Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma Volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Biomedical support of man in space

The effects of G and/or exercise on cardiopulmonary adjustments to stresses are studied. The control of the cardiopulmonary system is examined using simulated microgravity (recumbency, immersion, lower body positive pressure, and 6-deg head-down tilt) and increased acceleration. It is observed that at rest and during exercise in simulated zero-6 environments, the stroke volume and cardiac output are initially increased and then (after prolonged exposure) return to prezero-G levels. Cardiovascular responses to increased gravity (1, 2, and 3 G) at rest and during exercise are analyzed; a decrease in plasma volume resulting in decreases in stroke volume and cardiac output, and an increase in heart rate are detected.

Pendergast, D. R.↗

Body fluid alterations during head-down bed rest in men at moderate altitude

To determine the effects of hypoxia on fluid balance responses to simulated zero-gravity, measurements were made in six subjects before and during -5 deg continuous head-down bed rest (HDBR) over 8 d at 10,678 ft. The same subjects were studied again at this altitude without HDBR as a control (CON) using a cross-over design. During this time, they maintained normal upright day-time activities, sleeping in the horizontal position at night. Fluid balance changes during HDBR in hypoxia were more pronounced than similar measurements previously reported from HDBR studies at sea level. Plasma volume loss was slightly greater and the diuresis and natriuresis were doubled in magnitude as compared to previous studies in normoxia and sustained for 4 d during hypoxia. These changes were associated with an immediate but transient rise in plasma atrial natriuretic peptide (ANP) to day 4 of 140 percent in HDBR and 41 percent in CON (p less than 0.005), followed by a decline towards baseline. Differences were less striking between HDBR and CON for plasma antidiuretic hormone and aldosterone, which were transiently reduced by HDBR. Plasma catecholamines showed a similar pattern to ANP in both HDBR and CON, suggesting that elevated ANP and catecholamines together accounted for the enhanced fluid shifts with HDBR during hypoxia.

Loeppky, J. A.↗

Early Fluid and Protein Shifts in Men During Water Immersion

High precision blood and plasma densitometry was used to measure transvascular fluid shifts during water immersion to the neck. Six men (28-49 years) undertook 30 min of standing immersion in water at 35.0 +/- 0.2 C; immersion was preceded by 30 min control standing in air at 28 +/- 1 C. Blood was sampled from an antecubital catheter for determination of Blood Density (BD), Plasma Density (PD), Haematocrit (Ht), total Plasma Protein Concentration (PPC), and Plasma Albumin Concentration (PAC). Compared to control, significant decreases (p less than 0.01) in all these measures were observed after 20 min immersion. At 30 min, plasma volume had increased by 11.0 +/- 2.8%; the average density of the fluid shifted from extravascular fluid into the vascular compartment was 1006.3 g/l; albumin moved with the fluid and its albumin concentration was about one-third of the plasma protein concentration during early immersion. These calculations are based on the assumption that the F-cell ratio remained unchanged. No changes in erythrocyte water content during immersion were found. Thus, immersion-induced haemodilution is probably accompanied by protein (mainly albumin) augmentation which accompanies the intra-vascular fluid shift.

Hinghofer-Szalkay, H.↗

Marked Exacerbation of Orthostatic Intolerance After Long vs. Short-Duration Spaceflight in Veteran Astronauts

The incidence of postflight orthostatic intolerance following short-duration spaceflight is about 20%. However, the incidence following long-duration spaceflight is unknown. We performed tilt tests on six astronauts before and after their long-duration (129 - 190 days) spaceflights and compared these data to those obtained during stand tests before and after their previous short-duration missions and also to tilt test data from 20 different short-duration (8 - 16 days) flight astronauts. Five of these six became presyncopal during tilt testing after long-duration flights: only one had become presyncopal during stand testing after short-duration flights. Five of the twenty astronauts who flew on other short-duration flights, became presyncopal during upright tilt on landing day. Long-duration presyncopal subjects had lower stroke volumes, lower cardiac outputs and higher peripheral vascular resistance than short-duration presyncopal subjects, but their heart rate responses were not different. One subject had subnormal norepinephrine release with upright posture after a long but not short flight. Plasma volume losses were not greater after long flights. Long-duration spaceflight markedly increases orthostatic intolerance, probably related to altered autonomic function.

