Search NASA⌕ Search

SEARCH · Search NASA

Results for “Platform Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Progress report on the Block 1 VLBI correlator implementation

The Block 1 VLBI Processor Subsystem (VPS) of the Very Long Baseline Interferometry (VLBI) System for the determination of station clock-sync parameters, UT1 and polar motion, and station platform parameters and for use in spacecraft tracking is discussed. The Block 1 VPS performs three basic functions: it receives the 500 kbit/sec video data over the GCF wideband data lines from each of the three DSN 64 m antennas; it cross correlates data; and it performs several postcorrelation data reduction operations on the correlated data including calibration, editing, and parameter estimation.

Peterson, J. C.↗

Some Aspects of Attitude Stability of Tethered Space Stations

The stability of attitude motion of space stations composed by platforms connected tethers is studied. The motion is assumed to be three dimensional and the station rigid. First, the well known linearized theory is adopted and the location of different configurations in the stability chart is found; second, a destabilizing feature of finite amplitude motion is outlined as a function of inertia parameters.

Bergamasui, S.↗

The sensitivity of synthetic aperture radiometers for remote sensing applications from space

Aperture synthesis offers a means of realizing the full potential microwave remote sensing from space by helping to overcome the limitations set by antenna size. The result is a potentially lighter, more adaptable structure for applications in space. However, because the physical collecting area is reduced, the signal-to-noise ratio is also reduced and may adversely affect the radiometric sensitivity. Sensitivity is an especially critical issue for measurements from low earth orbit because the motion of the platform (about 7 km/s) limits the integration time available for forming an image. The purpose of this paper is to develop expressions for the sensitivity of remote sensing systems which use aperture synthesis. The objective is to develop basic equations general enough to be used to obtain the sensitivity of the several variations of aperture synthesis which have been proposed for sensors in space. The conventional microwave imager (a scanning total power radiometer) is treated as a special case, and the paper concludes with a comparison of three synthetic aperture configurations with the conventional imager.

Le Vine, David M.↗

The sensitivity of synthetic aperture radiometers for remote sensing applications from space

Aperture synthesis offers a means of realizing the full potential of microwave remote sensing from space by helping to overcome the limitations set by antenna size. The result is a potentially lighter, more adaptable structure for applications in space. However, because the physical collecting area is reduced, the signal-to-noise ratio is reduced and may adversely affect the radiometric sensitivity. Sensitivity is an especially critical issue for measurements to be made from low earth orbit because the motion of the platform limits the integration time available for forming an image. The purpose is to develop expression for the sensitivity of remote sensing systems which use aperture synthesis. The objective is to develop basic equations general enough to be used to obtain the sensitivity of the several variations of aperture synthesis which were proposed for sensors in space. The conventional microwave imager (a scanning total power radiometer) is treated as a special case and a comparison of three synthetic aperture configurations with the conventional imager is presented.

Levine, D. M.↗

Magnetic Gearing Versus Conventional Gearing in Actuators for Aerospace Applications

Magnetic geared actuators (MGA) are designed to perform highly reliable, robust and precise motion on satellite platforms or aerospace vehicles. The design allows MGA to be used for various tasks in space applications. In contrast to conventional geared drives, the contact and lubrication free force transmitting elements lead to a considerable lifetime and range extension of drive systems. This paper describes the fundamentals of magnetic wobbling gears (MWG) and the deduced inherent characteristics, and compares conventional and magnetic gearing.

Puchhammer, Gregor↗

Reducing Errors in Velocity–Azimuth Display (VAD) Wind and Deformation Retrievals from Airborne Doppler Radars in Convective Environments

The present study describes methods to reduce the uncertainty of velocity–azimuth display (VAD) wind and deformation retrievals from downward-pointing, conically scanning, airborne Doppler radars. These retrievals have important applications in data assimilation and real-time data processing. Several error sources for VAD retrievals are considered here, including violations to the underlying wind field assumptions, Doppler velocity noise, data gaps, temporal variability, and the spatial weighting function of the VAD retrieval. Specific to airborne VAD retrievals, we also consider errors produced due to the radar scans occurring while the instrument platform is in motion. While VAD retrievals are typically performed using data from a single antenna revolution, other strategies for selecting data can be used to reduce retrieval errors. Four such data selection strategies for airborne VAD retrievals are evaluated here with respect to their effects on the errors. These methods are evaluated using the second hurricane nature run numerical simulation, analytic wind fields, and observed Doppler radar radial velocities. The proposed methods are shown to reduce the median absolute error of the VAD wind retrievals, especially in the vicinity of deep convection embedded in stratiform precipitation. The median absolute error due to wind field assumption violations for the along-track and for the across-track wind is reduced from 0.36 to 0.08 m s−1 and from 0.35 to 0.24 m s−1, respectively. Although the study focuses on Doppler radars, the results are equally applicable to conically scanning Doppler lidars as well.

