Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials↗

Performance Index Assessment for the PV Fleet Performance Data Initiative

We report on 250 PV systems throughout the United States, comprising 157 MWdc of system capacity and more than 10,000 monthly performance index (PI) values. Loss factors were isolated including first-year start-up issues, snowfall, soiling and inverter downtime. Inverter availability was found to contribute significant system energy loss during the first six months of operation, with an average of 8% loss occurring during this period, and 2.3% on average thereafter. Other start-up issues beyond inverter downtime, such as partial string outage, contributed additional underperformance in the first year of operation across the fleet. Winter performance was also found to be below summer performance on average, likely due to snowfall. A relationship was found between monthly snowfall accumulation in centimeters and monthly under-performance, indicating a 6%-40% loss in months with measured snowfall, depending on climate. After correcting for availability, snow and startup loss, over 90% of systems were performing within 10% of monthly expectation based on satellite resource data and PVWatts production estimates.

loss factors↗

Understanding Solar Photovoltaic System Performance: An Assessment of 75 Federal Photovoltaic Systems

This report presents a performance analysis of 75 photovoltaic systems based on PV system production data collected as part of a FEMP Federal PV Performance Assessment project combined with co-incident insolation, and ambient temperature to analyze how actual performance compares with a performance model. FEMP collaborated with 17 Federal agencies and sub-agencies to collect the information required to analyze the performance of each system. The systems represent a total capacity of 30,714 kW and range in size from 1 kW to 4,043 kW, with an average size of 410 kW, and were installed between 2011 and 2020. The data is analyzed for Key Performance Indicators, Availability, Performance Ratio and Energy Ratio by comparing the measured production data to model production data. The System Advisor Model (SAM) combines a description of the system (such as inverter capacity, de-rating for temperature, balance-of-system efficiency) with environmental parameters (coincident solar and temperature data) to calculate predicted performance. The performance metrics are calculated by lining up the measured production data with the model estimate on an hour-by-hour, day-by-day, or month-by-month basis (depending on the interval resolution of the production data). A report with system description, photo of the system, special assumptions made for the site, graph of measured production and model production, table of key performance indicators, and links to O&M resources that might improve performance was produced and delivered to site and agency staff with a short on-line briefing.

14 SOLAR ENERGY↗

Understanding the Uncertainty in the Technical Performance Level Assessment for Wave Energy

In recent years, the design and development of wave energy converters (WECs) has been explored with intense interest, with highly varying design concepts emerging globally across both research enterprises and industry. The design space for WECs is vast - many concepts ranging in functionality, control systems, power development systems, materials, and scale have been ideated and prototyped, but WEC technology has yet to converge. One critical element of the technology trajectory that governs the speed of adoption is the performance of a WEC concept. In analogous but more-established industries (such as aerospace, and environmentally sustainable electronics design), performance assessment is a quantitative method, based on historical data, that is used as an iterative tool to improve the design of these systems early on in the design process. Though more nascent than these approaches, in wave energy R&D, WEC performance has been assessed using the Technology Performance Level (TPL) assessment, which provides designers with a quantitative score, situating a grid-scale WEC concept on a scale from 1-9 (1 being the lowest performance, and 9 being the highest, trending with the oft-used Technology Readiness Level, or TRL). The TPL assessment is designed to be used during design iteration, when a WEC concept is fully ideated, to enable designers to consider potential means of improving the downstream performance of the concept. One concern that may be slowing the adoption of TPL among WEC developers is the inherent uncertainty in the assessment, and how uncertainty in the individual questions asked as part of the assessment may contribute to perceived inaccuracies in the final score. In this work, we explore the uncertainty present in the assessment and quantify this uncertainty using both traditional mathematical operations and a Monte Carlo simulation. Results imply areas of improvement of the TPL assessment, where reducing uncertainty will be most helpful to end users, enabling both TPL practitioners and users to understand with more accuracy those design elements that can be improved to impact device performance most substantively.

techno-economic analysis↗

Vadose and Saturated Zone Flow and Transport Model Package Report for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