Fritsch-Yelle, Janice M.↗

Exercise Versus +Gz Acceleration Training

Decreased working capacity and "orthostatic" intolerance are two major problems for astronauts during and after landing from spaceflight in a return vehicle. The purpose was to test the hypotheses that (1) supine-passive-acceleration training, supine-interval-exercise plus acceleration training, and supine exercise plus acceleration training will improve orthostatic tolerance (OT) in ambulatory men; and that (2) addition of aerobic exercise conditioning will not influence this enhanced OT from that of passive-acceleration training. Seven untrained men (24-38 yr) underwent 3 training regimens (30 min/d x 5d/wk x 3wk on the human-powered centrifuge - HPC): (a) Passive acceleration (alternating +1.0 Gz to 50% Gzmax); (b) Exercise acceleration (alternating 40% - 90% V02max leg cycle exercise plus 50% of HPCmax acceleration); and (c) Combined intermittent exercise-acceleration at 40% to 90% HPCmax. Maximal supine exercise workloads increased (P < 0.05) by 8.3% with Passive, by 12.6% with Exercise, and by 15.4% with Combined; but maximal V02 and HR were unchanged in all groups. Maximal endurance (time to cessation) was unchanged with Passive, but increased (P < 0.05) with Exercise and Combined. Resting pre-tilt HR was elevated by 12.9% (P < 0.05) only after Passive training, suggesting that exercise training attenuated this HR response. All resting pre-tilt blood pressures (SBP, DBP, MAP) were not different pre- vs. post-training. Post-training tilt-tolerance time and HR were increased (P < 0.05) only with Passive training by 37.8% and by 29.1%, respectively. Thus, addition of exercise training attenuated the increased Passive tilt tolerance. Resting (pre-tilt) and post-tilt cardiac R-R interval, stroke volume, end-diastolic volume, and cardiac output were all uniformly reduced (P < 0.05) while peripheral resistance was uniformly increased (P < 0.05) pre-and post-training for the three regimens indicating no effect of any training regimen on those cardiovascular variables. Plasma volume (% delta) was uniformly decreased by 8% to 14% (P < 0.05) at tilt-tolerance pre- vs. post-training for all regimens indicating no effect of these training regimens on the level of vascular fluid shifts.

Greenleaf, John E.↗

Hypovolemia Induced Orthostatic Hypotension in Presyncopal Astronauts and Normal Subjects Relates to Hypo-Sympathetic Responsiveness

Circulating blood volume is reduced during spaceflight, leaving astronauts hemodynamically compromised after landing. Because of this hypovolemia, crew members are able to withstand a postflight 10 minute upright tilt test only if they are able to mount a hyper-sympathetic response. Previous work from this laboratory has shown that about 30% of astronauts, primarily female, have postflight sympathetic responses to tilt that are equal to or less than their preflight responses and thus, they become presyncopal. Part of the mission of the cardiovascular lab at the Johnson Space Center is to identify susceptible crewmembers before flight so that individualized countermeasures can be prescribed. The goal of this study was to develop a ground based model of hypovolemia that could be used for this purpose We tested the hypothesis that hypovolemia alone, in the absence of spaceflight, would reproduce the landing day rate of presyncope during upright tilt in normal volunteers. Further, we hypothesized that, during hypovolemia, subjects who had sympathetic responses that were equal to or less than their normovolemic responses would become presyncopal during upright tilt tests. We studied 20 subjects, 13 male and 7 female, on two separate occasions: during normovolemia and hypovolemia. We induced hypovolemia with intravenous furosemide 40 hours prior to the experiment day, followed by a 10MEq Na diet. On the normovolemia and hypovolemia test days, plasma volume, tilt tolerance and supine and standing arterial pressure, heart rate and plasma norepinephrine levels were measured. A two factor, repeated measures analysis of variance was performed to examine the differences between group (presyncopal vs. non-presyncopal) and day (normovolemia vs. hypovolemia) effects. There were no differences in baseline arterial pressure between normovolemia and hypovolemia or between presyncopal and non-presyncopal groups, but heart rates were higher with hypovolemia in both groups (presyncopal: 70 5 bpm vs. 63 3 bpm, P = 0.003, non-presyncopal: 59 2 bpm vs. 52 2 bpm, P = 0.003). Similar to patterns reported after flight, non-presyncopal subjects had greater norepinephrine responses to tilt during hypovolemia compared to normovolemia (580 79 vs. 298 37 pg/ml, P < 0.05), but presyncopal subjects did not (180 44 vs. 145 32 pg/ml, P = NS). This new model has the potential to accelerate the development of countermeasures and save flight resources. It can be used to identify astronauts who will become presyncopal on landing day, so that prospective, individualized countermeasures can be developed. In addition, it can also be used to screen candidate countermeasures prior to requests for bed rest or inflight resources.

