Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photovoltaic array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Floating solar panels on reservoirs impact phytoplankton populations: A modelling experiment

Floating solar photovoltaic (FPV) deployments are increasing globally as the switch to renewable energy intensifies, representing a considerable water surface transformation. FPV installations can potentially impact aquatic ecosystem function, either positively or negatively. However, these impacts are poorly resolved given the challenges of collecting empirical data for field or modelling experiments. In particular, there is limited evidence on the response of phytoplankton to changes in water body thermal dynamics and light climate with FPV. Given the importance of understanding phytoplankton biomass and species composition for managing ecosystem services, we use an uncertainty estimation approach to simulate the effect of FPV coverage and array siting location on a UK reservoir. FPV coverage was modified in 10% increments from a baseline with 0% coverage to 100% coverage for three different FPV array siting locations based on reservoir circulation patterns. Results showed that FPV coverage significantly impacted thermal properties, resulting in highly variable impacts on phytoplankton biomass and species composition. The impacts on phytoplankton were often dependent on array siting location as well as surface coverage. Changes to phytoplankton species composition were offset by the decrease in phytoplankton biomass associated with increasing FPV coverage. We identified that similar phytoplankton biomass reductions could be achieved with less FPV coverage by deploying the FPV array on the water body's faster-flowing area than the central or slower flowing areas. The difference in response dependent on siting location could be used to tailor phytoplankton management in water bodies. Simulation of water body-FPV interactions efficiently using an uncertainty approach is an essential tool to rapidly develop understanding and ultimately inform FPV developers and water body managers looking to minimise negative impacts and maximise co-benefits.

14 SOLAR ENERGY↗

Utility-Scale Solar, 2021 Edition

Berkeley Labs "Utility-Scale Solar", 2021 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2020, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, and interconnection queue data.

2021↗

Updated sustainability status of cadmium telluride thin‐film photovoltaic systems and projections

This paper provides a comprehensive assessment of the up-to-date life-cycle sustainability status of cadmium-telluride based photovoltaic (PV) systems. Current production modules (Series 6 and Series 7) are analyzed in terms of their energy performance and environmental footprint and compared with the older series 4 module production and current single-crystalline Silicon (sc-Si) module production. For fixed-tilt systems with Series 6 modules operating under average US irradiation of 1800 kWh/m 2 /year, the global warming potential (GWP) is reduced from 16 g CO 2eq /kWh in Series 4 systems to 10 CO 2 eq /kWh in Series 6 systems. For operation in US-SW irradiation of 2300 kWh/m 2 /year, the GWP is reduced from 11 to 8 CO 2eq /kWh and for 1-axis tracking systems operating in Phoenix, Arizona, with point-of array irradiation of 3051 kWh/m 2 /year the GWP is reduced to 6.5 CO 2eq /kWh. Similar reductions have happened in all environmental indicators. Energy payback times (EPBT) of currently installed systems range from 0.6 years for fixed–tilt ground–mounted installations at average US irradiation at latitude tilt installations to 0.3 years for one-axis trackers at high US-SW irradiation, considering average fossil-fuel dominated electricity grids with fuel to electricity conversion efficiency of 0.3. The resulting energy return on energy investment (EROI) also depends on the conversion efficiency of the electricity grid and on the operation life expectance. For a 30-year operational life and grid conversion efficiency of 0.3, EROI ranges from 50 (at US average irradiation) to 70 for US-SW irradiation. The EROI declines with increased grid conversion efficiency; for CdTe PV operating in south California with grid conversion efficiency of 49%, the EROI is about 50 and is projected to fall to 30 when the state's 2030 target of 80% renewable energy penetration materializes. Material alternatives that show a potential of further reductions in degradation rates and materials for enhanced encapsulation that would enable longer operation lives have also been investigated. A degradation rate of 0.3%/year, which has been verified by accelerated testing, is assumed in 30-year scenarios; this is projected to be reduced to 0.2%/year in the near-term and potentially to 0.1%/year in the longer term. With such low degradation rates and enhanced edge-sealing, modules can last 40- to 50-years. Consequently, all impact indicators will be proportionally reduced while EROI will increase. This detailed LCA was conducted according to ISO standards and IEA PVPS Task 12 guidelines. Furthermore, the study revealed that the choices of system models, methods and temporal system boundaries can significantly impact the results and points out to the need to include assumptions regarding these choices in the “transparency in reporting” requirements listed in the IEA PVPS Task 12 Guidelines.

