Development of CFD Flow Analysis for Nuclear Facility Ventilation Systems

Understanding and modeling of particulate transport has importance related to safety in ventilated environments that contain hot cells, gloveboxes, and fume hoods. In particular, good modeling of the airflow in these spaces is required to understand areas of stagnation where particles drop out of the free stream and accumulate. This accumulation of particulate can cause either contamination and/or higher than acceptable local dose levels. It is known that multiple sites across the DOE complex take credit for hot cells, gloveboxes, and/or hoods in their safety basis for providing a defense-in-depth benefit for both onsite and offsite releases. By providing confinement of radioactive materials, such features serve to reduce direct doses to facility workers and mitigate the consequences to the environment due to an uncontrolled release. Each of these features has access points that interface with the personnel space. Understanding how air flow behaves at these access points is of great interest to those performing hazard analysis. Computational Fluid Dynamics (CFD) can be used to analyze and model the flows in hot cells and glove boxes as a way to confirm operation. While CFD capability continues to advance, there are still important modeling assumptions that are left to the analyst's discretion. These are most notably the choice of the turbulence models, mesh structure, and wall boundary condition assumptions used in the model. In this work, we apply CFD in modeling airflow through an occupiable work area of the Alpha Gamma Hot Cell Facility (AGHCF) at Argonne National Laboratory (ANL). This modeling is then compared to field test data to both inform and verify the modeling assumptions. Based on the results of field tests, modeling assumptions and boundary conditions are refined and the process is repeated until the results are found to be reliable with a high level of confidence.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Contamination control program for the Extreme Ultraviolet Explorer instruments

A contamination-control program has been instituted for the optical components of the EUV Explorer satellite, whose 80-900 A range performance is easily degraded by particulate and molecular contamination. Cleanliness requirements have been formulated for the design, fabrication, and test phases of these instruments; in addition, contamination-control steps have been taken which prominently include the isolation of sensitive components in a sealed optics cavity. Prelaunch monitoring systems encompass the use of quartz crystal microbalances, particle witness plates, direct flight hardware sampling, and optical witness sampling of EUV scattering and reflectivity.

Ray, David C.↗

Implementation of the TOMS contamination control requirements in the former USSR

The American Total Ozone Mapping Spectrometer (TOMS) was integrated with the Russian Meteor-3 spacecraft and launched on August 15, 1991. Although the TOMS instrument was sensitive to both particulate and molecular contamination, the program for Meteor-3 had not formerly addressed contamination control in ground operations. In order to accommodate the TOMS cleanliness requirements, a contamination control program was successfully established from inception at both the Meteor-3 spacecraft plant near Moscow and at the launch site in Plesetsk.

Abrams, Eve M.↗

Contamination control program results from three years of ground operations on the Extreme Ultraviolet Explorer instruments

A stringent contamination-control plan has been developed for the optical components of the Extreme Ultraviolet Explorer instruments, whose performance in the 80-900 A wavelength range is highly sensitive to particulate and molecular contamination. The contamination-control program has been implemented over the last three years during assembly, test and calibration phases of the instrument. These phases have now been completed and the optics cavities of the instruments have been sealed until deployment in space. Various approaches are discussed which have been used during ground operations to meet optics' contamination goals within the project schedule and budget. The measured optical properties of EUV witness mirrors are also presented which remained with the flight mirrors during ground operations. These were used to track optical degradation due to contamination from the cleanroom and high-vacuum test-chamber environments.

Ray, David C.↗

Preparation, verification, and operational control of a large space-environment-simulation chamber for contamination sensitive tests

A 2-year program to prepare chamber A at the NASA Manned Spacecraft Center for Apollo telescope mount thermal-vacuum tests is discussed. This program covers modification to existing chamber systems, the development of facility and chamber operating procedures, the selection of chamber cleaning and control methods, and the development and evaluation of diagnostic instrumentation. Extensive efforts to ensure a minimum contamination environment for the Apollo telescope mount test series are illustrated. Recent thermal-vacuum tests of this chamber at progressive stages of cleanliness have demonstrated the success achieved in reducing the particulate and molecular contamination levels of the basic chamber interior.

Visentine, J. T.↗

Contamination design of a Scientific Instrument Protective Enclosure for the Hubble Space Telescope Servicing Mission

A Scientific Instrument Protective Enclosure (SIPE) was designed to accommodate second generation science instruments (SIs) for the Hubble Space Telescope (HST) First Servicing Mission (FSM). One of the main design drivers for the SIPE is to provide a protective environment for the SIs against particulate and molecular contaminants that pose a viable threat to the SI performance. The focus of this paper will detail the methodology incorporated in the design of the SIPE to provide a controlled environment for SI protection at the launch site, during pre-launch/launch activities, and during on-orbit operations in the Shuttle bay.