Meck, Janice V.↗

Computer simulation of the effect of dDAVP with saline loading on fluid balance after 24-hour head-down tilt

Fluid loading (FL) before Shuttle reentry is a countermeasure currently in use by NASA to improve the orthostatic tolerance of astronauts during reentry and postflight. The fluid load consists of water and salt tablets equivalent to 32 oz (946 ml) of isotonic saline. However, the effectiveness of this countermeasure has been observed to decrease with the duration of spaceflight. The countermeasure's effectiveness may be improved by enhancing fluid retention using analogs of vasopressin such as lypressin (LVP) and desmopressin (dDAVP). In a computer simulation study reported previously, we attempted to assess the improvement in fluid retention obtained by the use of LVP administered before FL. The present study is concerned with the use of dDAVP. In a recent 24-hour, 6 degree head-down tilt (HDT) study involving seven men, dDAVP was found to improve orthostatic tolerance as assessed by both lower body negative pressure (LBNP) and stand tests. The treatment restored Luft's cumulative stress index (cumulative product of magnitude and duration of LBNP) to nearly pre-bedrest level. The heart rate was lower and stroke volume was marginally higher at the same LBNP levels with administration of dDAVP compared to placebo. Lower heart rates were also observed with dDAVP during stand test, despite the lower level of cardiovascular stress. These improvements were seen with only a small but significant increase in plasma volume of approximately 3 percent. This paper presents a computer simulation analysis of some of the results of this HDT study.

NASA Discipline Cardiopulmonary↗

Optimization of quasi-axisymmetric stellarators with varied elongation

An optimization study of Quasi-Axisymmetric (QA) stellarators with varied elongation has been carried out using the optimization code STELLOPT. The starting point of our optimization is a previously obtained QA stellarator with 3 field periods and aspect ratio of 6. Here, a series of QA stellarators are obtained at zero plasma beta with varied elongation value ranging from 2.5 to 3.7. Good quasi-symmetry is kept when the elongation value is reduced from the original value of 3.7. The rotational transform profile and aspect ratio are kept fixed. The plasma volume is ether kept fixed or varied linearly with elongation. Furthermore, finite beta QA stellarators are considered. The corresponding bootstrap currents are calculated using the kinetic code SFINCS. A series of kink-stable QA stellarators are obtained via optimization with varied plasma beta up to 5% and self-consistent bootstrap current. This work demonstrates that good QA stellarators with finite beta and varied elongation exist that are stable to external kink modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Omnigenous umbilic stellarators

To better understand the dependence of the magnetic field structure in the plasma edge on the plasma boundary shape, in the context of X-point and island divertor designs, we define and develop a class of stellarators called umbilic stellarators. These equilibria are characterised by a single continuous high-curvature edge on the plasma boundary that goes around multiple times toroidally before meeting itself. We develop a technique that allows us to simultaneously optimise the plasma boundary along with a curve lying on the boundary on which we impose a high curvature while imposing omnigenity – a property of the magnetic field that ensures trapped particle confinement throughout the plasma volume. We find that umbilic stellarators naturally tend to favour piecewise omnigenity instead of omnigenity with a specific helicity. After generating omnigenous umbilic stellarators, we design coil sets for some of them and explore the fieldline structure in the edge and its sensitivity to small fluctuations in the plasma. Finally, using single-stage optimisation, we simultaneously modify the plasma and coil shape and propose an experiment to modify an existing tokamak to a finite-𝛽 stellarator using this technique and explore a potentially simpler way to convert a limited tokamak into a diverted stellarator.

fusion plasma↗

Deterioration of left ventricular chamber performance after bed rest : "cardiovascular deconditioning" or hypovolemia?