14 SOLAR ENERGY↗

Rear-Side Irradiance Simulation of Field PV Modules: Preprint

Assessing the durability of photovoltaic (PV) module backsheet is critical to increasing module lifetime. Historically, laboratory-based accelerated testing has insufficient in predicting large-scale failures of commercial polymeric materials. Additionally, there is growing concern that standard condition tests do not reflect non-uniformities in field exposure, and that certain modules experience more severe degradation due to their location. Anisotropy in field exposures is installation dependent and reflects different levels of exposure to irradiance due to mounting geometry, ground surface albedo, and climatic zone. "Bificial Radiance" [1], simulates the amount of reflected irradiance on the Polyethylene Naphthalate (PEN) backsheet of a PV array located in Maryland. In our work, site specific weather data are gathered for the entire length of exposure for the modules. The total full-spectrum dose for the incident irradiance on the backsheet was then determined. The simulation results are integrated with historical field survey data to better understand realworld outdoor degradation.

backsheet↗

Rear-Side Irradiance Simulation of Field PV Modules

Assessing the durability of photovoltaic (PV) module backsheet is critical to increasing module lifetime. Historically, laboratory-based accelerated testing has insufficient in predicting large-scale failures of commercial polymeric materials. Additionally, there is growing concern that standard condition tests do not reflect non-uniformities in field exposure, and that certain modules experience more severe degradation due to their location. Anisotropy in field exposures is installation-dependent and reflects different levels of exposure to irradiance due to mounting geometry, ground surface albedo, and climatic zone. "Bificial_Radiance" [1], simulates the amount of reflected irradiance on the Polyethylene Naphthalate (PEN) backsheet of a PV array located in Maryland. In our work, site specific weather data are gathered for the entire length of exposure for the modules. The total full-spectrum dose for the incident irradiance on the backsheet was then determined. The simulation results are integrated with historical field survey data to better understand real orld outdoor degradation.

backsheet↗

Feature review of photovoltaic modeling software utilizing blind performance assessment

While confidence in photovoltaic (PV) modeling software has always been essential, the rapid pace of new PV plant developments makes accuracy and credibility more critical than ever. Independent assessments, particularly through blind modeling comparisons, are therefore necessary to ensure unbiased benchmarking across PV modeling software. Previous studies have been limited by a narrow range of models compared, anonymized results, or system size. This study presents results from the first-ever onymous blind modeling comparison, evaluated using both lab- and utility-scale fixed-tilt, monofacial, south-facing systems at sub-hourly time intervals. Seven commercially used PV software tools were compared: 3E SynaptiQ, PlantPredict, PVsyst, RatedPower, SAM, SolarFarmer, and Solargis Evaluate. Predictions were submitted directly by software representatives, providing unique insights into each software’s implementation and resulting prediction behavior. Notable features, including plane-of-array (POA) transposition model, module temperature model, shading model, and performance model were analyzed and compared. Four summary tables compile these features of the software, serving as a resource to help users understand the methodological differences and select the most suitable software for their applications. The software tools show deviations from mean error in annual yield up to 2.5 % in the lab-scale system, increasing to 6.0 % for the utility-scale system. These differences arise from a combination of user decisions and the inherent behavior of the software, indicating the need for continuous and rigorous validation of modeling methods using these software tools against complex, real-world systems.

