Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Current system in an auroral substorm

An instrumented sounding rocket was launched at 0040 LT into the expansive phase of an auroral substorm on March 16, 1973, from Poker Flat, Alaska. This report describes coordinated measurements of electric field, magnetic field, and energetic electrons. By comparing the observed magnetic field with that predicted by model currents, a current system, which includes field-aligned currents, is deduced. The model indicates three currents: a southward current, a westward current, and two field-aligned currents. A southward electric field of 60 mV/m identifies the southward current as a Pedersen current and the westward current as a Hall current. The field-aligned current measured from particle detectors shows a structure similar to that in the magnetic model. The total field-aligned electron current measured by particle detectors agrees within 10% of the current model.

Kintner, P. M.↗

Transient current induced in thin film diamonds by swift heavy ions

Single crystal diamond is a suitable material for the next generation particle detectors because of the superior electrical properties and the high radiation tolerance. In order to investigate charge transport properties of diamond particle detectors, transient currents generated in diamonds by single swift heavy ions (26 MeV O 5 + and 45 MeV Si 7 + ) are investigated. We also measured two dimensional maps of transient currents by single ion hits. In the case of 50 μm-thick diamond, both the signal height and the collected charge are reduced by the subsequent ion hits and the charge collection time is extended. Our results are thought to be attributable to the polarization effect in diamond and it appears only when the transient current is dominated by hole current. In the case of 6 μm-thick diamond membrane, an “island” structure is found in the 2D map of transient currents. Signals in the islands shows different applied bias dependence from signals in other regions, indicating different crystal and/or metal contact quality. Simulation study of transient currents based on the Shockley-Ramo theorem clarifies that accumulation of space charges changes distribution of electric field in diamond and causes the polarization effect.

36 MATERIALS SCIENCE↗

Prototype detectors for the Deep Underground Neutrino Experiment

The international Deep Underground Neutrino Experiment, hosted by Fermilab, will investigate the role neutrinos play in the universe. To test the technologies used by DUNE, scientists are building two large prototype detectors at CERN. Filled with 800 tons of liquid argon, the ProtoDUNE detectors are the largest particle detectors of their kind. The actual DUNE detector modules, which will be assembled 1.5 kilometers underground at the Sanford Underground Research Facility, will be 20 times bigger than these test beds. More than 1,000 scientists from research institutions in 32 countries are working on DUNE. On Sept. 18, 2018, DUNE scientists announced the observation of the first particle tracks with the first of the two prototype detectors: https://news.fnal.gov/2018/09/first-tracks-in-prototype-for-neutrino-experiment/

42 ENGINEERING↗

Impact of proton irradiation on 4H-SiC Low Gain Avalanche Detectors (LGADs)

Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and complementary PiN diodes were irradiated with 2.5 GeV protons at fluences up to 3.33 × 10 14 p/cm 2 . The electrostatic performance of both irradiated and non-irradiated devices was evaluated using I-V and C-V measurements. Moreover, charge collection measurements using α particles were also conducted. SiC LGADs displayed a loss in rectification, high ON-state resistances >10 10 Ω-cm 2 , and the complete removal of gain when exposed to the highest proton fluence. Additionally, the reductions in capacitance and OFF-state current pointed to compensation of the gain layer as a gain reducing mechanism. The introduction of radiation-induced defects also hinders carrier acceleration, which reduces impact ionization and further gain reduction. LGADs exposed to a fluence of 1 × 10 14 p/cm 2 experienced a partial recovery in gain (originally having a value of ∼ 2) with a value of ∼ 1.65 when applying a bias of 500 V. Charge trapping was also seen in the reduction of charge collection efficiency (CCE) to ∼ 65% for the PiN diode. However, despite the reduction in device performance, the demonstration of a measurable signal after irradiation points to the potential of SiC LGAD detectors for future high energy physics applications.

