Search NASA⌕ Search

SEARCH · Search NASA

Results for “Parallel connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Standard arc welders provide high amperage direct current source

Standard arc welders or power supplies are hooked up in parallel or series connections to obtain an adequate supply of current or voltage for various purposes. This method provides maximum flexibility in a wide range of voltages and currents.

Beasley, W. D.↗

REDOX electrochemical energy storage

Reservoirs of chemical solutions can store electrical energy with high efficiency. Reactant solutions are stored outside conversion section where charging and discharging reactions take place. Conversion unit consists of stacks of cells connected together in parallel hydraulically, and in series electrically. Stacks resemble fuel cell batteries. System is 99% ampere-hour efficient, 75% watt hour efficient, and has long projected lifetime. Applications include storage buffering for remote solar or wind power systems, and industrial load leveling. Cost estimates are $325/kW of power requirement plus $51/kWh storage capacity. Mass production would reduce cost by about factor of two.

Thaller, L. H.↗

Improvement and scale-up of the NASA Redox storage system

A preprototype full-function 1.0 kW Redox system (2 kW peak) with 11 kW storage capacity has been built and integrated with the NASA/DOE photovoltaic test facility. The system includes four substacks of 39 cells each (1/3 sq ft active area) which are connected hydraulically in parallel and electrically in series. An open circuit voltage cell and a set of rebalance cells are used to continuously monitor the system state of charge and automatically maintain the anode and cathode reactants electrochemically in balance. Technological advances in membrane and electrodes and results of multicell stack tests are reviewed.

Reid, M. A.↗

Improvement and scale-up of the NASA Redox storage system

A preprototype 1.0 kW redox system (2 kW peak) with 11 kWh storage capacity was built and integrated with the NASA/DOE photovoltaic test facility at NASA Lewis. This full function redox system includes four substacks of 39 cells each (1/3 cu ft active area) which are connected hydraulically in parallel and electrically in series. An open circuit voltage cell and a set of rebalance cells are used to continuously monitor the system state of charge and automatically maintain the anode and cathode reactants electrochemically in balance. Recent membrane and electrode advances are summarized and the results of multicell stack tests of 1 cu ft are described.

Reid, M. A.↗

Sequential deployment of truss structures

The geometry investigated most intensively was the triangular tetrahedral truss. A square type truss having the same topology was also investigated. The tetrahedral truss is composed of surface struts and core members. In the deployable form, the entire truss is viewed as being made up of a number of parallel truss ribs connected to each other by interrib struts and members. The packaging efficiency of the truss was evaluated.

Hedgebeth, J. M.↗

The MOLICEL(R) rechargeable lithium system: Multicell battery aspects

MOLICEL rechargeable lithium cells were cycled in batteries using series, parallel, and series/parallel connections. The individual cell voltages and branch currents were measured to understand the cell interactions. The observations were interpreted in terms of the inherent characteristics of the Li/MoS2 system and in terms of a singular cell failure mode. The results confirm that correctly configured multicell batteries using MOLICELs have performance characteristics comparable to those of single cells.

Fouchard, D.↗

In search of the elusive flow field

A specific set of problems must be overcome before an optical flow field can be derived from an image sequence. These problems are discussed and an outline of a scheme for overcoming these obstacles is presented. A two-dimensional motion sensor is presented which is capable of measuring edge velocity in twelve separate directions at any point in the image. However, because of the aperture problem, the sensors can only determine the velocity component in the direction orthogonal to the edge. A second stage which uses a cosine-weighted voting scheme is used to derive the true flow field from the edge velocities. The whole system is based on a parallel network of connections and weights and is potentially a very fast method of obtaining the two-dimensional flow field.

Perrone, John A.↗

The composition of concurrent programs

A notation is presented for concurrent programs called program composition notation (PCN). The notation is being implemented at Caltech on multicomputers (a network of computers that communicate by sending and receiving messages). A fragment of this notation has been implemented on a data-parallel computer, the Connection Machine. The central ideas underlying PCN are discussed.