BACKGROUND: Orthostatic intolerance after bed rest is characterized by hypovolemia and an excessive reduction in stroke volume (SV) in the upright position. We studied whether the reduction in SV is due to a specific adaptation of the heart to head-down tilt bed rest (HDTBR) or acute hypovolemia alone. METHODS AND RESULTS: We constructed left ventricular (LV) pressure-volume curves from pulmonary capillary wedge pressure and LV end-diastolic volume and Starling curves from pulmonary capillary wedge pressure and SV during lower body negative pressure and saline loading in 7 men (25+/-2 years) before and after 2 weeks of -6 degrees HDTBR and after the acute administration of intravenous furosemide. Both HDTBR and hypovolemia led to a similar reduction in plasma volume. However, baseline LV end-diastolic volume decreased by 20+/-4% after HDTBR and by 7+/-2% after hypovolemia (interaction P<0.001). Moreover, SV was reduced more and the Starling curve was steeper during orthostatic stress after HDTBR than after hypovolemia. The pressure-volume curve showed a leftward shift and the equilibrium volume of the left ventricle was decreased after HDTBR; however, after hypovolemia alone, the curve was identical, with no change in equilibrium volume. Lower body negative pressure tolerance was reduced after both conditions; it decreased by 27+/-7% (P<0.05) after HDTBR and by 18+/-8% (P<0.05) after hypovolemia. CONCLUSIONS: Chronic HDTBR leads to ventricular remodeling, which is not seen with equivalent degrees of acute hypovolemia. This remodeling leads to a greater decrease in SV during orthostatic stress after bed rest than hypovolemia alone, potentially contributing to orthostatic intolerance.

NASA Discipline Cardiopulmonary↗

Control of intense light with avalanche-ionization plasma gratings

High-peak-power lasers are fundamental to high-field science: increased laser intensity has enabled laboratory astrophysics, relativistic plasma physics, and compact laser-based particle accelerators. However, the meter-scale optics required for multi-petawatt lasers to avoid light-induced damage make further increases in power challenging. Plasma tolerates orders-of-magnitude higher light flux than glass, but previous efforts to miniaturize lasers by constructing plasma analogs for conventional optics were limited by low efficiency and poor optical quality. We describe a new approach to plasma optics based on avalanche ionization of atomic clusters that produces plasma volume transmission gratings with dramatically increased diffraction efficiency. We measure an average efficiency of up to 36% and a single-shot efficiency of up to 60%, which is comparable to key components of high-power laser beamlines, while maintaining high spatial quality and focusability. These results suggest that plasma diffraction gratings may be a viable component of future lasers with peak power beyond 10 PW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deconditioning and Reconditioning: Humans in Stressful Environments

Deconditioning is an integrated physiological response of the body to a reduction in metabolic rate; that is, to a reduction in energy use or in exercise level. While it may involve assumption of a horizontal body position, it certainly perturbs bodily homeostasis - at least temporarily. The reduction in physical activity that causes deconditioning is often associated with an increase in the time spent, for whatever reason, in a sitting or horizontal position. As a result, orthostatic factors may also contribute to the deconditioning mechanism. The word decondition may be defined as "1: to cause extinction of (a conditioned response) 2: to cause to lose physical fitness". This definition implies that psychological/emotional factors may accompany physical deconditioning, and it is this interpretation of the word that is used throughout this volume. It is apparent that deconditioning plays a major role in the mechanism of the general adaptive (homeostatic) response that is initiated by exposure to prolonged bed rest (BR). And the total homeostatic response to BR involves more than deconditioning per se. For example, it has been shown that the restoration of plasma volume and maximal work capacity after 4 weeks of BR deconditioning left other bodily functions (submaximal exercise oxygen uptake and cardiac output, leg proprioception and posterior leg muscle thickness and volume, head-up tilt tolerance, and sleep quality) functioning at decreased levels. The precise effect of deconditioning on BR homeostasis is difficult to determine, because the fundamental interactive neuro-endocrine-immune control networks that facilitate conditioning and deconditioning also act to maintain basic wholebody homeostasis. For example, is the mechanism of BR-induced deconditioning independent of the mechanism that provokes concomitant orthostatic intolerance; that is, fainting? Assumption of the recumbent body position for prolonged periods of time, results in a new adaptive-homeostatic state. This state occurs in response to the mutually interactive effects of the change in bodily position (hydrostatic pressure), to the virtual elimination of longitudinal pressure on the bones, to the increased confinement with possible reduction in total daily energy (exercise) expenditure, to the reorientation of stimuli within the vestibular organs, and (often) to altered socio-psychological conditions. The exercise-training (reconditioning) syndrome affects total body homeostasis by facilitating increases in work capacity and endurance, whereas deconditioning decreases physical performance. There are many interrelated factors that influence the control parameters that seek to maintain the adaptive conditioning-deconditioning syndrome. These control parameters can be better elucidated by subjecting otherwise healthy ambulatory people to various stresses, such as exercise training and prolonged spaceflight, bed rest, water immersion, hyperbaria, and isolation and confinement. Changes in control parameters will be manifested in muscle function, orthostatic tolerance, cardiorespiratory responses, musculo-skeletal systems, free-radical processes, and body thermoregulation with overarching effects on the subjects' psycho-sociological states. A discussion of these factors and the control parameters constitutes the substance of this volume. Special emphasis is placed on delineating practical applications of the findings that will be of special interest to physicians, nurses, and other health-care workers.

