Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Oxidation in laser-generated metal plumes

The temporal evolution of atoms and molecules in a laser-produced plasma was investigated using optical emission spectroscopy for several metal targets (i.e., Al, Ti, Fe, Zr, Nb, and Ta). Plasmas from metal targets were generated by focusing 1064 nm, 6 ns pulses from an Nd:YAG laser. Gas-phase oxidation/plasma chemistry was initiated by adding O2 (partial pressures up to ≈20%) to an N2 environment where the total background pressure was kept at a constant 1 atmosphere. Temporally resolved emission spectral features were used to track the gas-phase oxidation. The dynamics of atomic and molecular species were monitored using space-resolved time-of-flight emission spectroscopy. Our results highlight that the partial pressure of O2 strongly influences spectral features and molecular formation in laser-produced plasmas. Atoms and molecules co-exist in plasmas, although with different temporal histories depending on the target material due to differences in thermo- and plasma chemical reactions occurring in the plume.

Kautz, Elizabeth J. (ORCID:0000000263389223)↗

Pedestal magnetic turbulence measurements in ELMy H-mode DIII-D plasmas by Faraday-effect polarimetry

Internal magnetic fluctuation measurements are utilized to identify turbulence associated with micro-tearing modes (MTM) in the DIII-D Edge-Localized-Mode (ELM)-y H-mode pedestal. Using a Faraday-effect polarimeter, magnetic turbulence (150–500 kHz) is directly observed with a typical line-averaged fluctuation amplitude of ~0.8 G at peak frequency (250 kHz) and ~15 G integrated over the spectrum from 150 to 500 kHz. Frequency, poloidal wavenumber, and propagation direction of the magnetic turbulence all serve to identify as MTM. Magnetic turbulence amplitude non-monotonically correlates with collision frequency, peaks off mid-plane, and correlates with electron temperature gradient evolution between ELMs, consistent with MTM features identified from theory and gyro-kinetic simulation. The magnetic turbulence growth correlates with confinement degradation in ELMy H-mode plasmas during a slow density ramp. In conclusion, these internal measurements provide unique constraints toward developing physics understanding and validating models of the H-mode pedestal for future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multi-chord, two-color interferometer using Hilbert transform phase detection for measuring electron density in spheromak plasmas

A new, four-chord, CO 2 /He–Ne heterodyne interferometer has been designed and built for measuring line-averaged plasma density in the HIT-SI3 and subsequent HIT-SIU sustained spheromak devices. The two-color system successfully eliminates vibration-induced errors caused by mirrors that are secured to the vacuum chamber and is able to resolve electron densities ne in the full operating range of 10 18 –10 20 m –3 in both experiments with an integrated error of 4.7 × 10 17 m –2 . Here, data are presented from high toroidal current plasma discharges, showing the time evolution of electron densities n e and j Φ /n e along multiple chords.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Early internal detection of magnetic tearing and implications for tokamak magnetohydrodynamic stability

Internal fluctuation measurements with Faraday-effect polarimetry in the DIII-D tokamak reveal the onset of a tearing mode with toroidal mode number n = 3 well before it is detected by the sensing coils external to the plasma. This mode appears before the n = 2, 1 modes and is first detected with internal measurements at a lower value of the ideal-wall kink beta limit than is indicated at the time of first detection by the sensing coils. When the mode is first detected, the linear resistive stability parameter, Δ′, indicates marginal stability and continues to do so until later when the mode amplitude begins increasing linearly with time—together suggesting a neoclassical origin for this mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of plasma atomic layer etching: Molecular dynamics simulations and optical emission spectroscopy