Hedgeland, Randy J.↗

A Study of Space Station Contamination Effects

A workshop was held with the specific objective of reviewing the state-of-knowledge regarding Space Station contamination, the extent to which the various categories of contamination can be predicted, and the extent to which the predicted levels would interfere with onboard scientific investigations or space station functions. The papers presented at the workshop are compiled and address the following topics: natural environment, plasma electromagnetic environment, optical environment, particulate environment, spacecraft contamination, surface physics processes, laboratory experiments and vented chemicals/contaminants.

Torr, M. R.↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FX2 advanced fogging technology - 15711

Problem statement: The need for an advanced technology that can better address potential airborne contaminants at DOE Savannah River Site 235-F. Current methods of knocking down or fixing this contamination are labor intensive, costly, and sometimes ineffective. Thus, to make exposure ALARA, the advanced fogging effort is being tested using Idaho National Laboratory's FX2 fixative agent. The FX2 fogging agent is a proprietary mixture of water, latex paint (LTX), glycerin (GLY) and sodium lauryl sulfate (SLS). Initial development began in 2006 when a DOE Small Business Innovative Research (SBIR) grant resulted in the development of a conceptual advanced capture coating fog system. This coating is shown to be excellent at reducing airborne contamination and 'fixing' particulates in place as demonstrated by Idaho National Lab. Controlling Potential Airborne Particulates: Testing capacity to knockdown airborne particulates. Evaluating ability to fix to different surfaces (e.g., glass, wood, steel, concrete, brick). Line of sight as well as non-line of sight (shadowed) locations will be tested for coverage. Adhesiveness and Coverage of Surface Area: Contact area will be placed under air pressure to attempt dislodging of dried mixture. Particle analysis utilizing ImageJ will be conducted to determine quantifiable coverage. Ignitability: Observation of the FX2's reactivity to flame and heat sources as it is being applied. Results will provide useful information for the prevention of potential hazards. Determine Shielding Properties Against Alpha Sources: Determine the shielding abilities of the FX2. Fogging agent against an alpha particle emitting point source. Evaluating Critical Properties: These properties will be evaluated to better characterize the FX2 and allow for optimal understanding of results: ASTM E1354 - Burn Rate; NFPA 296-Flashover; ASTM D2196 - Viscosity; ASTM D1331 - Surface Tension; ASTM D792 - Density. Testing Innovations: Developed by the National Institutes of Health, ImageJ is a public domain image processing program that allows for the analysis that this effort requires. Coverage: Through contrast analysis, ImageJ can be used to determine the coverage of the agent upon any of the testing surfaces. Correlations: With the feature of coverage evaluation, a relationship, and thus a graphical representation, can be made between surface coverage and radiation shielding. Future work: Engineering and manufacturing of mobile robotic fogging device. ASTM WK5394: establishing performance specifications for stabilizers to minimize migration of dispersible radioactive contamination.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Kinetic Model of the Long-Term Corrosion of Glass-Ceramic Materials

Multiphase waste forms show promise for increased waste loading and for the ability to dispose of contaminated solid and particulate waste through direct densification. However, achieving predictive capability for long-term durability of multiphase waste forms, and thus assessing their possible deployment, requires expanding the current, limited knowledge base. Here, we describe the development of a corrosion model of a two-phase waste form consisting of crystals of known volume fraction embedded in a glass matrix. This model accounts for the dissolution of both the crystalline and glass phases as well as the hydration of the glass phase through an ion exchange reaction. Because of the large difference in solubility between the two phases, the reactive surface of the crystalline phase is a function of the extent of dissolution of the glass phase in this model. Model parameterization was performed using corrosion data, such as from single-pass flow-through tests, for the individual phases. The parameterized corrosion model was evaluated against static dissolution test data for a glass-ceramic multiphase waste form. This evaluation demonstrated the model’s ability to reproduce the time-dependent release of key tracers of glass and crystalline phase dissolution. Hence, the development of a kinetic model provides a pathway for long-term durability predictions and thus the use of multiphase waste forms in nuclear cleanup missions.

