Permeability of membranes to amino acids and modified amino acids: mechanisms involved in translocation

The amino acid permeability of membranes is of interest because they are one of the key solutes involved in cell function. Membrane permeability coefficients (P) for amino acid classes, including neutral, polar, hydrophobic, and charged species, have been measured and compared using a variety of techniques. Decreasing lipid chain length increased permeability slightly (5-fold), while variations in pH had only minor effects on the permeability coefficients of the amino acids tested in liposomes. Increasing the membrane surface charge increased the permeability of amino acids of the opposite charge, while increasing the cholesterol content decreased membrane permeability. The permeability coefficients for most amino acids tested were surprisingly similar to those previously measured for monovalent cations such as sodium and potassium (approximately 10(-12)-10(-13) cm s-1). This observation suggests that the permeation rates for the neutral, polar and charged amino acids are controlled by bilayer fluctuations and transient defects, rather than partition coefficients and Born energy barriers. Hydrophobic amino acids were 10(2) more permeable than the hydrophilic forms, reflecting their increased partition coefficient values. External pH had dramatic effects on the permeation rates for the modified amino acid lysine methyl ester in response to transmembrane pH gradients. It was established that lysine methyl ester and other modified short peptides permeate rapidly (P = 10(-2) cm s-1) as neutral (deprotonated) molecules. It was also shown that charge distributions dramatically alter permeation rates for modified di-peptides. These results may relate to the movement of peptides through membranes during protein translocation and to the origin of cellular membrane transport on the early Earth.

Review↗

Effects of Porous Gap Fillers on 30P30N Leading-Edge SlatNoise. Part I: Surface Pressure and Acoustics

The leading edge slat of a high-lift system is one of the main contributors to airframe noise during approach. In a previous experimental study, we assessed the performance of an impermeable slat gap filler as a passive flow control device to reduce the slat noise associated with a two-dimensional, three-element high-lift airfoil. The present paper, the first of two parts,represents a follow-on investigation to assess the relative efficacy of permeable gap fillers thatallow successively higher amounts of flow to pass through the gap. To evaluate the influence of this passive flow control device on the acoustics generated by the unsteady flow near the slat, experiments are conducted in an anechoic wind tunnel by mounting a gap filler to the slat element of the two-dimensional 30P30N high-lift configuration. Measurements are performed at a single geometric angle of attack (𝛼𝑘=8◦) and three different flow speeds that correspond to Reynolds numbers of𝑅𝑒𝑐=1.2𝑒6,1.5𝑒6, and1.71𝑒6, respectively. Steady surface pressure measurements are used to gauge the influence of the permeable gap filler treatments on the overall lift. The effect of each treatment on the radiated noise is analyzed via acoustic array measurements, followed by delay-and-sum beamforming to locate the slat noise sources and to provide the integrated acoustic spectra. The porous gap fillers are found to eliminate the narrowband peaks in the acoustic spectra and, also, to yield a 10 dB reduction in the broadband noise in comparison with the baseline case with no gap filler. The porous gap filler with thelowest permeability acts similar to the impermeable gap filler examined previously. However, the aerodynamics and noise reduction both degrade with increasing permeability. An accompanying abstract describes the particle image velocimetry measurements of the flowfield within the slat cove and on either side of the permeable gap f

slat noise↗

Controlled phosphate doping into nanoscopic SiO 2 proton conducting membranes

This article describes a method to introduce phosphate (PO 4 ) into SiO 2 atomic layer deposition (ALD) films in a self-limiting fashion. The method involves the use of a less common phosphate precursor, trimethyl phosphite [P(OMe) 3 ], to introduce PO 4 as a low-level dopant, <1 at. %, into a SiO 2 ALD process using bis(ethylmethylamino)silane and a modified O 3 conversion. P(OMe) 3 does not deposit a film with typical oxygen sources but incorporates as PO 4 in an ABC-type ALD scheme at deposition temperatures ranging from 100 to 300 °C. Addition of up to ∼1 at. % of PO 4 does not significantly impact the film density or concentrations of carbon and nitrogen impurities, which are both <0.4 at. %. Despite the relatively low dopant concentrations, PO 4 incorporation is shown to have a large impact on transport properties of the film. When explored as proton (H + )-conducting membranes, undoped SiO 2 ALD films showed H + conductivities (3 × 10 −6 –8 × 10 −5 S cm −1 ) and low H 2 permeabilities (<10 −9 cm 2 s −1 ) when measured at room temperature. The addition of PO 4 is shown to increase H + conductivity to 2 × 10 −4 S cm −1 , while maintaining low H 2 permeability of <10 −9 cm 2 s −1 . The ratio of H + conductivity to H 2 permeability, a key performance metric for H + -conducting membranes used in water electrolyzers, exceeds that of commercial Nafion-117 membranes. Here, the moderate H + conductivity and very low H 2 permeability of PO 4 -doped SiO 2 films make them promising candidates as fluorine-free replacements for Nafion in applications such as water electrolysis, hydrogen fuel cells, and redox flow batteries.