Atomic layer etching is intrinsically dynamic as it involves sequential and repeated exposures of a surface to be etched with different species at different energies. The composition and structure of the near surface region change in both time and depth. Full understanding of this process requires resolving both temporal and spatial variations. In this work, we consider silicon (Si) atomic layer etching (ALE) by alternating exposure to chlorine gas (Cl 2 ) and argon ions (Ar + ). Molecular dynamics (MD) simulations are compared to experimental measurements with the aim of better understanding the dynamics of ALE and to test the simulation procedure. The simulations help to more fully interpret the experimental measurements. Further, optical emission measured just above the surface being etched can be related to etch products and can, therefore, be directly compared to simulation predictions. The simulations capture the measured initial product distribution leaving the surface and match the measured etch per cycle reasonably well. While simulations demonstrate the importance of ion-induced surface damage and mixing into a layer below the surface, the depth of which depends mainly on ion energy, the experiments suggest there is more Cl mixed into the layer than the MD procedure predicts.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experimental and computational investigation into the hydrodynamics and chemical dynamics of laser ablation aluminum plasmas

Laser ablation plasma chemistry is governed by a complex interplay between hydrodynamic plasma-gas mixing processes, thermodynamics, and rapid high-temperature chemical reactions. Here, in this work, we investigate the gas-phase oxidation chemistry of ns-laser ablation aluminum plasmas in air using optical spectroscopy combined with advanced multi-physics modeling. Experimental measurements demonstrate the formation of AlO in the plasma plume as early as 1 μs while computational results reveal that several Al x O y species are distributed in the periphery of the plume at even earlier times (<20 ns) in the presence of large temperature gradients and strong shockwaves. Interactions with the ablation crater during rapid plume expansion are shown to initiate vortex formation, followed by mixing dynamics that work to pull AlO into the vortices to react with gas-phase Al to form Al 2 O. Oxygen and several aluminum oxides are simultaneously pulled up through the stem of the fireball, encouraging further intermixing between reacting species and enhanced molecular formation. This work concludes that chemical dynamics in laser ablation plasmas is driven by diffusion processes, concentration gradients, and plume hydrodynamics while strong shockwaves generated during laser ablation do not impede chemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas puff imaging on the TCV tokamak

We present the design and operation of a suite of Gas Puff Imaging (GPI) diagnostic systems installed on the Tokamak à Configuration Variable (TCV) for the study of turbulence in the plasma edge and Scrape-Off-Layer (SOL). These systems provide the unique ability to simultaneously collect poloidal 2D images of plasma dynamics at the outboard midplane, around the X-point, in both the High-Field Side (HFS) and Low-Field Side (LFS) SOL, and in the divertor region. We describe and characterize an innovative control system for deuterium and helium gas injection, which is becoming the default standard for the other gas injections at TCV. Extensive pre-design studies and the different detection systems are presented, including an array of avalanche photodiodes and a high-speed CMOS camera. First results with spatial and time resolutions of up to ≈2 mm and 0.5 µs, respectively, are described, and future upgrades of the GPI diagnostics for TCV are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

K-shell radiation and bright spot characteristics of high-energy-density Fe-Cr-Ni plasmas influenced by X-pinch load geometry

K-shell radiation is diagnostically advantageous for the study of high-energy-density plasmas. Here, the current work investigates the influence of load geometry on K-shell x-rays in Z-pinch plasmas produced on the 1-MA Zebra generator. Stainless steel (Fe: 69%, Cr: 20%, Ni: 9%) X-pinch wire loads are fielded with an interwire angle of 31° (small-angle) or 62.5° (large-angle), respectively and studied using various x-ray diode, imaging, and spectroscopic diagnostics. The large-angle geometry produced large, individual x-ray-emitting bright spots (> 3 keV) at the wire cross-point averaging areas ≥ 1 mm 2 , with noteworthy soft x-ray (> 0.75 keV) bursts and radiation yields ≤ 14.6 kJ. The small-angle geometry produced multiple x-ray-emitting bright spots extending the pinch axis with smaller average sizes (≤ 0.5 mm 2 ), consistent with stronger current, increased radiation yield (≥ 15.5 kJ), and notable hard x-ray (> 9 keV) bursts, which peak with largest cumulative bright spot size. Spectroscopic analysis is performed with non-LTE collisional-radiative modeling, indicating a cold, nonthermal plasma region radiating from neutral to Ne-like ions, a hot, thermal region radiating from Fe and Cr He- and Li-like ions, and an intermediate region radiating Kα satellites from Li-like to O-like ions. Modeling of the nonthermal and satellite features imply a fractional hot electron abundance ~0.1% and ~0.5% for large- and small-angle geometries, respectively. Relative intensity analysis is performed on Heα and Kα lines, revealing intensity ratios that deviate from the original wire composition. Optical depth estimates allude to optically thick, thermal K-shell plasmas with densities consistent with non-LTE modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast response, optical radiance measurements of low intensity impurity emission in WEST plasmas with staggered wavelength filters

