Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pixel array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Sharp Infrared Eyes The Journey of QWIPs from Concept to Large Inexpensive Sensitive Arrays in Hand-held Infrared Cameras

One of the simplest device realizations of the classic particle-in-a-box problem of basic quantum mechanics is the Quantum Well Infrared Photodetector (QWIP). Optimization of the detector design and material growth and processing has culminated in the realization of a camera with a large (256x256 pixel) focal plane array of QWIPs which can see at 8.5 mu m, holding forth great promise for a variety of applications in the 6-25 mu m wavelength range.

Quantum Well Infrared Photodetector QWIP quantum m↗

BIG MAC: A bolometer array for mid-infrared astronomy, Center Director's Discretionary Fund

The infrared array referred to as Big Mac (for Marshall Array Camera), was designed for ground based astronomical observations in the wavelength range 5 to 35 microns. It contains 20 discrete gallium-doped germanium bolometer detectors at a temperature of 1.4K. Each bolometer is irradiated by a square field mirror constituting a single pixel of the array. The mirrors are arranged contiguously in four columns and five rows, thus defining the array configuration. Big Mac utilized cold reimaging optics and an up looking dewar. The total Big Mac system also contains a telescope interface tube for mounting the dewar and a computer for data acquisition and processing. Initial astronomical observations at a major infrared observatory indicate that Big Mac performance is excellent, having achieved the design specifications and making this instrument an outstanding tool for astrophysics.

Telesco, C. M.↗

Decoding techniques for fine-fine geometry multi-anode microchannel arrays

The Multi-Anode Microchannel Array (MAMA) is a photon-counting detector which decodes the position of an event through coincidence discrimination. The decoding algorithm which associates a given event with the appropriate pixel is determined by the geometry of the array. The decoding process can be divided into two tasks: anode encoding and pixel decoding. Techniques for performing both tasks are described and contrasted in light of application requirements. Decode times of 75 nanoseconds have been achieved, and considerably faster decoders are possible given new architectures and technologies.

Kasle, David B.↗

Ultra Low Power Imaging Systems Using CMOS Image Sensor Technology

The need for miniaturization in advanced science sensor systems has led to the development of a new image sensor technology, the active pixel image sensor (APS). The development of CMOS APS technology allows the integration of timing and control electronics, imaging detector arrays, signal chains and analog-to-digital conversion on a single integrated circuit. The impact on the imaging system is to reduce power by approximately 1000x over existing systems - from tens of watts to tens of milliwatts.

imaging↗

Performance of a broad-band, high-resolution, transition-edge sensor spectrometer for x-ray astrophysics

Future x-ray astrophysics experiments require multiplexed readout of high-fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo pixel array of Mo/Au TESs read out with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA’s Athena X-IFU, and when complete will used to laboratory astrophysics experiments. Our array and TDM readout has demonstrated a combined energy resolution, including > 200 pixels, of: 1.95 eV for Ti-K (4.5 keV), 1.97 eV for Mn-K (5.9 keV), 2.16 eV for Co-Kα (6.9 keV), 2.33 eV for Cu-Kα (8 keV), 3.26 eV for Br-Kα (11.9 keV). The 1 sigma error is  0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU.

Stephen J. Smith↗

Focal Plane Arrays of Voltage-Biased Superconducting Bolometers

The 200-micrometer to 3-mm wavelength range has great astronomical and cosmological significance. Science goals include characterization of the cosmic microwave background, measurement of the Sunyaev-Zel'dovich effect in galaxy clusters, and observations of forming galaxies. Cryogenic bolometers are the most sensitive broadband detectors in this frequency range. Because single bolometer pixels are reaching the photon noise limit for many observations, the development of large arrays will be critical for future science progress. Voltage-biased superconducting bolometers (VSBs) have several advantages compared to other cryogenic bolometers. Their strong negative electrothermal feedback enhances their linearity, speed, and stability. The large noise margin of the SQUID readout enables multiplexed readout schemes, which are necessary for developing large arrays. In this paper, we discuss the development of a large absorber-coupled array, a frequency-domain SQUID readout multiplexer, and an antenna-coupled VSB design.