Atomic layer deposition↗

An experimental system and procedure of unsteady-state relative permeability test for gas hydrate-bearing sediments

Reliable estimations of the relative permeability of gas and water in hydrate-bearing sediments (HBS) and the dependency of the relative permeability on hydrate saturation are critical to predict the productivity of a hydrate reservoir. Yet, this remains poorly estimated owing to lack of experimental data associated with difficulties in conducting multiphase flow experiments in HBS. Recognizing the experimental challenges, this study intends to develop and validate a new experimental system and procedure of unsteady-state relative permeability test that can generate reliable and reproducible flow measurements in HBS. Furthermore, gas hydrate is considered as a part of solid matrix in the sediment, so one of the challenges is to maintain a constant hydrate saturation, which is achieved in this experimental study using tight pressure-temperature (P-T) control near the hydrate stability boundary. The measured differential pressure across the specimen, methane injection flow rate, and volume of displaced brine are used to calculate the relative permeability by adopting a conventional Buckley-Leverett theory-based interpretation method. Residual brine saturation calculated for the hydrate-bearing specimen is higher than that of hydrate-free specimen, presumably due to decrease in pore size, increase in heterogeneity of solid matrix, and increase in size distribution of solid matrix and pore in the presence of hydrates. Further studies are necessary to represent the results of the unsteady-state flow experiment in HBS with a gas hydrate-dependent relative permeability model.

03 NATURAL GAS↗

The permanent and induced magnetic dipole moment of the moon

Magnetic field observations with the Apollo 15 subsatellite have been used to deduce the components of both the permanent and induced lunar dipole moments in the orbital plane. The present permanent lunar magnetic dipole moment in the orbital plane is less than 1.3 times ten to the eighteenth power gauss-cu cm. Any uniformly magnetized near surface layer is therefore constrained to have a thickness-magnetization product less than 2.5 emu-cm per g. The induced moment opposes the external field, implying the existence of a substantial lunar ionosphere with a permeability between 0.63 and 0.85. Combining this with recent measures of the ratio of the relative field strength at the ALSEP and Explorer 35 magnetometers indicates that the global lunar permeability relative to the plasma in the geomagnetic tail lobes is between 1.008 and 1.03.

Russell, C. T.↗

Static structural tests of a 1.5-meter diameter fabric attached inflatable decelerator

Meridional tape forces, permeability, and change in model contours were measured on the aft half of a 1.5-m-diameter attached inflatable decelerator (AID). Inflation pressures up to 103 kN per square meter and external pressures of 0.14 to 102 kN per square meter were used. The results indicated that the model stresses were near the desired isotensoid condition. Future AID designs should consider both stiffness and strength of the meridional tapes to obtain the optimum division of load between tapes and fabric. Permeability of pressurized fabric structures is a few orders of magnitude higher than that obtained in the standard low-pressure test on material specimens.

Willis, C. M.↗

Self‐gated, dynamic contrast‐enhanced magnetic resonance imaging with compressed‐sensing reconstruction for evaluating endothelial permeability in the aortic root of atherosclerotic mice

