Search NASA⌕ Search

SEARCH · Search NASA

Results for “PITTING CORROSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The stress corrosion resistance and the cryogenic temperature mechanical properties of annealed Nitronic 60 bar material

Ambient and cryogenic temperature mechanical properties and the ambient temperature stress corrosion properties of annealed, straightened, and centerless ground Nitronic 60 stainless steel alloy bar material are presented. The mechanical properties of longitudinal specimens were evaluated at test temperatures from ambient to liquid hydrogen. The tensile test data indicated increasing strength with decreasing temperature to -196 C. Below liquid nitrogen temperature the smooth tensile and notched tensile strengths decreased slightly while the elongation and reduction of area decreased drastically. The Charpy V-notched impact energy decreased steadily with decreasing test temperature. Stress corrosion tests were performed on longitudinal tensile specimens and transverse C-ring specimens exposed to: alternate immersion in a 3.5% NaCl bath; humidity cabinet; and a 5% salt spray atmosphere. The longitudinal tensile specimens experienced no corrosive attack. Approximately 3/4 of the transverse C-rings exposed to alternate immersion and to salt spray experienced a pitting attack on the top and bottom ends. Additional stress corrosion tests were performed on transverse tensile specimens. No failures occurred in the 90% stressed specimens exposed for 90 days in the alternate immersion and salt spray environments

Montano, J. W. L.↗

A first-principles study of hydrogen surface coverage on δ-Pu (100), (111), and (110) surfaces

Hydriding corrosion of plutonium leads to surface cracking, pitting, and ultimately structural failure. Laboratory experiments demonstrate that hydriding begins on the surface or near the subsurface of plutonium. However, there has not yet been a systematic evaluation of hydrogen surface coverage on plutonium. In this work, we compute the surface energies of the low facet surfaces of face-centered cubic δ-Pu. The adsorption free energies of expected hydrogen structures at low and high coverage are presented along with the likely progression for filling sites as the H 2 partial pressure increases. Implications for near-equilibrium pressure hydride nucleation and non-equilibrium millibar pressure hydriding are discussed.

36 MATERIALS SCIENCE↗

Halogen Removal from Tritium Gas Streams

Halogen impurities are poisonous and/or corrosive • Poison for catalysts and equipment • Causes pitting in most austenitic stainless steels • Minimized to prevent damage over time • Prone to appear in certain processes • Appear if certain materials degrade (i.e., elastomers, etc.) • Present as trace impurities in a large number of metals and zeolites (<200 ppm)

Angelette, Lucas M.↗

Design of a Borescope for Extravehicular Non-Destructive Applications

Anomalies such as corrosion, structural damage, misalignment, cracking, stress fiactures, pitting, or wear can be detected and monitored by the aid of a borescope. A borescope requires a source of light for proper operation. Today s current lighting technology market consists of incandescent lamps, fluorescent lamps and other types of electric arc and electric discharge vapor lamp. Recent advances in LED technology have made LEDs viable for a number of applications, including vehicle stoplights, traffic lights, machine-vision-inspection, illumination, and street signs. LEDs promise significant reduction in power consumption compared to other sources of light. This project focused on comparing images taken by the Olympus IPLEX, using two different light sources. One of the sources is the 50-W internal metal halide lamp and the other is a 1 W LED placed at the tip of the insertion tube. Images acquired using these two light sources were quantitatively compared using their histogram, intensity profile along a line segment, and edge detection. Also, images were qualitatively compared using image registration and transformation [l]. The gray-level histogram, edge detection, image profile and image registration do not offer conclusive results. The LED light source, however, produces good images for visual inspection by an operator. Analysis using pattern recognition using Eigenfaces and Gaussian Pyramid in face recognition may be more useful.

Bachnak, Rafic↗

Reverse martensitic transformation on the corrosion behavior of a 2304 lean duplex stainless steel