Myers, Michael J.↗

TES-Based X-Ray Microcalorimeter Performances Under AC Bias and FDM for Athena

Athena is a European X-ray observatory, scheduled for launch in 2028. Athena will employ a high-resolution imaging spectrometer called X-ray integral field unit (X-IFU), consisting of an array of 4000 transition edge sensor (TES) microcalorimeter pixels. For the readout of X-IFU, we are developing frequency domain multiplexing, which is the baseline readout system. In this paper, we report on the performance of a TES X-ray calorimeter array fabricated at Goddard Space Flight Center (GSFC) at MHz frequencies for the baseline of X-IFU detector. During single-pixel AC bias characterization, we measured X-ray energy resolutions (at 6 keV) of about 2.9 eV at both 2.3 and 3.7 MHz. Furthermore, in the multiplexing mode, we measured X-ray energy resolutions of about 2.9 eV at 1.3 and 1.7 MHz.

Transition edge sensors X-ray microcalorimeter Fre↗

Development of Tiled Imaging CZT Detectors for Sensitive Wide-Field Hard X-Ray Surveys to EXIST

Motivated by the proposed EXIST mission, a "medium-class" space observatory to survey black holes and the Early Universe proposed to the 2010 NAS/NRC Astronomy and Astrophysics Decadal Survey, we have developed the first "large" area 256 sq cm close-tiled (0.6 mm gaps) hard X-ray (20-600 keV) imaging detector employing pixelated (2.5 mm) CdZnTe (CZT) detectors, each 2 x 2 x 0.5 cubic cm. We summarize the design, development and operation of this detector array (8 x 8 CZTs) and its performance as the imager for a coded aperture telescope on a high altitude (40 km) balloon flight in October. 2009, as the ProtoEX1STl payload. We then outline our current development of a second-generation imager, ProtcEXIST2. with 0.6 mm pixels on a 32 x 32 array on each CZT, and how it will lead to the ultimate imaging system needed for EXIST. Other applications of this technology will also be mentioned.

Grindlay, J.↗

Performance Assessment of the Optical Transient Detector and Lightning Imaging Sensor: Predicted Diurnal Variability - 1

Laboratory calibration and observed background radiance data are used to determine the effective sensitivities of the Optical Transient Detector and Lightning Imaging Sensor, as functions of local hour and pixel location within the instrument arrays. The effective LIS thresholds, expressed as radiances emitted normal to cloud top, are 4.0 plus or minus 0.7 and 7.6 plus or minus 3.3 micro J/ster/m (sup 2) for night and local noon; the OTD thresholds am 11.7 plus or minus 2.2 and 16.8 plus or minus 4.6 microJ/ster/m (sup 2). LIS and OTD minimum signal to noise ratios occur from 0800 to 1600 local time, and attain values of 10 plus or minus 2 and 20 plus or minus 3, respectively. False alarm rate due to instrument noise yields approximately 5 false triggers per month for LIS, and is negligible for OTD. Flash detection efficiency, based on prior optical pulse sensor measurements, is predicted to be 93 plus or minus 4% and 73 plus or minus 11% for LIS night and noon; 56 plus or minus 7% and 44 plus or minus 9% for OTD night and noon, corresponding to a 12 - 20% diurnal variability and LIS:OTD ratio of 1.7. Use of the weighted daily mean detection efficiency (i.e., not controlling for local hour) corresponds to a sigma = 8 - 9% uncertainty. These are likely overestimates of actual flash detection efficiency due to differences in pixel ground field-of-view across the instrument arrays, which are not accounted for in the validation optical pulse sensor data.