This model package report (MPR) documents the development of the integrated vadose and saturated zone flow and transport model developed for the performance assessment of Trenches 31 and 34 in the low-level burial grounds (LLBGs). This modeling capability is intended for use in addressing the analysis requirements outlined in DOE O 435.1, Chg 1, Radioactive Waste Management1. The overall objective of the modeling effort is to provide a basis for making informed disposal decisions pertinent to Trenches 31 and 34. The purpose of the MPR is to document the development of the three-dimensional numerical vadose zone and saturated flow and transport model test case and evaluate its adequacy to support the LLBG performance assessment. The purpose is not to present results for DOE 435.1 decision making. The use of the model to perform base case and sensitivity analysis for the LLBG performance assessment, including inputs and results, is documented separately in subsequent environmental calculation files. This report discusses the development and translation of the conceptual model for flow and contaminant transport into the LLBG performance assessment three-dimensional numerical flow and transport model evaluated using the Subsurface Transport Over Multiple Phases (STOMP©) simulator. The development of representative geologic framework is described along with the implementation of waste release models used to represent contaminant release from waste disposed in the trenches. The report also provides the technical basis for specific model parameters and boundary conditions, along with description of modeling assumptions. This MPR includes certain calculations that are necessary to demonstrate the soundness of the model. Results provided by the model include vadose zone and saturated zone flow fields, and estimates of the possible future concentration in groundwater of technetium-99 and iodine-129 as example test cases. As an evaluation of the test cases, the model estimates of current vadose conditions are compared to available and analogous field and laboratory data, and compared to the results from the original performance assessment model (WHC-EP-0645, Performance Assessment for the Disposal of Low-Level Waste in the 200 West Area Burial Grounds 2 ). The features, events, and processes applicable to vadose zone and saturated zone flow and transport model are identified, and representative initial estimates for various parameters are documented. Note that the parameter estimates presented in this MPR are for illustration purposes, and may or may not reflect values selected for eventual performance assessment. Several key topical discussions (i.e., basis for recharge estimates, basis for vadose zone modeling, basis for saturated zone model development, and calibration) are included, which serve as the groundwork for confidence building for the groundwater pathway modeling and results. Numerical simulation results based on an example test case are included to illustrate the use of the combined saturated-unsaturated model in performance assessment calculations. Sensitivity and uncertainty results are not included in this MPR. Those results will be included in future environmental calculation files. The inclusion of the trapezoidal trench geometry and construction details in the finite difference grid introduces some gross simplifications regarding the trench and liner systems. The model test case presented in this MPR includes the assumption that the trench liner system does not affect flow through or around the trenches after the liner system is assumed to fail. This MPR also includes results of other test cases that involve alternate assumptions about how to incorporate the hydraulic effects of the trenches into the vadose zone of the model. These alternate cases do not attempt to account for the presence of the liner system after its assumed failure either. None of these cases is considered to be the base case at this time. Analysis and alternate cases that attempt to account for the presence of the liner system in greater detail, and its effect on flow through and around it, are to be documented in subsequent environmental calculation files. Depending on the results of those analyses and alternate cases, the eventual base case may involve more detailed inclusion of the effects of the liner system hydraulics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Rapid Decision Support Tool for Estimating Impacts of a Vadose Zone Volatile Organic Compound Source on Groundwater and Soil Gas

Diminishing rates of subsurface volatile contaminant removal by soil vapor extraction (SVE) oftentimes warrants an in‐depth performance assessment to guide remedy decision‐making processes. Such a performance assessment must include quantitative approaches to better understand the impact of remaining vadose zone contamination on soil gas and groundwater concentrations. The spreadsheet‐based Soil Vapor Extraction Endstate Tool (SVEET) software functionality has recently been expanded to facilitate quantitative performance assessments. The updated version, referred to as SVEET2, includes expansion of the input parameter ranges for describing a site (site geometry, source characteristics, etc.), an expanded list of contaminants, and incorporation of elements of the Vapor Intrusion Estimation Tool for Unsaturated‐zone Sources software to provide soil gas concentration estimates for use in vapor intrusion evaluation. As part of the update, SVEET2 was used to estimate the impact of a tetrachloroethene (PCE) vadose zone source on groundwater concentrations, comparing SVEET2 results to field‐observed values at an undisclosed site where SVE was recently terminated. PCE concentrations from three separate monitoring wells were estimated by SVEET2 to be within the range of 6.0–6.7 μg/L, as compared to actual field concentrations that ranged from 3 to 11 μg/L PCE. These data demonstrate that SVEET2 can rapidly provide representative quantitative estimates of impacts from a vadose zone contaminant source at field sites. Finally, in the context of the SVE performance assessment, such quantitative estimates provide a basis to support remedial and/or regulatory decisions regarding the continued need for vadose zone volatile organic compound remediation or technical justification for SVE termination, which can significantly reduce the cost to complete for a site.