Greenleaf, John E.↗

Inputs and Outputs for paper "The DESC stellarator code suite. Part 1. Quick and accurate equilibria computations"

Contains the DESC and VMEC input and output files used in the paper, as well as the plotting scripts used to create the figures in the paper (Current with the arXiv Mar 31 2022 version, https://arxiv.org/abs/2203.17173v1): 3D equilibrium codes are vital for stellarator design and operation, and high-accuracy equilibria are also necessary for stability studies. This paper details comparisons of two 3D equilibrium codes, VMEC, which uses a steepest-descent algorithm to reach a minimum-energy plasma state, and DESC, which minimizes the MHD force error in real space directly. Accuracy as measured by final plasma energy and satisfaction of MHD force balance, as well as other metrics, will be presented for each code, along with the computation time. It is shown that DESC is able to achieve more accurate solutions, especially near-axis. DESC's global Fourier-Zernike basis also yields the solution everywhere in the plasma volume, not just on discrete flux surfaces. Further, DESC can compute the same accuracy solution as VMEC in an order of magnitude less time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of Gravity on Blood Volume and Flow Distribution

In our previous experiments during NASA Shuttle flights SLS 1 and 2 (9-15 days) and EUROMIR flights (30-90 days) we observed that pulmonary blood flow (cardiac output) was elevated initially, and surprisingly remained elevated for the duration of the flights. Stroke volume increased initially and then decreased, but was still above 1 Gz values. As venous return was constant, the changes in SV were secondary to modulation of heart rate. Mean blood pressure was at or slightly below 1 Gz levels in space, indicating a decrease in total peripheral resistance. It has been suggested that plasma volume is reduced in space, however cardiac output/venous return do not return to 1 Gz levels over the duration of flight. In spite of the increased cardiac output, central venous pressure was not elevated in space. These data suggest that there is a change in the basic relationship between cardiac output and central venous pressure, a persistent "hyperperfusion" and a re-distribution of blood flow and volume during space flight. Increased pulmonary blood flow has been reported to increase diffusing capacity in space, presumably due to the improved homogeneity of ventilation and perfusion. Other studies have suggested that ventilation may be independent of gravity, and perfusion may not be gravity- dependent. No data for the distribution of pulmonary blood volume were available for flight or simulated microgravity. Recent studies have suggested that the pulmonary vascular tree is influenced by sympathetic tone in a manner similar to that of the systemic system. This implies that the pulmonary circulation is dilated during microgravity and that the distribution of blood flow and volume may be influenced more by vascular control than by gravity. The cerebral circulation is influenced by sympathetic tone similarly to that of the systemic and pulmonary circulations; however its effects are modulated by cerebral autoregulation. Thus it is difficult to predict if cerebral perfusion is increased and if there is edema in space. Anecdotal evidence suggests there may be cerebral edema early in flight. Cerebral artery velocity has been shown to be elevated in simulated microgravity. The elevated cerebral artery velocity during simulated microgravity may reflect vasoconstriction of the arteries and not increased cerebral blood flow. The purpose of our investigations was to evaluate the effects of alterations in simulated gravity (+/-), resulting in changes in cardiac output (+/-), and on the blood flow and volume distribution in the lung and brain of human subjects. The first hypothesis of these studies was that blood flow and volume would be affected by gravity, but their distribution in the lung would be independent of gravity and due to vasoactivity changing vascular resistance in lung vessels. The vasodilitation of the lung vasculature (lower resistance) along with increased "compliance" of the heart could account for the absence of increased central venous pressure in microgravity. Secondly, we postulate that cerebral blood velocity is increased in microgravity due to large artery vasoconstriction, but that cerebral blood flow would be reduced due to autoregulation.