43 PARTICLE ACCELERATORS↗

Lateral distribution of pulse height in a parallel-plate avalanche counter

The nuclear γ-ray spectroscopy enters a new era when the first engineering run of GRETINA [1], a new generation of γ-ray tracking arrays, was successfully carried out at LBNL in early April, 2011. A parallel effort has been setup to develop the auxiliary charged-particle detector arrays with a matching position resolution to fully exploit the potential of GRETINA. Improving the position resolution of the existing charged-particle detector array, CHICO [2], is a part of this coordinated effort. The proposal to upgrade CHICO was approved by DOE/SC at the end of FY10. The goal is to redesign the cathode board and amplifier to improve the resolution for both and coordinates to better than one degree to match that of GRETINA. This project is scheduled to complete by the summer of 2012.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic Field Tolerant Large Area Picosecond Photon Detectors for Particle Identification (Phase I Final Report)

Incom is reporting on success in its DOE SBIR Phase I feasibility demonstration of our ability to optimize and characterize the magnetic field insensitivity of Large Area Picosecond Photon Detectors (LAPPDs) which we manufacture, this was accomplished principally by decreasing MCP pore sizes. LAPPDs are cost-effective ultra-high time precision imaging quantum photodetectors that incorporate Incom’s unique large-area ALD- (Atomic Layer Deposition) GCA- (Glass Capillary Array) MCPs (Microchannel Plates). Several applications of LAPPDs, including for potential upgrades to existing DoE NP detectors or as part of proposed designs for future DoE NP experiments (including at the future EIC Electron Ion Collider) will require LAPPD operation in strong magnetic fields. We are improving and verifying the performance of LAPPDs in strong magnetic fields both by modifying their internal construction and most importantly by modifying their constituents by using smaller-pore MCPs; we and others have shown that this improves magnetic field insensitivity in MCP-PMTs like our LAPPD. We have begun a series of magnetic field tests at Argonne National Laboratory on 6 x 6cm MCP-PMTs constructed at ANL using Incom MCPs, and on 20 x 20cm LAPPDs constructed at Incom again using Incom MCPs, each in a series of devices containing MCPs of ever smaller pore diameters, from 20μ to 10μ to 5μ; in addition to improving magnetic field insensitivity, smaller pores will improve LAPPD timing and thus benefit physics performance in future DoE NP detectors, including at the EIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Virtual Walk: The Construction of the Long Baseline Neutrino Facility

This 2-minute animation shows a virtual walk through the large caverns of the Long-Baseline Neutrino Facility, which will house the Deep Underground Neutrino Experiment. To create the caverns for the huge DUNE particle detectors, construction crews will excavate more than 800,000 tons of rock a mile underground at the Sanford Underground Research Facility in South Dakota. Scientists and dignitaries broke ground for this project on July 21, 2017. When construction is complete, DUNE scientists will send an intense neutrino beam through 1,300 kilometers of rock from the Department of Energy’s Fermilab to the DUNE particle detectors to understand the role that neutrinos – the most abundant matter particles in the universe – play in our cosmos. About 1,000 scientists from more than 160 institutions in 30 countries work on the Deep Underground Neutrino Experiment.

42 ENGINEERING↗

Profiling of the injected charge drift current transients by cross-sectional scanning technique

The electric field distribution and charge drift currents in Si particle detectors are analyzed. Profiling of the injected charge drift current transients has been implemented by varying charge injection position within a cross-sectional boundary of the particle detector. The obtained profiles of the induction current density and duration of the injected charge drift pulses fit well the simulated current variations. Induction current transients have been interpreted by different stages of the bipolar and monopolar drift of the injected carriers. Profiles of the injected charge current transients registered in the non-irradiated and neutron irradiated Si diodes are compared. It has been shown that the mixed regime of the competing processes of drift, recombination, and diffusion appears in the measured current profiles on the irradiated samples. The impact of the avalanche effects can be ignored based on the investigations presented. It has been shown that even a simplified dynamic model enabled us to reproduce the main features of the profiled transients of induced charge drift current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Hard Silicon for Medical, Space and High Energy Physics Applications