54 ENVIRONMENTAL SCIENCES↗

Critical Evaluation of a Novel Analysis Technique for Assessment of Printed Circuit Heat Exchangers in High-Temperature Nuclear Service

Application of printed circuit heat exchangers (PCHEs) to very high-temperature reactors (VHTRs) requires mechanical performance assessment methodologies. The PCHE morphology consists of thousands of millimeter-scale channels, for enhanced thermal efficiency, enclosed in a meter-scale PCHE core. PCHE geometry under thermomechanical creep-fatigue transients results in multi-axial interactions between its different segments, such as channeled core, walls, and headers. These global-level interactions influence the local channel-level responses. Hence, developing a PCHE performance assessment methodology, following the ASME Code, Section III, Division 5 provisions, is a critical gap to be filled. There is no analysis or design methodology available in ASME Code to assess a PCHE for its global and local level performances under high temperature and pressure loadings. This paper critically evaluates a recently proposed two-step analysis technique to estimate global interactions and local channel-level responses of PCHEs. In this novel analysis technique, the channeled PCHE core is replaced with orthotropic solid blocks of representative stiffness properties for the global thermomechanical analysis. Here, subsequent channel scale submodel analysis with detailed channel geometry, loading, and elastic-perfectly plastic (EPP) material model estimates the local responses for PCHE performance assessment. This paper critically evaluates this novel technique for its effectiveness in PCHE performance assessment. Finite element (FE) models imitating various analysis issues are developed, and FE analysis results are scrutinized. An important outcome of this study is the validation of the novel two-step PCHE analysis technique for application to the performance assessment of PCHEs in VHTRs.

42 ENGINEERING↗

Hazards and Probabilistic Risk Assessments of Advanced Nuclear Reactors Coupled with Industrial Facilities

This report provides a roadmap and tool kit for site specific risk assessments across a broad range of industrial customers co-located with advanced nuclear power plants (ANPP) that are not currently built and operating in the U.S. This report builds upon the body of work sponsored by the Department of Energy (DOE) Integrated Energy Systems Pathway that has produced industrial requirements studies and techno-economic assessments on the topics of feasibility of ANPP supported industrial processes. This report also leverages the DOE Light Water Reactor Sustainability (LWRS) program that has presented hazards assessment and generic probabilistic risk assessments (PRAs) for the addition of a heat extraction system (HES) to light-water reactors (LWRs) co-located with hydrogen production facilities. Many of the hazard assessments and risk assessments performed for the LWRS report are agnostic to whether the nuclear reactor is an ANPP or were adapted to the ANPP focus. The report performs hazards assessments to include industrial facilities: an oil refinery, a methanol plant, a synthetic fuel (synfuel) plant, the production of synthetic gas (syngas) as part of the methanol and synfuel plants, wood pulp and paper mills, and hydrogen production. Hydrogen production facilities are assessed in depth through prior reports in the LWRS program and the results are leveraged in this report. All these facilities are specified through industrial process and requirements research performed by national laboratories, universities, and interaction with industry. Many of the processes used in this report are pre-conceptual designs to use for decarbonization of the current technology facilities. A process of failure modes and effects analysis (what can go wrong) and accidentology (what has historically gone wrong) was used to determine the hazards presented to the nuclear power plant by the addition of the HES and the industrial customer. Chemical properties of feedstocks and products are summarized as part of the hazards assessment. Example analysis procedures are provided for each of the hazard types identified. These deterministic analyses can be used to assess adherence to licensing criteria. They can also be used to meet other safety goals like protection of the public, workers, or industrial facility equipment. A modular high temperature gas-cooled reactor (MHTGR) PRA only existing on paper was modeled and verified in modern PRA software. This will provide a tool for representative ANPP probabilistic analyses for future research.