14 SOLAR ENERGY↗

Single-Axis Tracker Control Optimization Potential for the Contiguous United States

Conventional tracker control algorithms maximize collection of direct irradiance with no regard for collection of diffuse irradiance. Therefore, a tracker control algorithm that optimizes for maximal total irradiance, not just direct, might realize improved insolation collection. Using weather data gridded at 0.25° by 0.25° latitude/longitude spacing covering the contiguous United States, we evaluate the insolation gain of two alternative control algorithms optimized for improved total irradiance collection in monofacial arrays and present annual and monthly geographic heatmaps showing the gains across the contiguous United States. Certain locations show potential annual insolation gains approaching 1.0%, but most locations with recently-built tracker systems show annual gains between 0.1% and 0.4%. We also demonstrate a relationship between a climate's annualized diffuse insolation fraction and its potential tracker optimization insolation gain.

diffuse↗

Defect Quantification in Metal Halide Perovskites Anticipates Photoluminescence and Photovoltaic Performance

Semiconductor material optimization requires quantification of performance and stability-dependent near-valence maximum and near-conduction minimum defects with sufficient energy resolution and sensitivity. In this work, we utilize a spectroscopy-electrochemistry approach to resolve the energy-distinct donor and acceptor defect concentrations in wide-gap (Cs .05 FA .79 MA .16 )Pb(I .87 Br .13 ) 3 perovskites, benchmarked against photoluminescence and photovoltaic device performance. Monitoring charge transfer events to electron acceptor and donor molecules within solid electrolyte top contacts enables defect quantification below 10 15 cm –3 at an energy resolution of 10 meV under device-relevant bias, well below levels reported by other methods. Further method sensitivity is demonstrated for defects arising from <2% formamidinium concentration modifications, mimicking compositional imperfections resulting from nonoptimized processing. This method provides the first complete perovskite energetic diagrams with small changes in composition, is nondestructive, compatible with in-line processing characterization, and will enable the semiconductor community to link molecular origins of defects with limitations in device performance across a wide array of optoelectronic platforms.

14 SOLAR ENERGY↗

Single-Axis Tracker Control Optimization Potential for the Contiguous United States: Preprint

Conventional tracker control algorithms maximize collection of direct irradiance with no regard for collection of diffuse irradiance. Therefore, a tracker control algorithm that optimizes for maximal total irradiance, not just direct, might realize improved insolation collection. Using weather data gridded at 0.25° by 0.25° latitude/longitude spacing covering the contiguous United States, we evaluate the insolation gain of two alternative control algorithms optimized for improved total irradiance collection in monofacial arrays and present annual and monthly geographic heatmaps showing the gains across the contiguous United States. Certain locations show potential annual insolation gains approaching 1.0%, but most locations with recently-built tracker systems show annual gains between 0.1% and 0.4%. We also demonstrate a relationship between a climate's annualized diffuse insolation fraction and its potential tracker optimization insolation gain.