Charles N Helms↗

Lunar Scout Infrared Detector (LSIRD): Simple low-cost imaging spectrometer

A novel design for a compact, light weight, imaging spectrometer has been proposed for an orbiting Lunar mapping mission. Simple in design, its dual arm optical system employs a transmission grating and a dichroic mirror to provide continous two-octave spectral response. The grating's first order wavelengths are reflected into the SWIR arm, while the second order wavelenghts are transmitted to the VNIR arm. The instrument design is that of a push broom camera. It uses one of the detector(s) dimensions for spectral selection, the other detector(s) dimension for cross-track spatial selection, and the foward motion of the platform (in this case, a spececraft) for down-track spatial coverage.

Lunar↗

Waveform warping for general frequency-modulated radar waveforms

Various technologies pertaining to motion compensation for radar systems using FM waveforms are described herein. A waveform generator outputs a parametrized, pulsed FM waveform to a radar antenna, whereupon the radar antenna emits pulsed electromagnetic (EM) radiation into a target area based upon the parametrized FM waveform. The parametrized FM waveform compensates for motion of a radar platform that includes the antenna. The parametrized FM waveform compensates for inter-pulse Doppler effects by introducing a time delay to a reference FM waveform, and compensates for intra-pulse Doppler effects by time dilating, or frequency-scaling, pulses of the reference waveform. The parametrized FM waveform can be generated by modifying the reference waveform based on first and second parameters, where the parameters are based upon motion of the radar platform and changes in echo return delay times from one pulse to another.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Coupled loads analysis of a novel shared-mooring floating wind farm

Shared mooring lines are a method to reduce the stationkeeping cost of floating offshore wind farms; however, their impacts on floating array dynamics are not yet well understood. Here this article presents advancements to floating wind farm simulation capabilities that allow the dynamic modeling of shared-mooring floating wind arrays - specifically, platform coupling through shared lines and proper phasing of wave loads across the array. These capabilities are demonstrated on a 10-turbine shared-mooring array featuring two staggered rows of wind turbines. A baseline array design with individually moored turbines is used as a basis for comparison. Coupled analysis using FAST.Farm shows that the shared-mooring design has smaller fluctuations in surge when compared to the baseline design. The mean and maximum platform offsets are highest in normal operating conditions, but the maximum mooring line tensions are highest in 50-year storm conditions. Power spectral density analysis of platform surge and sway motions shows that the shared mooring configuration does not introduce any significant inter-platform resonances. The tower-base bending moment statistics and the line tension damage equivalent loads indicate no consequential differences in turbine loading or mooring fatigue life. Anchor load analysis shows that the total required anchor capacity for the shared-mooring array is decreased by approximately 25% when shared anchors are used. Dynamic simulations of the shared mooring system under line failures show that remaining line tensions stay within bounds and that offsets are significantly smaller when compared to the baseline design. Overall, the results show that shared moorings do not introduce any dynamic response concerns in this floating wind array design.

17 WIND ENERGY↗

Robotic servicing on Earth orbiting satellites

An articulated calibration experiment (ACE) concept study was conducted by GSFC to prove the feasibility of instrument calibration by a resident robot on the EOS spacecraft. This study provided a basis for determining the most suitable robot design and operations concepts required to perform accurate instrument calibration on the EOS platform. During the study, the first-order dynamics of robot walking and docking motions as it moves about were evaluated to determine the accelerations and torques imparted into the spacecraft. The major perturbation to the spacecraft was the effect of robot motion and impact on the EOS platform attitude control system. If not carefully controlled, these levels could exceed the maximum allowable levels. As a result of the EOS/ACE feasibility study, a GSFC robotic ground development effort was established. This effort, as described on the paper, will identify the technology required to resolve issues associated with robot in-space servicing dynamics and its impact on spacecraft and designs. Of primary concern are those relating to robot contact loads, docking of robotic systems on space platforms, and basic motion and mobility.