The objective of this paper is to give an overview on how silicon particle detector would survive operational in extremely harsh radiation environment after luminosity upgrade of the CERN LHC (Large Hadron Collider). The Super-LHC would result in an integrated fluence 1 x 10{sup 16} p/cm{sup 2} and that is well beyond the radiation tolerance of even the most advanced semiconductor detectors fabricated by commonly adopted technologies. The Czochralski silicon (Cz-Si) has intrinsically high oxygen concentration. Therefore Cz-Si is considered as a promising material for the tracking systems in future very high luminosity colliders. The fabrication process issues of Cz-Si are discussed and the formation of thermal donors is especially emphasized. N{sup +}/p{sup -}/p{sup +} and p{sup +}/n{sup -}/n{sup +} detectors have been processed on magnetic Czochralski (MCz-Si) wafers. We show measurement data of AC-coupled strip detectors and single pad detectors as well as experimental results of intentional TD doping. Data of spatial homogeneity of electrical properties, full depletion voltage and leakage current, is shown and n and p-type devices are compared. Our results show that it is possible to manufacture high quality n{sup +}/p{sup -}/p{sup +} and p{sup +}/n{sup -}/n{sup +} particle detectors from high resistivity Czochralski silicon.

43 PARTICLE ACCELERATORS↗

Measuring time of flight of fusion products in an inertial electrostatic confinement fusion device for spatial profiling of fusion reactions

A new diagnostic has been developed that uses the time of flight (TOF) of the products from a nuclear fusion reaction to determine the location where the fusion reaction occurred. The TOF diagnostic uses charged particle detectors on opposing sides of the inertial electrostatic confinement (IEC) device that are coupled to high resolution timing electronics to measure the spatial profile of fusion reactions occurring between the two charged particle detectors. This diagnostic was constructed and tested by the University of Wisconsin-Madison Inertial Electrostatic Confinement Fusion Group in the IEC device, HOMER, which accelerates deuterium ions to fusion relevant energies in a high voltage ({approx}100 kV), spherically symmetric, electrostatic potential well [J. F. Santarius, G. L. Kulcinski, R. P. Ashley, D. R. Boris, B. B. Cipiti, S. K. Murali, G. R. Piefer, R. F. Radel, T. E. Radel, and A. L. Wehmeyer, Fusion Sci. Technol. 47, 1238 (2005)]. The TOF diagnostic detects the products of D(d,p)T reactions and determines where along a chord through the device the fusion event occurred. The diagnostic is also capable of using charged particle spectroscopy to determine the Doppler shift imparted to the fusion products by the center of mass energy of the fusion reactants. The TOF diagnostic is thus able to collect spatial profiles of the fusion reaction density along a chord through the device, coupled with the center of mass energy of the reactions occurring at each location. This provides levels of diagnostic detail never before achieved on an IEC device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of Particle Physics

The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 2,873 new measurements from 758 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Here, among the 118 reviews are many that are new or heavily revised, including a new review on Neutrinos in Cosmology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Review of Particle Physics - Scalar Mesons below 1 GeV

The summarizes much of particle physics and cosmology. Using data from previous editions, plus 2,717 new measurements from 869 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Most of the 120 reviews are updated, including many that are heavily revised. The is divided into two volumes. Volume 1 includes the Summary Tables and 97 review articles. Volume 2 consists of the Particle Listings and contains also 23 reviews that address specific aspects of the data presented in the Listings. The complete (both volumes) is published online on the website of the Particle Data Group () and in a journal. Volume 1 is available in print as the . A with the Summary Tables and essential tables, figures, and equations from selected review articles is available in print, as a web version optimized for use on phones, and as an Android app. The 2024 edition of the Review of Particle Physics should be cited as: S. Navas et al. (Particle Data Group), Phys. Rev. D 110, 030001 (2024)© 20242024