This study investigates the influence of the reverse martensitic transformation on the corrosion behavior of 2304 lean duplex stainless steel (LDSS) at low temperatures (400–600°C). The steel underwent cold rolling, followed by isochronal annealing for 0.5 h. Phase transformations and microstructures were analyzed using X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. Corrosion resistance was evaluated using a syringe cell with cyclic potentiodynamic polarization in 0.6 M NaCl solution and double-loop electrochemical potentiokinetic reactivation in 0.5 M H 2 SO 4 + 0.001 M KSCN solution. A bimodal breakdown potential behavior, associated with either pitting or transpassivity, was observed in the as-received (AR) and samples annealed at 400°C. Pitting in the AR sample was associated with Al–Mg–Si–Ca–O inclusions, while pitting on the samples annealed at 400°C was linked to local reduced passive film resistance. Severe cold rolling enhanced the pitting resistance of 2304 LDSS. Selective electrochemical etching revealed preferential corrosion at phase interfaces and within the austenite phase. Additionally, annealing at 500°C to 600°C led to a marked decrease in pitting resistance and increased sensitization. Electron backscatter diffraction analysis of the corroded pits in the annealed specimens indicated that pits tend to nucleate and grow in α'-martensite/austenite regions. Furthermore, the nanostructure formed during low-temperature reversion, characterized by dislocation-cell martensite with high dislocation density and stacking faults, may adversely affect corrosion resistance due to heterogeneities associated with alloying element redistribution.

36 MATERIALS SCIENCE↗

Quantitative assessment of environmental phenomena on maximum pit size predictions in marine environments

Maximum pit sizes were predicted for dilute and concentrated NaCl and MgCl 2 solutions as well as sea-salt brine solutions corresponding to 40% relative humidity (RH) (MgCl 2 -rich) and 76% RH (NaCl-rich) at 25 °C. A quantitative method was developed to capture the effects of various cathode evolution phenomena including precipitation and dehydration reactions. Additionally, the sensitivity of the model to input parameters was explored. Despite one's intuition, the highest chloride concentration (roughly 10.3 M Cl – ) did not produce the largest predicted pit size as the ohmic drop was more severe in concentrated MgCl 2 solutions. Therefore, the largest predicted pits were calculated for saturated NaCl (roughly 5 M Cl – ). Next, it was determined that pit size predictions are most sensitive to model input parameters for concentrated brines. However, when the effects of cathodic reactions on brine chemistry are considered, the sensitivity to input parameters is decreased. Although there was not one main input parameter that influenced pit size predictions, two main categories were identified. Under similar chloride concentrations (similar RH), the water layer thickness (WL), and pit stability product, (i · x) sf , are the most influential factors. When varying chloride concentrations (RH), changes in WL, the brine specific cathodic kinetics on the external surface (captured in the equivalent current density (i eq )), and conductivity (k o ) are the most influential parameters. Finally, it was noted that dehydration reactions coupled with precipitation in the cathode will have the largest effect on predicted pit size, and cause the most significant inhibition of corrosion damage.

54 ENVIRONMENTAL SCIENCES↗

Corrosion Response of Ni-19Cr-5Fe in Molten NaCl-MgCl 2 Salt

Ni-based alloys are strong candidates for use in high-temperature molten salt reactors due to their superior corrosion resistance and mechanical stability compared to stainless steels. In this study, the static corrosion behavior of a Ni-19Cr-5Fe model alloy was systematically evaluated in a purified molten NaCl-MgCl 2 salt at 700°C for 30, 240, and 500 h. Post-exposure analyses were conducted to assess microstructural evolution, corrosion depth, and elemental depletion profiles. Corrosion rates, quantified by chromium depletion depth, followed an inverse power-law trend with increasing exposure time, indicating diffusion-limited kinetics. This trend is attributed to limitations in mass transport in the static salt and to the progressive local depletion of reactive chromium species. Coupled electron backscatter diffraction and energy dispersive X-ray spectroscopy analysis further revealed that the grain boundary character significantly influences corrosion susceptibility: high-angle grain boundaries exhibited pronounced Cr depletion and pitting, while low-angle and Σ3 boundaries remained comparatively resistant. These results offer valuable insight into the role of microstructure in corrosion processes and reinforce the importance of time-dependent material evaluation in molten salt environments relevant to advanced reactor designs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of the stress corrosion cracking resistance of several high strength low alloy steels

The stress corrosion cracking resistance was studied for high strength alloy steels 4130, 4340, for H-11 at selected strength levels, and for D6AC and HY140 at a single strength. Round tensile and C-ring type specimens were stressed up to 100 percent of their yield strengths and exposed to alternate immersion in salt water, salt spray, the atmosphere at Marshall Space Flight Center, and the seacoast at Kennedy Space Center. Under the test conditions, 4130 and 4340 steels heat treated to a tensile strength of 1240 MPa (180 ksi), H-11 and D6AC heat treated to a tensile strength of 1450 MPa (210 ksi), and HY140 (1020 MPa, 148 ksi) are resistant to stress corrosion cracking because failures were not encountered at stress levels up to 75 percent of their yield strengths. A maximum exposure period of one month for alternate immersion in salt water or salt spray and three months for seacoast is indicated for alloy steel to avoid false indications of stress corrosion cracking because of failure resulting from severe pitting.