Ollendorf, Stanford↗

OC7 phase I: Toward practical sea-state-dependent modeling of hydrodynamic viscous drag and damping

Here, this article presents a collaborative research campaign under the OC7 project on refining the engineering modeling approach for hydrodynamic viscous drag and damping on floating wind platforms, focusing on the adjustment of hydrodynamic drag and damping coefficients for different sea states. The participant simulation results show significant improvements over the previous OC6 project in predicting the low-frequency resonance motion under nonoperational conditions. The improvements are mainly due to enhanced modeling, including the adoption of wave stretching, and directly tuning the coefficients to measured platform motion in waves instead of free decay. For accurate predictions of mean- and slow-drift motion, the better performing models use a decreasing column splash zone drag coefficient and increasing surge damping/drag with increasing wave height. The model tuning for heave and pitch resonance shows less consistency. Generally, both quadratic drag and additional heave or pitch damping are needed for accurate predictions. Alternatively, a quadratic drag formulation with velocity filtering for the rectangular pontoons leads to improved predictions without additional damping. This model is also potentially more predictive, requiring minimal adjustment to its parameters for different conditions.

17 WIND ENERGY↗

Report on the Second ARM Mobile Facility (AMF2) Roll, Pitch, and Heave (RPH) Stabilization Platform: Design and Evaluation

One of the primary objectives of the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility’s second Mobile Facility (AMF2) is to obtain reliable measurements of solar, surface, and atmospheric radiation, as well as cloud and atmospheric properties, from ocean-going vessels. To ensure that these climatic measurements are representative and accurate, many AMF2 instrument systems are designed to collect data in a zenith orientation. A pillar of the AMF2 strategy in this effort is the use of a stable platform. The purpose of the platform is to 1) mitigate vessel motion for instruments that require a truly vertical orientation and keep them pointed in the zenith direction, and 2) allow for accurate positioning for viewing or shading of the sensors from direct sunlight. Numerous ARM instruments fall into these categories, but perhaps the most important are the vertically pointing cloud radars, for which vertical motions are a critical parameter. During the design and construction phase of AMF2, an inexpensive stable platform was purchased to perform the stabilization tasks for some of these instruments. The first table compensated for roll, pitch, and yaw (RPY) and was reported upon in a previous technical report (Kafle and Coulter, 2012). Subsequently, a second table was purchased specifically for operation with the Marine W-band cloud radar (MWACR). Computer programs originally developed for RPY were modified to communicate with the new platform controller and with an inertial measurements platform that measures true ship motion components (roll, pitch, yaw, surge, sway, and heave). This platform could not be tested dynamically for RPY because of time constraints requiring its deployment aboard the container ship Horizon Spirit in September 2013. Hence the initial motion tests were conducted on the initial cruise. Subsequent cruises provided additional test results. The platform, as tested, meets all the design and performance criteria established for its use. This is a report of the results of those efforts and the critical points in moving forward

54 ENVIRONMENTAL SCIENCES↗

Adaptive control of a Stewart platform-based manipulator

A joint-space adaptive control scheme for controlling noncompliant motion of a Stewart platform-based manipulator (SPBM) was implemented in the Hardware Real-Time Emulator at Goddard Space Flight Center. The six-degrees of freedom SPBM uses two platforms and six linear actuators driven by dc motors. The adaptive control scheme is based on proportional-derivative controllers whose gains are adjusted by an adaptation law based on model reference adaptive control and Liapunov direct method. It is concluded that the adaptive control scheme provides superior tracking capability as compared to fixed-gain controllers.

Nguyen, Charles C.↗

SU-E-T-648: Quality Assurance Using the RADPOS System for 4D Radiotherapy with CyberKnife

Purpose: The CyberKnife robotic radiosurgery system uses Synchrony respiratory motion compensation, which requires independent performance verification. In this work, the RADPOS 4D dosimetry system’s motion measurements are compared with internal fiducial position measurements. In addition, RADPOS measurements are compared with Synchrony’s predictive correlation model, which is based on internal fiducial and external LED marker position measurements. Methods: A treatment plan was created for a lung insert containing fiducials, RADPOS detector, and Solid Water tumor phantom. Two Quasar Respiratory Motion Phantoms (Q1 and Q2) and two RADPOS detectors (R1 and R2) were used: Q1 simulated lung motion with a lung insert moving in the superior/inferior direction, while Q2 simulated chest motion with a chest platform moving in the anterior/posterior direction. Before treatment, R1 was secured inside of the tumor phantom within Q1, while LED markers and R2 were positioned on the chest platform of Q2. Two treatment delivery cases were studied: isocentric plan (I) and non-isocentric patient plan (P). Four motion cases were studied: no motion (0), sinusoidal and in-phase (1), sinusoidal and out-of-phase (2), patient waveform and out-of-phase (3). A coordinate alignment algorithm was implemented, allowing RADPOS and model position data to be compared within the fiducial coordinate system. Results: The standard deviation of the differences between RADPOS and fiducial position measurements was below 0.6 mm for all experimental cases. The standard deviation of the differences between RADPOS and model position data was 1.0, 1.5, and 1.6 mm along the primary direction of motion for case I1, I2, and P3, respectively. Conclusion: Our work demonstrates that RADPOS is a useful tool for independent quality assurance of CyberKnife treatment with Synchrony respiratory compensation. RADPOS and fiducial position measurement closely match, and RADPOS confirms the effectiveness of CyberKnife’s Synchrony motion tracking. This work was supported by OCAIRO (Ontario Consortium for Adaptive Interventions in Radiation Oncology) grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wind turbine blade testing system using base excitation