Chandy, K. Mani↗

Tailorable advanced blanket insulation using aluminoborosilicate and alumina batting

Two types of Tailorable Advanced Blanket Insulation (TABI) flat panels for Advanced Space Transportation Systems were produced. Both types consisted of integrally woven, 3-D fluted core having parallel faces and connecting ribs of Nicalon yarns. The triangular cross section flutes of one type was filled with mandrels of processed Ultrafiber (aluminoborosilicate) stitchbonded Nextel 440 fibrous felt, and the second type wall filled with Saffil alumina fibrous felt insulation. Weaving problems were minimal. Insertion of the fragile insulation mandrels into the fabric flutes was improved by using a special insertion tool. An attempt was made to weave fluted core fabrics from Nextel 440 yarns but was unsuccessful because of the yarn's fragility. A small sample was eventually produced by an unorthodox weaving process and then filled with Saffil insulation. The procedures for setting up and weaving the fabrics and preparing and inserting insulation mandrels are discussed. Characterizations of the panels produced are also presented.

Calamito, Dominic P.↗

Balancing Contention and Synchronization on the Intel Paragon

The Intel Paragon is a mesh-connected distributed memory parallel computer. It uses an oblivious and deterministic message routing algorithm: this permits us to develop highly optimized schedules for frequently needed communication patterns. The complete exchange is one such pattern. Several approaches are available for carrying it out on the mesh. We study an algorithm developed by Scott. This algorithm assumes that a communication link can carry one message at a time and that a node can only transmit one message at a time. It requires global synchronization to enforce a schedule of transmissions. Unfortunately global synchronization has substantial overhead on the Paragon. At the same time the powerful interconnection mechanism of this machine permits 2 or 3 messages to share a communication link with minor overhead. It can also overlap multiple message transmission from the same node to some extent. We develop a generalization of Scott's algorithm that executes complete exchange with a prescribed contention. Schedules that incur greater contention require fewer synchronization steps. This permits us to tradeoff contention against synchronization overhead. We describe the performance of this algorithm and compare it with Scott's original algorithm as well as with a naive algorithm that does not take interconnection structure into account. The Bounded contention algorithm is always better than Scott's algorithm and outperforms the naive algorithm for all but the smallest message sizes. The naive algorithm fails to work on meshes larger than 12 x 12. These results show that due consideration of processor interconnect and machine performance parameters is necessary to obtain peak performance from the Paragon and its successor mesh machines.

Bokhari, Shahid H.↗

Low Differential Pressure Generator

A method and apparatus for evaluating low differential pressure transducers includes a pressure generator in the form of a piston-cylinder assembly having a piston that may be manually positioned precisely within the cylinder to change the volume and thus the pressure at respective sides of the piston. At one side of the piston the cylinder communicates with a first chamber and at the other side of the piston the cylinder communicates with a second chamber, the first and second chambers being formed within a common tank by a partition wall. The chambers each communicate with the transducer to be evaluated and a standard pre-calibrated transducer the transducers being connected fluidly in parallel so that a pressure differential between air in the two chambers resulting from movement of the piston within the cylinder is communicated to both the transducer to be evaluated and the standard transducer, and the outputs of the transducers is observed and recorded.

Stout, Stephen J.↗

A Computational Fluid Dynamics Algorithm on a Massively Parallel Computer

The discipline of computational fluid dynamics is demanding ever-increasing computational power to deal with complex fluid flow problems. We investigate the performance of a finite-difference computational fluid dynamics algorithm on a massively parallel computer, the Connection Machine. Of special interest is an implicit time-stepping algorithm; to obtain maximum performance from the Connection Machine, it is necessary to use a nonstandard algorithm to solve the linear systems that arise in the implicit algorithm. We find that the Connection Machine ran achieve very high computation rates on both explicit and implicit algorithms. The performance of the Connection Machine puts it in the same class as today's most powerful conventional supercomputers.

Jespersen, Dennis C.↗

Method and apparatus for multiplexing switch signals

Apparatus for multiplexing switch state signals comprises a plurality of switches and parallel weighted resistors connected in series between circuit ground and a node at a utilization device. The resistors are weighted as a function of a power of the same base, such as the power of the base 2, for coding the multiplexed switch state signals. A constant current source connected between the node and circuit ground drives current over a single cable conductor through the resistor. Each switch may be independently closed to change the switch state voltage signals multiplexed to the node. An analog-to-digital converter connected between the node and circuit ground demultiplexes the switch state signals received at the node and provides a switch state signal at each analog-to-digital output corresponding to the state of the switches at the moment. A potentiometer may replace a resistor and bypass switch combination in a position where the potentiometer has a maximum value of the lowest power of the base in order to multiplex a true analog voltage signal while switch state signals are unambiguously coded and multiplexed. The potentiometer in the least significant position permits the analog value to be in the range from 0 to a maximum corresponding to the least significant position of the switch state encoding. The invention may be used in redundancy systems by duplicating the invention with corresponding switches in each duplication ganged to open and close simultaneously upon operation of a pushbutton switch.

