectors Cosmic Explorer and Einstein Telescope. We perform numerical relativity simulations of neutron star mergers with equations of state that include a quark deconfinement phase transition through either a Gibbs or Maxwell construction. These are followed by Bayesian parameter estimation of the associated gravitational-wave signals using the nrpmw waveform model, with priors inferred from the analysis of the inspiral signal. We assess the ability of the model to measure the postmerger peak frequency $f$$^{peak}_{2}$ and identify aspects that should be improved in the model. We show that, even at postmerger signal to noise ratios as low as 10, the model can distinguish (at the 90% level) $f$$^{peak}_{2}$ between binaries with and without a phase transition in most cases. Phase-transition induced deviations in the $f$$^{peak}_{2}$ from the predictions of equation-of-state insensitive relations can also be detected if they exceed 1.6⁢σ. Our results suggest that next-generation gravitational wave detectors can measure phase transition effects in binary neutron star mergers. Furthermore, unless the phase transition is “strong,” disentangling it from other hadronic physics uncertainties will require significant theory improvements.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase Retrieval with Signal Bias

The effect of a uniform measurement bias, due to background light, stray light, detector dark current, or detector offset, on phase retrieval wavefront sensing algorithms is analyzed. Simulation results indicate that the root-mean-square error of the retrieved phase can be more sensitive to an unaccounted-for signal bias than to random noise in practical scenarios. Three methods for reducing the impact of signal bias are presented

Thurman, Samuel T.↗