Fast response acquisition of atomic line emission through the use of a filterscope has been implemented on the WEST tokamak at multiple poloidal locations. Filterscopes consist of a fiber-optic-based transmission from the tokamak to specifically engineered optical bandpasses and photomultiplier tubes (PMT) that collect the emission intensity to measure a radiance, L [W/cm2/str], over the specified bandpass. This diagnostic records plasma-wall interaction (PWI) properties (e.g. impurity emission and recycling of main fuel ions) up to a max acquisition rate of 100 kHz. These PMT radiometric measurements are calibrated into a line-normalized radiance, LN [photons/sec/cm2/str], similar to traditional spectrometers, which can later be converted to a particle flux. Low intensity emission peaks are difficult to quantify due to often comparable continuum levels, thus a secondary filter shifted to a judiciously-selected, line-free region (~1 nm away) allows for background subtraction. The system currently installed on WEST targets tungsten (W) gross sputtering specifically by monitoring, with a filter pair, the spectral region near the neutral W line emission (W I 400.9 nm). The line and background filters of the pair are centered at 400.6 nm and 403.1 nm, respectively. Through a set beam splitters on each sight line, the filter pair are measuring from the same location. The two L signals near W I are then subtracted from each other yielding only the W I LN. W I LN data from a recent WEST experimental campaign is presented and compared with plasma parameters and traditional spectrometer measurements of W I line emission to demonstrate the capabilities of this staggered-filter filterscope method. Specifically, the choice of WEST-specific bandpass curves for the W I LN will be illustrated based on this latter comparison.

Neff, Anton↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Spatiotemporal characterization of cerium monoxide in laser ablation plasmas using spectrally-resolved fast-gated imaging

The impact of oxidation chemistry on the emission characteristics and spatial structure of laser-produced Ce metal plasmas was investigated using laser-induced breakdown spectroscopy (LIBS) and time-resolved fast-gated imaging employing narrowband optical filters. Images of the plasma emission show that CeO coexists with atomic species in the periphery and vortex ring of the plasma plume. Image processing was also applied to combine independent monochromatic images of the plasma emission into a single merged image, culminating in a timelapse on the spatiotemporal evolution of atomic and molecular species within the plasma plume. The formation of CeO species was observed to proceed faster for plasmas generated in atmospheres containing larger concentrations of oxygen based on ratios of CeO-to-atomic emission intensities. Furthermore, these same ratios were shown to plateau and decrease at later times (≥25 μs), potentially indicating the depletion of CeO number densities in the plasma as the monoxide undergoes reactions to form higher polyatomic oxides. Altogether, these results provide fundamental insights into the chemical dynamics and intermixing between plasma-gas species in laser ablation cerium plasmas, advancing our understanding on optical signatures of nuclear-relevant materials to enable in-field measurement capabilities.