Humphries, T. S.↗

Variation of the Passive Film on Compositionally Concentrated Dual-Phase Al 0.3 Cr 0.5 Fe 2 Mn 0.25 Mo 0.15 Ni 1.5 Ti 0.3 and Implications for Corrosion

The passive film on a dual-phase Al 0.3 Cr 0.5 Fe 2 Mn 0.25 Mo 0.15 Ni 1.5 Ti 0.3 FCC + Heusler (L2 1 ) compositionally concentrated alloy formed during extended exposure to an applied potential in the passive range in dilute chloride solution was characterized. Each phase, with its own distinct composition of passivating elements, formed unique passive films separated by a heterophase interface. High-resolution, surface sensitive characterization enabled chemical analysis of the passive film formed over individual phases. The film formed over the L2 1 phase had a higher concentration of Al, Ni, and Ti, while the film formed over FCC phase was of similar thickness but contained comparatively higher Cr, Fe, and Mo concentrations, consistent with the differences in bulk microstructure composition. The passive film was continuous across phase boundaries and the distribution of passivating elements (Al, Cr, and Ti) indicated both phases were independently passivated. Spatially resolved analysis of the surface chemistry of the dual-phase CCA revealed that the cation with the highest composition in passive film formed on the FCC phase was Cr (52.4 at. pct) and for the L2 1 phase was Ti (53.1 at. pct) despite the bulk concentration of each element being below 20 at. pct in their respective phases. Al, Cr, and Ti were enriched in both phases within the passive film relative to their respective bulk compositions. In parallel studies, single-phase alloys with compositions representative of the FCC and L2 1 phases were synthesized to evaluate the corrosion behavior of each phase in isolation. The corrosion behavior of the dual-phase alloy showed passivity evidenced by a pitting potential of 0.615 V SCE in 0.01 M NaCl. The pitting potential and other electrochemical parameters suggested a combination of behaviors of both single-phase samples, suggesting that the global corrosion behavior may be represented by a composite theory applied to phases, their area fractions, and interphase length. However, the interphase in the dual-phase CCA was a local corrosion initiation site and may limit localized corrosion protectiveness. The alloy design implications for optimization of second phase structure and morphology are discussed.

36 MATERIALS SCIENCE↗

Corrosion of metals and alloys in sulfate melts at 750 C

The corrosion of Ni, Co, Ni-10Cr, Co-21Cr, and IN738 was studied at 750 C in the presence of molten sulfate mixtures (Na2SO4-Li2SO4 and Na2SO4-CoSO4) and in an atmosphere consisting of O2 + 0.12 percent SO2-SO3. The corrosion was observed to be similar for both Na2SO4-Li2SO4 and Na2SO4-CoSO4 melts. The corrosion of Ni and Co took place by the formation of a mixed oxide plus sulfide scale, very similar to the corrosion in SO2 or SO3 alone. The initial stage for the corrosion of Ni-10Cr involved the formation of a thick NiO + Ni3S2 duplex scale, and Cr sulfide was formed during the later stages. A pitting type of morphology was observed for both Co-21Cr and IN738. The pit was Cr sulfide at the beginning, and subsequently the sulfides oxidized to Cr2O3. A base-metal oxide layer was present above the pit, and this was observed to be formed very early in the corrosion process. A mechanism is proposed to explain this. In general, the formation of sulfides appears to be the primary mode of degradation in mixed sulfide melts.

Misra, A. K.↗

Hot corrosion of silicon carbide and silicon nitride at 1000 C

The sodium sulfate hot corrosion of silicon-based ceramics at 1000 C has been extensively studied. Deposition of the sodium sulfate corrodant from combustion products is discussed in relation to sodium air impurity and sulfur fuel impurity content. Corrosion occurs by the combined processes of oxidation to form protective silica scales and dissolution of these scales to form nonprotective sodium silicates. The chemical corrosion mechanisms are presented in terms of acidic/basic dissolution of oxides in molten salts. The reactions are strongly influenced by the presence of free carbon in the ceramic. Strength reductions have been measured and are attributed to pitting in SiC and grain boundary attack in Si3N4. Initial results of burner corrosion of two ceramic matrix composites are consistent with the models developed for monolithic ceramics.