Pendergast, D.↗

Performance characteristics of a microwave plasma disk ion source

The development, design, and preliminary performance characteristics of a microwave plasma disk ion source are presented. Several important design concepts indigenous to microwave plasmas have been utilized in the development of this ion source: generation of a resonantly sustained microwave discharge inside a microwave/plasma coupler, probe and length tuning of the microwave/plasma coupler, and minimization of plasma volume. The experimental results for a 2.45 GHz, eight cm ion source excited in the TE(211) and TM(011) modes are described. Results are presented for electromagnetic mode excitation, electron density, coupling efficiency and loaded cavity Q, and I-V characteristics and efficiencies. It is preliminarily shown that a microwave disk-like plasma can be sustained adjacent to the grids with either TE or TM cavity modes at pressures below 2 x 10 to the -4th torr. Over 80% of the power absorbed in the cavity is coupled into the plasma.

Asmussen, J.↗

Carotid-cardiac baroreflex: Relation with orthostatic hypotension following simulated microgravity and implications for development of countermeasures

In a series of studies, we have examined the effects of exposure to simulated microgravity, varying states of vascular volume, and acute exercise on the function of the carotid-cardiac baroreflex in man. In the first study, exposure to simulated microgravity (6 degree headdown bedrest) reduced the sensitivity and buffer capacity of the vagal baroreceptor-cardiac reflex mechanisms and this impaired baroreflex function was associated with orthostatic hypotension. Since the reduction in plasma volume during BR was not correlated with impaired baroreflex function, a second study was conducted which demonstrated that the carotid-cardiac baroreflex response was not affected by either acute hypovolemia or hypervolemia. These results suggest that acute fluid replacement prior to reentry may not reverse impaired baroreflex function associated with postflight hypotension. In a third study, we demonstrated that one bout of maximal exercise increased baroreflex sensitivity and buffer capacity through 24 h post-exercise. These baroreflex changes were opposite to those observed following BR. Taken together, these data suggest that the contributions of reduced blood volume and impaired carotid-cardiac baroreflex function to orthostatic hypotension following exposure to microgravity are probably separate and additive; maximal exercise in addition to fluid replacement may provide an acute effective countermeasure against postflight hypotension.

Convertino, Victor A.↗

On the relationship between the multi-region relaxed variational principle and resistive inner-layer theory

We show that the variational energy principle of the multi-region relaxed magnetohydrodynamic (MRxMHD) model can be used to predict finite-pressure linear tearing instabilities. In this model, the plasma volume is sliced into sub-volumes separated by 'ideal interfaces', and in each volume the magnetic field relaxes to a Taylor state, where the pressure gradient $\nabla p = 0$. The MRxMHD model is implemented in the Stepped-Pressure Equilibrium Code (SPEC) so that the equilibrium solution in each region is computed while preserving the force balance across the interfaces. As SPEC computes the Hessian matrix (a discretized stability matrix), the stability of an MRxMHD equilibrium can also be computed with SPEC. In this article, using SPEC, we investigate the effect of local pressure gradients and the $\nabla p = 0$ in the vicinity of the resonant surface of a tearing mode. For low-beta plasma, we have been able to illustrate a relationship between the resistive singular-layer theory (Coppi et al 1966 Nucl. Fusion6 101; Glasser et al 1975 Phys. Fluids18 875–88) and the MRxMHD model. Within the singular layer, the volume-averaged magnetic helicity and the flux-averaged toroidal flux are shown to be the invariants for the linear tearing modes in SPEC simulations. Our technique to compute MRxMHD stability is first tested numerically in a cylindrical tokamak and its application in toroidal geometry is demonstrated. We demonstrate an agreement between the stability boundary obtained with SPEC simulation and the resistive inner-layer theories.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Serpent neutronics model of Wendelstein 7-X for 14.1 MeV neutrons

In this work, a Serpent 2 neutronics model of the Wendelstein 7-X (W7-X) stellarator is prepared, and an response function for the Scintillating-Fibre neutron detector (SciFi) is calculated using the model. The neutronics model includes the simplified geometry for the key components of the stellarator itself as well as the torus hall. The objective of the model is to assess the 14.1 MeV neutron flux from deuteron-triton fusions in W7-X, where the neutrons are modelled only until they have slowed down to 1 MeV energy. The key messages of this article are: demonstration of unstructured mesh geometry usage for stellarators, W7-X in particular; technical documentation of the model and first insights in fast neutron behaviour in W7-X, especially related to the SciFi: the model indicates that the superconducting coils are the strongest scatterers and block neutrons from large parts of the plasma. The back-scattering from e.g. massive steel support structures is found to be small. The SciFi will detect neutrons from an extended plasma volume in contrast to having an effective line-of-sight.

14 MeV↗