High‐risk atherosclerotic plaques are characterized by active inflammation and abundant leaky microvessels. We present a self‐gated, dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) acquisition with compressed sensing reconstruction and apply it to assess longitudinal changes in endothelial permeability in the aortic root of Apoe −/− atherosclerotic mice during natural disease progression. Twenty‐four, 8‐week‐old, female Apoe −/− mice were divided into four groups (n = 6 each) and imaged with self‐gated DCE‐MRI at 4, 8, 12, and 16 weeks after high‐fat diet initiation, and then euthanized for CD68 immunohistochemistry for macrophages. Eight additional mice were kept on a high‐fat diet and imaged longitudinally at the same time points. Aortic‐root pseudo‐concentration curves were analyzed using a validated piecewise linear model. Contrast agent wash‐in and washout slopes ( b 1 and b 2 ) were measured as surrogates of aortic root endothelial permeability and compared with macrophage density by immunohistochemistry. b 2 , indicating contrast agent washout, was significantly higher in mice kept on an high‐fat diet for longer periods of time ( p = 0.03). Group comparison revealed significant differences between mice on a high‐fat diet for 4 versus 16 weeks ( p = 0.03). Macrophage density also significantly increased with diet duration ( p = 0.009). Spearman correlation between b 2 from DCE‐MRI and macrophage density indicated a weak relationship between the two parameters (r = 0.28, p = 0.20). Validated piecewise linear modeling of the DCE‐MRI data showed that the aortic root contrast agent washout rate is significantly different during disease progression. Further development of this technique from a single‐slice to a 3D acquisition may enable better investigation of the relationship between in vivo imaging of endothelial permeability and atherosclerotic plaques' genetic, molecular, and cellular makeup in this important model of disease.

Calcagno, Claudia↗

Optimization of flow in additively manufactured porous columns with graded permeability

Chemical engineering systems often involve a functional porous medium, such as in catalyzed reactive flows, fluid purifiers, and chromatographic separations. Ideally, the flow rates throughout the porous medium are uniform, and all portions of the medium contribute efficiently to its function. The permeability is a property of a porous medium that depends on pore geometry and relates flow rate to pressure drop. Additive manufacturing techniques raise the possibilities that permeability can be arbitrarily specified in three dimensions, and that a broader range of permeabilities can be achieved than by traditional manufacturing methods. Using numerical optimization methods, we show that designs with spatially varying permeability can achieve greater flow uniformity than designs with uniform permeability. We consider geometries involving hemispherical regions that distribute flow, as in many glass chromatography columns. By several measures, significant improvements in flow uniformity can be obtained by modifying permeability only near the inlet and outlet.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding Fracture Aperture and Permeability Evolution due to Carbonate Mineralization Utilizing 3D Printing

Caprock formations are a crucial part of subsurface-engineered systems. Composed largely of shale, caprocks act as natural barriers that prevent the upward migration of fluids, thereby ensuring the containment of stored substances in subsurface formations. Fractures in these formations are potential leakage pathways for stored fluids. Mineral precipitation reactions in these fractures, particularly calcite, can significantly restrict the fluid permeability, reducing leakage potential. However, predictive capabilities of mineral precipitation in fractures and associated permeability evolution are limited due to a lack of fundamental understanding of such reactions in natural samples, complicated by mineral heterogeneity and the complexity of the fracture structure. In this study, 3D-printed fracture samples are used to understand the impact of carbonate mineralization on fracture aperture and permeability evolution. Samples were printed using a digital light processing (DLP) 3D printer and commercial liquid resin. Calcite precipitation was first tested on printed 2D films before conducting plug flow column experiments aimed to understand fracture permeability changes due to mineral precipitation. Contact angle measurement and Fourier transform infrared (FTIR) spectroscopy on printed 2D films show evidence of a substantial amount of surface energy for calcite nucleation and precipitation. Surface topography analysis of printed fractured surfaces reveals comparable values, highlighting the high replicability of the printed samples. During the column experiments, the permeability reduces exponentially due to a decrease in fracture aperture. Reductions in fracture aperture estimated from effluent concentration and 3D X-ray computed tomography (CT) show comparable results. Moreover, 3D X-ray CT images suggest the impact of local flow velocities on precipitation. The insights gained from this research contribute to a deeper understanding of the permeability evolution due to carbonate mineralization in caprock formations.

3D printing↗

Biomechanics of the Optic Nerve Sheath in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

fluid shifts↗

Effects of Porous Gap Fillers on Leading-Edge Slat Noise of 30P30N. Part II: PIV Measurements