diffuse↗

A Real-Time ANPC Inverter Digital Twin with Integrated Design-For-Trust

The demand for renewable energy has increased over the last few years, and so has the demand for greater expectations within the energy market. This increasing trend has been accompanied by more significant usage of internet-connected devices (IoT), leading to critical electrical infrastructure being connected to the internet. Implementing internet connectivity with such devices and systems provides benefits such as improving the system's performance, facilitating irregularity and anomaly mitigation, and providing additional situational awareness for enhanced decision-making. However, enhancing the connected system with IoT introduces a drawback – a greater vulnerability to cyber-attacks. Cyber-attacks targeting critical infrastructure in the electrical sector have occurred in the United States and Ukraine. These cyber-attacks highlight and expose vulnerabilities that a system inherits when connecting to the internet. These attacks left thousands of customers without electricity for hours until operators could regain control of the electric utility grid. Therefore, to address the vulnerabilities of an internet-connected power electronic device, this work focused on the hardware layer of the system. Implementing a cyber-control system inside the hardware layer can significantly reduce the possibility of an attacker patching malicious controller firmware into a photovoltaic grid-connected inverter, thus mitigating the likelihood that the inverter becomes inactive a cyber-attack scenario. With this mitigation technique, if a cyberattack is successful and an attacker gains control of the network, a cyber-defense technique is in place to mitigate the impact of the cyber-attack. This additional protection layer was developed based on an innovative concept known as Digital Twin (DT). A DT, in this case, replicates an Active-Neutral Point Clamped (ANPC) inverter and was designed using a hardware language known as VHDL (Very High-Speed Integrated Circuit Hardware Description Language) and applied to Field-Programmable-GateArray (FPGA). The DT is embedded within the FPGA and contained in a controller board, the UCB (Unified Controller Board), developed by the University of Arkansas electrical engineering team. This UCB also contains two Digital Signal Processors (DSPs) responsible for generating associated signals to control an authentic physical inverter. These DSP signals are received and processed by the FPGA that implements the DT of an ANPC; in other words, it simulates in realtime the expected output of an actual ANPC inverter using the signals from the DSP. When a new firmware is ready to be patched, the DT provides output signals simulating behavior that a real ANPC inverter would generate with the new firmware. The new firmware is tested to check if it meets all the operational requirements established using a Design-For-Trust technique (DFTr). If the new firmware fails in at least one of the DFT tests, it is considered malicious and must be rejected. This work is divided into sections, such as Background, which explains the pieces that were used and the strategy behind this work; Process and Procedure, which explains the methodology that was adopted to prove the reliability and effectiveness of this work; Results and Discussion, where the simulations and results are described and explained; followed by Conclusion and Future work section, which concludes this work and adds possible future projects to continue this work further.

do Amaral Custodio, Paulo Vitor↗

Uncertainty Quantification of Bifacial Performance Modeling: Preprint

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗

Power Electronic Hardware-in-the-Loop (PE-HIL): Testing Individual Controllers in Large-Scale Power Electronics Systems

Large power electronics systems like multi-port autonomous reconfigurable solar power plant (MARS) are increasingly being researched upon to integrate emerging energy sources. MARS connects photovoltaic (PV) systems and energy storage systems (ESSs) to high-voltage direct current (HVdc) links/grids and high-voltage alternating current (ac) transmission grids. As these large power electronics systems incorporate complex hierarchical control systems that are close-by and communicate fast, the control systems require an unique power electronic hardware-in-the-loop (PE-HIL) real-time architecture to evaluate individual controllers. In this paper, a PE-HIL real-time architecture is proposed to evaluate one of the hundreds to thousands of digital signal processors (DSPs) that are a part of the complex hierarchical control system. The DSP connects to a central processing unit (CPU) and a field programmable gate array (FPGA) that form a part of the upper levels of the control system. The DSP is part of the lower level of the control system. The proposed PE-HIL architecture is tested and evaluated. Preliminary test results are presented to showcase the concept.

Debnath, Suman↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗

Hydroscanner: Instrumentation for Water Ingress Imaging in Photovoltaic Module Packaging Materials

A new iteration of the Hydroscanner prototype was designed and built during the execution of the contract. Compared to the previous designs, the communication port was changed from ethernet to USB C, since it provides a more seamless integration as a peripheral unit. An additional advantage is that one single port can be used for both communication and power up of the infrared camera. Although the power requirements are higher than the typical amount provided by a laptop computer, the camera can be run as a peripheral from a docking station when connected to a thunderbolt charging port. The software interface was modified to accommodate two imaging modes, an 8-bit and 14-bit image display. The 8-bit images use a custom colorization scheme that divides all pixels in the image into bins of equal width, such that images containing a wide range of brightness display the intermediate pixel intensities in greyscale values that enhance the contrast. The 14-bit images provide the direct readout from the focal plane array of the camera and can be saved as a text file for later processing in other software packages (MATLAB, Python).