An apparatus (500) for fatigue testing elongate test articles (404) including wind turbine blades through forced or resonant excitation of the base (406) of the test articles (404). The apparatus (500) includes a testing platform or foundation (402). A blade support (410) is provided for retaining or supporting a base (406) of an elongate test article (404), and the blade support (410) is pivotally mounted on the testing platform (402) with at least two degrees of freedom of motion relative to the testing platform (402). An excitation input assembly (540) is interconnected with the blade support (410) and includes first and second actuators (444, 446, 541) that act to concurrently apply forces or loads to the blade support (410). The actuator forces are cyclically applied in first and second transverse directions. The test article (404) responds to shaking of its base (406) by oscillating in two, transverse directions (505, 507).

42 ENGINEERING↗

Four-Degree-of-Freedom Platform

Hydraulic actuators make a new motion control system more compact and more efficient than previous designs that use gimbals. System moves a platform in four degrees of freedom--simultaneous pitch, roll, yaw, and displacement. Developed for flight simulators, kinematic concept may also be useful in stabilizing platforms for shipboard equipment, material-handling machinery, and construction equipment.

Chou, R. C.↗

Remote sensing using solid-state array technology

The paper describes the design features and capabilities of a remote sensor that uses solid-state linear arrays and operates in a 'pushbroom' scan mode to provide the required performance. Pushbroom scanning is a term describing the technique of using the forward motion of a satellite platform to sweep a linear array of detectors oriented perpendicular to the ground track across a scene being imaged. One array is typically used for each spectral channel. Satellite motion provides one direction of scan and electronic sampling of the detectors in the crosstrack dimension provides the orthogonal scan component to form an image. The detector array is sampled at the appropriate rate so that contiguous lines are produced. The performance of a pushbroom system is discussed relative to radiometric sensitivity, detector array geometric fidelity, and radiometric correction. System advantages are precision geometric positioning of the detectors, very high sensitivity and favorable SNR, low power consumption, and no moving optics.

Thompson, L. L.↗

A Low Mass Translation Mechanism for Planetary FTIR Spectrometry using an Ultrasonic Piezo Linear Motor

One of the key components of a Fourier Transform Infrared Spectrometer (FTIR) is the linear translation stage used to vary the optical path length between the two arms of the interferometer. This translation mechanism must produce extremely constant velocity motion across its entire range of travel to allow the instrument to attain high signal-to-noise ratio and spectral resolving power. A new spectrometer is being developed at the Jet Propulsion Laboratory under NASA s Planetary Instrument Definition and Development Program (PIDDP). The goal of this project is to build upon existing spaceborne FTIR spectrometer technology to produce a new instrument prototype that has drastically superior spectral resolution and substantially lower mass, making it feasible for planetary exploration. In order to achieve these goals, Alliance Spacesystems, Inc. (ASI) has developed a linear translation mechanism using a novel ultrasonic piezo linear motor in conjunction with a fully kinematic, fault tolerant linear rail system. The piezo motor provides extremely smooth motion, is inherently redundant, and is capable of producing unlimited travel. The kinematic rail uses spherical Vespel(R). rollers and bushings, which eliminates the need for wet lubrication, while providing a fault tolerant platform for smooth linear motion that will not bind under misalignment or structural deformation. This system can produce velocities from 10 - 100 mm/s with less than 1% velocity error over the entire 100-mm length of travel for a total mechanism mass of less than 850 grams. This system has performed over half a million strokes under vacuum without excessive wear or degradation in performance. This paper covers the design, development, and testing of this linear translation mechanism as part of the Planetary Atmosphere Occultation Spectrometer (PAOS) instrument prototype development program.

Heverly, Matthew↗