Navas, S. [Universidad de Granada]↗

Review of particle physics

This biennial Review summarizes much of particle physics. Using data from previous editions, plus 2158 new measurements from 551 papers, we list, evaluate, and average measured properties of gauge bosons, leptons, quarks, mesons, and baryons. We al so summarize searches for hypothetical particles such as Higgs bosons, heavy neutrinos, and supersymmetric particles. All the particle properties and search limits are listed in Summary Tables. We also give numerous tables, figures, formulae, and reviews of topics such as the Standard Model, particle detectors, probability, and statistics. Among the 108 reviews are many that are new or heavily revised including those on neutrino mass, mixing, and oscillations, QCD, top quark, CKM quark-mixing matrix, V(ud ) & V(us), V(cb) & V(ub), fragmentation functions, particle detectors for accelerator and non-accelerator physics, magnetic monopoles, cosmological parameters, and big bang cosmology. A booklet is available containing the Summary Tables and abbreviated ve rsions of some of the other sections of this full Review. All tables, listings, and reviews (and errata) are also available on the Particle Data Group website: pdg.lbl.gov.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The particle-gamma coincidence method: A brief introduction

Excitation energy information from particle detectors can significantly improve the analysis process of {gamma}-ray spectra and result in more detailed nuclear structure information. Therefore, a new setup at the HORUS {gamma}-ray spectrometer at the University of Cologne has been installed, housing silicon particle detectors at up to eight positions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

12 GeV detector technology at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) is presently in the middle of an upgrade to increase the energy of its CW electron beam from 6 GeV to 12 GeV along with the addition of a fourth experimental hall. Driven both by necessity and availability, novel detectors and electronics modules have been used in the upgrade. One such sensor is the Silicon Photomultiplier (SiPM), specifically a Multi-Pixel Photon Counter (MPPC), which is an array of avalanche photodiode pixels operating in Geiger mode that are used to sense photons. The SiPMs replace conventional photomultiplier tubes and have several distinct advantages including the safe operation in a magnetic field and the lack of need for high voltage. Another key to 12 GeV success is advanced fast electronics. Jlab will use custom 250 MHz and 125 MHz 12-bit analog to digital converters (ADCs) and time to digital converters (TDCs) all of which take advantage of VME Switched Serial (VXS) bus with its GB/s high bandwidth readout capability. These new technologies will be used to readout drift chambers, calorimeters, spectrometers and other particle detectors at Jlab once the 12 GeV upgrade is complete. The largest experiment at Jlab utilizing these components is GlueX - an experiment in the newly constructed Hall D that will study the photoproduction of light mesons in the search for hybrid mesons. The performance of these components and their respective detectors will be presented.

43 PARTICLE ACCELERATORS↗

Detection of atomic and molecular mega-electron-volt projectiles using an x-ray charged coupled device camera

We show that an x-ray charge coupled device (CCD) may be used as a particle detector for atomic and molecular mega-electron-volt (MeV) projectiles of around a few hundred keV per atomic mass unit. For atomic species, spectroscopic properties in kinetic energy measurements (i.e., linearity and energy resolution) are found to be close to those currently obtained with implanted or surface barrier silicon particle detectors. For molecular species, in order to increase the maximum kinetic energy detection limit, we propose to put a thin foil in front of the CCD. This foil breaks up the molecules into atoms and spreads the charges over many CCD pixels and therefore avoiding saturation effects. This opens new perspectives in high velocity molecular dissociation studies with accelerator facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress Towards Correlating Qubit Relaxation Events with Cosmic Rays

We implement Superconducting Qubits, and explore their capabilities as particle detectors. Our goal is to understand how qubits respond to cosmic ray interactions in the device substrate. In particular, we aim to improve the understanding of the underlying physics that causes relaxation. Future work aims to further develop this understanding, and leverage it to improve the sensitivity of qubit-based particle detectors. By using a set of scintillating paddles, we study the impact of cosmic rays in a substrate.

79 ASTRONOMY AND ASTROPHYSICS↗