Kerisit, Sebastien N.↗

Ionic liquid mediated one-step perpendicular assembly in block copolymer thin films for ultrafiltration membrane applications

The rapid rise of oil and gas, petrochemical, food processing, and pharmaceutical industries has added a complex mixture of contaminants like oil, particulates, metals, and other organic compounds to wastewater. Multipurpose membranes with precise pore structure can offer a solution to this problem and block copolymers (BCP) can be used to achieve such structures. Achieving vertical assembly of BCP domains provides a perfect template for developing uniform through film channels for separation and transport of material, besides being useful for the rectification of defects in photolithography patterns. Producing such morphologies may require extensive film/substrate processing and is not always feasible for scale-up. With this article, we demonstrate a facile solution casting method to induce vertical domain assembly in as-cast diblock copolymer thin films in the presence of an ionic liquid (IL) additive that preferentially segregates to one block and neutralizes interfacial interactions. We also show the tunability of domain sizes by controlling the additive concentration. These vertically aligned morphologies are important for the development of next-generation lithographic techniques and form excellent templates for ultrafiltration membranes with uniform pore sizes. In conclusion, this article demonstrates how IL additives can be used to obtain stable non-equilibrium morphologies in as-cast BCP films and the effect of BCP molecular mass, block volume fractions, and IL content on self-assembly.

59 BASIC BIOLOGICAL SCIENCES↗

PIXE – State of the Art, Systems, Challenges

Particle-induced X-ray emission (PIXE) is an analytical technique for elemental analysis in which a charged-particle beam (most commonly protons, but also alpha particles or heavier ions) ionizes inner-shell electrons in target atoms. When these vacancies are filled by outer-shell electrons, the atom emits characteristic X-rays (e.g., Kα, Kβ, L-series) whose energies are unique to each element. Measuring the X-ray spectrum therefore enables identification of the elements present and, with appropriate calibration and modeling, their concentration. PIXE provides rapid, simultaneous, quantitative multi-element detection with trace-level sensitivity for many mid- to high-Z elements, often with minimal sample preparation. It is widely used across materials science (thin films, alloys, corrosion), geology (mineral chemistry, provenance) and environmental monitoring (aerosols, particulates, soils); semiconductor contamination analysis (wafer surface/trace metals), cultural heritage (pigments, inks, archaeological artifacts) and forensics (gunshot residue, glass/pain), and biological/medical studies (tissue/biomaterial trace-element mapping).

47 OTHER INSTRUMENTATION↗

Analysis of microsize particulates

Unique methods for analyzing individual particles ranging in size from 0.01 to 1000 micrometers have been developed for investigation of nature of cosmic dust. Methods are applicable to particulate aerosols and contaminants characteristically encountered in studies of air pollution and in experiments designed to abate pollution.

Blanchard, M. B.↗

Results of examination of the nasal mucosa

The olfactory epithelium, but not the nasal respiratory epithelium, of the four pocket mice (Perognathus longimembris) that survived their flight on Apollo XVII showed both diffuse alterations and numerous disseminated focal lesions. The olfactory mucosa of the mouse that died during flight was also affected, but to a minor degree insofar as could be determined. All this was in contrast to the normal appearance of the olfactory mucosa of the numerous control animals. A number of possible causes were considered: systemic or regional infection; inhaled particulate material (seed dust); by-products from the KO2 bed in aerosol or particulate form; gas contaminants originating in the flight package; volatile substances from the dead mouse; weightlessness; and cosmic ray particle radiation. Where feasible, studies were conducted in an effort to rule in or rule out some of these potentially causative factors. No definitive conclusions were reached as to the cause of the lesions in the flight mice.

Kraft, L. M.↗

Environmental monitoring for Space Station WP01

External contamination monitoring instrumentation for the Space Station work package one (WP01) elements, were imposed on the contractor as deliverable hardware. The monitoring instrumentation proposed by the WP01 contractor in response to the contract requirement includes both real time measurements and passive samples. Real time measurement instrumentation consists of quartz crystal microbalances for molecular deposition, ion gaseous species identification. Internal environmental contamination monitoring for particulates is included in both Lab and HAB modules. Passive samples consists of four sample mounting plates mounted external to the Space Station modules, two on the U.S. LAB, and two on the HAB module.

Zwiener, J. M.↗

Space Station Environmental Health System water quality monitoring

One of the unique aspects of the Space Station is that it will be a totally encapsulated environment and the air and water supplies will be reclaimed for reuse. The Environmental Health System, a subsystem of CHeCS (Crew Health Care System), must monitor the air and water on board the Space Station Freedom to verify that the quality is adequate for crew safety. Specifically, the Water Quality Subsystem will analyze the potable and hygiene water supplies regularly for organic, inorganic, particulate, and microbial contamination. The equipment selected to perform these analyses will be commercially available instruments which will be converted for use on board the Space Station Freedom. Therefore, the commercial hardware will be analyzed to identify the gravity dependent functions and modified to eliminate them. The selection, analysis, and conversion of the off-the-shelf equipment for monitoring the Space Station reclaimed water creates a challenging project for the Water Quality engineers and scientists.

Vincze, Johanna E.↗