47 OTHER INSTRUMENTATION↗

Measuring Irradiance for Bifacial PV Systems

The advent of bifacial PV systems drives new requirements for irradiance measurement at PV projects for monitoring and assessment purposes. While there are several approaches, there is still no uniform guidance for what irradiance parameters to measure and for the optimal selection and placement of irradiance sensors at bifacial arrays. Standards are emerging to address these topics but are not yet available. In this paper we review approaches to bifacial irradiance monitoring which are being discussed in the research literature and pursued in early systems, to provide a preliminary guide and framework for developers planning bifacial projects.

bifacial↗

Evaluation of Models and Measurements to Estimate Solar Radiation for 1-Axis Tracking Modules at NREL's SRRL: Preprint

Solar radiation reaching photovoltaic (PV) modules on a 1-axis tracking system can be measured by reference cells or thermopiles. The former is often biased due to the reflection of solar radiation by the glass cover of the PV. The uncertainty can be moderated by applying a correction factor, as a function of solar incident angle and the refractive index of the glass, to the measurement. On the other hand, solar radiation on the inclined PV panels can be computed by transposition models using global horizontal irradiance (GHI) observations from thermopiles. This study examines the models and measurements to estimate solar radiation for 1-axis tracking modules at National Renewable Energy Laboratory’s (NREL’s) Solar Radiation Research Laboratory (SRRL). The 1-minute plane-of-array (POA) irradiances in 2019 are computed using the observed GHIs and a transposition model developed by Perez et al. The POA irradiances are compared with the observation by an IMT reference cell and a Kipp & Zonen CM Pyranometer 22 (CMP22) thermopile. For SRRL’s 1-axis tracking system with the annual solar energy of 2323.9 kWh/m2, the POA irradiance is overestimated by ~70 kWh/m2 using the transposition model. This bias is reduced by more than 50% using the IMT measurements calibrated by a correction factor for a PV surface of antireflection coated glass.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evaluation of Models and Measurements to Estimate Solar Radiation for 1-Axis Tracking Modules at NREL’s SRRL

Solar radiation reaching photovoltaic (PV) modules on a 1-axis tracking system can be measured by reference cells or thermopiles. The former is often biased due to the reflection of solar radiation by the glass cover of the PV. The uncertainty can be moderated by applying a correction factor, as a function of solar incident angle and the refractive index of the glass, to the measurement. On the other hand, solar radiation on the inclined PV panels can be computed by transposition models using global horizontal irradiance (GHI) observations from thermopiles. This study examines the models and measurements to estimate solar radiation for 1-axis tracking modules at the National Renewable Energy Laboratory’s (NREL’s) Solar Radiation Research Laboratory (SRRL). The 1-minute plane-of-array (POA) irradiances from 2019 are computed using the observed GHIs and a transposition model developed by Perez et al. The POA irradiances are compared with the observation by an IMT reference cell and a Kipp & Zonen CM Pyranometer 22 (CMP22) thermopile. For the SRRL’s 1-axis tracking system with an annual solar energy of 2323.9 kWh/m 2 , the POA irradiance is overestimated by ~70 kWh/m 2 using the transposition model. This bias is reduced by more than 50% using the IMT measurements calibrated by a correction factor for a PV surface of antireflection coated glass.

POA irradiance↗

Validating Irradiance Models for High-Latitude Vertical Bifacial Photovoltaic Systems

Bifacial photovoltaic systems oriented vertically facing east-west are an emerging design, targeting production in morning and afternoon hours and providing competitive annual energy yield to traditional south-tilted modules for high latitude locations. The accuracy of existing bifacial PV models when modules are oriented vertically has yet to be examined in detail. Here, we compare four bifacial PV irradiance models in ~150 locations between 15-80 degrees N on the utility-scale, finding higher inter-model deviations for vertical PV systems than south-tilted across all latitudes less than 75 degrees N. We validate model-predicted irradiance with test-site data collected in Golden, Colorado and Fairbanks, Alaska for E-W vertical and south-tilted arrays. View factor models agree with E-W vertical test-site data in Golden with RMSE=15%. Modelling error increases for the Alaskan test-site to RMSE values between 21-30%, driven in part by high albedo measurement uncertainty during snowy months.

bifacial↗