The leading edge slat of a high-lift system is one of the main contributors to the airframe noise during approach conditions. This paper, the second of two parts, continues our previous studies on the slat gap filler as a passive noise control device on the two-dimensional, 30P30N multielement airfoil. Whereas the earlier study was focused on the effects of an impermeable gap filler that completely blocks the flow through the gap, this follow-on assessment is devoted to permeable slat gap fillers that allow limited amounts of flow to pass through the gap. Part I of this two-part abstract described the aerodynamic and acoustic effects of the permeable gap fillers, as inferred from both the measurements of static and unsteady surface pressures and the microphone array data for the radiated noise. To understand the physical mechanism responsible for the noise reduction documented in Part I, as well as for the accompanying aerodynamic penalty due to the porous gap fillers, Particle Image Velocimetry (PIV) is used in this paper to measure the flow details in the slat-cove region of the 30P30N model. A single angle of attack (𝛼 = 5.5◦) and a chord based Reynolds number of 1.71𝑒6 are selected as the test conditions. The PIV results show that the slat flow features are significantly altered with the presence of the porous gap filler, resulting in a more stable slat-cove shear layer and, thus, reduced velocity fluctuations with a successive decrease in the permeability. The porous gap filler with the lowest permeability acts similar to the solid gap filler. However, flow separation is observed on the upper side of the porous interface, which leads to an aerodynamic performance penalty via a reduction in lift on the main wing.

slat noise↗

Determination of permeability for hydrocarbon release due to excavation-induced stress redistribution in rock salt

Due to a stress redistribution after the excavation of an underground tunnel for radioactive waste disposal, an Ed/DZ (excavation disturbed/damaged zone) will be generated in the near field of the opening, resulting in significant changes in the hydraulic and mechanical properties of the rock mass in the zone. Initially more or less randomly distributed hydrocarbons at grain boundaries in rock salt, which sometimes can only be observed with ultraviolet light, can then be mobilised and migrate at a potentially significant rate towards the excavation. Within the international cooperative project DECOVALEX 2019, the migration mechanism of such fluid inclusions in rock salt is being studied intensively. Specifically, a multi-scale modelling strategy has been developed. A macroscale coupled hydro-mechanical modelling of an underground excavation was performed to determine hydraulic and time-dependent deviatoric stress conditions, by taking into account the rock salt creep behaviour. Under the obtained macro-scale constraints, micro-scale modelling of a pathway dilation along halite grain boundaries was performed using different model strategies: a) coupled hydromechanical modelling with a consideration of hydraulic pressure-induced dilatant deformation, b) nonlinear dynamic model taking account of fluid migration, stress-dependent grain boundary wetting and shear-induced dilatancy of salt, and c) phase-field modelling of flow pathway propagation. The permeability increase resulting from the pathway dilation is estimated to be as high as two orders of magnitude. Based on the permeability determined, a series of pressure buildups measured from a borehole with a high hydrocarbon release rate, a total of 430 build-ups within a monitoring time of 938 days, can be simulated with a macro-scale compressible flow model accounting for different zones around the opening.

58 GEOSCIENCES↗

Nanostructure refinement and phase formation of flash annealed FeNi-based soft magnetic alloys

In this work, the resulting nanocomposite microstructures of FeNi nanocrystallites under different heating and cooling rates (5 °C/min vs 400-500 °C/s) is investigated. Conventional furnace annealing under low heating rates and slow cooling resulted in both BCC α-FeNi and FCC γ-FeNi nanocrystallites with an average grain size on the order of 25-27 nm whereas high heating rates achieved via flash annealing techniques have enabled a dramatically refined microstructure consisting of 5-7 nm grains with FCC γ-FeNi phase and found to be the dominant phase following primary crystallization. Grain size refinement and phase identity optimization yielded low values of coercivities-17 A/m and high permeability similar to 11 x 10 3 measured at 400 Hz/1 kA/m in flash annealed samples at 450 °C for 5 s. The magnetic behavior and the underlying mechanism of optimal soft magnetic properties are discussed in terms of the critical role of the grain size in domain wall pinning and coercivity.

36 MATERIALS SCIENCE↗

Unsteady- and Steady-State Relative Permeability Study with X-ray and Acoustic Monitoring for CO 2 Storage in Deep Saline Aquifers