10 SYNTHETIC FUELS↗

Simplified Approach for Scoping Assessment of Non-LWR Source Terms

This report describes a structure to aid in evaluation of release mitigation strategies across a range of reactor technologies. The assessment performed for example reactor concepts utilizes previous studies of postulated accident sequences for each reactor concept. This simplified approach classifies release mitigation strategies based on a range of barriers, physical attenuation processes, and system performance. It is not, however, intended to develop quantitative estimates of radiological release magnitudes and compositions to the environment. Rather, this approach is intended to identify the characteristics of a reactor design concepts release mitigation strategies that are most important to different classes of accident scenarios. It uses a scoping methodology to provide an approximate, order-of-magnitude, estimate of the radiological release to the environment and associated off-site consequences. This scoping method is applied to different reactor concepts, considering the performance of barriers to fission product release for these concepts under sample accident scenarios. The accident scenarios and sensitivity evaluations are selected in this report to evaluate the role of different fission product barriers in ameliorating the source term to the environment and associated off-site consequences. This report applies this structure to characterize how release mitigation measures are integrated to define overall release mitigation strategies for High Temperature Gas Reactors (HTGRs), Sodium Fast Reactors (SFRs), and liquid fueled Molten Salt Reactors (MSRs). To support this evaluation framework, factors defining a chain of release attenuation stages, and thus an overall mitigation strategy, must be established through mechanistic source term calculations. This has typically required the application of an integral plant analysis code such as MELCOR. At present, there is insufficient evidence to support a priori evaluation of the effectiveness of a release mitigation strategy for advanced reactor concepts across the spectrum of events that could challenge the radiological containment function. While it is clear that these designs have significant margin to radiological release to the environment for the scenarios comprising the design basis, detailed studies have not yet been performed to assess the risk profile for these plants. Such studies would require extensive evaluation across a reasonably complete spectrum of accident scenarios that could lead to radiological release to the environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Past Approaches for Spent Nuclear Fuel, High-Level, and Transuranic Waste Disposal in the United States—Part 1: Safety Criteria and Treatment of Uncertainty

The United States (US), with its 50-year experience in developing deep geologic disposal for transuranic waste, spent nuclear fuel (SNF), and high-level radioactive waste (HLW), has much to share with other countries. Yet, other countries are better able to translate the US experience and corresponding policy decisions into solutions sensible for their country when they understand the compliance requirements in US laws and regulations. This paper presents past approaches in the generic and site-specific standards of the US Environmental Protection Agency (EPA) and implementing regulations of the US Nuclear Regulatory Commission (NRC) using the framework provided by (1) key questions of the Blue Ribbon Commission on America’s Nuclear Future, and (2) international consensus standards. Both the 1985 EPA generic standards, as updated in 1993 and applied at the operating Waste Isolation Pilot Plant in southern New Mexico for transuranic waste from atomic energy defense activities, and the EPA 2008 site-specific standards and implementing regulations, as applied at the proposed Yucca Mountain repository in southern Nevada for SNF and HLW, adopt the strategy of using quantitative, probabilistic analysis to assess performance and compliance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A harmonized protocol to assess the single-cell performance of proton exchange membrane water electrolyzers

The harmonization of testing protocols for proton exchange membrane (PEM) electrolyzers is essential for ensuring accurate and reliable performance assessments and accelerating the development of hydrogen production technologies. This protocol provides a structured approach to PEM electrolyzer setup and testing, incorporating key considerations for test station design and single-cell characterization techniques. Polarization curves and electrochemical impedance spectroscopy (EIS) are detailed, along with best practices from academic and industry research groups to enhance data accuracy and comparability. By addressing material variability and harmonizing testing methodologies, this framework enables more precise evaluations of membrane electrode assemblies and electrolyzer components. Harmonized protocols not only streamline development efforts but also foster collaboration across institutions, ultimately supporting the commercialization of hydrogen solutions through improved stack efficiency and durability.

08 HYDROGEN↗