Hannaford, Blake↗

Hybrid interconnection structures for real-time parallel processing

The use of hybrid interconnection structures that combine link connections and bus connections for real-time parallel processing is discussed. Idealistic parallel computation models for two real-time computing applications are described with attention given to a tightly coupled network model for object tracking and a network model for image processing. Consideration is given to the following different interconnection structures: the crossbar, the hypercube, the circular linked array, and the bus array.

Kim, K. H.↗

Control of Dual-Opposed Stirling Convertors with Active Power Factor Correction Controllers

When using recently-developed active power factor correction (APFC) controllers in power systems comprised of dual-opposed free-piston Stirling convertors, a variety of configurations of the convertors and controller(s) can be considered, with configuration ultimately selected based on benefits of efficiency, reliability, and robust operation. The configuration must not only achieve stable control of the two convertors, but also synchronize and regulate motion of the pistons to minimize net dynamic forces. The NASA Glenn Research Center (GRC) System Dynamic Model (SDM) was used to study ten configurations of dual-opposed convertor systems. These configurations considered one controller with the alternators connected in series or in parallel, and two controllers with the alternators not connected (isolated). For the configurations where the alternators were not connected, several different approaches were evaluated to synchronize the two convertors. In addition, two thermodynamic configurations were considered: two convertors with isolated working spaces and convertors with a shared expansion space. Of the ten configurations studied, stable operating modes were found for four. Three of those four had a common expansion space. One stable configuration was found for the dual-opposed convertors with separate working spaces. That configuration required isochronous control of both convertors, and two APFC controllers were used to accomplish this. A frequency/phase control loop was necessary to allow each APFC controller to synchronize its associated convertor with a common frequency.

Regan, Timothy F.↗

Control of Dual-Opposed Stirling Convertors with Active Power Factor Correction Controllers

When using recently-developed active power factor correction (APFC) controllers in power systems comprised of dual-opposed free-piston Stirling convertors, a variety of configurations of the convertors and controller(s) can be considered, with configuration ultimately selected based on benefits of efficiency, reliability, and robust operation. The configuration must not only achieve stable control of the two convertors, but also synchronize and regulate motion of the pistons to minimize net dynamic forces. The NASA Glenn Research Center (GRC) System Dynamic Model (SDM) was used to study ten configurations of dual-opposed convertor systems. These configurations considered one controller with the alternators connected in series or in parallel, and two controllers with the alternators not connected (isolated). For the configurations where the alternators were not connected, several different approaches were evaluated to synchronize the two convertors. In addition, two thermodynamic configurations were considered: two convertors with isolated working spaces and convertors with a shared expansion space. Of the ten configurations studied, stable operating modes were found for four. Three of those four had a common expansion space. One stable configuration was found for the dual-opposed convertors with separate working spaces. That configuration required isochronous control of both convertors, and two APFC controllers were used to accomplish this. A frequency/phase control loop was necessary to allow each APFC controller to synchronize its associated convertor with a common frequency.

Regan, Timothy F.↗

Memory-based frame synchronizer

A frame synchronizer for use in digital communications systems wherein data formats can be easily and dynamically changed is described. The use of memory array elements provide increased flexibility in format selection and sync word selection in addition to real time reconfiguration ability. The frame synchronizer comprises a serial-to-parallel converter which converts a serial input data stream to a constantly changing parallel data output. This parallel data output is supplied to programmable sync word recognizers each consisting of a multiplexer and a random access memory (RAM). The multiplexer is connected to both the parallel data output and an address bus which may be connected to a microprocessor or computer for purposes of programming the sync word recognizer. The RAM is used as an associative memory or decorder and is programmed to identify a specific sync word. Additional programmable RAMs are used as counter decoders to define word bit length, frame word length, and paragraph frame length.

Stattel, R. J.↗

Ongoing data reduction, theoretical studies and supporting research in magnetospheric physics

Data from ISEE-3, Pioneer Venus Orbiter, and Voyager 1 and 2 were analyzed. The predictability of local shock macrostructure at ISEE-1, at the Earth's bow shock, from solar wind measurements made up-stream by ISEE-3, was conducted using computer graphic format. Morphology of quasi-parallel shock was reviewed. The review attempted to interrelate various measurements and computations involving the q-parallel structure and foreshock elements connected to it. A new classification for q-parallel morphology was suggested.

Scarf, F. L.↗