In this study, we link the multiphase flow measurements with controls of sedimentary structures (e.g., heterogeneity and anisotropy) on relative permeability to variations in ultrasonic velocities for two deep saline aquifer formations (Entrada and Bluff Sandstones) in the San Juan Basin of the Southwestern USA. The rock specimens were extracted from outcrop sites near Durango, CO, USA. They have distinct differences in grain size, cementation composition, and individual chemical amounts, despite both formations being eolian sandstones. We performed a series of unsteady- and steady-state CO 2 -brine relative permeability experiments under capillary-controlled displacement rates. Unsteady-state experiments were conducted at 71 °C and 9.65 MPa; steady-state experiments were conducted at 85 °C and 22.8 MPa and 89 °C and 24.1 MPa for the Bluff and Entrada Sandstones, respectively. During the unsteady experiments, X-ray computed tomography was used to visualize multiphase flow in porous media and quantify saturations during brine drainage under various flow rates. Scan images and saturation profiles indicate that the CO 2 distribution in the pore volume was strongly impacted by the presence of high-angle cross-laminations, heterogeneous rock structure, and direction of bedding orientation. Those factors contribute to dramatic and quick initial breakthroughs and affect the overall saturation dynamics. Steady-state relative permeability tests were conducted at net flow rates of 1 mL/min for both brine drainage and imbibition. During the experimental steps, the CO 2 fractional flow was increased and decreased for both drainage and imbibition scenarios to mimic the front when CO 2 contacts brine and behind the front when brine enters space previously occupied by CO 2 . It was found that compressional velocity decreased, while shear waves slightly increased as brine saturation decreased. The hysteresis effects for the relative permeability and acoustic velocities were distinct. Furthermore, the CO 2 /brine front stability is quantified by applying a mobility ratio approach to spot saturations at which the boundary line between fluids becomes uneven. The results presented in this work can potentially boost the quality and precision of forecasts for the CO 2 storage projects in which the vertical and horizontal core-scale heterogeneity and anisotropy impact the plume migration within host reservoirs.

carbon dioxide (CO2)↗

Lunar magnetic permeability studies and magnetometer sensitivity

A regression of quiet magnetic field components simultaneously measured by the two Explorer 35 magnetometers reveals uncertainties in effective sensitivity factors of up to a few percent in one or both of these instruments. Given this, the validity of previous lunar permeability studies based on Explorer 35/ALSEP regressions, wherein inferences are drawn from regression line slopes differing from unity by the order of one percent, is called into question. We emphasize the need to critically address the question of small deviations in magnetometer sensitivity factors from nominal values as a part of any two-magnetometer lunar permeability study.

King, J. H.↗

Optic Nerve Sheath Mechanics and Permeability in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

biomechanics↗

Metal Standards for Waveguide Characterization of Materials

Rectangular-waveguide inserts that are made of non-ferromagnetic metals and are sized and shaped to function as notch filters have been conceived as reference standards for use in the rectangular- waveguide method of characterizing materials with respect to such constitutive electromagnetic properties as permittivity and permeability. Such standards are needed for determining the accuracy of measurements used in the method, as described below. In this method, a specimen of a material to be characterized is cut to a prescribed size and shape and inserted in a rectangular- waveguide test fixture, wherein the specimen is irradiated with a known source signal and detectors are used to measure the signals reflected by, and transmitted through, the specimen. Scattering parameters [also known as "S" parameters (S11, S12, S21, and S22)] are computed from ratios between the transmitted and reflected signals and the source signal. Then the permeability and permittivity of the specimen material are derived from the scattering parameters. Theoretically, the technique for calculating the permeability and permittivity from the scattering parameters is exact, but the accuracy of the results depends on the accuracy of the measurements from which the scattering parameters are obtained. To determine whether the measurements are accurate, it is necessary to perform comparable measurements on reference standards, which are essentially specimens that have known scattering parameters. To be most useful, reference standards should provide the full range of scattering-parameter values that can be obtained from material specimens. Specifically, measurements of the backscattering parameter (S11) from no reflection to total reflection and of the forward-transmission parameter (S21) from no transmission to total transmission are needed. A reference standard that functions as a notch (band-stop) filter can satisfy this need because as the signal frequency is varied across the frequency range for which the filter is designed, the scattering parameters vary over the ranges of values between the extremes of total reflection and total transmission. A notch-filter reference standard in the form of a rectangular-waveguide insert that has a size and shape similar to that of a material specimen is advantageous because the measurement configuration used for the reference standard can be the same as that for a material specimen. Typically a specimen is a block of material that fills a waveguide cross-section but occupies only a small fraction of the length of the waveguide. A reference standard of the present type (see figure) is a metal block that fills part of a waveguide cross section and contains a slot, the long dimension of which can be chosen to tailor the notch frequency to a desired value. The scattering parameters and notch frequency can be estimated with high accuracy by use of commercially available electromagnetic-field-simulating software. The block can be fabricated to the requisite precision by wire electrical-discharge machining. In use, the accuracy of measurements is determined by comparison of (1) the scattering parameters calculated from the measurements with (2) the scattering parameters calculated by the aforementioned software.

Lambert, Kevin M.↗