Fox, Dennis S.↗

MIS Shelf-Life Final Report for Plutonium Oxide Item 1000089 (SSR136 and SSR136A) from Rocky Flats Peroxide Precipitation and Calcination Process

A plutonium dioxide material from the Material Identification and Surveillance (MIS) Program inventory has been studied to determine the gas generation and corrosion behavior in a storage environment. Sample 1000089 represents product-quality plutonium oxides produced in the Rocky Flats peroxide precipitation process currently stored in 3013 containers. This study followed over time the gas pressure and composition of a sample with nominally 0.5 wt% water in a sealed container with an internal volume scaled to 1/500th of the volume of a 3013 container. Gas compositions had been measured periodically over almost 13 years. The maximum observed gas pressure was 204 kPa and was related to a temperature excursion. The maximum observed gas pressure from gas generation was 126 kPa. The increase over the initial pressure of 86.7 kPa was due to the generation of hydrogen, oxygen, and nitrogen. Carbon dioxide, methane and carbon monoxide were minor components of the headspace gas. The material exhibited unusual behavior in that the atmosphere reached flammable levels of hydrogen and oxygen within the first 30 days and remained flammable for the duration of the experiment. It has been determined that the sample inside the reactor was a mixture of the AR material, material calcined at 800 °C, and material calcined at 950 °C. The experiment was terminated in 2012 and unloaded in 2016. A new reactor, SSR136A, was loaded with the original sample freshly calcined at 950 °C. The total pressure inside SSR136A remained close to the initial value of 93 kPa. The total pressure is composed of He (steady levels after the reloading) and hydrogen which is 10% of the reactor’s total pressure. Nitrogen and oxygen compose trace amounts of the reactor headspace. The internal components of SSR136 were inspected in 2021, five years after it was removed from the array. The inside surfaces of the inner bucket exposed to the original sample for 4,576 days had an etched appearance, and pit-like features were observed in the microscopic analysis. No corrosion was observed on the SSR136A inner bucket that held the freshly calcined sample that was exposed for 1,303 days.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

STATISTICAL ANALYSIS OF IN-SERVICE ULTRASONIC INSPECTION DATA OF WASTE TANKS AT THE SAVANNAH RIVER Site-25021

Liquid radioactive waste has been stored in large, underground carbon steel tanks of 4.92-million-liter capacity at the United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina since the 1950s. The In-service inspection of the Savannah River Site High Level Waste tanks will be reviewed as well as Ultrasonic testing (UT) for detecting for general wall thinning, pitting and interface attack through accessible regions of the tanks. In-service inspection [1] of the Savannah River Site (SRS) High Level Waste (HLW) tanks is an essential element of a comprehensive structural integrity program. Inspection confirmed the effectiveness of chemistry and temperature controls used to preclude localized and general corrosion of the tanks. Ultrasonic testing is used to detect general wall thinning, pitting and interface attack, as well as vertically oriented cracks through inspection of a 21.59 cm (8.5-in.) wide strip extending over the accessible height of the primary tank wall.

Harris, Stephen P.↗

Hot corrosion behavior of 304 & P91 graded composite transition joint under molten sulfate salts

A novel graded composite transition joint (GCTJ) between AISI 304 stainless steel and ASTM A335 P91 steel, has been demonstrated remarkablely superior creep performance compared to the conventional dissimilar metal weldment (DMW) under equivalent conditions. However, this advance is challenged by hot corrosion under salt deposition at elevated temperatures. Here, this study investigates the hot corrosion behavior of 304&P91 GCTJ exposed to sulfate salts at 700°C. Compared to the 304 steel, corrosion attacks initiate in the P91 triangle, where the dual-phase microstructure of ferrite and tempered martensite significantly influences pitting initiation. Anodic dissolution mainly occurs within the tempered martensite due to more vulnerable sites within the tempered martensite. With prolonged exposure, corrosion propagates across both phases, and the corrosion depth within the P91 triangle is related to the exposed surface area ratio between 304 and P91. Electrochemical analysis reveals the occurrence of galvanic corrosion between the 304 and P91, with a positive linear relationship between anodic dissolution current density (I a ) and the exposed surface area ratio between 304 and P91 in molten salts, further emphasizing the critical impact of this ratio on the corrosion severity in the P91 triangle. These findings underscore the importance of transition zone design optimization in mitigating localized corrosion.