47 OTHER INSTRUMENTATION↗

Modeling of high intensity orbital angular momentum beams for laser–plasma interactions

In this work, we explore the field of high intensity orbital angular momentum (OAM) beams, their generation with spiral phase mirrors, and the theory behind modeling both ideal and realistic beams. We explore OAM beam asymmetries introduced by aberrations in the beam, manufacturing defects, and bandwidth. A full three-dimensional description of the paraxial Laguerre–Gaussian (LG) modes suitable for modeling beams down to f/2 focal geometries is derived. A perturbative approach to modeling asymmetric OAM beams is introduced showing that only three LG modes are sufficient to model a wide variety of OAM asymmetries. The models are compared with experimental results followed by a discussion on the future of high intensity OAM beams in plasma physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of plasma mirror capability for the OMEGA Extended Performance laser system

A plasma mirror platform was developed for the OMEGA-EP facility to redirect beams, thus enabling more flexible experimental configurations as well as a platform that can be used in the future to improve laser contrast. The plasma mirror reflected a short pulse focusing beam at 22.5° angle of incidence onto a 12.5 μm thick Cu foil, generating Bremsstrahlung and k α x rays, and accelerating ions and relativistic electrons. By measuring these secondary sources, the plasma mirror key performance metrics of integrated reflectivity and optical quality are inferred. It is shown that for a 5 ± 2 ps, 310 J laser pulse, the plasma mirror integrated reflectivity was 62 ± 13% at an operating fluence of 1670 J cm –2 , and that the resultant short pulse driven particle acceleration and x-ray generation indicate that the on target intensity was 3.1 × 10 18 W cm –2 , which is indicative of a good post-plasma mirror interaction beam optical quality. By deriving the plasma mirror performance metrics from the secondary source scalings, it was simultaneously demonstrated that the plasma mirror is ready for adoption in short pulse particle acceleration and high energy photon generation experiments using the OMEGA-EP system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A renewable double plasma mirror for Petawatt-class lasers

Exceptional pulse contrast can be critical for ultraintense laser experiments, particularly when using solid density targets, and their use is becoming widespread. However, current plasma mirror technology is becoming inadequate for the new generation of high repetition rate, high power lasers now available. We describe a novel double plasma mirror configuration based on renewable, free standing, ultrathin liquid crystal films tested at the BELLA Petawatt Laser Center. Although operating at a repetition rate of several shots per minute, this system can be scaled to a high repetition rate exceeding 1 Hz and represents an important step towards enabling sustained, continuous operation of plasma mirrors. We demonstrate an improvement of two to three orders of magnitude in contrast and a total throughput of 80%. We present the first measurements of a beam reflected from a single or double plasma mirror system using a wavefront sensor, showing a well preserved wavefront and spatial mode. Finally, we introduce a model that predicts the total throughput through this double plasma mirror. This is the first model that accurately predicts the peak reflectivity of a plasma mirror when given the laser temporal profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatio-temporal ion temperature and velocity measurements in a Z pinch using fast-framing spectroscopy

Ion Doppler spectroscopy (IDS) is a diagnostic technique that measures plasma ion temperature and velocity without perturbing the plasma with a physical probe. The ZaP-HD Flow Z-Pinch Experiment at the University of Washington uses this technique to resolve radial temperature and velocity profiles of a Z-pinch plasma. The pinch lifetime is approximately 100 ms, therefore diagnostics capable of sub-microsecond resolution are required to measure the evolution of temperature and velocity profiles. The previous IDS diagnostic system was only capable of collecting a single measurement during a plasma pulse. Here, an improved system has been developed to measure radially-resolved ion temperature and velocity for the entire Z-pinch lifetime. A Kirana 05M ultra-fast framing camera and SIL ultraviolet intensifier are used to record up to 100 spectra per plasma pulse. The temperature is computed from Doppler broadening of the carbon-III (229.687 nm) impurity ion radiation and the velocity from the Doppler shift of carbon-III. Measurements are able to resolve the evolution of the ion temperature and velocity over the course of a plasma pulse. The diagnostic has significantly reduced the number of pulses required and provides a more coherent measurement of plasma dynamics than the previous system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