Boccippio, Dennis J.↗

Transition-Edge Sensor Pixel Parameter Design of the Microcalorimeter Array for the X-Ray Integral Field Unit on Athena

The focal plane of the X-ray integral field unit (X-IFU) for ESA's Athena X-ray observatory will consist of approximately 4000 transition edge sensor (TES) x-ray microcalorimeters optimized for the energy range of 0.2 to 12 kiloelectronvolts. The instrument will provide unprecedented spectral resolution of approximately 2.5 electronvolts at energies of up to 7 kiloelectronvolts and will accommodate photon fluxes of 1 milliCrab (90 counts per second) for point source observations. The baseline configuration is a uniform large pixel array (LPA) of 4.28 arcseconds pixels that is read out using frequency domain multiplexing (FDM). However, an alternative configuration under study incorporates an 18 by × 18 small pixel array (SPA) of 2 arcseconds pixels in the central approximately 36 arcseconds region. This hybrid array configuration could be designed to accommodate higher fluxes of up to 10 milliCrabs (900 counts per second) or alternately for improved spectral performance (less than 1.5 electronvolts) at low count-rates. In this paper we report on the TES pixel designs that are being optimized to meet these proposed LPA and SPA configurations. In particular we describe details of how important TES parameters are chosen to meet the specific mission criteria such as energy resolution, count-rate and quantum efficiency, and highlight performance trade-offs between designs. The basis of the pixel parameter selection is discussed in the context of existing TES arrays that are being developed for solar and x-ray astronomy applications. We describe the latest results on DC biased diagnostic arrays as well as large format kilo-pixel arrays and discuss the technical challenges associated with integrating different array types on to a single detector die.

Smith, S. J.↗

Efficient Mirrorlet Array Based Integral Field Spectrometer (IFS) for HWO

Habitable World Observatory (HWO) is a NASA strategic mission recommended by 2020 astronomical decadal survey. Integral field spectrometers play an important role to verify if the observed exoplanet is habitable. The traditional lenslet array based IFS has the advantage of simplicity and compactness. However, it does not use detector pixels efficiently in order to prevent wavelength crosstalk among adjacent spectra. The efficient lenslet/mirrorlet IFS combines the advantages from both lenslet based and imager slicer based IFSes—keeping lenslet IFS’s simplicity and compactness, and adding slicer IFS’s detector efficiency. This paper discusses the principle of efficient lenslet/mirrorlet IFS, design philosophy, and efficient spectral trace layout ideals. It uses HWO NIR IFS requirement as an example to provide an efficiency mirrorlet IFS optical design. The high detector efficiency not only reduces needed detector pixel numbers, but also reduces the high communication rate demanding for such a large multiple instrument mission.

Qian Gong↗

Performance of a broad-band, high-resolution, transition-edge sensor spectrometer for X-ray astrophysics

Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA’s Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including >200 pixels, of:1.95 eV for Ti-Ka(4.5 keV), 1.97eV for Mn-Ka(5.9 keV), 2.16 eV for Co-Kα(6.9 keV),2.33 eV for Cu-Kα(8 keV), 3.26 eV for Br-Kα(11.9 keV). The 1 sigma statistical errorsare£0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.

S J Smith↗

High Performance GaN/AlGaN Ultraviolet Avalanche Photodiode Detector Technologies

Detection of ultraviolet (UV) bands provides distinct advantages for NASA, defense, and commercial applications, including increased spatial resolution, small pixel sizes, and large format arrays. AlxGa1-xN semiconductor alloys have attracted great interest for detection in the UV spectral region because of their potential for high optical gain, high sensitivity, and low dark current performance in ultraviolet avalanche photodiodes (UV-APDs). We are developing GaN/AlGaN UV-APDs that demonstrate consistent and reliable UV-APD performance and operation. For these UV detectors we have measured gains of above 5×10(exp 6) and high quantum efficiencies at ~350 nm enabled by a strong avalanche multiplication process. These UV-APDs are fabricated through high quality metal organic chemical vapor deposition (MOCVD) growth on lattice-matched, low dislocation density GaN substrates with optimized GaN/AlGaN UV-APD material growth and doping parameters. The high performance, variable-area GaN/AlGaN UV-APD detectors and arrays can be customized to a wide variety of sizes including large-area formats to enable sensing and high-resolution detection over UV bands of interest.