Galvanic corrosion↗

Influence of AA6061 surface preparation on the resistance to surface degradation of thermally grown boehmite films

Understanding substrate–coating interactions is crucial for designing durable, corrosion-resistant systems. This study investigates the effects of surface treatments— polishing, acid etching, and alkaline etching—on AA6061 aluminum alloy and its thermally grown boehmite coatings. Surface treatments were found to significantly alter boehmite film properties by modifying the alloy’s surface composition. X-ray photoelectron spectroscopy revealed a 10% alumina drop after acid etching alongside chemisorbed species formation in wet treatments. Structural analysis, including grazing incidence X-ray diffraction and TEM, showed α-Al 2 O 3 formation on polished surfaces, improving wear resistance but inducing cathodic E corr shifts, pointing to higher corrosion susceptibility. In contrast, acid and alkaline etching produced anodic E corr shifts with stable, pit-free films observed via potentiodynamic scans. Electrochemical impedance spectroscopy highlighted reduced oxide resistance with extended boehmite growth. The findings emphasize the role of surface pre-treatments and boehmite optimization in balancing durability and corrosion resistance for AA6061 substrates.

AA6061↗

Corrosion in NiCd cells

Corrosion in the terminals of nickel cadmium cells was investigated. Corrosion, crevice type corrosion, at the interface between the stainless steel material, the nickel material, and the braze was examined. It was concluded that in the welded areas there was no problem. There was corrosion of the crevice type in the brazed areas and some pitting was evident between the braze and the base material.

Badcock, C.↗

pH Sensitive Microcapsules for Delivery of Corrosion Inhibitors

A considerable number of corrosion problems can be solved by coatings. However, even the best protective coatings can fail by allowing the slow diffusion of oxygen and moisture to the metal surface. Corrosion accelerates when a coating delaminates. Often, the problems start when microscopic nicks or pits on the surface develop during manufacturing or through wear and tear. This problem can be solved by the incorporation of a self-healing function into the coating. Several new concepts are currently under development to incorporate this function into a coating. Conductive polymers, nanoparticles, and microcapsules are used to release corrosion-inhibiting ions at a defect site. The objective of this investigation is to develop a smart coating for the early detection and inhibition of corrosion. The dual function of this new smart coating system is performed by pH-triggered release microcapsules. The microcapsules can be used to deliver healing agents to terminate the corrosion process at its early stage or as corrosion indicators by releasing dyes at the localized corrosion sites. The dyes can be color dyes or fluorescent dyes, with or without pH sensitivity. Microcapsules were formed through the interfacial polymerization process. The average size of the microcapsules can be adjusted from 1 to 100 micron by adjusting the emulsion formula and the microcapsule forming conditions. A typical microcapsule size is around 10 microns with a narrow size distribution. The pH sensitivity of the microcapsule can also be controlled by adjusting the emulsion formula and the polymerization reaction time. Both corrosion indicator (pH indicator) and corrosion inhibitor containing microcapsules were formed and incorporated into paint systems. Test panels of selected steels and aluminum alloys were painted using these paints. Testing of compatibility between the microcapsule system and different paint systems are in progress. Initial experiments with the microcapsule containing paint show visible color changes at induced corrosion sites and improvement of corrosion protection. Further investigation of the performance of the coating using electrochemical techniques and long term exposure are currently underway.

Li, Wenyan↗

Effects of processing temperature on the corrosion and tribocorrosion resistance of perhydropolysilazane-derived coatings on AISI 304 steel

Ensuring a highly corrosion and erosion resistant surface is critical to the reliability and structural integrity of steel canisters for long-term nuclear waste storage in corrosive environments. In this work, perhydropolysilazane (PHPS)-derived coating has been successfully applied to enhance the pitting and tribocorrosion resistance of 304 stainless steels in 0.6 M NaCl solution. Two types of coatings were synthesized on the stainless steel substrate by crosslinking PHPS at room temperature or 600 °C, resulting in different mechanical and corrosion performance. Further, Raman spectra revealed that Si-O bonds were generated in the coating crosslinked at room temperature after corrosion, while absent in that pyrolyzed at 600 °C. In tribocorrosion tests, both coatings were protective to the steel substrate, with the protective effect being more pronounced in the 600 °C pyrolyzed coating. Overall, the PHPS-derived coating synthesized at 600 °C exhibited better protection for steel in wear and corrosion coexisting environments than those synthesized at room temperature.

36 MATERIALS SCIENCE↗