Sood, Ashok K.↗

Photon detection with parallel asynchronous processing

An approach to photon detection with a parallel asynchronous signal processor is described. The visible or IR photon-detection capability of the silicon p(+)-n-n(+) detectors and the parallel asynchronous processing are addressed separately. This approach would permit an independent analog processing channel to be dedicated to every pixel. A laminar architecture consisting of a stack of planar arrays of the devices would form a 2D array processor with a 2D array of inputs located directly behind a focal-plane detector array. A 2D image data stream would propagate in neuronlike asynchronous pulse-coded form through the laminar processor. Such systems can integrate image acquisition and image processing. Acquisition and processing would be performed concurrently as in natural vision systems. The possibility of multispectral image processing is addressed.

Coon, D. D.↗

The X-ray Microcalorimeter Spectrometer (XMS): A Reference Cryogenic Instrument Design for Constellation-X

Constellation-X, a mission now belonging to the Beyond Einstein initiative, is being planned to inherit the x-ray sky from Chandra, XMM-Newton and Astro-E. The first two of four observatories in the constellation will be launched together in 2013 and followed a year later by the launch of the remaining two. The four will independently orbit the Sun-Earth Lagrange point L2. An instrument compliment resides in the Focal Plane Module (FPM) of each observatory 10 m from the Optics Module and consists of three Hard X-ray Telescope (HXT) detectors, a Reflection Grating Spectrometer (RGS) focal plane CCD camera and an X-ray Microcalorimeter Spectrometer (XMS). Instrument awards are scheduled for early 2006. The reference detector for XMS is a 32 x 32 array of microcalorimetric superconducting Transition Edge Sensors (TES). Each pixel casts a variable resistance in a SQUID based multiplexed readout circuit which is coupled to series SQUID arrays for amplification and finally read out by external electronics. A multi-stage continuous ADR will provide the stable 50 mK desired for the TES array and a stable 1 K for the series SQUID arrays while also lifting thermal parasitic and inefficiency loads to a 6 K cryocooler interface. The 6 K cryocooler is expected to emerge from the joint-project Advanced Cryocooler Technology Development Program (ACTDP) in which Constellation-X is an active participant. Project Pre-Formulation activities are marked by extensive technology development necessitating early, but realistic, thermal and cooling load requirements for ADR and ACTDP-cryocooler design points. Such requirements are driven by the encompassing XMS cryostat and ultimately by the thermal environment imposed by the FPM. It is further desired that the XMS instrument be able to operate on its side in the laboratory, with a warm vacuum shell, during an extensive calibration regime. It is that reference system design of the XMS instrument (microcalorimeter, ADR, cryocooler and cryostat) which is the subject of this paper.

Whitehouse, Paul L.↗

Superconducting kinetic inductance photon detectors.

We are investigating a novel superconducting detector and readout method that could lead to photon counting, energy resolving focal plane arrays. This concept is intrinsically different from STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution in the ptical/UV/X-ray bands. The readout uses the monotonic relation between the kinetic surface inductance L***subs***, of a superconductor and the density of quasiparticles n, which holds even at temperatures far below T***subc***. This allows a sensitive readout of the number of excess quasiparticles in the detector by monitoring the transmission phase of a resonant circuit. The most intriguing aspect of this concept is that passive frequency multiplexing could be used to read out ~ l0***super4*** detectors with a single HEMT amplifier. Single x-ray events have been observed in prototype detectors.

kinetic↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Si:Bi switched photoconducttor infrared detector array

A multiplexed infrared detector array is described. The small demonstration prototype consisted of two cryogenically cooled, bismuth doped silicon, extrinsic photoconductor pixels multiplexed onto a single output channel using an on focal plane switch integration sampling technique. Noise levels of the order of 400 to 600 rms electrons per sample were demonstrated for this chip and wire hybrid version.

Eakin, C. E.↗